Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range

Similar documents
Proximity Card and Pin Reader Installation Manual

Wireless Expansion Module V2.0 OMN-RCV3. Reference & Installation Manual. Stand-Alone System

CA-A480-A Elevator Controller. Reference & Installation Manual

DOLXFD1000B. Waterproof Access Control/Reader

212iL Rev. 1.1

232iLM Keypad Installation and Programming Instructions

232iLM Keypad Installation & Programming Instructions

Agility 2-Way Wireless Slim Keypad

DG-800 Stand-Alone Proximity Reader Instruction Manual

Carefree-Security. Installation and programming instructions 1050A. Owner s Manual

2-Way Wireless I/O Expander Installation Guide

LCD62. Keypad. User Manual

FlexPass TM Advantage Series Proximity Plus TM ASR PowerProx TM Reader User Manual

EL-ST100 KEYPAD CONTROLLER

FlexPass. ASR Long Range Reader. Installation Guide Jeronimo Road Irvine, CA July 16, 2007 Document Number K , Rev B

ENFORCER SK-1131-SQ. Digital Access Keypad with 5A Relay Output MANUAL. Digital Access Keypad Manual. Also available from SECO-LARM: Outdoor Keypads

Secured Series: Hub Plus Kit Single Door Controller Package Installation Manual

User Manual. PCKeypad Wireless Keypad

Digital Keypad Introduction

CP150B Vandal & Weather Resistant Keypad Security Systems

MS-5000: MiniStar Reader

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

AK-21. Digital Keyless Entry System. Installation and Programming Instructions

MS-7000: SuperStar Reader

e-ask electronic Access Security Keyless-entry OEM / Dealer / Installer Cargo Lock / Unlock Version Installation & Instructions (UM04 ~ )

_A_en_LED63VG VOICE GUIDE KEYPAD LED63VG

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

AY-Bx660 Family Full Fingerprint Match-on-Card Readers Installation Manual. Models: AY-B1660 AY-B2660

SMD Series Integrated Stepper Driver and Motor Revision 1.3

Stand-alone Proximity Access Control

I/O Expansion Box Installation & Operator s Instruction Manual

Installation Manual Rev D MiniProx Readers - Wiegand 5365B and Clock and Data 5368B

RBR-SB-KTZ001 LAR 2. User Manual

Installing Keypad and Backplate

MS-3000 MicroStar Reader

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

Outdoor Stand-Alone Weatherproof Keypads

INTELLIGENT DOCKING STATION USERS MANUAL

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

SK-1011-SQ Digital Access Keypad with 5A Relay Output

Waterproof. Keypad/Reader/Controller

AC-115 Compact Networked Single-Door Controller Hardware Installation and Programming

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Enter a new user. code. Enter. Enter a 2-digit user ID. Enter a user code. (from 00~09) (from 00~09) Enter

Operating Instructions KEYPAD. Compatible WIRELESS ACCESS CONTROL

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

Gefen. Extender for HDMI 3DTV GTB-HDMI-3DTV GTB-HDMI-3DTV-BLK. User Manual

GV-Card Reader. User s Manual

EN FULL DETAILS SKB. Vandal Resistant keypad - Full Details

Long range Multi Reader AY-Z12A Installation Guide

AC-015 Single-Door Access Control Programmer Hardware Installation and Programming Manual

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Single Door Standalone Access Control User Manual

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

CM-110SK Standalone Keypad Installation Instructions

ME15 Magnetic Encoder Manual Revision 1.1

Adjustable Timing Control PN 8680

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

W3-H Waterproof Keypad/Reader/Controller

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

AC-Q4x Family. Instruction Manual. Vandal Resistant Stand-Alone controllers. Models: AC-Q41H/HB AC-Q41SB AC-Q42H/HB AC-Q42SB AC-Q44

MWC-8. Operation MWC-8 800MHz Controller Manual. Operation Manual. manmwc9.

e-ask electronic Access Security Keyless-entry RF Keyless-entry entry System TM-Multi Multi Installation Manual FCC ID: TV2EFOB1 (UM21 ~ )

LLTOUCHDX4 - PRODUCT INFORMATION

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

-DTZ001- Stand-Alone Proximity Access Control. User Manual

2000 Series e/em Style Keypad Installation and Programming Manual

Bluetooth Enabled Access Control MODEL BG-FE. Operating Instructions

Electronic Code Lock. SL2000E v1.1

Adjustable Timing Control PN 8680

Proliphix EPA-60 Installation Guide

PixController, Inc. Wireless Switch Sensor For Normally Open (NO) and Normally Closed (NC) Sensors

ilink Installation & User Manual Internet Downloadable MP3 Music & Message Series

