Eltek TU GenII AQ110A comprehensive portable air quality monitor transmitter

Similar documents
Eltek TU User Instructions for RC250 receiver

Indoor Air Quality Meter/Datalogger

User Guide. Indoor Air Quality Meter/Datalogger. Model EA80

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

Auto-timer Datalogging Temperature / Humidity Meter

Gas detection just got personal

2-Way Wireless I/O Expander Installation Guide

HygroClip DIGITAL Humidity and temperature probe

midi LOGGER 900 SERVICE MANUAL GL900-UM-251 GL900-UM

ADC7520 SERIES. 1600W Battery Chargers and Power Supplies

DX4085 Z-Meter Tester

DPM Bi-directional Digital DC Power Meter with built-in USB data logger & adapter External shunt model. User Manual

adaptiverf IMPL-10 Wireless IP Bridge User Guide expertise in wireless design June adaptiverf Ltd Preliminary DS-IPML-10-1V0 Page 1

QUALITY POWER SOLUTIONS BACKED UP BY REAL-WORLD ENGINEERING EXPERIENCE

User's Guide. MiniTec TM Series Model MN25 MultiMeter

Model OI-9100 Signal Strength Meter The View

midi LOGGER 820 GL820-UM-251

Hygro-Thermometer / Datalogger

IQ21x Series Controllers

DEUTSCH ENGLISH NEDERLANDS FRANÇAIS NORSK ITALANIO ČEŠTINA Hersteller DAB650SI

IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS

EL-WiFi-TH -

The PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.

BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual

Datalogging Conductivity/ TDS Meter. Instruction Manual

midi LOGGER 200 SERVICE MANUAL GL200-UM-251 GL200-UM

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

USER MANUAL Video Particle Counter with built in Camera Model VPC300

Mini Digital Multimeter

midi LOGGER 220 GL220-UM-251

Mini Digital Multimeter

Formaldehyde Thermo-Hygrometer

HOLDPEAK Sound Level Meter Instruction Manual

Tinytag Thermohygrometer User Guide

Hercules GENII Screw mount 2in1 450MHz and 868MHz (Separate cable and connectors)

PIECAL 322 Automated Thermocouple Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

HUMLOG 10. Manual. Status V4 (02/2010)

2 in 1 LAN Tester and Multimeter Model:

USB-500/600 Series Low-Cost Data Loggers and Accessories

FILTER NAME CONSTRUCTION FEATURES APPLICATIONS ORDER CODE MEMBRANE Body: polycarbonate Filter: PTFE membrane

S-14 S-14. Compact Digital Multimeter. Compact Digital Multimeter

Features. IDS : Inclinometer Display System with RS232 Output

smartentry Wireless Video Doorphone User Manual

Heat Stress WBGT Meter

TITAN S8. Portable Data Acquisition Logger. Product User Guide

CO, NO, NO 2, NO x, SO 2, CH 4, HCl, N 2 O, CO 2 & H 2 O

Mini Digital Multimeter Model MN15. User's Guide

TES-1353S INSTRUCTION MANUAL

HCS-3600 / 3602 / 3604 Laboratory Grade & High RFI Immunity Switching Mode Power Supply with Rotary Encoder Control

IP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

Sound Level Meter SD Card real-time Datalogger

Model HM-535 Power Supply Installation and Service Instructions

OPERATION MANUAL. separate probe, RS-232 SOUND LEVEL METER. Model : SL-4013

DPM-3221 Digital DC Power Meter with data logging capability.

Product Catalog. Belgium Tel.: +32 (0) The Netherlands Tel.: +31 (0)

ON/OFF HUMIDIFIER CONTROL (ROOM 0R DUCT SENSOR) WITH OUTDOOR TEMPERATURE RESET OVERVIEW WALL CONTROLLER INSTALLATION (TCY-BH-T-U)

SensorWATCH Basic RH - Wireless Setup Users Help Guide Part Number: A Revision: 1.1.0

DMT345 and DMT346 Dewpoint Transmitters

Really Performs! Here is a Hand-Held Data Logger that Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440)

SIM-9106/9303 High Current Switching Mode Power Supply with C.C., C.V., Remote Control & Sensing User Manual

