TOT Series Manual. North American CE and UK Models. CE Models. UK Models. North American Models

Similar documents
TOT Series Manual. North American and International Models - without optional faceplate. Receptacle Panel of International Models, CE model shown

Owner s Manual. Isolate. Restore. Inspire! Power Conditioners Audio / Video Power Isolation Units Rack Mount / Consumer Series

IS Series Manual. 19 Pro Series Rack Mount (RK) Faceplate. 17 Consumer Series (C) Faceplate Available in Black (B) and Silver (S) colours

TOT AVR Series Manual

POWER ISOLATION PRODUCTS BIT-5 BIT-15 BIT-20

AVR Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation. 19 Pro Series Rack Mount (RM) Faceplate

AVR Series Manual. Isolate. Restore. Inspire! Audio / Video Power Isolation Units with Automatic Voltage Regulation

AVR Manual. Toroidal. Isolation. Power. Conditioning. Audio / Video Power Isolation Units with Automatic Voltage Regulation

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

PCM60A 100W MAX P.A. AMPLIFIER.

SUBWOOFER SYSTEM YST-MSW10

YST-SW20 SUBWOOFER SYSTEM OWNER S MANUAL. Active Servo Technology

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

PS8 - II. Professional Power Sequencer. User s Manual

RETAIL Price List - Valid From June 2017

AVR Series Manual. Toroidal Isolation Power Conditioning Automatic Voltage Regulation Surge Protection

TVA2.1 2-Channel Digital Amplifier Installation Manual

MODEL 805 USER MANUAL

VOICE-ACTIVATED INTERCOM SYSTEM

Blonde On Blonde OWNER S MANUAL SWR SCOTTSDALE, AZ USA

MPF-1, Mains Power Filter User Manual

7-Port Fast Charging Station NAP Instruction Manual Please read carefully before use and keep for future reference.

CANTEEN 6000 Portable Battery Pack NAP-30. Instruction Manual Please read carefully before use and keep for future reference.

Thank you for your purchase of the Supa-Charger! Features Include:

OWNER S MANUAL CD-2 V 1.3

CANARY AUDIO. Vacuum Tube Compact Disc Player CD-100 OWNER S MANUAL. Handcrafted in California MADE IN USA

CANARY AUDIO CA-430. Vacuum Tube MM/MC Phono Preamplifier OWNER S MANUAL. Handcrafted in California MADE IN USA

Installation Manual. 12 Volt Power Supplies. 18-Port. 9-Port RET18PT RET9PT

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

music hall a70.2 integrated amplifier music hall

What s in the Box. Table of Contents

Neets Switching Relay - 2. Installation manual

English MP210. Français. Multimedia Speaker. User Manual. Please read this manual carefully before operating the Speaker System

Rack Mount Power Supplies

Obtaining Documentation and Submitting a Service Request, page xvii Safety Warnings, page xvii Safety Guidelines, page xx

HSC-42. HDMI 4k2k Video Up/Down Scaler

Zphono Phono Preamplifier

INSTALLATION MANUAL. HDMI 1x8 Splitter B-230-HDSPLTR-1x8 B-230-HDSPLTR-1X8

Owner s Manual. MOON Series 320 S. Power Supply

R290DS Dual Source Power Amplifier Installation Manual

THANK YOU! CR120H. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

a35.2 integrated amplifier a35.2

FOR FURTHER INFORMATION CONTACT: Music Hall 108 Station Road Great Neck, NY Tel: Fax:

OWNER S MANUAL. Additional Camera Unit AC-CAM-210 Compatible with AC210 Baby Video Monitor TABLE OF CONTENTS

OLi POWA-5 Active Monitors

INSTALLATION MANUAL. HDMI 1x4 Splitter B-230-HDSPLTR-1x4. B-230-HDSPLTR-1x4 HDMI OUT 4 HDMI OUT 3 HDMI OUT 2 HDMI OUT 1 HDMI OUT 4 HDMI IN

BUC-1 DIGITAL-TO DIGITAL CONVERTER

LTC 5121, LTC 5141 Series 2- and 4-Position Economical Sequential Switcher

Important Safety Instructions

THANK YOU! Crush PiX 20L. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

Compact USB Digital Speakers. Quick Start User Guide

CONTENT COMPONENTS OF PROJECTOR... 2 SPECIFICATION... 3 INSTRUCTION MANUAL... 3 CHARGING THE PROJECTOR... 3 SET UP... 4

PLTT21BT CLASSICAL TURNTABLE WITH USB PLAYER, BLUETOOTH INSTRUCTIONS MANUAL

Cantata m100 Amplifier

PS 289 DUAL CHANNEL POWER SUPPLY USER MANUAL

Innovative K5 Palm Size LED Projector.

