Safety module SM A3

Similar documents
Multifunctional with high performance. Browser based user interface. Universal interface design

LiftXpress. General Technical Description Köln Chester Business Park

FSO Webnair FSO Safety Functions Module. ABB Group February 11, 2015 Slide 1

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

AC SERIES LIFT CONTROLLER SYSTEMS AYBEY ELEKTRONIK

Gladiator Lift Services Ltd OPTIO MRL Controller Specification

OMRON PROGRAMMABLE CONTROLLER. Input terminals TIMER ADJUSTMENT

MSI-RM2 Safety Relays

Intrinsically safe batch controller Batching Master 110i

Ethernet-Gateway. Configuration. D Köln Chester Business Park

EM-F-7G Safety Extension Module

Operating Instructions

High Performance Tension Controller HPTC Electrical Connection Manual

MPK 411 DEVICE HANDBOOK

Safety Control Relay Product Catalog

Manual. Decentralized Extra-Low Voltage Servo Drive CMP ELVCD Functional Safety * _0717*

SMVector Additional I/O Module Installation and Operation Manual

DCP - Interface. Dynavert L. Technical Description July 2010 (Draft) Dynavert

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

HST -S1 Switching element (Translation of Original Manual)

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Controller CMXH. Description STO. Safe Torque Off (STO) [ ]

Making Hazardous Operations Safe and Productive

Two-hand relay modules SRB 201ZH 44 Schmersal Industrial switching systems

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC Functional Safety

HST -M2 Switching element with locking mechanism (Translation of Original Manual)

HST -M1 Switching element with locking mechanism (Translation of Original Manual)

Safety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E

SR101A. User Information for SR101A. Correct Use

Operating instructions Safety-monitoring module SE-304 C. 1. About this document. Content

Elo-1145-MSS-Zentraleinheit 471 M41 H31.book Page 1 Tuesday, September 6, :10 PM, Datum:

AS-i Safety Relay Output Module with Diagnostic Slave

VI - Safety techniques

Manual Control Unit GFC 32

Installation manual plugs and connectors with screw connection (16/32 A)

MANUAL Functional Safety

samos PRO MOTION SAFE MOTION Safe Speed, Direction and Position Monitoring for Machines and Plants.

PSR UC/ESAM4/3X1/1X2/B

Assembly and Operating Instructions. M2 module for BDC-i440 control units

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

Operating Instructions Wall saw WSE1217 USA

Assembly and Operating Instructions Door Control

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

Rotork Fairchild PAX1 Linear Actuator User s Manual

ILEA_IOM. Installation Instructions for ILEA electric actuators ILEA-Ax ILEA-Bx ILEA-Px ILEA-Qx TABLE OF CONTENTS

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

SMVector Additional I/O Module Installation and Operation Manual

* _1216* Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Electronic Motor DRC..

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

ZC Series Zone Monitoring Controllers

MSI-T Safety Relays. SAFE IMPLEMENTATION AND OPERATION Original operating instructions. make technical changes. We reserve the right to

Set up and verify the operation of basic motor starters. Understand the purpose of a separate control circuit.

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

APPLICATION CONTROL GUIDELINES. IntelliROL Power Supply PN Revision Date: March 15, 2017

SNO 4003 K plus. Areas of application for the unit. Connection circuit diagrams. Intended use. Competent persons. Equipment and functional description

SINAMICS SINAMICS G120. Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F. Function Manual Safety Integrated 07/2010

Operating Manual Linear actuators MC55/24 MC55/230 MC55Y MC65/24 MC65/230 MC65Y. March 2011 / / EN

SR103AM. User Information for SR103AM. Correct Use

HT-52 ASANSÖR KUMANDA KARTI (LİFT CONTROL CARD)

Operating instructions. Speed monitor D / / 2014

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

Manual Simatek Control Unit GFC 32

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Supplementary operating instructions for your air curtain system Controller TMC 500

MAIN CONTROL BOARD USER MANUAL V - 3.0

Mounting and System Description for SSZ-Safety-Switching-Rails

Installation Instructions

PRSU/5 Safety Interface Controller

Safety Relays 3TK2845 Multifunction Device

* _1017* Drive Technology \ Drive Automation \ System Integration \ Services. Revision. MOVIPRO SDC With PROFINET Interface

BMF400 Input/output module

Application Examples for Planning/Configuring Safety-related Equipment for Machines and Plants. BA /2007 Subject to technical modifications

Operating Manual -ENGLISH- Page 1 KWG-ISO

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Type Switching repeater. Safety manual

Programmable Safety Systems PSS-Range

Operating instructions Fail-safe standstill monitor FWS About this document. Content

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

Sliding shutter control Aluminium shutters

Motor controller CMMS-AS-C4-3A-G2. Description. STO safety function (Safe Torque Off) b [ ]

ADAMCZEWSKI. Ordering data AD-STVEX 710 GVD Option: Factory-software configuration as per customer specifications.

