Model UT371/372 OPERATING MANUAL

Similar documents
Sound Level Meter SLM700 AUDAC PROFESSIONAL AUDIO EQUIPMENT. Sound Level Meter SLM700. User Manual

RS Stock No Instruction Manual RS Input Data Logging Thermometer

Variable Temperature Digital Solder and Testing Station

ETHOS Auto Ranging Digital Multimeter

ATK-2040 AC/DC TRMS Watt Clamp Meter Users Manual

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER MAS830 MAS830L

Infrared Thermometer Remote Temperature Measurement ( Non-Contact ) TES-1326S INSTRUCTION MANUAL

374 FC/375 FC/376 FC. Clamp Meter. Safety Information

POCKET MULTIMETER Model No: MM18

Model A Mini AC/DC Clamp Meter. User's Guide

User Manual. 400Amp AC Clamp Meter + NCV. Model MA430. Additional User Manual Translations available at

R5050. Model. Instruction Manual. TRMS AC/DC Clamp Meter. reedinstruments. www. com

EARTH RESISTANCE & RESISTIVITY TESTER

9040/9040UK. Users Manual. Phase Rotation Indicator

DTM-321 REL HOLD T2 K-TYPE TEMP: 20 C 60 C 140 F C F HUMIDITY: %RH POWER-UP OPTIONS

Earth Resistance and Resistivity Tester

Manual Handheld Rotation Meter PCE-155

RS Stock No Instruction Manual RS Input Data Logging Thermometer

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

FengMi Wemax One Laser Projection TV

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

Mini Photo Tachometer Model Mini Contact Tachometer Model

User's Guide. 800 Amp Clamp Meters. EX710 AC Clamp meter EX720 True RMS AC Clamp meter EX730 AC/DC True RMS Clamp meter

User s Guide. 600A AC Clamp Meter. Model 38387

TITLE PAGE I. Safety Information II. General Description III. Specifications IV. Controls V. Calibration Procedures VI. Measurement Preparation

Self-Leveling Cross Line Laser Level with 3 Vertical Lines Model No Instruction Manual

Model INSTRUCTION MANUAL DIGITAL MULTIMETER

W Warning To avoid electrical shock, remove test leads and any input signals from the Model 707 Loop Calibrator before opening the case.

SOUND LEVEL CALIBRATOR DVM1356 INSTRUCTION MANUAL HANDLEIDING MANUEL D UTILISATEUR DVM1356 SOUND LEVEL CALIBRATOR 1

User's Guide. Extech AM A AC Analog Clamp Meter

SL 200 INTEGRATING-AVERAGING SOUND LEVEL METER

User s Guide. 600A True RMS AC/DC Clamp Meter. Model 38389

BetaProbe TI/TI+ High Accuracy Digital Thermometer. User Reference Manual

User Manual. Dual-Input Data Logging Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

User's Guide. EasyView K-Type Thermometer. Model EA11A

General Warranty. For more details, please refer to the user manual, it can be downloaded at

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

User Guide True RMS Multimeter Extech EX205T

CONTENTS Safety Information Description Features Specifications Nomenclature And Function Operating Preparation Calibration Procedure

5. Data Reference Data Deletion VIII. Replacing Batteries IX. Accessories... 17

User Manual. Single-Input Thermometers. with NIST-Traceable Calibration. Thermocouple Meter, Type J/K/T Input Model

High Performance Infrared Thermometer with High D:S Ratio, Adjustable Emissivity, and Built-in Laser Sighting

Model OPERATING MANUAL

USER MANUAL. True RMS Multimeter. Extech EX430A

SM-10 SM-20-A. Sound Level Meters. Users Manual. For detailed specifications and ordering info go to

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

ENGLISH. User manual

TC2100 HOLD MAX AVG MIN SETUP THERMOMETER. K T1-T2 F C mv TYPE KJTERSN USB MAX MIN AVG MEN. K INTERVAL hour:min POWER T1 T2.

INSTRUCTION MANUAL. Model True RMS AC/DC 30A Mini Clamp-on Meter. Introduction. True RMS AC Current and Voltage

Temperature Humidity Meter

ENGLISH. User manual.