SubCast Transmitter/Receiver Subwoofer Kit

B&W RearView Camera Installation & Operation

Ares. Modular Audiophile System. by Thrax Audio. Operating Manual. Manual issued 15/03/2018 CAUTION

CD/Radio Portable Player

RTT98 VINTAGE TURNTABLE

DVI KVM. Extra Long Range Extender Over One CAT5. User Manual EXT-DVIKVM-ELR. Release A8

Users Manual. Pronomic TAS-18 Active Touring System

music hall dac15.2 digital to analog converter INSTRUCTION MANUAL music hall

Network Camera. Quick Guide DC-B1203X. Powered by

PS-20. Power Supply. User Manual Rev F

DUAL MONO POWER AMPLIFIER INSTRUCTIONS FOR USE

BOT-1 Optical Transport Owner s Manual

TECHCONNECT TC2-HDMI14 OWNERS MANUAL

Kogan Bluetooth Karaoke System with Dual Microphones KAKAR2MICA

VeniceU16/VeniceU24/VeniceU32

OWNER S MANUAL GEQ 131/ 131LF GEQ 215/ 215LF GEQ 231. Single Channel 31 Band Graphic Equalizer. 2 Channel 15 Band Graphic Equalizer

Additional Camera Unit for Angelcare Monitors AC-CAM Compatible with models: AC517 - AC510 AC417 AC315 AC310

DMX Tool Splitter 1 to 5 User Manual

HDMI 1x2 Splitter B-230-HDSPLTR-1x2 INSTALLATION MANUAL HDMI OUT 2 HDMI OUT 1 B-230-HDSPLTR-1X2 POWER HDMI IN

THANK YOU! Crush PiX 20LDX. Thank you for choosing Orange. You are now a member of the Legendary British Guitar Amplifier owners club!

Monochrome Camera. Features. User manual

SMART Hi-Fi AUDIO *MFL * SJ8 SIMPLE MANUAL. Wireless Multi-room Sound Bar

EC Series. Safety Guide

PORTABLE WIRELESS PA SYSTEM WITH LITHIUM -ION RECHARGEABLE BATTERY AWP6042 OWNER S MANUAL. Handheld Microphone Headset Transmitter

Quick Guide. ENC-H Video Encoder XX

Neutrik 20A powercon with 2nd order EMI filter & GDT/VDR protection circuit against Lightning Strike & Local Power Surge Circuit A

U-300 Unity Amplifier User s guide

Antenna Distributor ORDERCODE D1444

DAB A d a pt e r 3+ Dear Customer,

P125 Dual Source Power Amplifier Installation Manual

Active UTP Transceiver Hub with Integral Isolated Camera Power

PS 680 SIX CHANNEL POWER SUPPLY WITH AUX MATRIX USER MANUAL

CPD SERIES OPERATING MANUAL AND USER GUIDE. Professional Power Amplifier.

3-Speed Vintage Turntable

DUAL LASER PACK & CONTROLLER USERS MANUAL

CS-1 Active Full Range Integrated Commercial Audiovisual System

MS-SL12-RD. 17-Outlet LCD Display Power Strip 20Amp INSTRUCTION MANUAL

CANARY AUDIO. Vacuum Tube Compact Disc Player CD-200 OWNER S MANUAL. Handcrafted in California MADE IN USA

Safety. Features 1 ID: Make all the connections before you plug in the main power. DMX512 Controllable and RDM Configurable

Owner s Instruction Manual

Qi Wireless & USB Charger with Bluetooth Speaker NAP-52. Instruction Manual Please read carefully before use and keep for future reference.