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

MANUAL Functional Safety

Mounting and System Description for SSZ-Safety-Bumpers

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

PowerFlex 400 AC Drive Guide Specification

Brake checking signal for UCM compliance (EN A3)

Selection guide Preventa safety modules

Safety relays 3TK2845 multifunction device

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Safety relays C57x and C67xx range

Industrial motor controller for brushed DC motors 24 VDC

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

POWERDRIVE, PROXIDRIVE, VARMECA

LazerSafe LZS-003. Safeguarding System for Hydraulic Press Brakes. Mute point automatically determined, easily set and continuously monitored

ABB ABB 143 2CDC110004C0205. Safety relays. C57x and C67xx range. Content

PSR DC/ESP4/2X1/1X2

Transcription:

Kollmorgen Steuerungstechnik GmbH Kollmorgen Lift Controls Ltd. Broichstraße 32 Unit 2, The Office Village Cologne, Germany 51109 Chester Business Park Telephone +49 (0) 221 89 85 0 Chester, Cheshire, CH4 9QP Fax +49 (0) 221 89 85 30 Telephone + 44 (0) 1244-67 85 49 http://www.kollmorgen.de Fax +44 (0) 1244-68 15 78 Email info@kollmorgen.de Email info@kollmorgen.co.uk KOLLMORGEN Steuerungstechnik GmbH Köln / 11.06.2012 / DO_BASM01_a3_gb

Contents 1 Safety Instructions...3 1.1 The Operator s Duty of Care/Requirements of the Operating Personnel... 3 1.2 Explanation of the Safety Symbols Used... 3 1.3 Basic Safety Measures... 3 2 Intended Usage...4 3 Implementing the Protective equipment for in Case of UCM...4 4 Cross-Section of the Menu Functions...5 5 Lifts with Hydraulic Drive...6 5.1 Description of Their Function... 6 5.2 UCM Actuator Designed as a Block Valve... 6 5.3 UCM Actuator Designed as Redundant Lowering Valves... 7 5.4 SM01-001 Clamp Assignment... 7 5.5 Requirements from Using the UCM Actuator... 7 5.6 Start-Up... 8 5.7 The Test... 9 5.7.1 General Description of the Sequence... 9 5.7.2 Test Instruction... 9 6 Lifts with Frequency-Regulated Rope Drive...11 6.1 Description of their Function... 11 6.2 UCM Actuator Designed as an Intrinsically Safe Service Brake... 11 6.3 SM01-001 Clamp Assignment... 12 6.4 Requirements from Using the UCM Actuator... 12 6.5 Start-Up... 13 6.6 The Test... 14 6.6.1 General Description of the Sequence... 14 6.6.2 Test Instruction... 14 2 11.06.2012

1 Safety Instructions 1.1 The Operator s Duty of Care/Requirements of the Operating Personnel The operator has to: make the operating instructions available to personnel and be certain that the personnel has read and understood them. ensure that the subassembly is only used as intended. ensure that an skilled worker operates and services it. The term skilled worker is explained in the operating instructions on control in the Chapter on <<Personnel>>. 1.2 Explanation of the Safety Symbols Used danger This designates an immediately imminent danger to the life and health of personnel warning This designates a potentially hazardous situation. Persons might be killed or suffer very serious injuries if this warning is ignored. This is also a warning of dangers to machines, materials or the environment. note This indicates information that contributes to a better understanding of the machine s functions. procedure This gives the sequence in processes. example This contributes to a better understanding of the user input by giving parameters. 1.3 Basic Safety Measures working under voltage means DANGER to life and limb Disconnect the voltage supply (using the main switch or fuses) before doing service or cleaning work. Never remove or shut down safety equipment by modifying it. Comply with the specifications from DIN VDE 0100 and VBG 4. 11.06.2012 3

