MICROPROCESSOR TOTALISATOR DOSAX SERIES

Similar documents
MICROPROCESSOR BATCH CONTROLLER MOD.DOSAX

MOD. KBC HEAD KONTAX BATCH CONTROLLER

INSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

Type MVTT 14 and MVTT 15: Static Digital Time delay relays

Digital Keypad Introduction

SEQUENCER FOR DEDUSTING PLANTS

Intrinsically safe batch controller Batching Master 110i

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

Digital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER MODEL : ARC2020

HD 2013 HD 2013-D AA-26 AA-27

MODEL SW6000 & SM6100 CENELEC INSTRUCTIONS

Operating Instructions for Digital Thermometers. Model: DTM

MIC-2 MKII, Multi-instrument DATA SHEET

M15S OPERATION MANUAL

INSTALLATION DKM-409 NETWORK ANALYSER WITH HARMONIC MEASUREMENT AND SCOPEMETER. Before installation:

MIC-2 Multi-instrument DATA SHEET

Induction Flow Meter. AcquaMAG. Installation and Operating Manual

DIGITAL ANZEIGE. for Industry Applications. Series PAXP, PAXDP. Key-Features:

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

CHAPTER 1. Introduction Introduction 3

Panel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.

SHPFI Smart Frequency to Current Converter & Pulse Scaler Installation and Operating Instructions

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

DIGITAL DISPLAY. for Industry Applications. Series WAY-D. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series PAXD. Key-Features:

DKM-405 NETWORK ANALYSER WITH TOTAL HARMONIC DISTORTION DISPLAY

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

Neon pr. ph/ ORP measurement. Applications. Description

PROGRAMMER WITH A USB LINK PD14 USER S MANUAL

DIGITAL DISPLAY. for Industry Applications. Serie REX-D. Key-Features:

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

180 Series Keypad. Handbook. Revision 2.1

AS Keypad User Manual

EM24-DIN PFA, PFB & X models

Instruction Manual. Instrument Amplifier HE 017

SD1. Differential Controller. Operating and Installation Instructions F2 72.3

VEGA II. Electronic counter. The solutions that count

VIBRATION MONITOR CX-RLY

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

MobilControl MC 4000 OWNER S MANUAL

Operating Manual. ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz. Product Features:

EM24-DIN COMMUNICATION PROTOCOL. Version 3 Revision 1

EM24-DIN COMMUNICATION PROTOCOL. Version 3 Revision 0

signo 727 SSI Operating Instructions Position-Indicator with/without limit values and SSI input from absolute encoder

IPM650 Intelligent Panel-Mount Display

EWCH 485 Electronic Pulse Counter

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

GS400. Electronic Auto-Ranging DIN Panel Mounted Positioner

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

TPE 1464 Series Pressure Transducer

EM26-96 COMMUNICATION PROTOCOL. Version 1 Revision 0

Strain Gauge Converter

Model 332 Differential Pressure Transmitter

Control instruments GUARDIAN 2 - GUARDIAN 3

RELAY MODULE A/B INSTALLATION/USE INSTRUCTIONS

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

Operating Instructions Differential Pressure Transducer PS27

Technical Bulletin (TB-0040)

PP-8516 & PP Electronic Static Pressure Controllers and Transmitters for Cental Air Supply Systems General Instructions

ME2008. ManuFlo Flow Measurement & Control Products FEATURES. Page 1

NPW800R RETROFITTING. Power and Volatge Protection Relay

signo 727 SSI operating instructions

EXCELL PRECISION CO., LTD.

MicroTrans EQ Signal Processor. Operation & Maintenance Manual

E2Q4 Square Proximity Sensor

ACT-1B Series Panel Tachometer

Flow Computer compart DXF 351. Universal Application for Gas, Steam and Liquids

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

HI-POT TESTER User Manual

FS-21.doc Status Filter Control FS-21. EasyRange

PROTECTION RELAYS THE ULTRA LINE NUMERICAL MULTIFUNCTION INTELLIGENT DEVICE FOR PROTECTION, SUPERVISION, METERING AND CONTROL

Protection and control. Sepam range Sepam 100 RT. Merlin Gerin Square D Telemecanique

" User s Manual. Adash 3900-II Online Vibration Monitoring System. Applications: Characteristics:

INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT

Installation and Maintenance Instructions for GC55 Differential Pressure Transducer Version 1.0 5/11

Ethernet / RS485 Gateway

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

Users Manual. TABLE OF CONTENTS 1 WORKING PRINCIPLE Operating limits Applications... 2

XT-9100 Technical Bulletin

For Transmission, Distribution and Machinery protection.