Autoranging True RMS Multimeter User Manual

5.8GHz Wireless Microphone System VmicLink5

12-Channel Thermocouple Datalogger

SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER

WIRELESS SERIES Single or Dual Axis MEMS Inclinometer

STEREO Bluetooth H e a d s e t S u n g l a s s e s V2.1+EDR User Guide MV SUNGLASSES SERIES

HOBO Motor On/Off Data Logger (UX90-004x) Manual

HCC-CW-201A. CWDM Analyzer. Operation Guide

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY

ph/orp Meter SD Card real-time Datalogger

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

TAPR GPS Kit USER S GUIDE

CDD4 Duct Carbon Dioxide Transmitter

Carbon Dioxide Monitor Instruction Manual

USER GUIDE. Video Particle Counter with built in Camera. Model VPC300

Moisture Content Meter Plus Dew Point, Wet Bulb, and Thermocouple Temperature functions

OPERATING INSTRUCTION

IntesisBox PA-AC-MBS-1

DIGITAL SOUND LEVEL METER. Instruction Manual

RMS Mini Wireless Data Logger

1PH RACK 19 SINGLE PHASE UPS Rev. 11 SR 6kVA 10kVA

KS-SB200 BOOM BOX INSTRUCTIONS LVT B [J]

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

Features: DSB98 v1.0 DIN rail mounted switch 9-port DSB98 with buffer power supply for 8 IP cameras

MIRRIN. Multi-Channel Load Logger MODEL: LL400 User Manual 1 GETTING STARTED INTRODUCTION CONNECTIONS

PM2.5 and PM10 Monitors , & Instruction Manual

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

24-Port Gigabit Ethernet Switches

2YL-T15-4M & 2YL-T16-4M Thermocouple Loggers. 2YL-M36-4M & 2YL-M37-4M Multi Terminal Input Loggers. 2YL-M61-4M & 2YL-M62-4M Lux Loggers

QUEST Portable PA Units

GA-12. madur Polska sp. z o.o.

FROG-4000TM Quick Start Guide

Trend-1 Vibration Data Logger. User Manual

LRC-XDP. LRC-XDP Datasheet. LRC-XDP Display Panel for Toshiba air-conditioning units. Description

ENVIRONMENTAL MONITORING & CONTROL

BC-9000 Field Calibration Procedure CF1_FIELDCAL_BC9000 Revised 03/16/2013

Switched Mode Power Supply Operating manual PAP800

Installation of the PCMeasure Movement Sensor (30114)

Transcription:

Eltek TU1082 - GenII AQ110A comprehensive portable air quality monitor transmitter AQ110A (serial number 32655 onward) is part of the Eltek GenII family of transmitters and can be used alongside any other Eltek GenII transmitter. AQ110A is a comprehensive portable air quality monitor for primarily indoor use. (For outdoor use a secondary enclosure (type WBT/AQ) must be used - P.O.A,refer to Eltek). The compact monitor is normally AC mains powered. A built-in Li-ion rechargeable back-up battery is included. The internal sensors are: 1 x CO 2 0/5000ppm 1 x CO 1 x NO 2 1 x VOC 3 x Particulate sizes and airflow 1 x DC voltage input - for use with an analogue out from a sound pressure level meter 1 x External supply monitor 1 x Temperature within the enclosure In addition there is a case-mounted RH and temp sensor with renewable filter. Sensors are plug-in (except the CO sensor) to 2 facilitate ease of calibration and maintenance. The particulate sensing module incorporates a pulsed fan unit to precisely control the volume of air per sample and ventilate the enclosure to ensure a flow of air across the various sensors. AQ110A The robust polycarbonate enclosure is fitted with left and right hand side ventilation (exhaust) apertures. Each ventilation hole is fitted with a non-renewable 100 micron stainless steel mesh filter. The ventilation holes should never be obscured - doing so can affect the measured values from the various sensors. The unit should be located in a cool, dry, non-hostile place and away from any risk of water ingress. The unit environmental rating is IP20. AQ110A is supplied with a miniature detachable antenna. The antenna should remain installed at all times. Page 1