2 Intended Usage The SM01-001 subassembly has the purpose of monitoring two independent input signals and it is used as an electrical safety switch in controls for lifts in conformity with EN 81 Part 1 and Part 2 Item 14.1.2.3 TRA 264.2 Directive 95/16/EG Article 1, Paragraph 1, Article 8, Paragraph 1 It can also be used for monitoring unintended car movements of the elevator car from the stop (UCM: unintended car movement) if the shaft door is not locked and the elevator car door is not closed in conformity with DlN EN 81-1:2010-06 / 9.11 and DlN EN 81-2:2010-06 / 9.13 under the following conditions: 1. The drive is equipped with a braking device in conformity with DlN EN 81-1: 2010-06 / 9.11 or DlN EN 81-2: 2010-06 / 9.13. 2. The following operating states are observed: - the adjustment process is active in conformity with DlN EN 81-1/2: 2010-06 / 14.2.1.2 (i.e., the control has released adjustment). - the quick-start function is active in conformity with DlN EN 81-1/2: 2010-06 / 7.7.2.1 (i.e., the control has taken preparatory measures for moving the elevator car). 3. There is a monitoring contact available for rope drives on the regulator and MPK control for a speed of v < 0.2 m/s. 3 Implementing the Protective equipment for in Case of UCM There are UCMs when the monitor identifies an unintended movement of the elevator car away from the stop when the shaft and elevator car door are open. The protective equipment contains 3 basic components: 1. Monitoring the unintended movement of the elevator car away from the stop when the shaft door is not locked and the elevator car door is not closed. 2. Releasing the device if there is a UCM that stops the elevator car. 3. The device used in Item 2 (the UCM actuator). The SM01-001 safety switch complies with items 1 and 2 in combination with the MPK control taking the conditions described in Chapter 2 into consideration. 4 11.06.2012

4 Cross-Section of the Menu Functions Travel monitor UCM monitor monitoring YES Travel monitor UCM monitor fault clear? You can use this function to turn on UCM control monitoring. If the UCM control trips, the fault locks the control. You can only suspend this lock under <<Settings>> / <<travel monitor>> with the <<UCM monitor fault clear?>> function. RESETTING the control does not suspend the lock. Testing/Maintenance Completion UCM Assistance commissioning This function tests the presettings for the MPK control for the completion of a UCM check (also refer to Chapters 5.6 and 6.5). It checks the following presettings: clamp parametering for the functions: - <<Safety module>> input - <<Zone safety module >> input - <<Completion testing>> input - <<UCM Testrelais>> output..- <<Monitoring v<0.2m/s>> output (only with rope drive) the <<YES>> menu setting for the functions: - <<Settings>> / <<travel monitor>> / <<UCM monitor monitoring>> - <<Settings>> / <<Safety module>> / <<monitoring>> Testing/Maintenance UCM test nomi. speed Completion Travel Up= Down= UCM test Fl. 1 nomi. speed Distance: 876 mm You can use this function to give a travel command for the direction desired with the correct arrow key on the MPK control. The travel command is issued as long as the button is pressed. The distance covered is continually recorded and appears on the 4 th line. Testing/Maintenance Completion UCM test automatic self test You can use this function to carry out 10 trips in conformity with DlN EN 81-1/- 2:2010-06 / F.8.3.2.4 for checking the function of the equipment. NOTE You will find a detailed description of the processes for lifts with a hydraulic drive in Chapter 5.7 and for lifts with rope drive in Chapter 6.6. 11.06.2012 5

5 Lifts with Hydraulic Drive 5.1 Description of Their Function Two independent contact elements monitor resetting when the shaft and elevator car door is open. The mutually independent S71 and S72 zone switches are monitored in the SM01-001 safety switch for fault-free function with the aid of the, and relays. The monitoring switch between clamp 7 and clamp 12 of the SM01-001 safety switch checks to see whether these relays are in are proper switching condition. If relays and are antivalent, the flow of current to clamp 12 is disconnected in conformity with EN 81 Part 1 and Part 2 Number 14.1.2.3.2 (LED <<Status>> goes off). That means that the next start is hindered by the subsequent switch. The circumvention path (clamps 1 and 2) is closed in the zone area when resetting. When the doors are open, the contacts of the safety switch have an immediate effect on the travel contactors. If the elevator car leaves the zone area when resetting, the drive and UCM actuator are turned off immediately by interrupting the circumvention path (clamps 1 and 2). The MPK control identifies the UCM and shuts the lift down. It can only return to normal operation by manual reset with the control menu. NOTE To safely turn off the drive, comply with the conditions required at start-up (refer to Chapter 5.6) as well as the data for testing (refer to Chapter 5.7). The safety circuit also has the contact of the UCM test relay for testing purposes and this contact disconnects the safety circuit when testing with closed doors. Then the UCM test relay triggers the MPK control. 5.2 UCM Actuator Designed as a Block Valve 24 VDC Zone 71 Zone 72 230 VAC Passive safety circuit Safety circuit car gates Safety circuit landing lock contacts UCM Test Relais SM01-001 [2] [1] [3] [4] [12] 24 VDC [11] [8] [9] [10] MPK [E2] MPK [E3] MPK [A1] GND / 0V K11* K12* N Y1 Block valve (UCM-Actuator) MPK [E2], [E3], [A1] Default setting (real name see drawings) * Redundant activation drive (real name see drawings) Do_sm01-a3_gb.odg / 52% 6 11.06.2012

