Quick Guide. 2-way telescope tripod. with optional 3D safety adapter

Similar documents
24KO VARIO INSTRUCTION FOR MOBILE PROJECTION SCREENS VARIO 32 AND VARIO 64

PREFACE. Thank you for choosing Zen Space Desks. We hope your desk helps you find your zen when being used. Zen Space Desks Team

GH-30. Gimbal Head. You re on steady ground

TAKAMA FLIP-ZIP INTRODUCTION. KEY FEATURES (Illustration - 1) MULTI-FUNCTIONAL TRIPOD MONOPOD KIT. Thanks for choosing Takama!

RS-600AF-V2 RS-850AF-V2. Camera. Track Slider. with Adjustable Feet

MPS-850 e-drum set. assembly instructions

Product Overview. Features

icore Kiosk system Installation Guide

MBX INSTRUCTION MANUAL. Please read this manual carefully before using the MBX! Mid-range studio stand

Mk II 3DR MULTI-LINE LASER INSTRUCTION MANUAL

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays

KM-4800w. Installation Guide

Tripods, levelling ling staffs and fasteners

Aluminum Telescopic Masts and Accessories

3500 Series Tripod Kit

DSLR Filmmaking Kit 6-CF

Installation- and Operating instructions for CU Ethernet Controller with USB Input. Version: 1.4 Date:

C-pan arm USERS INSTRUCTIONS

AVT Model Tripod.

LIGHTWEIGHT TRIPOD 190D, 190CL, 190PRO, 190NAT3, 190MF3, 190MF4 SUGGESTED HEADS. Ball Head. Two way Head. Three Way Head. Geared Head 390RC2 460MG

EVOLVE1-M MONITOR ARM

3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series

BK MIKRO. Air Barrier Adapter. Assembly Instructions Issue 1.00 dated

PRODUCT MARKING AND BARCODE IDENTIFICATION. up to Serial No Barcode/Label printer MACH4. Service Manual. Edition 11/06

skyline 70 Fluid Head OPERATOR S MANUAL #1050 Skyline 70 Fluid Head

Power Series Camera Support

TEL: / FAX:

Documentation KM2042. Sixteen channel digital output module with D-Sub Connector. Version: Date:

3M Indoor Protected Building Entrance Terminal 4588V-QCS Series

i-series Videoconference Fixture

SKIVING MACHINE MAINTENANCE & INSTRUCTIONS MANUAL ASSK2. Allswage UK. Roebuck Street, West Bromwich, B70 6RB

Assembly Instructions for #5630 Medication PalWOW

INCLUDED HARDWARE REQUIRED TOOLS GETTING STARTED DISCLAIMERS! 5/32 Allen Wrench (Provided)

MD-BD13B / DUAL SEGMENT TWIN-ARM. For (33-69 cm) LCD desktop computer monitors. User Manual

Operation manual. IC-Scanner FLS 102. Copyright April 2008 LANGER EMV-Technik GmbH IC-Scanner FLS 102/0214

Operating Instructions Drill rigs DRU400 DRA400

RS-600AF RS-850AF RS-1200AF. Camera. Track Slider. With Adjustable Feet

ATV Single Gang Disc Harrow OWNER S MANUAL

Indoor Protected Entrance Terminal 4588 Series

Tactical Weather Station Set-Up Guide 1

安全說明書 TM Robot Stand Manual

User Guide VANTAGE. Lens Drive. Lens Drive. Part No. V

SPECIFICATION & INSTALLATION GUIDE

ITB THROTTLE WITH INTEGRATED STEPPER MOTOR INSTALLATION INSTRUCTION

Remote Control Electrical Roller Blinds

User Manual CARFIT Modular System Series CMK

PV Series. Owner s Manual. Photo Tripod

ALS Model Light Stand

SR-L09 SR-L05 OPERATING INSTRUCTIONS TABLE OF CONTENTS 1. SAFETY PRECAUTIONS GENERAL DESCRIPTION FEATURES CONNECTIONS...

Installation Guide Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

Sliding shutter control Aluminium shutters

Shoulder Support System

Manhole Configurator EK 800

5001 Letter Opener Operators Instructions

Documentation EM2042. Sixteen Channel Digital Output Module with D-Sub Connector. Version: Date:

DS5/DS10/DS20 Fluid Head Operator s Manual. #180 DS5 Fluid Head #182 DS10 Fluid Head #184 DS20 Fluid Head

Nov. 07, 2013 p. 5 - changed the B axis unit value to from Changed by Randy per Frank s request.