( F L O W I Z F A M I L Y )

EM21 COMMUNICATION PROTOCOL. Version 1 Revision 0

Precision Balance W3200 Series Operating Manual

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

FEMA ELECTRÓNICA. Series BDF. LARGE DISPLAYS for parallel BCD code. USER S MANUAL (HT r190307) BDF-xx-BCD for parallel BCD code

DC100 Digital Dispenser Operating Manual

Temperature/Process Meter

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

MOS FET Relay. Ordering Information. Application Examples G3VM- XN(F)/4N(F)

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

TABLE OF CONTENTS 1. OVERVIEW SPECIFICATIONS UNPACKING & INSTALLATION FUNCTION OVERVIEW FUNCTION OVERVIEW...

DIGITAL PEAK HOLDER CSD-709. Instruction Manual EN C

NETRONICS HS3500 CONTROLLER

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

Transcription:

MICROPROCESSOR TOTALISATOR DOSAX 8001-8008 SERIES THE APPLIANCE DESCRIBED HEREIN CONFORMS TO STANDARDS EN55011, EN61000-3-2, IEC 1000-4-2, IEC1000-4-4 19/04/2005 VERSION 2.0

INTRODUCTORY NOTE The operations described in this manual are applicable to both panels supplied ready wired and panel fronts wired by the client, however slight differences may occur according to the applications required. CAUTION Before switching the panel on, ensure that the power supply conforms to that indicated on the terminal board diagram or on the rear of the appliance, a variation in voltage of ± 10% is permitted, operating temperature: 10 +45 C. POWERING UP Use the master switch to switch the panel on, the appliance s display or the line pilot light will indicate that it has been switched on. ASSEMBLY The panel has been designed to be wall-mounted. In order for the appliance to function properly, the operating temperature must be 10 to +45 C and the surrounding atmosphere must not be corrosive or excessively damp. Do not install in areas subject to intense vibrations. When the appliance is switched on, the following page will appear on the display for approximately 5 seconds. CRAIND IMPIANTI MILAN - ITALY The following page will then appear for approximately 2 seconds: CUSTOMER SERVICE TEL.02-5462113 CAUTION: 1) IN THE FOLLOWING DRAWINGS, THE VALUES GIVEN ARE FOR EXAMPLE USE ONLY. 2) THE OPERATION OF A SINGLE CHANNEL IS DESCRIBED, HOWEVER THE PROCEDURE IS IDENTICAL FOR MULTI-CHANNEL INSTRUMENTS 3) DOSAX 8001 = 1 CHANNEL, DOSAX 8002 = 2 CHANNELS,.. DOSAX 8008 = 8 CHANNELS 4) USE THE ESC KEY TO QUIT THE VARIOUS MENUS 1

STARTING PAGE: 1=TOT.P 3=FLOW 2=TOT.S 4=SETUP DESCRIPTION OF FUNCTIONS Press the number key associated to the visualisation option preferred: 1 = Partial totalisators (can be RESET by the operator using the CLEAR key) 2 = Historical totalisators (cannot be RESET by the operator) 3 = Flow (flow indicators) 4 = Setup (monitoring and adjustment parameters) PARTIAL TOTALISATORS: TOT. 1 00000450 CL=RESET ENTER In the example above, the totalised value in channel 1 is 450 litres Press ENTER to change page Press ESC to quit menu Press CLEAR to reset totalisator HISTORICAL TOTALISATORS: HISTORICAL1 0000000450 QUIT I In the example above, the totalised value in the channel 1 is 450 litres Press ENTER to change page Press ESC to quit menu 2

