Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Similar documents
INSTALLATION GUIDE. Remote RMM-700 Intelligent Site Management Device. Installation Guide WESTELL.COM

RMB Peripheral Units Installation Guide

RMB-3 Peripheral Unit. Installation Guide INSTALLATION GUIDE WESTELL.COM. Westell Technologies Part # Rev. A

INSTALLATION GUIDE. Remote RMM-800 Intelligent Site Management Device. Installation Guide WESTELL.COM

AI130 AIswitch Series 130 Chassis Installation Guide

AI port High Speed Asynchronous Line Card Installation Guide

AI180I AIswitch Series 180 Integrated Chassis Installation Guide

Remote RMX-3200 Intelligent Site Management Device. Installation Guide

Replacing the Power Supply

TRC-190 User s Manual

Installing the Cisco AS5400XM Universal Gateway

TRC-190 User s Manual

Installing the Cisco 2524 and Cisco 2525 Routers

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

Junos WebApp Secure 5.0 Hardware Guide

Enclosure TS-530 User Manual

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Storage/Control I/O Module

Perle MCR200 Installation Guide

Hypercable injecteur HPOE - Industrial IEEE 802.3at Gigabit PoE Injector. User Manual. v.1.0 Jun Mail :

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

Installing the Cisco Unified Videoconferencing 3545 MCU

Power Supply and Fan Module Installation

Power Supply Installation

TCNM-ACBB1 Installation Manual

OPTICAL HEADEND PLATFORM OTOHP-CH 3RU CHASSIS OTOHP-PS POWER SUPPLY MODULE OTOHP-BP BLANK PANEL INSTRUCTION MANUAL

M40e and M160 CIP Installation Instructions

PIX 515/515E. PIX 515/515E Product Overview CHAPTER

Installation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis

USER MANUAL MODEL 2017P MODEL 2017P60. RS-232 to 20mA and. RS-232 to 60mA Current Loop Converters

User s Guide CPSMC0200-2x0 Dual-Slot PointSystem Chassis

Installation and Configuration Guide

An ISO-9001 Certified Company

This simple chassis houses one media-converter module and features an external AC power supply and also a terminal block for DC power input.

Perle SMI Media Converter Installation Guide

S4112-ON Series. Setup Guide

Installing Power Modules

WIRESPEED ADSL MODEM (MODEL 2000) User Guide

9. NTP-C11 Remove and Replace an Ethernet Card, page 1-13 As needed, complete this procedure to remove and replace an ONS CL Ethernet card.

LVN5200A-R2, rev. 1, Hardware Installation Guide

Installation and Maintenance

Before you begin. Unpack & Prepare. Install Hardware. Connect Hardware. Apply Power. Choose Management Method. Install & Use SANtricity Software

Install the Cisco ONS CL

Before you begin. Unpack & Prepare. Install Hardware. Connect Drive Trays. Apply Power. Connect Data Hosts. Choose Management Method

USER MANUAL. MODEL 1225 ParaLink TM Parallel Short Range Modem. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Installation Notes for the Catalyst 3750-X and 3560-X Switch Power Supply Modules

Hardware overview. Package contents MSM710, documentation, power supply, self-adhesive rubber feet.

Media Conversion Rack-Mount Chassis AT-MCR12. Installation Guide Rev. A

1. Carefully unpack the um260 s shipping carton and check the contents for damage.

Installing the Cisco SFS 3504 Server Switch

G.SHDSL NTU with Fixed Serial Interfaces

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

3710 ACM 3750 PDC 3800 RTU. ISOCOM Communications Card Retrofit Instructions

Mercury Helios ASSEMBLY MANUAL & USER GUIDE

iconverter 2-Module Power Chassis

XBR V4 INSTALLATION AND USER GUIDE

16-Port Chassis Media Converter System Manual

Installation Job Aid for Ethernet Routing Switch 3600 Series

PIX 520. PIX 520 Product Overview CHAPTER

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Preparing to Install the VG248

