powersplit...the network evolution!

Similar documents
Controllers for static or ventilated refrigeration units up to 2HP. Innovative Solutions for Cold Rooms. Technology & Evolution

New generation......continuity, innovation, design

Monitoring and Telemaintenance Web-Based System

Solutions for showcases and cold rooms

Refrigeration solutions Controllers for commercial refrigeration, food service and catering

EZ-HT / EZ-MT / EZ-LT. Electronic controllers for refrigeration units

boss The complete range for mobile-ready local supervision

pco sistema programmable controllers Technology & Evolution

HACCP WIRELESS RETROFIT SOLUTION

4-step Chiller and Heat Pump Controller

WING REFRIGERATION CONTROLLERS

ID-Digifrost Line ID-DIGIFROST LINE BROCHURE

Iso DIN. User Manual. 1 channel Earth Fault Monitoring

µc sistema the range T e c h n o l o g y & E v o l u t i o n

ECON-ZIP-BASE. ZIP Economizer Base Unit. Wiring Diagram USA CANADA LATIN AMERICA / CARIBBEAN

XR-CHC and XRB-CHC Refrigeration controllers with Bluetooth connectivity

100% electricity. Automatic transfer switch controllers ATL series

Power factor correction components Planet-SWITCH Planet-DIN Planet-LOGIC

Fast Route to Reliable Energy Savings ZIP Economizer

THERMOSTATS & CONTROLLERS

supernode Electronic controller for humidification Technical Leaflet Integrated Control Solutions & Energy Savings

XR100/500 SERIES: CONTROLLERS FOR NT, MT AND LT - RS485 OUTPUT

EWPC 901/A rel. 6/96 ing

Custom Controller Installation Instructions

EWRC 300/500 NT QUICK START. Controllers for static and ventilated cold rooms. English

ADXL Series SIMPLE, EFFICIENT AND SAFE MOTOR CONTROL

PlantVisorPRO. Plant supervision. Quick guide. Integrated Control Solutions & Energy Savings

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

Wing Watch Lite. Battery Monitoring System. User Manual

FM100 Fume hood monitoring system according to EN 14175

Product Family: Electro Mechanical Relays Number: AN-LC-008

EWPlus 961 EO Dispenser

Programmable controller MCX06C

Product Manual SZ2141

Data sheet MK 20 GR. Customized solution or off-the-shelf: The choice is yours!

Controllers for compressor racks with advanced energy saving. PN08 September 2016

BIO-PRO Standalone / Weigand fingerprint reader

User Guide. For controller on CXAO / RTXB heat pumps CGCM / CXCM 2 circuit units. CNT-SVU005C-GB Original instructions

AGATA C200 UK A/200N TARGHA 200. Installation Manual AGATAKIT C 200 UK

ICPlus 902. Electronic controller with 1 intervention point

PlantWatchPRO. supervisor for small-medium installations. User manual. High Efficiency Solutions

Digital Keypad Introduction

RGX COMMUNICATIONS GATEWAY

GUARDIAN ACCESS MODELS GDN.S.48.M24 & GDN.S.48.MS32 Integrated DC Power System & Battery -48VDC 500A 26.8kW

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

DC Cooling Unit MODEL : TDC 500A / TDC 300A

Environmental Chamber Programmer/Controller

MODBus RTU for AKOCAM and AKOPRO controllers

Electronic controllers for centralised air-conditioning units

our experience...your solution Controlling and Monitoring Gateway

TECHNICAL MANUAL WATER 300 C 5300 CV/06-00 GB

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

Valid for item nos.: (1-zone) (2-zone) (4-zone) (6-zone) HPS-C-Slot Hotrunner controllers Operating manual

with Backlight Graphic LCD Screen

Products no longer available

100% electricity. Power factor correction components

ID 974 DCC electronic controllers for forced air refrigeration units

Data sheet. MCX15B electronic controller MAKING MODERN LIVING POSSIBLE. REFRIGERATION & air CONDITIONING DIVISION. Danfoss Electronics spa

P216. Condenser fan speed controller. Product bulletin. Features

VARIABLE SPEED DRIVES

FrigoPack FU+ New Generation of Intelligent Refrigeration Inverters

ph/orp 300 (Cat. No ) MICROCOMPUTER BASED OPERATION MANUAL ph /ORP/ Temperature CONTROLLER Phone: , Fax:

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Temperature Controller (Heat Pumps)

User Guide. Multipipe Units CMAA / RTMA CNT-SVU004B-GB

RT4B-110V/12A RECTIFIER

REFRIGERATION AND AIR CONDITIONING. On Site Guide AK2-SC 255

MDC-20. Maximum Demand predictive Control. Description

LED Driver. Xitanium DRIVER. 180W A 0-10V Dimming with SimpleSet and Aux. Output XI180C125V200PSF1. Specifications. Enclosure.