Integrated Stepper Drive & Motor

Installation and User Manual

ROSSLARE AC-115. Hardware Installation and User s Guide DOOR MODE 10/01

HDKVM ELR extension for HDMI and USB Over One CAT5

Kodiak Mobile INTELLIGENT DOCKING STATION USERS MANUAL PART NUMBER: PANASONIC CF53 TOUGHBOOK COMPATIBLE AN ISO 9001:2008 CERTIFIED COMPANY

MR52 READER INTERFACE

ACLD Channel Opto-isolated Digital Input Board

EXT-DVI-CAT5-4X User Manual

The IQ300 wall mount load cell indicator is a precision digital indicator for load cell and strain gauge applications.

Tracer VM Bluetooth Interface

Keypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual

SKE Series. 12-Pad. Installation & Instruction Manual. Essex Electronics, Inc KEY-LESS fax keyless.

INSTALLATION INSTRUCTIONS

DC425 NEMA 4X Analog Output Transducers

1.3 Operating Conditions -40 F to 150 F (-40 C to 65 C) 0% to 90% Relative Humidity, non-condensing

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

Meso LED Driver stands for an extremely flexible LED Driver, designed for fast and easy configuration.

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

DVI Extra Long Range Extender

Type 2: Hyundai Genesis Coupe... Type 3: 2011 Hyundai Sonata... Programming Module Programming... Resetting the Module...

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

VIDI-AC-2CS Access Controller/ Reader

Digital Electronic Lock OWNER S MANUAL

AS Keypad User Manual

Transcription:

Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1

TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting on Metal Surfaces... 3 Technical Specifications... 3 Feedback... 7 Resetting to Default... 7 Card Presentation Test... 8 System Programming... 9 Section [001] Card/Code Options... 10 Section [002] Door Lock Control... 10 Section [003] Access Granted Options... 11 Single Access Granted... 11 Dual Access Granted... 11 Dual Access Granted with Dual Panic Disarm... 12 Section [004] Display on Card Read... 12 Section [005] Keypad Lockout... 13 Section [101] Buzzer Setting... 13 Section [102] Face Light Intensity... 13 Section [103] Face Light Operation... 14 Section [104] Face Light Colour... 14 Section [200] Changing the Installer Code... 14 Resetting the Installer and Master Codes to Default... 15 Master Programming...16 Sections [201] and [202] Changing the Master Codes... 16 Section [203] User Code Programming... 17 Deleting a User Code... 19 Section [204] User Code Reset... 20 User Operation...21 User Access... 21 Panic Alarm... 22 User Code Table...24 Warranty...26 CR-R885-SB 1

INSTALLATION To select an installation site: Avoid wiring the CR-R885-SB s cables in the same conduit as AC power cables, lock power or signal wiring. Reader wiring must remain a minimum of 30cm (12in) away from other wiring, such as wiring for AC power, computer data, telephones, electric locks, etc. Avoid sites within 1.1m (3.5ft) of computer monitors or CRTs. Avoid sites near sources of broad spectrum EMI noise, such as motors, pumps, generators, DC to AC converters, AC switching relays, power supplies and light dimmers. Avoid sites near potential sources of RF signals, such as cellular phones, two-way radios, etc. MOUNTING AND WIRING Use the mounting plate as a guide to drill two holes to secure the mounting plate and a hole for the cable 0.95cm to 2.54cm (0.375in to 1in) wide. Place a grommet around the edge of the hole for the cable. Prepare the CR-R885-SB s cable by cutting the cable jacket back 3.175cm (1.25in) and stripping the wires back 0.635cm (0.25in). Splice the CR-R885-SB s wires with a recommended cable wire (see page 7) and connect as shown in Figure 1 on page 5. 2 Installation and Operating Instructions

