Blue ID Power injection module PI60

Similar documents
Blue ID Communication module RS485 SC44

Priva Blue ID Communication module RS485 SC44

Priva Blue ID Digital input module DI4/DI8/DI16

Priva Blue ID Relay output module DOR4/DOR8

Priva Blue ID Communication module RS232 SC22

Priva Blue ID Analogue output module with manual override AO2m/AO4m

Priva Blue ID Network module SN1/SN2/SN3/SN3t

DOR6. Components All functions and indications are on the front of the module. Characteristics

Priva Blue ID system overview

Priva Blue ID C-Line Mix input/output module MX34

Priva Blue ID C-Line system overview

Priva Blue ID C4 Controller with manual override C-MX34m

RТTH DUAL ROOM SWITCH

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

Model Number Structure

RXTH DUAL ROOM SENSOR / SWITCH

RXTP ROOM TEMPERATURE

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Power supply module, bus connection module

DeltaV Bulk Power Supplies

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

KUANTECH (SHEN ZHEN) COMPANY LIMITED KSAFD W1UK

Island bus expansion module

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

Resistance measuring module

20 General technical data XI/ON

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

DeltaV Bulk Power Supplies

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

TM5C12D6T6L compact I/O expansion block TM5-24 I/0-12 DI - 6 DO transistor - 4 AI - 2 AO


Installation Instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

PHOENIX CONTACT Features

1492-SP Supplementary Protectors

General Specifications

RCMB20/RCMB Series

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

ECLYPSE Communication Modules

AC-DC POWER SUPPLY UNIVERSAL INPUT, DESK TOP, WATTS MEDICAL APPLICATIONS MUI310-A Series

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

MINI-PS AC/10-15DC/8

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Model Number Structure

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

XUSL4E14F046N XUSL type 4 - Finger protection - Std sensing range - Hp = 460 mm, R=14mm

NEW Series SSH Output to 75A, 510 Vac with Diagnostics High Industrial Performance (HIPpak) Solid-State Relays

OTB1C0DM9LP I/O distributed module OTB - CANopen bus m

Switch Mode Power Supply S8VT 120/240/480/960 W Models

External level devices for conductive point level switch

Thread length (overall length) material

ECLYPSE Communication Modules

s Climatix AHU ext. module 14 I/O POL955.XX/XXX Climatix

System Specifications

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

Electronic timer CT-ERD.12

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Faults on the system Proximity switch connection technology:

System Specifications

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

AC-DC POWER SUPPLIES UNIVERSAL INPUT, 65 WATT MEDICAL APPLICATIONS MUI65 SERIES

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Operating instructions. Switching amplifier DN0210 DN / / 2015

RM35UB3. Product data sheet Characteristics. voltage control relay RM35-U - range V AC. Main. Complementary

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

CliQ II Buffer Module 24V 40A / DRB-24V040ABN

Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Ethernet. RJ45 Copper Ports

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

OTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m

XUSL4E14F121N XUSL type 4 - Finger protection - Std sensing range - Hp = 1210mm, R=14mm

TU531, TU532 Terminal Unit

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

RM17UB3. Product data sheet Characteristics. voltage control relay RM17-U - range V AC. Main. Complementary

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Original operating instructions Safety relay with relay outputs G1501S / / 2016

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

NX integrated safety System configuration. Integrated safety into machine automation

OTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

NI 6521 Specifications

TM3AI4 module TM3-4 analog inputs

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

02/11/2015

XUSL4E2BB051L XUSL type 4 - Body protection - Long sensing range 510 mm

Series AMEL10-MJZ 10 Watt AC-DC / DC-DC Converter

Transcription:

Blue ID Power injection module Legend A B LED for status of module LED for system power LED for status of module The LED shows the status of the module. The LED is on continuously when the module is working correctly. If not, and in special circumstances, the LED flashes. LED for system power An LED indicates the status of the system power. The LED is on if the power supply is working correctly. A Blue ID Power injection module is used to power a new, fused power supply segment. Characteristics voltage monitoring transferring communications signals 24 V system power supply monitoring wiring uses spring terminals New power supply segment The I/O modules in Blue ID are powered by the system power supply (24 VDC). This system power is connected via the controller and then distributed via the base of the I/O modules. If the I/O modules demand more power than can be supplied via the controller, a Blue ID Power injection module must be used. TC Engineer calculates this for you. Clear indication On the PI module the system power present (A) is interrupted and re-established (B). This creates a new power supply segment (C). To do this both A and B should be present therefore. The internal communication signals (D) are transferred as normal. This module may not be removed or installed while the power is connected. 1