ES Energy Saver Product Ranges 90Amp 6000Amp

Precision thermometer Model CTR5000

Operations Manual HP2000. With 9100 Controller. Self-Heated Oxygen Measurement System

KTD-125/ KTD-125P/125P-24 KTD-127/127W PTZ Receivers

FRICK QUANTUM HD UNITY SYSTEM CONTROLLER

FCA THE SOLLATEK FREOCOM

Universal Controller

SEZ7656R1045B / SEZ7656H1045B

Field selectable application type and room module series, via dip-switches on controller

EMPlus 600. Electronic digital indicator

Electronic controllers for small centralised air-conditioning units

DIGITAL METERING INSTRUMENTS DMG SERIES

CONTROL BALL VALVES WITH EQUAL PERCENTAGE CHARACTERISTIC 2010 NEW ELECTRICAL ACTUATORS

Ellard Product Instructions

RT4F-48V/50A-WAC RECTIFIER

ENGLISH EW961/971/974

Inverter W and 12500W

Programmable controller MCX06D

User Guide. Tracer CH535 Chiller Controller on models CGAX/CXAX. CG-SVU007B-GB Original instructions

IQ3/XNC M-Bus Master

INDEX OF CONTENTS 15.2 VIEW OPTION LANGUAGE... 37

FX05 Controller. FX05 Controller. Features and Benefits Compatible with standard BAS protocols. LON and N2Open plug-in comm.

Mercury 11-10PV Pack / Condenser Controller Installation & User Guide V6 or Higher

FX14 Field Controller

AIR CONDITIONING CATALOGUE

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

1. Introduction ALSPA MV DELTA

Programmable controller Type MCX06C

DIS-2 series Decentralised servo drive

UDC 1000 and UDC 1500 MICRO-PRO SERIES UNIVERSAL DIGITAL CONTROLLERS

High-Precision Pneumatic Pressure Controller Series CPC8000-L/-X

Transcription:

powersplit...the network evolution! Technology & Evolution

PST00VR100, PST00SR300, PJC 2 Hp PJS,Y 2 Hp PTS00LR200 powersplit is the new controller for multiplexed showcases with on-board compressors. Thanks to the continuous monitoring of critical events (HCCP), the local network, the connection to the supervisory and telemaintenance systems, the power relay outputs, the auxiliary terminal block on the board, the light sensor etc. this controller represents the TOP of the range for the management of the entire unit.

powersplit...total control! powersplit is not just a controller, but rather a range of products. It is available in configurations with 4 or 6 outputs, and with or without built-in clock. This means flexibility, the possibility to adapt the controller not only to a type of cabinet, but also to a series of cabinets that can then be differentiated according to the type of interface display, the HCCP management, the time-based defrosts and in general all the options featured on the controller, while exploiting the advantages of having just one intelligence for the entire range. powersplit is designed to reduce wiring and the related power components, with a consequent reduction in the management of product codes and inevitably costs. ll with the maximum reliability of a standard product. with Comply with UNI EN 441

With programming key The programming key allows the instrument to be programmed quickly, even when not powered, with the certainty of not having made errors. It reduces the number of product codes managed and allows the controller to be programmed in just a few seconds, even during the end-of-production testing phase. This is an important tool also for the service network. Light sensor n absolutely new feature in refrigeration! This measures the variations in light inside the refrigerated compartments, thus allowing the controller to activate the functions featured as a response to the opening of the door. This represents a significant advantage, considering that just one sensor replaces a series of micro-switches on the doors. Local network connection and RS485 connection powersplit has been designed to manage plug-in showcases, and as standard offers serial connection to a local network. The advantages of the local network for optimising units with a number of sections are described on the following pages. By adding the RS485 option, the local network can be used for connection to a CREL remote supervisor and remote management system. Small display This terminal has the same appearance and drilling template (32x74 mm) as all the plug-in series controllers. The innovations have been introduced with this new-concept controller with the aim of maintaining the same feel for those who use the plug-in range of instruments. This is important both from an aesthetic and functional point of view, in that the users of this controller require very short time to fully exploit all the functions. Large display s well being aesthetic it is also very powerful digits, the keypad is m and is thus more ergon than the classic polyca are back-lit and easy to direct access to the fun light, defrost and conti display too can be eas customised using the r One very important de just 22 mm.