MOUNTING ON METAL SURFACES Although the read range may decrease, the CR- R885-SB can be mounted on metal. However, do not box in or surround the card reader with any kind of metal. If the reader must be installed in a metal enclosure, ensure that the face of the card reader is not covered and that at least 1.6" (4cm) remain between the card reader and the metal on all sides of the card reader. TECHNICAL SPECIFICATIONS Input Voltage: Typical: 13.8Vdc, min.: 11.0Vdc, max: 14.5Vdc Input Current: Typical: 65mA @ 12.5Vdc, with card: 105mA Consumption: Typical: 812mW @ 12.5Vdc, with card 1.31mW Frequency: Exciter Field: 125kHz Pulse Modulated, receive low: 12.5kHz, Receive high: 15.625KHz Operating Temp: -25 C (-13 F) to +65 C (+149 F) Cable Distance: 152.4m (500ft) Suggested Cables: 22AWG, 0.8mm, Multiconductor, Alpha 5196, 5198 18AWG, 1.2mm, Multiconductor, Alpha 5386, 5388 Belden 9553, 18AWG, 6- conductor, stranded w/overall shield Indicators: Beeper, red LED and green LED CR-R885-SB 3

Weight: Material: Dimensions: Wire Function: For CR-R885-S: red and green Face Light For CR-R885-SB: blue and green Face Light 280g (9.8 oz.) Black, UV resistant, ABS plastic 99.5mm (5.75") x 118.5mm (2") x 19.5mm (1") Brown: Not used Black: Ground Green: Panic Out White: COM Yellow: Normally Closed (N.C.) Orange: Normally Open (N.O.) Red: +12Vdc 4 Installation and Operating Instructions

Figure 1: Connection drawing (12V Locks) CR-R885-SB 5

Figure 2: Connection Drawing (24V Locks) 6 Installation and Operating Instructions

FEEDBACK Depending on the programming mode chosen, the feedback will differ. In the section System Programming on page 9 and Master Programming on page 16, the combinations of visual feedback and beep tones are specified step by step. Visual Feedback: When information is entered on the reader s keypad, the red and/or green LEDs will flash, remain constant or extinguish depending on the step reached in programming. Confirmation Beep: When an operation is successfully entered, the reader emits a rapid series of beep tones ( beep-beep-beep-beepbeep ). Rejection Beep: When the system reverts to a previous status or an operation is incorrectly entered, the reader emits one long beep tone ( beeeeeeeeeep ). RESETTING TO DEFAULT To reset all sections to factory defaults, disconnect reader s power supply. Press and hold the [1] and [2] keys simultaneously while reconnecting its power supply. The reader will emit a confirmation beep. Repeat this procedure a second time holding the [3] and [4] keys. Sections are reset when the reader emits the second confirmation beep. CR-R885-SB 7

CARD PRESENTATION TEST Place the card parallel to the CR-R885-SB reader (as shown in the figure) and move it toward the reader until the reader provides audio or visual feedback. 8 Installation and Operating Instructions

SYSTEM PROGRAMMING The Installer Code (default: 000000) can program a new Installer Code PIN in section [200] and program all the system sections from [001] to [005] and [101] to [104]. To Enter System Programming Mode: 1. Press and hold the [CLEAR] key for 4 seconds. The reader emits a confirmation beep, the green LED illuminates and the red LED extinguishes. 2. Enter the [INSTALLER CODE] and press the [ENTER] key. Reader emits a confirmation beep and the green LED flashes. 3. Enter the 3-digit [SECTION] and press the [ENTER] key. Reader emits a confirmation beep and green LED becomes constant. 4. Enter the required [DATA] and press the [ENTER] key. The reader emits a confirmation beep and the green LED flashes. 5. To program another section, repeat steps 3 and 4. To exit, press and hold the [CLEAR] key for 4 seconds. The reader emits a rejection beep and the green LED extinguishes. CR-R885-SB 9

SECTION [001] CARD/CODE OPTIONS The CR-R885-SB can function as a reader only, as a keypad only or as a combined reader and keypad. Option [3] by default Enter Description [0] Keypad and reader disabled. For programming only. [1] Reader only. Present valid card to the reader for Access Granted. [2] Keypad only. Enter valid code on the keypad for Access Granted. [3] Keypad and reader enabled. A user must present BOTH a valid card AND enter a valid code to receive an Access Granted. When a Card/Code option is set, it may require several seconds for the system to update the programming. The reader emits a confirmation beep once the modification is complete. SECTION [002] DOOR LOCK CONTROL The Door Lock Control determines the length of time the locking device remains unlatched after an Access Granted. When [0] is programmed, the lock is unlatched after an Access Granted and remains unlatched until it receives a second Access Granted (functions like a key). When [1] to [5] is programmed, the lock remains unlatched for the defined time period. Option [2] by default. 10 Installation and Operating Instructions