Operating Instructions USM Haller Tables

MD-BSL15W / SPRING-LOADED TWIN-ARM. For ( cm) LCD desktop computer. User Manual

Quick Installation Guide

Achat 206 passive full-range speaker. user manual

Nikon Focus Drive Manual

Articulating TV/Monitor Clamp/Grommet Desk Mount Model: DE640S (Hydro Series)

A-MOD DESKTOP OWNER S MANUAL

CTT Section Carbon-Fiber Tabletop Tripod. You re on steady ground 1

Operating Instructions

DUAL-ARM MONITOR MOUNT For in. ( cm) desktop computer monitors

Spotting Scope Instruction Manual

3001 SYSTEM AIR 3005 SYSTEM AIR C/F Fluid Head + Tripod. Operators Manual

Providing the accessories you need from quality brands you can rely on.

Documentation ZB8610. Fan cartridge for EtherCAT and Bus Terminals. Version: Date:

Table of Contents INTRODUCTION STREAMLINE CONSOLE. Overview..1. Overview..2. Features...2. Packing List..3. Assembly.. 4 ~ 6.

3M Indoor Protected Building Entrance Terminal (IBET) 4688V Series

PNOZ m ES RS232. Configurable Control System PNOZmulti. Operating Manual EN-01

Dual TV/Monitor Desk Mount Stand (Duplex Series) Model: DE9E2S-S

Universal Tablet Holder

Serial PROFIBUS Interface

INSTALLATION MANUAL DATAVAULT DATAVAULT - BARE JOBSITE STORAGE SOLUTIONS

POWER DSLR Camera Cage Shoulder Rig Kit

BEAVER TECHNOLOGY SERVICES

GH-50. Gimbal Head. You re on steady ground

Assembly Manual for Mobile X-ray

Flow Sensor SONOFLOW CO.55

Snap-in (front mounting) Locking type. Terminals Solder terminals *1 Color Light gray Black A7BL-207 *2 A7BL *2

WALSER GmbH & Co. KG Gewerbering Burgheim Tel: Fax: Germany

OWNER S MANUAL AMERICA S PREMIER EXERCISE EQUIPMENT RLM-855WS. Lat Machine W/200 Lbs Steel Weight Stack 83 1/2" 64 3/4" 45 1/4"

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

IC Scanner ICS 105. User manual. Copyright November 2013 LANGER EMV-Technik GmbH IC Scanner ICS 105/1216

Dell OptiPlex All-in-One. Stand Installation Guide

Orb Highchair Orb+ Highchair User Guide

JIB EPT USER MANUAL. Please read this manual carefully before using the Alphatron JIB ETP unit! JIB & MOTORISED PAN AND TILT UNIT

Assembly and Usage Instructions. Product # Instruction # Revision A

TEMPERIX S Clamp. FAFNIR GmbH Schnackenburgallee 149 c Hamburg Germany

HST -TZ1 Guard-locking mechanism (Translation of Original Manual)

NBS-2X NIMBUS STABILIZER QUICK-START GUIDE

Operating Manual. AdirPro HV8RL Red Beam Horizontal/Vertical Laser level

EL1142 Series. IEC / IEEE 1613 Hardened 2-Port 10/100BASE-TX to 2-Port 100BASE-FX Media Converter. User s Guide

Assembling the Christie QwikRig rigging frame

CU USB-Extender-Rx (USB and DVI Extender) Version: 0.3 Date:

HD NO HOLES MOUNT RAM SSV

Transcription:

Quick Guide 2-way telescope tripod with optional 3D safety adapter

Table of contents 2-way telescope tripod with safety adapter 1 Product description and safety 2 2 Scope of delivery 3 3 Setting up and initial use 4 3.1 Setting up the tripod 4 3.2 Operating the tripod upwards 5 3.3 ounting other toothed column elements for upward operation 7 3.4 Operating the tripod downwards 8 3.5 ounting other toothed column elements for downward operation 9 3.6 ounting the optional 3D safety 9 4 Technical data 10 5 Disclaimer 10 6 Contact 11-1 -

