ECLYPSE Communication Modules

Similar documents
ECLYPSE Communication Modules

ECLYPSE Connected System

ECLYPSE nlight Solution

ECLYPSE Connected System Controller

ECLYPSE Connected System Controller

ECLYPSE Connected System Controller

Allure EC-Smart-Comfort Series

Allure EC-Smart-Comfort Series

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

ECLYPSE Connected Equipment Controller

Overview. Seen as an extension of the main HVAC controller when configuring, allowing you to save engineering time.

ECLYPSE Connected Terminal Unit Controller

Datasheet. ECB-PTU Series. 1/14. BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

ECB-VAVS. Features and Benefits. Applications Cooling Only VAV Boxes Cooling with Reheat VAV Boxes Room Pressurization.

BACnet B-ASC Powered Terminal Unit Programmable Controllers. Overview

Specification Sheet For electronically commutated motors

Datasheet ECB /6. BACnet B-ASC 10-Point Programmable Controller. Overview

ECB-203 Series BACnet B-ASC 14-Point Programmable Controllers

Overview. Integrated fail-safe mode in case of communication or power failure to comply with most regulation requirements

ECB-300 Series BACnet B-AAC 18-Point Programmable Controllers

ECLYPSE Connected Terminal Unit Controller

Datasheet. ECB-600 and ECx-400 Series. ECB-600 & ECx-400. Overview. Applications. Features & Benefits.

Priva Blue ID Communication module RS485 SC44

Datasheet. ECB-203 Series. 1/6. BACnet B-ASC 14-Point Programmable Controllers. Overview

ECLYPSE Connected VAV Controller

Priva Blue ID Communication module RS232 SC22

EC-BOS-8 Multi-protocol Web Building Controller

Datasheet. ECB-300 Series. 1/6. BACnet B-AAC 18-Point Programmable Controllers. Overview

EC-BOS-8 Multi-protocol Web Building Controller

ECB-VAV BACnet B-ASC VAV Controller

ECLYPSE Connected Terminal Unit Controller

ECLYPSE Series Connected IP and Wi-Fi Product Series and Accessories

ECP-VAV Series. ECP-VAV Series. 10-Point Single Duct VAV / VVT Free Programmable Controller. Applications. Features

ECB-VAVS and ECB-VAV Series

LN Series Remote Input/Output (I/O) Modules

Blue ID Communication module RS485 SC44

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

ECP-PTU Series. ECP-PTU Series. 14-Point High-Voltage Programmable Power Terminal Unit Controller. Applications. Features

Priva Blue ID Relay output module DOR4/DOR8

Priva Blue ID Digital input module DI4/DI8/DI16

IntesisBox Modbus Server Panasonic

Power supply module, bus connection module

Priva Blue ID Network module SN1/SN2/SN3/SN3t

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

FX-PCX Expansion Input/Output Modules Catalog Page Code No. LIT Issued April 17, 2015

Modbus Server SIEMENS Algorex (printer port)

BACnet /IP to MS/TP Adapter User Guide

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

DOR6. Components All functions and indications are on the front of the module. Characteristics

Blue ID Power injection module PI60

Output Signal. 22DTM-16 BACnet DC V, DC V. Electrical data Power Supply DC V, ±10%, 0.3 W

Smart Equipment Controls (SEC)

Priva Blue ID Analogue output module with manual override AO2m/AO4m

ICD105A 1008 page 1/ r001 ICD105A. Industrial RS-232 to RS-422/485 Converter

IntesisBox Modbus Server - BACnet/IP Client

ECL-VAV LONMARK Certified VAV Controller

ECL-103 LONMARK Certified 10-Point Programmable Controller

Datasheet. ECB-VAV Series. 1/8. BACnet B-ASC Single Duct VAV / VVT Controllers. Overview

Island bus expansion module

Installation Instructions for UL Rev A

Rugged Industrial Media Converter

Modbus Server - M-Bus (EN ) Gateway for the integration of M-BUS meters with Modbus RTU and TCP based control systems.

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

Technical data sheet. PowerLogic power-monitoring units EM3500 series DIN Rail meter

Datasheet. ECB-VAV Series. 1/8. BACnet B-ASC Single Duct VAV / VVT Controllers. Overview

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

clarity 3 Programmable Controller

IntesisBox Modbus Server - Honeywell XLS 80

Priva Blue ID C-Line system overview

Airflow Pressure Sensor

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

IntesisBox BACnet IP Server - M-Bus

Datasheet. BACnet PFC Demo Case. 1/8. Distech Controls BACnet solution demo case. Overview

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

ECL-400 Series LONMARK Certified 24-Point Programmable Controllers

PG AA Modbus RTU to SNMP Protocol Converter

Fall 2015 Release: Now Shipping!