Enter Description [0] Card/Code Controlled Free Access (Latched). [1] 1 second. [2] 5 seconds. [3] 10 seconds. [4] 20 seconds. [5] 60 seconds. SECTION [003] ACCESS GRANTED OPTIONS The Access Granted Options depend on the Card/ Code Options set in section [001]. Option [0] by default. Enter Description [0] Single Access Granted. [1] Dual Access Granted. [2] Dual Access Granted with Dual Panic Disarm. Single Access Granted When [0] is programmed, one user can obtain Access Granted by using a valid card, code or both depending on the Card/Code Option set. Dual Access Granted When [1] is programmed, two users are required to obtain Access Granted. Each user must use a valid card, code or both depending on the Card/ Code Option set. Only one user is required to disarm a Panic Alarm. CR-R885-SB 11

Example: When the reader and the keypad are enabled, User 1 must present a valid card and enter a valid code and then User 2 must present a valid card and enter a valid code for Access Granted. Dual Access Granted with Dual Panic Disarm When [2] is programmed, two users are required to obtain Access Granted (same as Dual Access Granted) and two users are required to disarm a Panic Alarm. For example, a Panic Alarm is triggered, User 1 must present a valid card and enter a valid code and then User 2 must present a valid card and enter a valid code to disarm the alarm. SECTION [004] DISPLAY ON CARD READ The visual feedback when a card is presented to the reader can be adjusted according to the installation s requirements. Option [3] by default. Enter Description [0] Display on Card Read disabled. [1] Red Status LED flashes. [2] Green Status LED flashes. [3] Red and green Status LEDs flash. [4] Face Light flashes. [5] Face Light and red Status LED flash. [6] Face Light and green Status LED flash. [7] Face Light and both Status LEDs flash. 12 Installation and Operating Instructions

Select [0] in Section [103] Face Light Operation on page 14 to enable options [0] to [3] in section [004] or select [1] in Section [103] Face Light Operation on page 14 to enable options [4] to [7] in section [004]. SECTION [005] KEYPAD LOCKOUT When Keypad Lockout is enabled and the Installer Code is entered incorrectly 3 consecutive times, the keypad ignores all entries for 60 seconds. Option [0] by default. Enter Description [0] Keypad Lockout disabled. [1] Keypad Lockout enabled. SECTION [101] BUZZER SETTING The number of beep tones emitted as a response to a card being presented to the reader can be adjusted from 0 (disabled) to 7 (7 rapid beep tones). Option [3] by default. SECTION [102] FACE LIGHT INTENSITY The Face Light s illumination can be adjusted according to the installation s requirements from 0 (extinguished) to 8 (brightest). Option [4] by default. CR-R885-SB 13

SECTION [103] FACE LIGHT OPERATION The Face Light can be set to remain illuminated continually or can follow the state of the Status LEDs. Option [1] by default. Enter Description [0] Face Light constant. [1] Face Light follows Status LEDs. If [0] in section [103] is selected, this will override options [4] to [7] in Section [004] Display on Card Read on page 12. In addition, if [1] in section [103] is selected, this will override [0] to [3] in Section [004] Display on Card Read on page 12. SECTION [104] FACE LIGHT COLOUR The Face Light s colour can be modified as desired. Option [0] by default. This feature only applies when Face Light Operation programmed in Section [103] is set for Option [0]: Face Light constant. Enter Description [0] Blue Face Light. [1] Green Face Light. SECTION [200] CHANGING THE INSTALLER CODE The Installer Code (000000 by default) is used to program all the system s sections, but cannot program the Master and User Codes (see 14 Installation and Operating Instructions

page 16). In section [200] enter six digits where each digit can be any value from 0 to 9. RESETTING THE INSTALLER AND MASTER CODES TO DEFAULT To reset the Installer Code, Master Code 1 and Master Code 2 to factory defaults, disconnect the reader s power supply. Press and hold the [3] and [4] keys simultaneously while re-connecting its power supply. Installer Code, Master Code 1 and Master Code 2 are reset when the reader emits a confirmation beep. CR-R885-SB 15