FLOW FLOW 1 lit/h 000220 In the example above the flow detected inside channel 1 is 220 litres/hour Press ENTER to change page Press ESC to quit menu SETUP The following page appears when the SETUP menu is selected: 1 = TOT. PARAMETERS 2 = FLOW PARAMETERS DESCRIPTION OF FUNCTIONS Press the key associated to the desired visualisation option: 1 = Totalisator parameters (error % correction, factorisers, pulse output, no. decimals) 2 = Flow parameters (no. decimals, flow scale, reading means, alarms) TOTALISATOR PARAMETERS The ERROR PERCENTAGE COEFFICIENT is displayed: % ERROR 1 00.00 It is possible to introduce corrections to any dosage errors in this page: Perform three identical and consecutive dosage trials (with line full) Set the mean value of the error detected by typing it in using the keypad: to obtain a minus sign press F2, 3

to select the decimal point, press Press F1 to return to previous parameter Press ESC to quit page visualisation and return to the main menu By pressing ENTER it is possible to access the following menu page: K1 0.000001 Litre-counter factorisation coefficient: this value is normally set in the CRAIND workshops. Should it require modifying, take note of the litre-counter (mounted on dosage line) registration number and contact CRAIND staff, who will inform you of the original calibration value. In the event of errors, use CLEAR to erase any incorrect figures Press ESC to quit page visualisation and return to main menu By pressing ENTER it is possible to access the following menu page: ON OUT 1 00.00 By enabling this function, it is possible to have a factorised pulse output on the terminal board corresponding to the quantity of product measured: 00.00 = output disabled 00.10 = output enabled with activation time of output pulse = 1 tenth of a second (max. settable time 99 sec.) In the event of errors, use CLEAR to erase any incorrect numbers Press ESC to quit page visualisation and return to main menu 4

By pressing ENTER the following menu page will appear: N DECIMALS 0 In this page it is possible to enable a decimal point in the totalisation visualisation according to the following order: 0 = decimal point disabled 1 = 1 decimal number enabled 2 = 2 decimal numbers enabled In the event of errors, use CLEAR to erase any incorrect numbers By pressing ENTER or ESC one quits page visualisation and returns to the SETUP menu, press ESC again to return to the main menu FLOW PARAMETERS FLOW SCALE 1 0 In this page it is possible to define the flow scale visualised according to the following order: 0 = litres/second 1 = litres/minute 2 = litres/hour In the event of errors, use CLEAR to erase any incorrect numbers Press ESC to quit page visualisation and return to main menu By pressing ENTER the following menu page will appear: 5

NO. MEANS: 1 001 In this page it is possible to introduce a value (from 1 to 100) of flow reading means; this parameter can be used when the flow reading is particularly unstable. Consider that: 001 = reading fast in increasing or decreasing, but less stable 100 = reading slow in increasing or decreasing, but more stable In the event of errors, use CLEAR to erase any incorrect numbers Press ESC to quit page visualisation By pressing ENTER the following MIN. AL 1 000000 and return to main menu menu page will appear: In this page it is possible to introduce a minimum flow alarm (the alarm output is shown on the terminal board). The minimum alarm is used to signal any malfunctions (such as lack of product, tube ruptures, etc.), when it is triggered, the display shows the following message at regular intervals MINIMUM FLOW ALARM 1 In the event of errors, use CLEAR to erase any incorrect numbers Press ESC to quit page visualisation and return to main menu By pressing ENTER the following menu page will appear: 6

MAX. AL 1 000000 In this page it is possible to introduce the maximum flow alarm (the alarm output is shown on the terminal board). The maximum alarm serves to prevent excessive flow from damaging the dosage system. When the alarm triggers, the display shows the following message at regular intervals. MAXIMUM ALARM 1 HIGH FLOW Reduce flow to conserve the dosage system s measurement elements. In the event of errors, use CLEAR to erase any incorrect numbers Press ESC to quit page visualisation and return to main menu By pressing ENTER the following menu page will appear: MIN. AL. DELAY 000 In this page it is possible to introduce a minimum alarm enabling delay time. This delay is used to favour tube filling when the plant is switched on. 000 = timer excluded 127 = max. time (127 sec.) In the event of errors, use CLEAR to erase any incorrect numbers Press ENTER or ESC to quit page visualisation and return to SETUP menu, press ESC again to return to main menu. 7