5.3 UCM Actuator Designed as Redundant Lowering Valves 24 VDC Zone 71 Zone 72 230 VAC Passive safety circuit Safety circuit car gates Safety circuit landing lock contacts UCM Test Relais SM01-001 [2] [1] [3] [4] [12] 24 VDC [11] [8] [9] [10] MPK [E2] MPK [E3] MPK [A1] GND / 0V MPK [E2], [E3], [A1] Default setting (real name see drawings) K11* K12* K98 K98A N * Redundant activation drive (real name see drawings) K98 / K98A Redundant activation lowering valves (real name see drawings) Do_sm01-a3.odg / 52% 5.4 SM01-001 Clamp Assignment Term. Bypass contacts, inputs zone Term. Inputs, outputs, 1, 2 Bypass safety circuit contacts door 10 Input relevelling 3 Input zone switch S71 11 Output zone safety module 4 Input zone switch S72 12 Output fault safety module 5.5 Requirements from Using the UCM Actuator the voltage supply for the actuator through the safety circuit...this means: it is not necessary to have redundant actuator triggering not through the safety circuit redundant triggering needed with standstill monitoring in series to the standstill monitoring of the drive contactors the function of the actuator in normal operation no function, only if there are UCMs...this means: not necessary to monitor the actuator function also in normal operation monitoring necessary for opening and closing the actuator with the control/regulation software 11.06.2012 7

5.6 Start-Up NOTE Please bear the fact in mind that you have to take the reaction and delay times into consideration for all protective equipment components (refer to Chapter 3) with UCMs to comply with the stop path from standard specifications there are other things that have an impact on the stop path such as the oil flowthrough quantity or drive acceleration. This is the reason why any stop path calculated from the manufacturer s data has to be checked locally on all levels and in both travel directions. you always have to observe the stop path based upon the worst-case assumptions such as by taking the drive s maximum acceleration and travel speed into account. Example calculation for the distance if there are UCMs based upon reaction and delay times distances and times parameters example fo v fast = 0.8 m/s door zone 0.05 0.2 m 0.2 m reaction time for the magnetic switch (Schmersal BP 325 / 65) 2 ms 2 ms x 0.8 m/s = 0.0016 m reaction time for the SM01-001 safety module 15 ms 15 ms x 0.8 m/s = 0.0120 m reaction time for the valves 15 ms 15 ms x 0.8 m/s = 0.0120 m delay time for the valves 45 ms 45 ms x 0.8 m/s = 0.0360 m result: 0.2616 m Start-up sequence: 1. Carry out start-up according to the specifications of the operating instructions for the SM01-001 control and safety switch. 2. Check to see that the presettings are on the MPK control; select the <<UCM Assistance Commissioning>> function in the menu under <<Testing/Maintenance>> / <<Completion>> (refer to Chapter 4). Start the test in the function by pressing the <<DOWN>> arrow button. Any conditions not met are shown in the menu during the test and should be provided. 8 11.06.2012

5.7 The Test 5.7.1 General Description of the Sequence The test starts from the flush position of the highest level in the downward direction and follows this sequence: the action of the control the reaction of the lift the doors close the safety circuit is closed activate SM01 safety switch safety circuit circumvention is active activate the UCM test relays the safety circuit is opened start the drive at rated speed the elevator car leaves the zone area SM01 safety switch trips safety circuit circumvention opens drive and valves switch off the control stores the fault fail-safe 5.7.2 Test Instruction Preparation: 1. Move the elevator car into the flush position of the highest level. 2. Set the <<Door blocking>> function to <<YES>> in the menu of the control under <<Testing/Maintenance>> / <<Presetting>>. 3. Connect the <<Completion testing>> input with +24V (such as clamp 200). Completion UCM TEST: 1. Select the <<UCM test nomi. speed>> function in the menu of the control under <<Testing/Maintenance>> / <<Completion>>. 2. Press the <<Down>> arrow key to give the travel command in the downward direction and hold the arrow key down until the UCM case triggers. 3. The <<UCM test nomi. speed>> function keeps you informed on the travel path travelled. 4. Check the travel path travelled in the level (the test was successful if the requirements from the standard EN 81-1 are met). 5. Reset the block of the control under <<Settings>> / <<travel monitor>> / <<UCM monitor fault clear?>>. Please remember that you have to reset downstream units. 11.06.2012 9