MASTER PROGRAMMING Master Programming Mode is used to program Master and User Codes. SECTIONS [201] AND [202] CHANGING THE MASTER CODES Master Code 1 (default: 111111) is used to program both Master Codes, the User Codes and the Section [002] Door Lock Control (see page 10). Master Code 2 (default: 222222) can program the User Codes and change its own PIN. Master Code 2 cannot program Master Code 1 or the Door Lock Control. In the desired section enter the 6-digit personal identification number (PIN) where each digit can be any value from 0 to 9. To Change the Master Codes: 1. Press and hold the [CLEAR] key for 4 seconds. The reader emits a confirmation beep, the green LED illuminates and the red LED extinguishes. 2. Enter [MASTER CODE 1 or MASTER CODE 2] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash simultaneously. 3. Enter [201] to change Master Code 1 or [202] to change Master Code 2 and press the [ENTER] key. Reader emits a confirmation beep and the green LED becomes constant. 4. Enter the new PIN and press the [ENTER] key. 16 Installation and Operating Instructions

The reader emits a confirmation beep and both LEDs flash. 5. To exit, press and hold the [CLEAR] key for 4 seconds. The reader emits a rejection beep and the green LED extinguishes. SECTION [203] USER CODE PROGRAMMING Master Code 1 and 2 can activate cards and program the personal identification numbers (PIN) for the User Codes. The CR-R885-SB includes 1000 User Codes. User Code 000 to 999 can be 1 to 8 digits in length where each digit can be any value from 0 to 9. You can use the table on page 24 to record the User Codes. To Program User Codes: 1. Press and hold the [CLEAR] key for 4 seconds. The reader emits a confirmation beep, the green LED illuminates and the red LED extinguishes. 2. Enter [MASTER CODE 1 or MASTER CODE 2] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash simultaneously. 3. Enter [203] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash alternately. 4. Enter the User Code number from 000 to 999. Press the [ENTER] key. The reader emits a confirmation beep and the green LED illuminates. If the red LED CR-R885-SB 17

illuminates, the section is empty. If the red LED stays extinguished, a User Code is already programmed in the section. 5. Program the card, access code (or both combined) according to the option selected in section [001] (see page 9). Then enable one of the following options: Reader only: present the card to the reader without pressing the [ENTER] key. The reader will automatically advance to the next User Code. Keypad only (PIN is less than 8 digits): enter PIN and press the [ENTER] key to advance to the next User Code. Keypad only (PIN is more than 8 digits): enter PIN, the reader will automatically advance to the next User Code after you have entered the 8th digit. Keypad and reader: present the card to the reader followed by the PIN. Press the [ENTER] key to advance to the next User Code. 6. Return to step 5 to program another card, otherwise to exit: Press [CLEAR] key. The red and green LEDs will flash alternately. Press the [CLEAR] key a second time. Both LEDs will flash simultaneously. Press and hold the [CLEAR] key a third time to exit this section. 18 Installation and Operating Instructions

When you press the [CLEAR] key in step 5: If the User Code is not programmed, the CR-R885-SB will revert to step 4. If a card or PIN was entered, press the [Enter] key to confirm the removal and advance to the next user code or press the [CLEAR] key to enter a new user code. If you press and hold the [CLEAR] key you will exit this section entirely. DELETING A USER CODE User Codes can be deleted individually. When the User Code is deleted, a new card and/or PIN can be programmed in the section. To Delete User Codes: 1. Press and hold the [CLEAR] key for 4 seconds. The reader emits a confirmation beep, the green LED illuminates and the red LED extinguishes. 2. Enter [MASTER CODE 1 or MASTER CODE 2] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash simultaneously. 3. Enter [203] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash alternately. 4. Enter the number of the desired User Code. Press the [ENTER] key. The reader emits a confirmation beep and the green LED illuminates. If the number is available, the red LED illuminates. If the red CR-R885-SB 19

LED remains extinguished, a User Code is already programmed using that number. 5. Press the [CLEAR] key. The red LED flashes. 6. Press the [ENTER] key to confirm the removal and advance to the next section. 7. Press and hold the [CLEAR] key to exit the section. 8. Press and hold the [CLEAR] key for 4 seconds to exit. SECTION [204] USER CODE RESET User Code Reset is used to delete all the User Codes (from User Code 000 to 999). To Reset all User Codes: 1. Press and hold the [CLEAR] key for 4 seconds. The reader emits a confirmation beep, the green LED illuminates and the red LED extinguishes. 2. Enter [MASTER CODE 1 or MASTER CODE 2] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash simultaneously. 3. Enter [204] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash alternately. 4. Press the [1] key and then press the [ENTER] key to confirm the reset. This may take a few seconds, then the reader emits a confirmation beep when the User Codes are deleted. 20 Installation and Operating Instructions