CPCI-PS24 24V-Power Supply

Modular Connectors 75

SIP 3CX Based Private Branch Exchange

FLEX Ex Spring Clamp Terminal Base

Installing and Removing SDRAM and DRAM

G.SHDSL NTU DECEMBER 2006 LB510A

TN-5308 Quick Installation Guide

hp uninterruptible power system r12000 xr models installation instructions

Release Notes. Electrostatic Discharge and Grounding Guide for Cisco NCS 2000 Series. Prerequisites. Preparing Your Location

Infinity 1U 19 Converter Shelf Models: J L217 - Individual +24V Inputs Bulk -48V Output L218 - Individual -48V Input Bulk+24V Output

Connecting Power and Ground

InnoMedia Business VoIP ATA Models

QFX10008 Switch Quick Start Guide

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

Installing the Cisco MDS 9020 Fabric Switch

Follow the procedure below for unpacking the carton in which the device is shipped. DW-GTW-AC-E1060 Four anti-slide bumpers for desktop installation

Fujitsu Stylistic ST4000 Series TABLET DOCK USER S GUIDE

MC 11 EB-2 Power supply cabinet with external bus, AC version

XBR V3 INSTALLATION AND USER GUIDE Rev 03. xbr V3 Installation and User Guide Page 1 of 14. (preliminary)

OWC Mercury Helios 2 ASSEMBLY MANUAL & USER GUIDE

Dell Networking S4810 Open Networking (ON) Getting Started Guide

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

DATA DOUBLER. Apple Mac mini (2009)

A TCP/IP network CAT 5 cable If the network is faster than 10baseT a switching hub will be needed Static IP address

H3C S12500 Routing Switch Series

Service Managed Gateway TM. Installing and Configuring the GW8600 SMG

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

Site Preparation CHAPTER

LNP series. 5-port Industrial PoE+ Unmanaged Ethernet Switches 4*10/100Tx (30W/Port) + 1*10/100Tx, 12~36VDC Input.

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

9109 FXS Analog Voice Application Module (APM) Installation Instructions. Product Documentation on the World Wide Web

Leased-Line Extenders over IP

SySTIUM TECHNOLOGIES. Assembly Guide. Model 133i

Installation Job Aid for VSP 4850GTS

PanelView Plus/VersaView CE Terminals and Display Modules

Transcription:

Remote RMM-1400 Intelligent Remote Site Management Device Guide INSTALLATION GUIDE Westell Technologies Part # 030-300645 Rev. A

Copyright 2015 by Westell Technologies. All Rights Reserved. Westell, Kentrox and Optima Management System are registered trademarks of Westell. All other names are trademarks of their respective owners. Information is correct at time of publication and is subject to change without notice. Contact Westell in Aurora, IL, to verify current product information. Westell Inc. is an Equal Opportunity/Affirmative Action employer. Westell Technologies 750 North Commons Aurora, IL 60504 USA Toll Free: (800) 377-8766 International: +1 (630) 375-4950 Fax: +1 (630) 375-4931 Page 0

Remote RMM-1400 Intelligent Remote Site Management Device Guide This installation guide explains how to install the Remote RMM-1400 intelligent remote site management device. Instructions for use of this product are detailed in the following documents: Remote RMM-1400 Command Reference Guide Remote RMM-1400 Configuration Guide Guide to this document Product Components Cautions and Warnings Customer Assistance Required Items Technical Specifications Page 1

Product Components Product Components Front Panel Components - Remote RMM-1400 Unit Status LEDs LED Status LED Description ALM Summary alarm LED: Illuminates when any point is in alarm state FLT Hardware failure LED: Illuminates when processor is not functioning, or when RMM-1400 has been powered up and bootloader is loading Blinks when bootloader has loaded and kernel is loading Tx/Rx SMA Female Cellular/PCS Antenna Diversity SMA Female Cellular/PCS Antenna DC Goes out when RMM-1400 bootup is complete DC Input Power LED: Illuminated when valid DC input power is applied to the unit ESD Ground Chassis Ground Asynchronous Serial Ports Serial ports 1 and 2 operate only in RS-232 mode. Serial ports 3 and 4 operate in RS-422 mode or RS-485 mode. Ethernet Switch Ports Input Power and Battery Monitor Connections Ethernet ports 1 and 2 provide PoE for RMBs. Pins 1 and 2 (Rx) provide negative (-) output. Pins 3 and 6 (Tx) provide positive (+) output. Page 2