NOTE The following actuator tests (Part 1 and Part 2) are only necessary if a Manifold Blk Monitor is used. Completion actuator test part 1: 1. Select the <<UCM test automatic self test>> function in the menu of the control under <<Testing/Maintenance>> / <<Completion>>. 2. Control carries out 10 trips independently and tests valve feedback. Calling is blocked for the duration of the test. 3. The test was successful if no fault is reported during the 10 trips. Completion actuator test part 2: 1. Select the <<UCM test automatic self test>> function in the menu of the control under <<Testing/Maintenance>> / <<Completion>>. 2. Control starts a trip independently and tests valve feedback. Calling is blocked for the duration of the test. 3. Release the connection to a clamp of Manifold Blk Monitor as soon as control has started the drive. 4. The test was successful if the lift shut is down on the next level and it cannot make another trip. 5. Restore the connection to the clamp of the Manifold Blk Monitor. 6. Reset the control with RESET. Final actions: 1. Release the <<Completion testing>> input from +24V (clamp 200). 2. Set the <<Door blocking>> function to <<NO>> in the menu of the control under <<Testing/Maintenance>> / <<Presetting>>. 10 11.06.2012

6 Lifts with Frequency-Regulated Rope Drive 6.1 Description of their Function Two independent contact elements monitor resetting when the shaft and elevator car door are open. The mutually independent S71 and S72 zone switches are monitored for fault-free function in the SM01-001 safety switch with the aid of the, and relays. The monitoring switch between clamp 7 and clamp 12 of the SM01-001 safety switch checks to see whether these relays are in are proper switching condition. If relays and are antivalent, the flow of current to clamp 12 is disconnected in conformity with EN 81 Part 1 and Part 2 Number 14.1.2.3.2 (the <<Status>> LED goes off) which means that the next start is hindered by the subsequent switch. The circumvention path (clamps 1 and 2) is closed in the zone area when resetting. When the doors are open, the contacts of the safety switch have an immediate impact on the travel contactors. If the elevator car leaves the zone area during resetting, the drive and UCM actuator are turned off immediately by interrupting the circumvention path (clamps 1 and 2). The MPK control identifies UCMs and shuts the lift down and it can only return to normal operation by manual reset in the control menu. NOTE Bear the conditions required at start-up in mind for safely turning off the drive (refer to Chapter 6.5) as well as the data for testing (refer to Chapter 6.6). The safety circuit also has the contact of the UCM test relay for testing purposes and this contact disconnects the safety circuit when testing with closed doors. Then the UCM test relay triggers the MPK control. 6.2 UCM Actuator Designed as an Intrinsically Safe Service Brake V < 0,2 m/s Frequency inverter 24 VDC Zone 71 Zone 72 230 VAC Passive safety circuit Safety circuit car gates Safety circuit landing lock contacts UCM Test Relais SM01-001 [2] [1] [3] [4] [12] 24 VDC [11] [8] [9] [10] MPK [E2] MPK [E3] MPK [A1] V < 0,2 m/s control GND / 0V MPK [E2], [E3], [A1] Default setting (real name see drawings) K11* K12* Y7A Y7B N * Redundant activation drive (real name see drawings) Y7A / Y7B Coil of the brakesystem (real name see drawings) Do_sm01-a3.odg / 52% 11.06.2012 11

6.3 SM01-001 Clamp Assignment Term. Bypass contacts, inputs zone Term. Inputs, outputs, 1, 2 Bypass safety circuit contacts door 10 Input relevelling 3 Input zone switch S71 11 Output zone safety module 4 Input zone switch S72 12 Output fault safety module 6.4 Requirements from Using the UCM Actuator the voltage supply of the actuator...this means: through the safety circuit it is not necessary to have redundant actuator triggering not through the safety circuit redundant triggering needed with standstill monitoring in series to the standstill monitoring of the drive contactors the function of the actuator in normal operation no function, only if there are UCMs...this means: not necessary to monitor the actuator function also in normal operation monitoring necessary for opening and closing the actuator with the control/regulation software 12 11.06.2012