1 Product description and safety A tripod has never been so versatile: crank your scanners up high, but also low down. The 2-way telescope tripod enables scanning at heights of up to 4.00 meters and safe upside-down scanning 4.50 meters below the earth's surface. Depending on your measuring task, the rod with the mounting plates and 5/8" connection can be inserted in the tripod upright or upside-down. The additional extension rods are each securely connected to the previous rod element. This creates a crank rod that can be extended virtually any way you like. The 3/8" adapter included in the scope of supply enables use of the tripod with the FARO Focus 3D and the Trimble TX5 laser scanners. The 3D safety adapter is used for overhead applications. This enables you to scan overhead easily and safely. The special adapter enables easy assembly and a secure hold. The best protection for your valuable measurement technology developed and manufactured in Germany. Use in line with intended purpose Deployment with compatible scanner across a number of height ranges without assembly and dismantling Scanning at heights and safe overhead scanning by means of the adapter Compatible laser FARO Focus 3D S 120, FARO Focus 3D X series and HDR series Z+F IAGER 5006 series (5006i, 5006h) Leica HDS 7000 Leica HDS 6200 Leica HDS 6100 Leica HDS 6000 Trimble TX5 Z+F IAGER 5010 series (5010C, 5010X) Leica ScanStation P40 Leica ScanStation P30 Leica ScanStation P20 Safety To prevent personal injury or damage to property, comply with the safety information provided in this guide. The manufacturer shall assume no liability for damage or impairments resulting from non-compliance. Explanation of symbols You will find safety instructions and symbols at corresponding points in the text. DANGER Indicates imminent danger that can lead to fatal or life-threatening injuries. WARNING Indicates a possible danger that can lead to fatal or life-threatening injuries. NOTE Indicates a tip which, if ignored, can cause damage to property. - 2 -

2 Scope of delivery A 1 A A 2 B 1 B K L C 1 1 D E 1 2 3 F N C 2 G H I 1 I O A B C J ounting plate with 5/8" connection for the scanner, with 3/8" additional adapter (A 1) and locking bolt (A Toothed column adapter for upward connection with retaining screw (B 1) Clamping bolts (C 1 and C 2) to lock the toothed column I J K - 3 - Toothed column adapter for downward connection with retaining screw (I 1) Safety adapter (2 parts) with bolts Spirit level D 1. T-bar socket wrench 2. Bit 3. Bit holder L Crank E Side clamps Toothed column element and 4 additional toothed column elements (all with retaining screw ( 1)) F Tripod legs N Bag for toothed column elements and accessories G Centre braces O Velcro lashing strap H Locking screws of the center braces P Rubber caps P

3 3.1 Setting up and initial use Setting up the tripod 1 2 F E O Undo the Velcro lashing strap (O) on the three tripod legs (F). Undo the side clamps (E). 3 4 E F H H P 3.1 Extend the tripod legs (F) to the desired length. 3.2 Undo the locking screws (H) of the center 4.2 braces. 4.3 NOTE If the position of the tripod is not perpendicular, vibrations occur during rotation of the laser scanner, impairing the quality of the scan. Use the spirit level (K) to set up the tripod vertically. 4.1 Pull the tripod legs (F) apart to the desired width. Place the tripod securely on the ground. Retighten all of the side clamps (E) and locking screws (H). WARNING If the ground is soft, icy or slippery, there is a risk that the tripod legs will slip. Use the rubber caps (P). - 4 -

3.2 Operating the tripod upwards 1 2 B B 1 For upward operation, place the toothed column adapter (B) on the upper end of the toothed column element (). Use the T-bar socket wrench (D 1) to tighten the retaining screw (B 1). 3 4 A A 2 For upwards operation, attach the mounting plate for the laser scanner (A) on the toothed column adapter (B) you have just mounted. Fix the mounting plate for the laser scanner (A) in place by turning the locking bolt (A 2). 5 Place the laser scanner with 5/8" connection on the mounting plate. - 5 -

TIPP: A 1 To mount a laser scanner with a 3/8" connection on the tripod, screw the 3/8" adapter (A 1) onto the mounting plate (A) beforehand. 6 C 1 C 2 Undo both clamping bolts (top C 1 and in the center C 2) to lock the toothed column elements. 7 WARNING The entire crank unit is configured for continuous operation with up to 20 kg. An additional load can damage the tripod. ake sure that the total weight of the toothed column elements and laser scanner does not exceed 20 kg. TIPP: You can order other toothed column elements at any time on request. L Use the crank (L) to raise the toothed column element to the desired height. - 6 -