Mini Digital Multimeter

Personal Sound Level Meter

CLAMP MULTIMETER METRACLIP 85 ENGLISH. Start Guide

RTD. Process Calibrator. User s MANUAL. PDF created with pdffactory Pro trial version

True RMS Multimeter with IR Thermometer

Autoranging Mini Multimeter

Digital Multimeter User's Manual

LM-100 LM-120 Light Meters Users Manual

User's Guide. Digital Multimeter. Model MN42

GLOSS METER OPERATION MANUAL

Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer. User's Guide

Digital Sound Level Meter

Model: Pro93 TRUE RMS LEAKAGE CURRENT TESTER

Sound Analyser Real Time 1/1 & 1/3 Octave band Analysis

Pro II. Sound Level Meter V-9992

Mini Digital Multimeter

ST-140 Vibration Meter ST-140D Datalogging Vibration Meter User s Manual

USER GUIDE. Dual Input True RMS AC Voltage/Current Datalogger. Model DL160

MS2115B Dual Display Digital Clamp Meter Operation Manual ZERO MIN RANGE HOLD

Test Products International, Inc SW Allen Blvd. Suite 104 Ph Beaverton, OR Fax

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

User Manual Extech EX820 True RMS 1000 Amp Clamp Meter with IR Thermometer

Mini Digital Multimeter Model MN15. User's Guide

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

Mini Digital Multimeter

SOLAR POWER METER TM-206. User s Manual HB1TM

SBS -600 Graphical Digital Multimeter SBS- 700 Multi-Function Oscilloscope. Quick Start Guide

Model R5010. TRMS Digital Multimeter. Instruction Manual

Model M140 Mini Solar Power Meter

CA846 THERMO-HYGROMETER ENGLISH. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Model R5010. Instruction Manual. TRMS Digital Multimeter. reedinstruments www.

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

Instruction Manual RS-1660

User Manual. Data Logging Light Meter. Model with NIST-Traceable Calibration THE STANDARD IN PRECISION MEASUREMENT

OPERATING INSTRUCTIONS

Sound Level Pen Instruction Manual

Instruction Manual LAN CABLE HiTESTER. March 2013 Revised edition A H

1366 INSTRUCTION MANUAL

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX310

Vibration Meter and Laser Combination Tachometer

Geo3X HP BEDIENUNGSANLEITUNG USER MANUAL MODE D EMPLOI

Sound Level Calibrator

COBRACAM PRO. Instruction Manual. Test Equipment Depot Washington Street, Melrose, MA TestEquipmentDepot.

Dear user, Thank you very much for purchasing LS533H rotary laser. Please read this instruction manual before operating it.

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

True RMS Multimeter with IR Thermometer

TC100 Precision Thermocouple Calibrator

Transcription:

Model UT371/372 OPERATING MANUAL

TABLE OF CONTENTS TITLE PAGE Overview Unpacking Inspection Safety Information Rules For Safe Operation International Electrical Symbols The Meter Structure Functional Buttons Setup Display Symbols Measurement Operation A. RPM Measurement B. Counts C. Data Transferring and USB 3 3 4 5 6 7 8 9 11 13 13 15 17 1

TABLE OF CONTENTS TITLE PAGE Specifications A. General Specifications B. Environmental Requirements Accuracy Specifications A. RPM B. Counts Maintenance A. General Service B. Replacing the Battery 18 18 19 20 20 20 21 21 22 2

Overview This Operating Manual covers information on safety and cautions. Please read the relevant information carefully and observe all the Warnings and Notes strictly. Model UT371 and UT372 is a stable, safe and reliable digital non-contact Tachometer. This Tachometer can measure RPM and counts. RPM range is 10 ~ 99999 while counts range is 0 ~ 99999. Unpacking Inspection Open the package case and take out the Meter. Check the following items carefully to see any missing or damaged part: Item 1 2 3 4 5 Description English Operating Manual Reflecting Tape USB Interface Cable (UT372 only) Software(UT372 only) 1.5V Battery (LR6) Qty 1 piece 10 pieces 1piece 1 piece 4 pieces 3

In the event you find any missing or damage, please contact your dealer immediately. Safety Information This Meter complies with the standards IEC61010-031, IEC61326, : in pollution degree 2 Use the Meter only as specified in this operating manual, otherwise the protection provided by the Meter may be impaired. In this manual, a Warning identifies conditions and actions that pose hazards to the user, or may damage the Meter or the equipment under test. A Note identifies the information that user should pay attention to. International electrical symbols used on the Meter and in this Operating Manual are explained on page 6. 4