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

LX Series Remote Input/Output (I/O) Controller

IntesisBox KNX - BACnet/IP Client

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

Electrical network management. Schneider Electric. EM4200 Technical Datasheet

DIRIS Digiware D and C Communication and control power interfaces

TALON Network Manager- 2 & 6 Express

CONTROL MICROSYSTEMS SDI-12 Interface Module. Hardware Manual

IntesisBox Modbus Server M-Bus

TM172PBG42R Modicon M172 Performance Blind 42 I/Os, Ethernet, Modbus

MED102A. Industrial Serial to Single-mode Fiber Converter

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Allure EC-Smart-Vue Sensor Series

Web interface BACnet/IP

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Room automation station

Extension module for graphic Web functions for one automation station

Now available to pre-order from Distech Controls

[SmartX Controller ] Introduction. Features. SmartStruxure solution

LNP-800AGH-24 Series. Features INTRODUCTION DIMENSIONS

Transcription:

Datasheet ECLYPSE Communication Modules Overview Features & Benefits Communication modules enable ECLYPSE Connected Controllers to communicate with a variety of devices. Scalable and Modular An ECY-RS485 communication module adds two extra RS-485 trunks to support more BACnet MS/TP and Modbus RTU devices. An ECY-MBUS communication module adds one M-Bus port to support and power up to 60 M-Bus meters. Applications Seamless integration with third-party HVAC equipment through Modbus or BACnet MS/ TP Data collection from various types of meters When equipped on the ECY-S1000 the communication modules use its recurrent power supply concept, which can be used when more power is required to power a series of I/O modules. A 100 to 240VAC power supply module eliminates the need for a line voltage to 24VAC power transformer to save installation costs and time. A 24 VAC / VDC power supply module is equally available. A connecting cable is used to connect successive rows of modules within a controls cabinet to provide power and communication. ECY-RS485 communication module An ECY-RS485 communication module adds two extra RS-485 trunks to support more BACnet MS/TP and Modbus RTU devices. ECY-MBUS communication module An ECY-MBUS communication module has one M-Bus port to support up to sixty meters and power the M-Bus bus.

Multi-Protocol Support Multiple communication protocols, like BACnet/ IP and Modbus, make it easier to integrate into existing building automation systems and add functionality for edge applications such as metering. Programmability Supports Distech Controls EC-gfxProgram, which makes Building Automation System (BAS) programming effortless, by allowing you to visually assemble building blocks to create a custom control sequence for any HVAC, lighting, or building automation application. ECLYPSE Web Configuration Interface Compatibility Easier communication module setup through the same web interface as the ECY-S1000. Ease of Installation The communications modules are plug & play devices. They are equipped with HD-15 connectors that transmits power and communications to the next module for fast and easy assembly. Status LEDs The status LEDs on the communications modules allows the user to confirm the status of the inputs/outputs and facilitate commissioning and troubleshooting. 2 / 6 ECLYPSE Communications Modules

Model Selection ECY-RS-485 Model Selection Communication Module ECY-RS485 Description ECLYPSE Communication module with two RS-485 ports for Modbus RTU or BACnet MS/TP with an ECY-CSC module. ECY-MBUS Model Selection Communication Module ECY-MBUS Description ECLYPSE Communication module with one M-Bus port, supporting up to 60 M-Bus meters when connected to an ECY-CSC, or up to 3 meters when connected via USB to an ECY-VAV, ECY-303, or ECY-TU/PTU. ECLYPSE Communications Modules 3 / 6

Product Specifications Supported Quantity RS485 Communication Module (ECY-RS485) Supported Quantity Power Supply Input 1 x ECY-RS485 or 1 x ECY-MBUS per ECY-CSC 1 x ECY-MBUS per ECY-VAV, ECY-303 or ECY-TU/PTU 1 ECY-RS485 per ECY-CSC Voltage 18VDC; Class 2 Power Consumption Communications Supported BACnet MS/TP or Modbus RTU Connectivity: 1.5 W BACnet MS/TP or Modbus RTU 2 RS-485 serial communication ports Each RS-485 port supports one communication protocol at a time RS-485 Wiring 1-pair + Common/shield Connection Type Screw terminals RS-485 EOL Resistor Built-in RS-485 Baud Rates 9600, 19 200, 38 400, or 76 800 bps RS-485 Addressing Controller s Web Configuration Interface Status Indicators Mechanical Dimensions (H W D) 3.20 [81.17] 2.31 [58.56] Inter-Connection Gap: 0.01 [0.40] Green LED: TX Orange LED: RX 4.74 3.16 2.31" (120.31 80.19 58.56mm) 0.51 [12.90] 0.83 [21.08] RX1 TX1 RX2 TX2 4.74 [120.31] 3.18 [80.82] 5.30 [134.65] 0.73 [18.54] 0.06 [1.44] Front 2.95 [74.99] Profile Back Inches [Millimeters] Shipping weight Mounting Enclosure Material Enclosure Rating 1 0.55lbs (0.25 kg) DIN rail or screw mounting FR/ABS Plastic housing, UL94-V0 flammability rating 1. All materials and manufacturing processes comply with the RoHS directive and are marked according to the Waste Electrical and Electronic Equipment (WEEE) directive Environmental Operating Temperature 32 to 122 F (0 to 50 C) 4 / 6 ECLYPSE Communications Modules