USERS GUIDE MCX-VTH. VGA to HDMI Converter. Manual Number:

Transcription:

TOT Series Manual North American CE and UK Models CE Models UK Models North American Models

Table of Content 1. Important Safety Instructions 2. Description Shipping Carton & Packing Material Placement & Ventilation Warranty 3. Front Panel Layout Rear Panel Layout 4. Electrical / Mechanical Specifications Circuit Protection Input Current Rating TOT Key Features Optimal Usage 5. Circuit Schematic: North American TOT MINI & TOT MINI SMSS 6. Circuit Schematic: North American TOT MAX & TOT MAX SMSS 7. Circuit Schematic: International TOT MINI CE & TOT MINI CE SMSS 8. Circuit Schematic: International TOT MAX CE & TOT MAX CE SMSS 9. Circuit Schematic: International TOT MINI UK & TOT MINI UK SMSS 10. Circuit Schematic: International TOT MAX UK & TOT MAX UK SMSS 11. Layout TOT MINI & TOT MINI SMSS 12. Layout TOT MINI CE & TOT MINI CE SMSS 13. Layout TOT MINI UK & TOT MINI UK SMSS 14. Layout TOT MAX & TOT MAX SMSS 15. Layout TOT MAX CE & TOT MAX CE SMSS 16. Layout TOT MAX UK & TOT MAX UK SMSS

Important Safety Instructions CAUTION! To reduce the risk of electric shock and fire, do not remove the cover of this device. There are no user serviceable parts inside. Please refer all servicing to licensed service technicians. CAUTION! The international symbol of a lightning bolt inside a triangle is intended to alert the user to uninsulated dangerous voltage within the device s enclosure. The international symbol of an exclamation point inside a triangle is intended to alert the user to the presence of important operating, maintenance and servicing information in the manual accompanying the device. CAUTION! To prevent electrical shock, match wide blade of plug to wide slot, fully insert. CAUTION! To reduce the risk of electrical shock, do not expose this equipment to rain or moisture. 1. Read Instructions All safety and operating instructions should be read before operating the device. 2. Retain Instructions The safety and operating instructions should be retained for future reference. 3. Heed Warnings All warnings on the device and in the operating instructions should be adhered to. 4. Follow Instructions All operating and safety instructions should be followed. 5. Water & Moisture The device should never be used in, on or near water for risk of fatal shock. 6. Ventilation The device should always be located in such a way that it maintains proper ventilation. TOT Series Stand-Alone models should never be placed in a built-in installation or anywhere that may impede the flow of air through its ventilation slots. 7. Heat Never locate the device near heat sources such as radiators, floor registers, stoves or other heat-generating devices. 8. Power Cord Protection Power cables should be routed so they are not likely to be stepped on or crushed by items placed on them or against them. Special attention should be paid to areas where the plug enters a socket or fused strip and where the cord exits the device. 9. Periods Of Non-Use The device should be unplugged when not being used for extended periods. 10. Dangerous Entry Care should be taken that no foreign objects or liquids fall or are spilled inside the device. 11. Damage Requiring Service The device should be serviced by licensed technicians when: The plug or power supply cord has been damaged. Objects have fallen or liquid has spilled inside the device. The device has been exposed to moisture. The device does not appear to be operating properly or exhibits a marked change in performance. The device has been dropped or the enclosure becomes damaged. 12. Service The device should always be serviced by licensed technicians. Only replacement parts specified by the manufacturer should be used. The use of unauthorized substitutions may result in fire, shock, or other hazards. 13. Do not position the equipment so that it is difficult to operate the disconnecting device (power cord). 14. If the equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. 15. The power switch should be in the off position when connecting or disconnecting equipment from a Torus Power unit. 16. CAUTION Some units can be very heavy, please use safe practices when lifting. 18 kg (39.7 lb) 32 kg (70.5 lb) 55 kg (121.2 lb) 1