Rules For Safe Operation Before using the Meter inspect the case. Do not use the Meter if it is damaged or the case (or part of the case) is removed. Look for cracks or missing plastic. Do not use or store the Meter in an environment of high temperature, humidity, explosive, inflammable and strong magnetic field. The performance of the Meter may deteriorate after dampened. Do not point laser directly at eye. Replace the battery as soon as the battery indicator appears. When the battery is between 4.5V ~4.8V, the battery indicator appears. When the battery is between 4.3V ~ 4.5V, battery indicator blinking, the Meter will be turned off after 1 minute. When opening the battery door, must make sure the Meter is power off. When servicing the Meter, use only the same model number or identical electrical specifications replacement parts. The internal circuit of the Meter shall not be altered at will to avoid damage of the Meter and any accident. 5

Soft cloth and mild detergent should be used to clean the surface of the Meter when servicing. No abrasive and solvent should be used to prevent the surface of the Meter from corrosion, damage and accident. Turn the Meter off when it is not in use and take out the battery when not using for a long time. Constantly check the battery as it may leak when it has been using for some time, replace the battery as soon as leaking appears. A leaking battery will damage the Meter. International Electrical Symbols Warning. Refer to the Operating Manual Deficiency of Built-In Battery Conforms to Standards of European Union 6

The Meter Structure (see figure 1) Tachometer Light Source. LCD Display. USB Port (UT372 only) Housing Functional Buttons Figure 1 7

Functional Buttons Below table indicated for information about the functional button operations. Button ON/OFF R/C M/M/A 8 Operation Performed Press once to turn the meter on. Press and hold for 1 minute to turn it off. When measuring RPM and Counts, press once to enter the Hold mode. Press it again to exit hold mode. When measuring RPM and Counts, press it to toggle between RPM and Counts feature. Press and hold for 1 minute to enter setup feature, the LCD displays USB. After that, each press to step through LED / SR / AOFF / CLK / exiting setup feature to enter RPM or Count. You could press ON/OFF button to exit setup mode and returning to normal measurement mode at any time. Press this button to choose maximum reading, minimum reading, average reading, zerong, Tune Under Tach measurement mode, press M/M/A button to select MAX/MIN/AVE and normal value measurement, After entering USB/LED/SR/AOFF/CLK mode, press this button to setup 0 or 1 and time. In the RPM or COUNT mode.press and hold the button for more than second the relative time will be clear and execute HOLD function In the COUNT mode pressing the button will be clear.

Setup A. USB setup Press R/C button to select USB feature after turning on the Meter. Then press M/M/A button to setup 0 or 1. 0 means turn the USB off. 1 means enable the USB feature. B. LED setup Press R/C button to select LED feature after turning on the Meter. Then press M/M/A button to setup 0 or 1. 0 means turn the LED laser off. 1 means enable the LED laser feature. C. SR sampling rate setup Press R/C button to select SR feature after turning on the Meter. Then press M/M/A button to setup 005 ~ 255. Press and hold M/M/A button to access quick setting. D. AOFF setup Press R/C button to select AOFF feature after turning on the Meter. Then press M/M/A button to setup 0 or 1. 0 is disable auto power off feature. 1 means enable auto power off feature, After enable auto power off feature, the Meter will be auto power off after ten minutes 9

if you do not press any button for 10 minutes. You could press ON/OFF button to turn on the Meter again after the Meter is off. E. CLK setup Press R/C button to select CLK feature after turning on the Meter. Then press M/M/A button to setup 0 or 1. 0 is hours and minutes format. 1 is minutes and seconds format. 10

Display Symbols (see figure 2) Figure 2 11

Number 1 2 3 4 5 6 7 8 9 10 11 12 Meaning Unit of Tachometer Unit of Counts Time The battery is low. Indicator of Sleep Mode Measurement of RPM and Counts Data Hold is on Display of Maximum reading Display of Minimum reading Display of Average reading USB is on Display of Measurement reading l 12

Measurement Operation Warning To reserve battery, the USB feature will be automatically off when the Meter is restarted. The other setting remains unchanged. The Time will be off after the HOLD feature is enabled. The time will be on again after existing HOLD mode. A. RPM Measurement (see figure 3) Warning Do not point laser directly at eye. When carrying out measurement, the distance must be more than 50mm. To avoid hurt yourself or damage to the meter, do not let speedy rotary object to touch the Meter. 13

To carry out RPM measuremnet, follow the following procedure: 1. Apply a piece of reflecting tape to the object under test. 2. Position the Meter on a flat place. Hold the Meter 50~200mm from the Tachometer light source to the object under test. 3. Press ON/OFF button, the Meter is default to enter the RPM measurement mode. Point the Tachometer light source to reflective tape, the vertical angle of the reflecting tape is not greater than 30. 4. The LCD displays the RPM reading. Note: 1. When measuring RPM, the LCD displays 0.0000 if there is no signal for continuous 7 seconds. 2. When the RPM reading is greater than 99999. the LCD displays OL. Figure 3 14