6.5 Start-Up NOTE Please remember that you have to comply with the reaction and delay times of all components of the protective equipment (refer to Chapter 3) if there are UCMs for meeting the stop path from the standard specifications other things have an impact on the stop path such as the drive acceleration. This is the reason why any stop path calculated from the manufacturer s data has to be checked locally on all levels and in both travel directions. you always have to observe the stop path based upon the worst-case assumptions such as by taking the drive s maximum acceleration and travel speed into account. Example calculation for the distance if there are UCMs based upon reaction and delay times distances and times parameters example fo v fast = 1.6 m/s door zone 0.05 0.2 m 0.2 m reaction time for the magnetic switch (Schmersal BP 325 / 65) 2 ms 2 ms x 1.6 m/s = 0.0032 m reaction time for the SM01-001 safety switch 15 ms 15 ms x 1.6 m/s = 0.024 m reaction time for the brake protection 15 ms 15 ms x 1.6 m/s = 0.024 m reaction time for the regulation v< 0.2, m/s 15 ms 15 ms x 1.6 m/s = 0.024 m result: 0.2752 m Start-up sequence: 1. Carry out start-up according to the specifications of the operating instructions for the SM01-001 control and safety switch. 2. Check to see that the presettings are on the MPK control; select the <<UCM Assistance Commissioning>> function (refer to Chapter 4) in the menu under <<Testing/Maintenance>> / <<Completion>>. Start the test in the function by pressing the <<DOWN>> arrow button. Any conditions not met are shown in the menu during the test and should be provided. 11.06.2012 13

6.6 The Test 6.6.1 General Description of the Sequence The test starts from the flush position of the highest level in the downward direction and follows this sequence: the action of the control the reaction of the lift doors close the safety circuit is closed activate SM01 safety switch safety circuit circumvention is active activate UCM test relays the safety circuit is opened start the drive at rated speed the elevator car leaves the zone area the SM01 safety switch trips safety circuit circumvention opens the drive and brake switch off the control stores the fault fail-safe 6.6.2 Test Instruction Preparation: 1. Move the elevator car into the flush position on the highest level. 2. Set the <<Door blocking>> function to <<YES>> in the menu of the control under <<Testing/Maintenance>> / <<Presetting>>. 3. Connect the <<Completion testing>> input with +24V (such as clamp 200). Completion UCM TEST: 1. Select the <<UCM test nomi. speed>> function in the menu of the control under <<Testing/Maintenance>> / <<Completion>>. 2. Press the <<Down>> arrow key to give the travel command in the downward direction and hold the arrow key down until the UCM case triggers. 3. The <<UCM test nomi. speed>> function keeps you informed on the travel path travelled. 4. Check the travel path travelled in the level (the test was successful if the requirements from the standard EN 81-1 are met). 5. Reset the block of the control under <<Settings>> / <<travel monitor>> / <<UCM monitor fault clear?>>. Please bear the fact in mind that you have to reset downstream units. 14 11.06.2012

NOTE The following actuator tests (Part 1 and Part 2) are only necessary if brake monitoring is used. Completion actuator test part 1: 1. Select the <<UCM test automatic self test>> function in the menu of the control under <<Testing/Maintenance>> / <<Completion>>. 2. The control carries out 10 trips independently and tests brake feedback. Calling is blocked for the duration of the test. 3. The test was successful if no fault is reported during the 10 trips. Completion actuator test part 2: 1. Select the <<UCM test automatic self test>> function in the menu of the control under <<Testing/Maintenance>> / <<Completion>>. 2. Control starts a trip independently and tests brake feedback. Calling is blocked for the duration of the test. 3. Loosen the connection to a clamp of brake monitoring as soon as control has started the drive. 4. The test was successful if the lift is shut down on the next level and it cannot make another trip. 5. Restore the connection to the clamp of brake monitoring. 6. Reset the control with the <<Settings>> / <<travel monitor>> / <<brake monitor fault clear?>> menu function. Final actions: 1. Release the <<Completion testing>> input from +24V (clamp 200). 2. Set the <<Door blocking>> function to <<NO>> in the menu of the control under <<Testing/Maintenance>> / <<Presetting>>. 11.06.2012 15