Description Torus Power TOT Mini and TOT Max are ultra compact toroidal isolation power conditioners, and the most affordable products in the Torus line-up. The compact footprint and sloped face of TOT models make them convenient for use in almost any situation. They look sharp on a component shelf, or can be located elsewhere when space is at a premium. The TOT Mini is rated at 7A (North American version), and 3A (International). It is the ideal accessory to provide true toroidal power conditioning for small or mid-power AV systems, or dedicated to video components (ie. flat panel TVs, projectors); or audio components (i.e. media sources, powered speakers, source components, etc.). The TOT Max is rated at 15A (North American version) and 8A (International), and can be used in systems up to the rated output current. TOT models provide a convenience USB-type charger as a bonus feature. TOT models provide basic circuit protection: series mode surge protection is available as a factoryinstalled option. TOT Mini is designed to fit between studs spaced at 16 for in-wall installations. A factory installed in-wall mounting kit is available. Shipping Carton & Packing Material Placement & Ventilation Please keep the original shipping box and all packing material. This will ensure the TOT is protected in future transport. In the unlikely event you have a problem and must return it for service you must use the original packing material. Ship the TOTs only in the original packing material, as the unit is not insurable by carriers otherwise. Torus Power TOTs are extremely efficient devices, however, they are also very high-power devices, and must be adequately cooled. TOT MAX units have ventilation slots on the base and side panels. Maintain at least 2.5cm distance from each of these surfaces to anything else. Should your installation conditions be constricted, additional forced air-cooling may be necessary. Do not install the TOT directly above heat-generating equipment. Maintain at least 15cm behind the TOT for adequate wiring space. Warranty Torus Power products are warranted to be free from manufacturing defects for five years from the original date of sale. This includes parts, labour and return shipping to the first registered owner and all subsequent registered owners. Warranty coverage is extended to applicable products registered or having proof-of-purchase (sales invoice, etc.). This warranty is considered void if the defect, malfunction or failure of the product or any component part was caused by damage (not resulting from a defect or malfunction) or abuse while in the possession of the customer. Failure to fully comply with Torus Power operating instructions, voids the warranty. In the event of a defect or malfunction, Torus Power will remedy the problem by repair or replacement, as we deem necessary, to restore the product to full performance. 2

Front Panel Layout ON/OFF Illuminated Power Switch RK Faceplate (RK Faceplate shown in Silver above is also available in Black Anodize as well) North American Model Numbers TOT MINI and TOT MAX. International Model Numbers TOT MINI CE, TOT MAX CE, TOT MINI UK, TOT MAX UK, Rear Panel Layout International Models CE Power Outlet (SCHUKO CEE 7/7) Model Number TOT MAX CE Model Number TOT MINI CE Power Inlet Rubber Mounting Feet (may be removed if Wall or Rack mounting) International Models CE Model Number TOT MAX UK Model Number TOT MINI UK Power Outlet (Inter Power UK) North American USB Charger Power Outlet (North American 5-15R) Fuse Holder Model Number TOT MAX North American Model Numbers TOT MINI North American Owner s Manual Power Conditioners 3 Audio / Video Power Isolation Units TOT Series Manual

Electrical / Mechanical Specifications NORTH AMERICAN 120V INTERNATIONAL 220V - 240V INTERNATIONAL 220V - 240V MODEL TOT MINI TOT MAX TOT MINI CE TOT MAX CE TOT MINI UK TOT MAX UK CONFIGURATION CHASSIS HEIGHT SAU (Stand-Alone Unit), RK (Rack Mount), IW (In-Wall Mount) 2U INPUT VOLTAGE 120V 220V - 240V OUTPUT VOLTAGE 120V 220V - 240V INPUT PROTECTION 1 X 7A FUSE 1 X 15A FUSE 1 X 3A FUSE 1 X 8A FUSE 220V - 240V 220V - 240V 1 X 3A FUSE 1 X 8A FUSE OUTPUT CURRENT RATING 7A 15A 3A 8A POWER RATING 840VA 1800VA 696VA 1840VA 3A 696VA 8A 1840VA FREQUENCY 60Hz 50/60Hz NUMBER OF OUTLETS 6 8 3 4 INLET TYPE IEC 15A (UL) (SAU and RK) IEC 15A ( UL) (SAU and RK) OUTLET TYPE NORTH AMERICAN 5-15R SCHUKO CEE 7/7 50/60Hz 3 4 IEC 15A ( UL) (SAU and RK) INTER POWER UK OUTPUT USB 5.1VDC nominal / 2300mA maximum WEIGHT (SAU) 25.1 lbs (11.4kg) 38.9 lbs (17.7kg) 25.5 lbs (11.6kg) 49.5 lbs ( 22.5kg) WEIGHT (RACK) 26.0 lbs (11.8kg) 39.8 lbs (18.1kg) 26.4 lbs (12.0kg) 39.8 lbs (18.1kg) 25.5 lbs (11.6kg) 49.5 lbs ( 22.5kg) 26.4 lbs (12.0kg) 39.8 lbs (18.1kg) WEIGHT (IN-WALL) 29.5 lbs (13.4kg) 43.3 lbs (19.7kg) Not Applicable Not Applicable Not Applicable Not Applicable DIMENSIONS (SAU) WxHxD DIMENSIONS (RACK) DIMENSIONS (IN-WALL) 318x101x262 (12.5x4.0x10. 3) 480x88x271 (18.9x3.4x10.7) 419x90x381 (16.5x3.6x15.0) 318x101x363 (12.5x4.0x14. 3) 480x88x373 (18.9x3.4x 14.7) 419x90x483 (16.5x3.5x19.0) 318x101x262 (12.5x4.0x10. 3) 480x88x271 (18.9x3.4x10.7) Not Applicable 318x101x363 (12.5x4.0x14. 3) 480x88x373 (18.9x3.4x14.7) Not Applicable 318x101x262 (12.5x4.0x10. 3) 480x88x271 (18.9x3.4x10.7) Not Applicable 318x101x363 (12.5x4.0x14. 3) 480x88x373 (18.9x3.4x14.7) Not Applicable OPTIONS AVAILABLE: Series Mode Surge Suppression (factory installed) 19" Rack Faceplate/Adapter Kit (Silver and Black Anodized) In-Wall Adapter Kit Available For North American Models Circuit Protection The TOT models come with a replaceable fast acting fuse 1/4 x 1-1/4 (6.35mm x 32mm) on the input side of the unit. When the power is on, the switch is illuminated. 4