Frequency: Compliant to: Operating temperature: Operating humidity: Transmitter power: DC input voltage and connector type: Number of user physical inputs: Number of incorporated sensors: Number of parameters presented: Dimensions (ex antenna and RH/Temp probe): Environmental rating: Weight (excluding MP12U power supply/charger): AQ110A common Specification Measuring Range and transmitter channel allocation A Temperature -30.0 to 65.0 C Resolution: 0.1 C Accuracy: ±0.2 C at 20 C ±0.4 C for 5 to 40 C ±1.0 C for 20 to 65 C B RH 0.0 to100.0% Resolution: 0.1% Accuracy: ±2% RH (0 to 90% RH) ±4% RH (0 to 100% RH) C CO2 0-5000ppm Accuracy: < ±50 ppm, +3% from measured value Temperature dependence: typically 2ppm/ C for temp range 0 to 50 C Long term stability: 20ppm per year Operational range: -10 to 50 C, 5 to 95% RH non condensing. D Particulate PM 0-1 µm particle count (0.00 to 500.00 µg/m3) E Particulate PM2.5 1-2.5 µm particle count (0.00 to 500.00 µg/m3) F Particulate PM10 2.5-10 µm particle count (0.00 to 500.00 µg/m3) G Airflow 0.00 to 500 ml/s H* NO2-0.1000 to 3.0000 ppm (For range 0.000 to 3.0000 ppm refer to Eltek) I* CO -5.00 to 500.00 ppm (For range 0.00 to 500.00 ppm refer to Eltek) J VOC 0.00 to 50.00 ppm K DC voltage scaled: 0.00 to 130dB L DC (External supply voltage) 0.000 to 20.000VDC 434.225Mhz EN300 220-1 -10 to +55ºC 0-90 %RH non condensing 10mW ERP 12VDC ±1V (reverse polarity protected) 1 x 3.5mm jack for use with SPL 8 15 (H198 x W120 x D88)mm IP20 850g Principle of operation: Sensors are read sequentially, typically every 18 seconds and the resulting values are stored. These values are then sent in the next transmission. Note that the CO2 sensor value is updated every 15 seconds irrespective of the 18 second cycle. For GenII principle of operations see section 2 of the GenII manual, which can be found on the Eltek website. *Settle time is 24 to 48 hours after power-up. Please allow for this if the unit has been in storage. Page 2

RH and temp probe with renewable filter. Eltek part no. FIL005 Ventilation aperture with 100 micron stainless steel mesh filter. An identical ventilation aperture is installed on the AQ110A left hand side. External 12VDC input. Use only MP12U power supply provided. Outer is +12VDC, inner is negative. 3.5mm jack socket - connect to SPL output See below for recommended SPL (Sound Pressure Level) meter Particulate sampling input - do not obscure or insert any object AQ110A right hand side Back-up battery endurance and charging The battery type is ELAQ110 Li-ion and is available only from Eltek Ltd. Use only charger type MP12U provided with the AQ110A. Do not attempt to use any other charger or car battery adaptor as this may cause damage to either the AQ110A or the charging device itself. A fully charged battery will provide 24 hours of operation. Charge time is approximately 8 hours and is automatic. The LCD battery gauge indicates the state of charge of the battery. Battery disposal Batteries should be disposed of responsibly and in accordance with local regulations. Recommended SPL (Sound Pressure Level) meter The Extech 407750 Type 2 Sound meter provides a mv DC output (10mV /db). The 407750 is for community noise measurement / noise ordinance applications. The measurement range is 30 to 130dB. The meter provides A or B weighting. The 407750 is battery operated and can be powered by an external 9V DC supply. The 407750 is connected to the AQ110/AQ110A analogue input using a standard 3.5mm to 3.5mm stereo jack lead (not included with AQ110/AQ110A or Extech 407750). The Extech 407750 can be sourced form various web sites or from Eltek (P.O.A) if preferred. Page 3