Power relay Power is the key word for this controller. The figures speak for themselves: 2 Hp compressor, 3200 W defrost, 70 peak for the light output, changeover alarm relay and auxiliary relay to control the other general functions. Built-in auxiliary terminal block Evolution not only means more software functions but also increasing integration between the electrical panel and control electronics. This is why the board features a complete power terminal block for the direct connection of the loads, including the earth connection, without requiring an external component for relaying the wiring. This means savings in time and surely less possibility of errors during the production phase.... team work! Display ally pleasing The display has 4 ade using silicon omic and reliable rbonate, the buttons use, thanks to the ctions, HCCP, uous cycle. This ily and economically emovable panel. tail is the depth: This can always be connected in parallel with the interface used to set the parameters. It can also display the temperature of the third probe located in the hottest point of the cabinet, as required by the standard EN441-13.

... team work! new, powerful tool: the local network With the powersplit you will discover the advantages offered by the local network in the management of your multi-section units. The powersplit local network is very simple to use: just connect 2 wires between the controllers that manage the various sections of your units. The powersplit local network, included as a standard feature, means less wiring and more rational management of the sections. With the local network, all the controllers can be centralised onto just one display. This means that when pressing the light button, the command is sent via serial connection to all the boards, which activate the light relay at the same time, all without additional wiring. The same is true for the ON/OFF, manual defrost, continuous cycle, and UX commands. The local network allows also the alarms from the different controllers, that is, from the different sections of the cabinet, to be centralised onto just one terminal. Furthermore, it allows defrosts to be synchronised: the defrosting of all sections starts at the same time and ends independently, according to the status of the different sections. The following refrigeration phase is started at the same time for all the sections upon completion of the defrost. For further information, please refer to the instruction manual....standards compliance Comply with EN 441 The European standard EN441-13 defines the criteria for measuring the temperature of refrigeration units. In particular, it establishes the characteristics of the instrument used to make the measurements in terms of precision, resolution, field of measurement and time constant. In addition, there are precise indications regarding the position of the temperature probe, which must be able to display the hot point (this does not normally coincide with the controlled temperature). The plug-in series controllers satisfy the requirements of this standard. The control temperature and hot point can be managed separately on the display of the unit. In the models fitted with a clock, HCCP management is standard! with This guarantees the temperature control of stored food products in compliance with the requirements of the HCCP system. The parameters are set directly in the instrument, and the limits of time and temperature required by the standards for stored food can also be set. The controller automatically monitors the unit, signalling any critical situations. It provides a warning signal if the set limits are exceeded, saving the main information to EEPROM (permanent memory). Furthermore, it signals power failures in the event where this affects the maintenance of the required temperature. ll the data can be easily read on the instrument, and the alarm events are signalled automatically.

up to 10 m PST display Display units up to 10 m PST small/large Display interface RS485 connection to supervisor connection to LN local area network T ambient S1 T defrost S2 suggested inside power connections T products S3 photo res. RX/TX- RX/TX+ GND GND RX/TX power (green) GND (red) RX/TX (white) GND (yellow) digital Input 1 digital Input 2 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 RS485 optional board programming key 1 (12 Vdc) 2 3 (24 Vdc) powersplit board 14 13 10 12 11 10 10 9 8 10 7 6 2 Hp 5 4 3 2 1 L N power supply 230 Vac UX UX UX 1 light alarm fan UX 2 defrost compressor

powersplit I/O boards Terminal PST00VR100 PST00LR200 PST00SR300 PSB0000000 PSB0001000 PSB0000100 PSB0001100 PTS00LR200 Vac power supply 230 230 230 230 compressor 2 Hp 2 Hp 2 Hp 2 Hp OUTPUTS INPUTS PLUS defrost ventilated evaporator PST00VR100, PST00SR300, PJC 2 Hp alarm light PJS,Y 2 Hp 33 18 33 33 22 5 6 5 155 aux ambient temperature defrost temperature product temperature ON/OFF input HCCP easy link dima di foratura drilling template 71 x 29 mm quick mounting dima di foratura drilling template 138.5 x 29 mm B C C sez. C-C B B 10 33 56 5 6 5 115 back-lit keypad removable terminals buzzer real time clock LN connection 35 RS485 optional Cod. +302240361 rel. 2.0 01.03.04 CREL S.p.. via dell Industria, 11-35020 Brugine (PD) Italy - Tel. (+39) 0499 716611 - Fax (+39) 0499 716600 - e-mail: carel@carel.com 2004 CREL S.p.. all rights reserved www.carel.com