Circuit Schematic North American Model TOT MINI Circuit Schematic North American Model TOT MINI SMSS 5

Circuit Schematic North American Model TOT MAX Circuit Schematic North American Model TOT MAX SMSS 6

Circuit Schematic International TOT MINI CE Circuit Schematic International TOT MINI CE SMSS 7

Circuit Schematic International TOT MAX CE Circuit Schematic International TOT MAX CE SMSS 8

Circuit Schematic International TOT MINI UK Circuit Schematic International TOT MINI UK SMSS 9

Circuit Schematic International TOT MAX UK Circuit Schematic International TOT MAX UK SMSS 10

Layout TOT MINI & TOT MINI SMSS SMSS An SMSS (Series Mode Surge Suppressor) is available for this unit on request. This is an installation drawing for the TOT MINI. The four rubber feet at the base of the unit are removable to bolt the unit to a surface. All units are 2U height Faceplate -RK faceplate, width is 19 -Shelf-type faceplate, width is 12.5 11

Layout TOT MINI CE & TOT MINI CE SMSS SMSS An SMSS (Series Mode Surge Suppressor) is available for this unit on request. This is an installation drawing for the TOT MINI CE. The four rubber feet at the base of the unit are removable to bolt the unit to a surface. All units are 2U height Faceplate -RK faceplate, width is 19 -Shelf-type faceplate, width is 12.5 12

Layout TOT MINI UK & TOT MINI UK SMSS SMSS An SMSS (Series Mode Surge Suppressor) is available for this unit on request. This is an installation drawing for the TOT MINI UK. The four rubber feet at the base of the unit are removable to bolt the unit to a surface. All units are 2U height Faceplate -RK faceplate, width is 19 -Shelf-type faceplate, width is 12.5 13

Layout TOT MAX & TOT MAX SMSS This is an installation drawing for the TOT MAX. The four rubber feet at the base of the unit are removable to bolt the unit to a surface. All units are 2U height Faceplate With RK faceplate, width is 19 Shelf-type faceplate, width is 12.5 SMSS An SMSS (Series Mode Surge Suppressor) is available for this unit on request. 14

Layout TOT MAX CE & TOT MAX CE SMSS This is an installation drawing for the TOT MAX CE. The four rubber feet at the base of the unit are removable to bolt the unit to a surface. All units are 2U height Faceplate With RK faceplate, width is 19 Shelf-type faceplate, width is 12.5 SMSS An SMSS (Series Mode Surge Suppressor) is available for this unit on request. 15

Layout TOT MAX UK & TOT MAX UK SMSS This is an installation drawing for the TOT MAX UK. The four rubber feet at the base of the unit are removable to bolt the unit to a surface. All units are 2U height Faceplate With RK faceplate, width is 19 Shelf-type faceplate, width is 12.5 SMSS An SMSS (Series Mode Surge Suppressor) is available for this unit on request. 16

Torus Power products are marketed worldwide through Plitron Manufacturing Inc. 11/15 For sales contact: torussales@plitron.com Phone: 416-667-9914 Toll free: 1-800-754-8766 Fax: 416-667-8928 Technical inquiries: torustechnical@plitron.com Phone: 416-667-9914 Torus Power #8 601 Magnetic Drive Toronto, ON M3J 3J2 Canada 416-667-9914 Specifications subject to change without notice. Torus Power 2015