B. Counts Self-lighted Counts (see figure 4) 1. Position the Meter on a flat place. Hold the Meter 50~200mm and at the vertical angel not greater than 30 from the Tachometer light source to the object under test. 2. Press the ON/OFF button 3. Press the R/C button to select Count mode. 4. Point he Tachometer light source to the object under count 5. The LED scans the object under count, the Meter accumulates the counts and displays the quantity. Note: 1.The object under count must be reflective, otherwise Counts feature cannot be used Figure 4 15

Receiving Light Source Outside (see figure 5) 1. Position the Meter on a flat place. Hold the Meter 50~200mm and at the vertical angel not greater than 30 from the Tachometer light source to the object under test. 2. Set up the Meter, object under counts and outside light source as figure 5 3. Press ON/OFF button 4. Turn the LED off, refer to page 9 point B. 5. Then press R/C button to select Counts mode. 6. The object under count passes through between the Meter and the outside light source, the Meter accumulates the counts and displays quantity. Note: 1. Under the count mode, when the quantity is greater than 99999 RPM, the Meter displays OL and hold the data. 2. Press M/M/A button zeroing the Counts. 3. Press ON/OFF to re-start Counting. 16 Figure 5

C. Data Transferring and USB (UT372 only, see figure 6) Connect the USB interface cable, the Meter and the computer as per the figure 6. Figure 6 17

Specifications A. General Specifications Display: 5 digits LCD display, Maximum display 99999. Overloading: Display OL. Battery Deficiency: Display. Sampling Rate: 5 mini-second to 255 mini seconds adjustable. Transducer Tyype: Photo Diode and Laser Measurement Distance: 50mm ~ 200mm Drop Test: one meter Power: 4pcs x 1.5V batteries (AA) Dimensions: 184 x 56 x 34mm Weight: Approximate 100g (excluding battery) 18

B. Environmental Requirements For indoor use only. Altitude: 2000m Temperature and humidity: Operating: 0 o C~30 o C( 85%R.H) 30 o C~40 o C ( 75%R.H) 40 o C~50 o C ( 45%R.H) Storage: -20 o C~ +60 o C( 85%R.H) Safety/ Compliances: IEC61010-031, IEC61326, IEC 61010-1 pollution degree 2. Certification: 19

Accurate Specifications Accuracy: (a% reading + b digits), guarantee for 1 year. Operating temperature: 23 o C 5 o C Operating humidity: 80%RH Temperature Coefficient: 0.1 x (accuracy) / o C A. RPM Range Resolution Accuracy 10~99.999 r/min 100~999.99 r/min 1000~9999.9 r/min 10000~99999 r/min B. Counts 0.001 r/min 0.01 r/min 0.1 r/min 1 r/min (0.04%+2) Range Resolution Maximum input frequency 0~ 99999 1 digits 10kHz, Pulse Width 5% 20

MAINTENANCE This section provides basic maintenance information including battery replacement instruction. Warning Do not attempt to repair or service your Meter unless you are qualified to do so and have the relevant calibration, performance test, and service information. Do not attempt to open the back housing to avoid damaging to the Meter or affecting accuracy. A. General Service Periodically wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Turn the Meter power off when it is not in use. Take out the battery when it is not using for a long time. Do not use or store the Meter in a place of humidity, high temperature, explosive, inflammable and strong magnetic field. 21

B. Replacing the Battery (see figure 7) 1. Press ON/OFF to turn the Meter off. 2. Turn the Meter s front case down. 3. Remove the screw from the battery door, and separate the battery door from the case bottom. 4. Take out the old battery and replace with 4 x 1.5V battery (AA). 5. Rejoin the case bottom and the battery compartment, and reinstall the screw. 22 Figure 7

* END * This operating manual is subject to change without notice. 23

Copyright 2007 Uni-Trend Group Limited. All rights reserved. Manufacturer: Uni-Trend Technology (Dongguan) Limited Dong Fang Da Dao Bei Shan Dong Fang Industrial Development District Hu Men Town, Dongguan City Guang Dong Province China Postal Code: 523 925 Headquarters: Uni-Trend Group Limited Rm901, 9/F, Nanyang Plaza 57 Hung To Road Kwun Tong Kowloon, Hong Kong Tel: (852) 2950 9168 Fax: (852) 2950 9303 Email: info@uni-trend.com http://www.uni-trend.com 24