Cautions and Warnings Cautions and Warnings Grounding and Electrical Safety CAUTION: Kentrox equipment and peripherals contain electrostatic sensitive components. Proper handling, shipping, and storage precautions must be exercised. CAUTION: For Kentrox equipment to operate safely and correctly, there must be a safety ground strap between the equipment ground bolts and the office ground. Environment CAUTION: In the event that Remote RMM-1400 has been subjected to adverse environmental conditions, a service inspection of Remote RMM-1400 should be made to ensure safe operation. Restricted Access Locations CAUTION: The Remote RMM-1400 is for use in restricted access locations only. FCC The Federal Communications Commission has set limits for emitted radio interference, and Remote RMM-1400 is constructed with this electromagnetic interference (EMI) limitation in mind. Remote RMM-1400 is classified under FCC regulations as a Class A device, that is, a device for use in commercial environments and not in residential areas. This device has been tested and shown to comply with the following FCC rule: Part 15 Subpart J. Operation of this equipment in a residential area may cause interference to radio and TV reception, requiring the user to take whatever steps are necessary to correct the interference. Information is available from the FCC describing possible corrective actions. To maintain low EMI levels, we suggest that you use only metal connectors and shielded cable grounded to the frame. Specifications are subject to change without notice. Page 3

Customer Assistance Customer Assistance All customers, partners, and resellers who have a valid Westell Support and Services Agreement have complete access to the technical support resources. Pre-sales Support Westell offers pre-sales technical support from 9 a.m. to 5 p.m. Eastern time, Monday - Friday. Representatives are standing by to assist with customer account information and product ordering and answer questions regarding Westell products and solutions. Phone number: 800-377-8766, option 1 Before you call or email Before you contact Westell for assistance, please have the following information available: The versions of hardware and software you are currently running The error number and exact wording of any messages that appeared on your screen What happened and what you were doing when the problem occurred How you tried to solve the problem Email Technical Support Email support is available. You may send email at any time during the day; however, responses will be provided only during normal business hours, in accordance with your Service and Support Agreement. To contact Technical Support, send email to: support@westell.com Telephone Technical Support Available to qualified Westell customers or partners who have not been able to resolve their technical issue by using our online services. To qualify for support, you must have a valid Support and Services Agreement. Phone number: 800-377-8766, option 2 Normal Business Hours: 8 a.m. to 6 p.m. Eastern time After-Hours Support: Available to qualified customers who are experiencing serviceaffecting outages that cannot wait until the next business day. To qualify for after-hours support, you must have a valid 24x7 Support and Services Agreement. Call the number above, option 2, and follow the prompts for after-hours service. Page 4

Customer Assistance Product Documentation You can also access and view the most current versions of Kentrox product documentation on our web site at: http://www.westell.com Page 5

Required Items Required Items Tools Materials #2 Phillips screwdriver Small flathead screwdriver (Phoenix 3 mm, recommended) 3/32 in. slotted screwdriver Crimping tool Wire cutter Wire stripper Grounding wrist strap Voltmeter, DC range PC or laptop with Kentrox Redirect software installed 10mm nut driver Wire punchdown tool (provided with RMB) Screws, sized to fit your rack Wire for input power connections (16 AWG solid or stranded insulated) Wire for ground connection (14 AWG, copper conductor) Ground lugs for rack or other earth ground Antioxidant Various required rack cables and cable assemblies Page 6