When the User Codes are reset, it may require several seconds for the system to update the programming. The reader emits a confirmation beep once the modification is complete. USER OPERATION USER ACCESS Access is granted according to the Card/Code Option (see page 10) and the Access Granted Option set (see page 11). Reader Only Keypad Only Single Access Granted 1 user: user presents a valid card to the reader. 1 user: user enters a valid User Code on the keypad and presses the [ENTER] key. Dual Access Granted 2 users: each user presents a valid card to the reader. 2 users: each user in turn enters a valid User Code on the keypad and presses the [ENTER] key. CR-R885-SB 21

Reader and Keypad Single Access Granted 1 user: user presents a valid card to the reader. The reader emits a confirmation beep and the green Status LED flashes. User must enter a valid User Code on the keypad and press the [ENTER] key within 10 seconds. Dual Access Granted 2 users: the first user presents a valid card to the reader. The reader emits a confirmation beep and the green Status LED flashes. The first user must enter a valid User Code on the keypad and press the [ENTER] key within 10 seconds. The reader will emit a Confirmation Beep and the red Status LED flashes slowly. The second user has 30 seconds to present a valid card to the reader and then enter a valid User Code. The second user s card and/or User Code must be different from the first. PANIC ALARM A panic alarm can be generated by pressing and holding the [CLEAR] and [ENTER] keys for 2 seconds. The Panic Alarm will activate the panic output (see Figure 1 on page 5). Access will not 22 Installation and Operating Instructions

be granted to users until the Panic alarm is disarmed. Disarming a Panic Alarm depends on the Card/Code Option (see page 10) and Access Granted Option (see page 11). To disarm a Panic Alarm: Reader Only Keypad Only Reader and Keypad Single Dual Access Access Granted Granted Present 1 valid card to the reader Dual Access Granted with Dual Panic Disarm 2 users: each user presents a valid card to the reader. Enter 1 valid User 2 users: each user Code and enters a valid User press the [ENTER] Code and presses key the [ENTER] key. Present 1 valid card to the reader then enter 1 valid User Code and press the [ENTER] key 2 users: the first user presents a valid card to the reader. then must enter a valid User Code and press the [ENTER] key. The second user has 30 seconds to present a valid card to the reader and then enter a valid User Code. The second user s card and/or User Code must be different from the first. CR-R885-SB 23

USER CODE TABLE Use this table to keep a record of the User Codes. If you require extra pages, photocopy this table. The PIN column is provided for your convenience, however, we recommend not using it for security reasons. User Code Name Card Number PIN (optional) 24 Installation and Operating Instructions

User Code Name Card Number PIN (optional) CR-R885-SB 25

WARRANTY Paradox Security Systems Ltd. ( Seller ) warrants its products to be free from defects in materials and workmanship under normal use for a period of one year. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system and shall not be responsible for circumstances resulting from the product s inability to operate. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. Returns must include proof of purchase and be within the warranty period. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect or consequential or incidental, including without limitation, any damages for lost profits stolen goods, or claims by any other party, caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold. Notwithstanding the preceding paragraph, the Seller s maximum liability will be strictly limited to the purchase price of the defective product. Your use of this product signifies your acceptance of this warranty. BEWARE: Dealers, installers and/or others selling the product are not authorized to modify this warranty or make additional warranties that are binding on the Seller. 2001-2008 Paradox Security Systems Ltd. All rights reserved. Specifications may change without prior notice. One or more of the following US patents may apply: 7046142, 6215399, 6111256, 6104319, 5920259, 5886632, 5721542, 5287111, 5119069, 5077549 and RE39406 and other pending patents may apply. Canadian and international patents may also apply. APPROVAL Compliant to all EU and EFTA countries except Greece according to RTT&E directives. 26 Installation and Operating Instructions

Notes CR-R885-SB 27

For technical support in Canada or the U.S., call 1-800-791-1919, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. For technical support outside Canada and the U.S., call 00-1-450-491-7444, Monday to Friday from 8:00 a.m. to 8:00 p.m. EST. Please feel free to visit our website at www.paradox.com. PARADOX.COM Printed in Canada 03/2008 CRR885SB-EI04