Storage Temperature Relative Humidity -22 to 158 F (-30 to 70 C) 0 to 90% non-condensing Ingress Protection Rating IP20 in accordance with IEC 60537 Nema Rating 1 Standards and Regulations CE: Emission EN61000-6-3: 2007; A1:2011; Generic standards for residential, Immunity EN61000-6-1: 2007; Generic standards for residential, FCC UL Listed (CDN & US) This device complies with FCC rules part 15, subpart B, class B UL916 Energy management equipment M-Bus Communication Interface Module (ECY-MBUS) Supported Quantity Power Supply Input Power Source Voltage Power Consumption Communications Supported M-Bus connectivity: 1 ECY-MBUS per ECY-CSC, ECY-VAV, ECY-303 or ECY-TU/PTU ECY-PS24 or ECY-PS-100-240 power supply module, or USB port 18V; Class 2 (when equipped) 5V; Class 2 (when connected via USB) 10W over 18V power supply 2.5W over USB M-Bus Ports 1x M-Bus serial communication port Supported M-Bus Meters 3 (USB), or 60 (ECY-MBUS60) M-Bus Wiring Terminals 2 M-Bus baud rates 300, 600, 900, 1200, 2400, 4800, and 9600 M-Bus Meter Addressing Configured in EC-gfxProgram Status Indicators Green LED: TX Orange LED: RX Green LED: POWER Red LED: MBUS Fault ECLYPSE Communications Modules 5 / 6

Mechanical Dimensions 4.74 3.20 2.31" (120.31 81.17 58.56mm) 3.20 [81.17] 2.31 [58.56] Inter-Connection Gap: 0.01 [0.40] 0.51 [12.90] L2- L1+ M-Bus 0.83 [21.08] POWER RX TX STATUS 4.74 [120.31] 3.18 [80.82] 5.30 [134.65] MBUS HOST 1x 0.73 [18.54] 0.06 [1.44] Front 2.95 [74.99] Profile Back Inches [Millimeters] Shipping Weight Mounting Enclosure Material Enclosure Rating 1 0.69lbs (0.31 kg) DIN rail or screw mounting FR/ABS Plastic housing, UL94-V0 flammability rating 1. All materials and manufacturing processes comply with the RoHS directive and are marked according to the Waste Electrical and Electronic Equipment (WEEE) directive Environmental Operating Temperature Storage Temperature Relative Humidity 32 to 122 F (0 to 50 C) -22 to 158 F (-30 to 70 C) 0 to 90% non-condensing Ingress Protection Rating IP20 in accordance with IEC 60537 Nema Rating 1 Standards and Regulations CE: Emission EN61000-6-3: 2007; A1:2011; Generic standards for residential, Immunity EN61000-6-1: 2007; Generic standards for residential, FCC UL Listed (CDN & US) This device complies with FCC rules part 15, subpart B, class B UL916 Energy management equipment Specifications subject to change without notice. ECLYPSE, Distech Controls, the Distech Controls logo, EC-Net, Allure, and Allure UNITOUCH are trademarks of Distech Controls Inc. BACnet is a registered trademark of ASHRAE; BTL is a registered trademark of the BACnet Manufacturers Association. The Bluetooth word mark and logos are registered trademarks owned by Bluetooth SIG, Inc. and any use of such marks is under license. All other trademarks are property of their respective owners., Distech Controls Inc., 2015-2018. All rights reserved. Global Head Office - 4205 place de Java, Brossard, QC, Canada, J4Y 0C4 - EU Head Office - ZAC de Sacuny, 558 avenue Marcel Mérieux, 69530 Brignais, France 6 / 6 ECY Comm EU_DS_11_EN