Connections Legend A B C + - FE release mechanism for module cover, fuse can be accessed by removing cover glass fuse LED for system power +24 VDC (SP) 0 (SG) functional earth 2

Specifications PI module General Article description Article number Dimensions (XYZ) Weight Power consumption MTBF¹ Installation Material Connector type for power supply Permitted core cross section area Blue ID Power injection module 5050010 161.5 x 40 x 58 mm (6.36 x 1.57 x 2.28 inch) 150 grams 2.3 W 4,380,000 hours clicks onto DIN rail mixture of polycarbonate and ABS terminal block solid: 0.2 mm² 4 mm² flexible: 2.5 mm² flexible with ferrule connector: 0.25 mm² 1.5 mm² Indication green LED for status of module green LED for system power ¹ The MTBF is calculated according to the Telcordia SR-332 standard Issue 2 under the following conditions: - ambient temperature: 35 50 C - supply voltage: 24 VDC - time in operation per day: 24 hours - reliability level: 60 % 3

Electrical Input voltage Maximum input current Minimum switch off voltage Maximum switch off voltage Maximum voltage between: FE and SP FE and SG Capacity between: FE and SP FE and SG Resistance between FE and SG Protection Glass fuse Accuracy of internal temperature measurement Power supply The system power supply must comply with the following requirements. 21.6 VDC - 26.4 VDC (24 VDC ± 10 %) 2.5 A 21.1 VDC 26.9 VDC ± 43 V peak 1nF nominal 1 MΩ nominal input is protected against incorrect connection of ± 30 VDC and 30 VAC 2.5 AT ± 2 C Requirements output voltage: 21.6 26.4 VDC double insulation between input and output "limited-energy circuit" in accordance with IEC 61010-1 (maximum output current in normal operation or "single fault condition": 8 A) or maximum 4 AT external fuse between the power supply and the power supply input General specifications for controller, modules and bases Housing IP code Flammability class Recycle code Colour IP30 (NEN-EN-IEC 60529) FV-0 7 release surfaces of module and DIN rail release: blue (RAL5013) other parts: white (RAL9003) Mounting and connection Installation in control cabinet, accessible to authorised personnel only open device, to be used in an environment with a permitted pollution factor of 2 can be clicked onto mounting plate on horizontally or vertically positioned DIN rail Maximum width of I/O modules, bus extension modules and controller Environment Permitted temperature inside control cabinet during normal operation Permitted temperature inside control cabinet during transport and storage Permitted relative ambient humidity Shock and vibration resistance Installation category Permitted ambient pollution Note: The controller, SC module and SN module may only be mounted horizontally. 20 m 0 50 ºC 0 70 ºC 10 % - 95 % (non-condensing) IEC61131-2 II pollution degree 2 Legislation and standards Canada / USA CSA/UL approved, in compliance with: UL 61010-1:2004 (measurement and control equipment) CSA C22.2 No 61010-1-04 (measurement and control equipment) ICES-003 Issue 4 Class B 4

Legislation and standards Europe CE mark, in compliance with: Low voltage directive 2006/95/CE EMC directive 2004/108/EC RoHS directive 2011/65/EU in compliance with harmonised standard IEC 61010-1:2010 (3rd Edition) in compliance with WEEE Directive 2002/96/EC International The Blue ID S10 Controller is BTL registered at BACnet International. The Blue ID S10 Controller is BACnet certified in accordance with ISO 16484-5/6. Priva is a member of the BACnet Interest Group Europe. 5

Europe Office: UK Office: Canada Office: Your Priva partner: Priva Zijlweg 3 P.O. Box 18 2678 ZG De Lier The Netherlands T +31 174 522 600 F +31 174 522 700 www.priva.nl sales.building@priva.nl Priva Zijlweg 3 PO Box 18 2678 ZG De Lier The Netherlands T +44 (0)1923 813 480 F +44 (0)1923 813 499 www.priva.co.uk sales@priva.co.uk Priva North America Inc. 3468 South Service Road Vineland Station Ontario LOR 2E0 Canada T +1(905) 562-7351 F +1(905) 562-7717 www.priva.ca contact.priva@priva.ca 5201110_01.004_07-2013