Step 1: Install Wireless Phone Module Hardware in Remote RMM-1400 If your Remote RMM-1400 includes the wireless phone module, follow these steps to install the necessary hardware: 1. Affix the FCC sticker (included with the phone module) to the product label on Remote RMM-1400. 2. Remove the top cover from Remote RMM-1400 by removing two screws from each side panel, then sliding the top cover to the rear of the unit to release the locking flange as shown below. Lift the top cover off the unit. Locking Flange Mounting Screws (left side - second screw Mounting Screws (right side) CAUTION: Kentrox equipment and peripherals contain electrostatic sensitive components. Proper handling precautions must be exercised. 3. Install two antenna terminals by inserting them through the holes provided in the front of Remote RMM-1400. Secure the terminals in place by attaching a nut and lock washer to each terminal, as shown below. 4. Install the phone module by inserting one end in the socket on the motherboard. Next, press down the other end of the phone module until it locks in place. Page 7

5. Attach two antenna leads from the antenna terminals to the phone module as shown below. 6. Insert the SIM chip in the socket on the motherboard. 7. Reinstall the Remote RMM-1400 top cover by placing the top cover on the chassis, sliding it forward until the flange locks under the faceplate, then reinserting two screws in each side panel. Nuts Antenna Terminals Lock Washers Antenna Leads Phone Module SIM Chip Page 8

Step 2: Attach Mounting Flanges to Remote RMM-1400 Attach the mounting flanges to fit a 19-inch or 23-inch rack. You can attach the flanges in alternate locations providing multiple alignment options to the rack. Mounting flanges oriented for a 19-inch rack Mounting flanges oriented for a 23-inch rack Page 9

Step 3: Attach Remote RMM-1400 to Rack Install mounting screws into the mounting holes and tighten firmly. No space is required between Remote RMM-1400 and any component mounted above or below Remote RMM-1400. Page 10

Step 4: Attach Chassis Ground Connect the chassis ground of Remote RMM-1400 to a suitable ground such as the frame ground of the rack system or a reliable earth ground. Caution: The chassis ground must be connected to the same earthing electrode conductor as the DC supply system or to a bonding jumper (from an earthing terminal or bus) connected to the earthing electrode of the DC supply system. The chassis must be located in the same immediate area (such as adjacent cabinets) as other equipment connected to the same DC power system and earthing electrode conductor. The DC system cannot be earthed elsewhere. The DC power source must be located in the same premises as the chassis. No switching or disconnecting devices can occur between the earthed conductor of the DC source and the earthing electrode conductor. Note: Apply an appropriate antioxidant to the bare conductors before crimping the connector to the connector mating surface. Note: For ground connection, use 14AWG or larger conductor. Page 11

Step 5: Connect Input Power WARNING: Turn off the power feed before connecting wires. Connect the input power feed to the power supply connector. Be careful to observe polarity. Caution: A readily accessible disconnect device (suitably approved and rated) must be incorporated in the field wiring. Unscrew these two screws to remove the power connector, if necessary. To connect wires: 1. Turn off power feed. 2. Strip ends of wire 5/16 in. (7 mm). 3. (optional) Using a small flathead screwdriver, loosen screws on sides of power connector on rear panel of Remote RMM-1400. 4. (optional) Remove power connector. 5. Using a 3/32 in. slotted screwdriver, loosen the six screws at top of connector. 6. Insert wire into connector and tighten screws. Notes: : Connect power connector to a reliably grounded -48 VDC safety extra-low voltage (SELV) source. Use 16 AWG or larger copper conductors. Typical circuit fuse: 3 A Page 12