Power supply description: Pin N. Description 1 24 V ac 3 0 V ac Description of digital input connections: N.B.: use shielded cables in the presence of strong electromagnetic disturbance or the passage of conductors close to the power lines. Shielding must be earthed on one side only and must not be used as a return for signals. Input N. Pin N. Description Com-in 21 Common inputs: litre-counter (+12 V dc) 0 Vdc 13 0 Vdc (normally unused) 1 2 Digital input 1 (litre-counter 1) 2 4 Digital input 2 (litre-counter 2) 3 5 Digital input 3 (litre-counter 3) 4 6 Digital input 4 (litre-counter 4) 5 7 Digital input 5 (litre-counter 5) 6 8 Digital input 6 (litre-counter 6) 7 9 Digital input 3 (litre-counter 7) 8 10 Digital input 8 (litre-counter 8) 10 12 Partial totalisators reset 8

Description of digital output connections: Connection with Mos-fet outputs and relays: Output no. Pin Description N. Com-out + 17 Common outputs +24 V dc Com-out - 12 Common outputs 0Vdc 1 18 Out 1Ampere (factorised pulses output 1) 2 16 Out 1Ampere (factorised pulses output 2) 3 14 Out 1Ampere (factorised pulses output 3) 4 1 Out 1Ampere (factorised pulses output 4) 5 9 Out 1Ampere (factorised pulses output 5) 6 13 Out 1Ampere (factorised pulses output 6) 7 4 Out 1Ampere (factorised pulses output 7) 8 6 Out 1Ampere (factorised pulses output 8) 9 10 Out 1Ampere (minimum and maximum alarm output) Digital outputs : 17 (+24 V dc external) Output no.2 16 12 (0 V dc external) 9

CUTTING FREQUENCY (Note: only for instruments DOSAX 8001-8002-8003-8004-8005) The CUTTING FREQUENCY parameter has been included in the set-up menu. Using this function it is possible to filter any recoils of mechanical contacts or disturbed signals. All signals that exceed the cutting frequency are not considered. To set the parameter correctly, enter a value (expressed in Hz) that is 10-20% higher than the incoming signal at maximum capacity. CUT. F. 013.0 EXIT ENTER:YES Example: pulses coming from a meter that issues 20 pulses/litre maximum meter capacity = 2000 litres/hour 20 x 2000 = 11.11 Hz (frequency at maximum capacity) 3600 enter a minimum value of 13 Hz and confirm with the ENTER key 10

PRINTER Using the menus described, it is possible to print out the following data: NOTE: 1. time and date 2. 2 lines of text (for example, company name or production department) 3. the product name 4. the product quantity 5. the instantaneous load value 2 and 3 can only be memorized in CRAIND laboratories The SET UP page, described in the MICROPROCESSOR TOTALIZATOR DOSAX 8001-8808 SERIES manual (page 3), is replaced by the following: 1=TOT. 3=DATE 2=FLOW 4=PRINT Options 1 (totalizators) and 2 (flow) are the same as those described in the TOTALIZATOR manual. It is possible to exit the pages (i.e. in the case of an error) by using the ESC key. Incorrect data can be cancelled by pressing the CLEAR button PRINTING MENU Option 3 = DATE Pressing key 3 displays the following page, where it is possible to enter the time and date using the numerical keyboard HOUR 00 MIN 00 D 00 M 00 Y 00 After having introduced that last piece of information (year), press the ENTER key to return to the main menu Each time this page is displayed, the data is reset to 0 (as in the figure above) Option 4 = PRINTING Pressing key 4 displays the following page: PRINT CAPACITY 1 PRINT TEXT 0 11

PRINT CAPACITY By typing 1 and pressing the ENTER key to confirm, the capacity will be printed along with the other values By typing 0 and pressing the ENTER key to confirm, the capacity will not be printed Note: the capacity value is the one measured in the moment preceding the print-out. PRINT TEXT If the instrument has any memorized text (for example company name or production department), it is possible to choose whether to print this information. by typing 1 and pressing the ENTER key to confirm, the text will be printed along with the other values by typing 0 and pressing the ENTER key to confirm, the text will not be printed Press the ESC key to exit the printing menu The printing is activated by input No. 9 terminal 11 in the input terminal board. For connections, consult the MICROPROCESSOR TOTALIZATOR DOSAX 8001-8008 SERIES manual (page 8) 12

PASSWORD SETUP The user is asked to enter a 4-digit password to protect access to SETUP parameters. PASSWORD the password can be entered using the numeric keys: 8008 (not modifiable) To confirm press the ENTER key If you enter the wrong password you can enter the correct one again to exit this page press the ESC key 13