AQ110A Main components - top cover removed Compressed spring antenna leave attached at all times. Antenna connector. Type: SMA RH and Temp sensor with renewable membrane filter, Eltek part no FIL005 The LCD includes a battery condition gauge active at all times: Only configured channels are displayed. The LCD scrolls through the configured channel values. Li-ion rechargeable battery Type: ELAQ110 Li-ion Battery connector Orientate as indicated. NO2 sensor Not used CO sensor VOC sensor Location type and serial number plate. Also affixed to rear of unit. SW1 D1 comms D12 D13 RJ45 transmitter firmware configuration. Engineering use only. SW1: see table below LED D1: see table below COMMS: 3.5mm jack socket for AQ110 configuration. Use lead type LCTX3 only. LED D13 (Green): Fast charge in progress LED D12 (Red): charge error CO2 Sensor with PTFE filter. Particulate counting module is attached to the side of the enclosure with pendant from PCB. Do not obscure venting port. one of four fixing holes " The front cover is retained by 4 semi-captive fixing screws. " The front cover must be securely fitted to ensure the rubber seal is effective. The AQ110A can be free standing (portrait mode only) or wall mounted using the 4 fixing holes obscured when the front cover is fitted. " The front cover must be fitted during sustained operation. " There are no user adjustments for AQ110A Function of SW1 and D1 Function Activate SW1 for: D1: Led flash rate LCD Tx disable 5 seconds 5 x fast flashes After 5 seconds display OFF Tx enable 5 seconds 1 x continuous 5 second flash After 5 seconds displays sensor information Test: transmits approximately every 5 sec for 2 minutes 1 to 2 seconds No indication No change Page 4

AQ110A configuration using Darca software Refer to the GenII Quick start guide (ref TU1008). This is supplied with the RX250AL or can be downloaded from the Eltek website. Connect the LCTX3 to the Comms socket. Don't forget to set up the logger interval first! Before setting Tx channels please set the TX Interval: All Tx channels A to O have fixed ranges. Select as appropriate, set the channel and then meter to check readings. Channels M, N and O are included for customer data processing purposes. Note Alarms cannot be configured in Tx Set up for AQ110A. If required Alarms can be configured in the Darca software. Notes: Channels when set to active are assigned to the next available channel of the logger. (Channel allocations can be reassigned using Darca software) Channel K is pre-configured for use with the a Sound Pressure Level meter for the range 0 to 130dB. (a suitable SPL is type Extech 407750, available from PASS or refer to Eltek.) Once the AQ110 is configured, to close, click on Next transmitter or Send to Squirrel and follow the on-screen prompts. If all 15 channels are used, the AQ110A will only work with SRV250 and RX250AL units serial numbers after EL-12192. For use with SRV250 or RX250AL prior to this serial number, 14 or less channels should be enabled on the AQ110A. If required SRV250 or RX250AL can be upgraded - P.O.A from Eltek Ltd. Page 5

Powering down AQ110A if to be stored for less than one month It is recommended that after each period of use or if the unit is to be stored for less than one month, the following power down procedure should be used: 1. Put AQ110A on charge for at least one hour (to ensure battery 20% charged) 2. Remove front cover. Remove the charger lead (AQ110A will not switch off if external power is applied) 3. Press SW1 for 5 seconds. DI will flash 5 times. 4. Check LCD displays OFF 5. Refit front cover. Powering down AQ110A if to be stored for more than one month It is recommended for extended storage (no use for more than one month), the following power down procedure should be used: 1. Put AQ110A on charge for at least two hours (to ensure battery is reasonably charged) 2. Remove front cover. Remove the charger lead (AQ110A will not switch off if external power is applied) 3. Unplug battery connector from motherboard. 4. Refit front cover. BAT Battery connector Location of SW1 and D1 Next time the AQ110A is to be used Remove front cover, then do the following: If battery is disconnected: 1. Reconnect battery - please observe polarity! AQ110A will immediately boot up. 2. Connect MP12U charger 3. Check LCD runs through self check, serial number and version number before cycling through sensor values. Note that only channels previously set up in Darca will be displayed. 4. Securely refit front panel. If battery is already connected and partially charged 1. Plug in charger 2. Press SW1 for 5 seconds (D1 will illuminate for 5 seconds) 3. Check LCD runs through self check, serial number and version number before *cycling through sensor values. Note that only channels previously set up in Darca will be displayed. 4. Securely refit front panel. If battery is connected but discharged 1. Plug in charger and wait - in about 20 seconds, the AQ110A will then boot up where LCD runs through self check, serial number and version number before cycling through sensor values. Note that only channels previously set up in Darca will be displayed. 2. Reconnect battery - please observe polarity! 3. Securely refit front panel. Note: Do not connect charger if the battery is disconnected. (End of User Instructions) TU1082 31-08-18 Page 6