Step 6: Mount RMB Mount the RMB peripheral unit to the wall, or in a rack. See the RMB Guide for instructions. Step 7: Connect RMB Inputs and Outputs RMB input and output connections are made using the supplied punchdown tool. See the RMB Guide for an explanation of RMB inputs and outputs. Step 8: Connect the Port Cables Connect all port cables per your application. Connecting RMM-1400 to RMB Use a standard CAT5 Ethernet cable (such as Kentrox part number CAB182-10) to connect one of RMM-1400 s PoE-enabled Ethernet ports to the Ethernet port on RMB. CAUTION: Kentrox recommends disconnecting the Ethernet PoE cable to RMB before wiring inputs and outputs in order to avoid electrical shorts. Connecting to an Asynchronous Serial Port Asynchronous serial ports allow terminal devices with asynchronous serial ports (such as PCs, NEs, and asynchronous modems) to connect to Remote RMM-1400. Use one of the following cables to connect one of the asynchronous serial ports (labeled SERIAL on the front panel) to an external device, such as a modem: 8-pin modular plug to 8-pin modular plug rollover DTE to DTE null RS-232 cable (part number CAB213) Male DB-25 to 8-pin modular plug DTE to DCE straight cable (part number CAB214) Female DB-25 to 8-pin modular plug DTE to DTE null RS-232 cable (part number CAB564) Female DB-9 to 8-pin modular plug DTE to DTE null RS-232 cable (part number CAB562) Note: Use shielded cable to ensure compliance with applicable emission standards. Connecting to a Switched Ethernet Port The switched Ethernet ports allow you to connect Ethernet-capable devices to Remote RMM-1400 and allow you to connect Remote RMM-1400 to a LAN. Use an 8-pin modular plug to 8-pin modular plug straight 100BaseT cable (such as Kentrox part number CAB182) to connect one of the switched Ethernet ports (labeled Page 13

ETHERNET on the Remote RMM-1400 front panel) to an Ethernet device on your network. Connecting Wires to RMB Punchdown Terminals To connect a wire to a punchdown terminal on RMB-1 or RMB-2: 1. Insert the wire in the slot in the top of the punchdown terminal and hold it in place. 2. Place the metal blade of the punchdown tool on top of the wire and press down firmly until the wire is seated in the bottom of the terminal. This action secures the wire in place and strips insulation from the wire. Pre-stripping the wire is not necessary. 3. Trim away any excess wire. 4. (optional) Gently tug the wire to ensure it is securely connected to the terminal. Step 9: Configure an IP Address Configuring the IP address allows Remote RMM-1400 to be accessed remotely. To configure the IP address: 1. Install Kentrox Redirect software on your laptop or PC. When the installation is complete, Kentrox Redirect and Kentrox Kickstart icons appear on your desktop. 2. Use a standard CAT5 Ethernet cable (such as Kentrox part number CAB182-10) to connect the PC or laptop to an Ethernet port on Remote RMM-1400. 3. Launch Kentrox Kickstart. Kickstart discovers the Remote RMM-1400 device, as shown below. Note: If the Remote RMM-1400 device is not discovered within one minute, select Help > About in Kentrox Kickstart, then click the Network Troubleshooting Guide link for instructions. 4. Click Telnet Terminal (or select Tools > Telnet Terminal). A Telnet window opens, displaying the Remote RMM-1400 login prompt. Page 14

Technical Specifications 5. At the Remote RMM-1400 login prompt, enter admin. This is the default login. 6. At the password prompt, enter password. This is the default password. 7. At the command prompt, enter config interface bridge switch ip address, followed by the IP address and subnet mask. For example: config interface bridge switch ip address 10.34.64.222 255.255.255.0 8. At the command prompt, enter config ip route default and the default gateway address. For example: config ip route default 172.10.11.222 Technical Specifications Table 1 Technical Specifications Specification Weight Size Mounting Operating Environment (Ambient) Power Fuse Ratings Input/Output Ports Description 3.35 lb (1.5 kg) Height: 1.6 in. (4.1 cm) Width: 11.8 in. (30.0 cm) Depth: 8.6 in. (21.8 cm) Mounts in a standard 19-in. or 23-in. rack Temperature: -30 to 60 C (-22 to 140 F) Relative humidity: 0% to 95% (non-condensing) Dual input (A/B feed), 40 watts maximum Input voltage range: +/- 20 to 60VDC (both power feeds must have the same polarity) In-rush: 3A maximum - no greater than 2A for no longer than 2ms 3 A at 60 VDC 4 10/100 BaseT Ethernet switch ports, 2 with PoE for RMB Peripheral Units 2 RS-232 asynchronous serial ports 2 RS-422/RS-485 asynchronous serial ports 2 20-60 VDC power inputs with voltage monitoring 1 auxiliary 0-60 VDC voltage monitoring input Page 15