8 C 1 C 2 Retighten the clamping bolts (top C 1 and in the center C 2) to lock the toothed column element in place. You can now carry out your scans. WARNING Cranking without undoing the clamping bolts beforehand can lead to severe wear in the helical-worm gear unit and damage the crank. Before cranking, always undo clamping bolts C 1 and C 2. NOTE Accelerate the extension of the toothed column elements () using a cordless drill/screwdriver. Use the bit holder supplied with the accessories (D 2 and D 3). 3.3 ounting other toothed column elements for upward operation D 2 D 3 1 2 1 Insert another toothed column element () on the double pin of the toothed column element located in the tripod. Use the T-bar socket wrench (D 1) to tighten the retaining screw ( 1). NOTE If the tripod is set up at too low a height, no toothed column elements can be fitted to create an extension. Extend the tripod to a height of at least 1.10 meters. NOTE A laser scanner can be operated on the tripod up to a height of 6.00 meters. Operation at greater heights can lead vibrations (due to wind when outdoors) and diminish the quality of your scans. It is recommended to scan at a maximum height of 4.00 meters. - 7 -

3.4 Operating the tripod downwards 1 2 I 1 I Place the adapter for downward operation (I) on the bottom end of the toothed column element (). Tighten the retaining screw (I 1) of the adapter. 3 4 C 1 L Undo the clamping bolts (top C 1 and in the center C 2) to lock the toothed column elements in place. See chapter 3.2, step 6. Use the crank (L) to lower the toothed column element to the desired depth. 5 WARNING C 1 If the toothed column element is cranked down too far, the rod and laser scanner can fall. Never crank down so far that the end of the toothed column element at the top can no longer be seen. Retighten the clamping bolt (C 1) to lock the toothed column element in place. You can now mount the laser scanner and carry out your scans. - 8 - NOTE Accelerate the extension of the toothed column elements () using a cordless drill/screwdriver. Use the bit holder supplied with the accessories (D 2 and D 3). D 2 D 3

3.5 ounting other toothed column elements for downward operation 1 2 1 If the toothed column adapter (B) for the upward connection is still attached to the tripod, remove it. Insert another toothed column element () on the double pin of the toothed column element located in the tripod. Take a firm hold of the toothed column element to be inserted () and use the T-bar socket wrench (D 1) to tighten the retaining screw. 3.6 Optional: mounting the 3D safety 1 2 Laser Bolt the cover plate of the 3D safety adapter onto the original baseplate of the laser scanner. 2.1 Attach the counterpart piece of the 3D safety adapter on the mounted toothed column adapter (I) at the tripod. 2.2 2.3 Push the cover plate with the laser scanner into the guide rail of the 3D safety adapter. Secure the connection by pulling out the black safety split pin and letting it snap back. You can now carry out your scans safely. - 9 -

4 Technical data 2-way telescope tripod 5/8" connection; adapter for laser scanners with 3/8" connection (included in scope of delivery) Transport length Weight inimum usable height aximum usable height aterial ounting plate for scanner with locking bolt approx. 1.30 m approx. 8.5 kg approx. -4.50 m below the earth's surface approx. 6.00 m (up to 4.00 m is recommended) Aluminum Diameter 11.0 cm Toothed column elements 1.00 m each Crank drive with crank or cordless drill/screwdriver 3D safety adapter Weight Dimensions 200 g 10.0 cm x 10.5 cm x 10.0 cm Compatible laser scanners All laser scanners with 5/8" and 3/8" connection; a maximum of 20 kg is permitted with continuous operation 5 Disclaimer Laserscanning Europe GmbH assumes no liability and grants no warranty, neither expressly nor by implication, with regard to the information contained in this operating manual. Buyers of the product bear the costs of all required services or repairs and damage caused as a result of improper use of this product or non-compliance with the safety instructions as well as direct or indirect damage and loss (including loss of profit and information loss) resulting from product deficiencies. Unauthorized copying or dissemination of the content of this document, whether in part or as a whole, is prohibited. The right to make changes to the product and instructions is reserved. Everything possible has been done to ensure that the content of this document is correct. Should you discover any errors or if details appear to be unusual, please notify Laserscanning Europe GmbH. - 10 -

6 Contact Laserscanning Europe GmbH Gustav-Ricker-Str. 62 39120 agdeburg Telephone: +49 (0)391-62 69 96 0 Telefax: +49 (0)391-250 9051 ail: info@laserscanning-europe.com Web: www.laserscanning-europe.com Laserscanning Europe GmbH Büro Süddeutschland Talstraße 8 73249 Wernau Telephone: +49 (0)7153-92 95 93-11 -