Assembly and operating instructions DULCOMARIN II, P-Module (Power Supply Module with Relay) DXMaP

Similar documents
Assembly and operating instructions DULCOMARIN II, N-Module (Power Supply Module without Relay) DXMaN

Please enter the identcode of your module!

Please enter the identcode of your module!

16 pools with just one central unit with ProMinent The new swimming pool controller DULCOMARIN II

Please enter the identcode of your controller!

ProMinent DDC Analyzers

Operating instructions. Switching amplifier DN0210 DN / / 2015

ProMinent. Supplementary Instructions Embedded Web Server, LAN for DULCOMARIN II DULCO -Net

Please enter the identity code of your device here!

Operating instructions. Standstill monitor A / / 2011

Electronic Temperature Controller. Instruction Manual Version

Please carefully read these operating instructions before use! Do not discard! Damages due to improper operation will invalidate the warranty!

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions. Speed monitor D / / 2014

Please enter the identity code of your device here!

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Non-communicating room controllers

Operating Instructions

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

M-Module Please enter the identcode of your module!

BMF400 Input/output module

PSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1

ABB i-bus KNX HCC/S Heating/cooling circuit controller

Power supply. Interface technology in modular housing DIN rail devices, IM series. Features

Neon pr. ph/ ORP measurement. Applications. Description

Non-communicating room controllers

PSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B

Description. Monitoring functions Evaluation of brush length monitoring, digital, non-floating A00

QUINT-PS/ 1AC/24DC/ 5

Siemens AG /24RC 12/24RCo

External level devices for conductive point level switch

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Operating Instructions

ETD-BL-1T-230(-PT) Multifunctional time relay with various functions and adjustable times. Data sheet. 1 Description

Supplementary operating instructions for your air curtain system Controller TMC 500

THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. I/O expansion modules. Modules from the

Installation / Control Technique

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

HydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller

RMZ782B RMZ783B. Extension Modules. Building Technologies HVAC Products. Synco 700. for heating controller RMH760B

Zenith DS9000 Dispensing System

ABB i-bus KNX Fan Coil Actuator, PWM, MDRC FCA/S , 2CDG110195R0011

Installation and configuration manual DULCOnvert PROFIBUS - PROFINET converter

SIMOREG 6RA70 DC MASTER SIMOREG CM

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Interface and Supply module. IPC 3x0i / PSC 3x0i

QUINT-PS AC/24DC/10

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

Fan Coil Actuator, MDRC FCA/S 1.1M, 2CDG R0011

Universal Modules. Synco 700. Extension modules for use with controls of the Synco 700 family. Use

ABB i-bus KNX Analogue Actuator, 4-fold, MDRC, 0-10 V, 0-20 ma AA/S 4.1.2, 2CDG110202R0011

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

Expansion Module HZS 541-1S

16-Channel Digital Input Termination Card 24Vdc

CMC III Universal Sensor

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

Products no longer available

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

I/O module (Expansion module)

PSR DC/ESP4/2X1/1X2

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

SEH62.1. Digital Time Switch

16-Channel Digital Input Termination Card 24Vdc

DEIF A/S. TAS-331DG Selectable AC transducer G (UK) Installation and start up instructions. Watt or var transducer

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

QXA2000 QXA2001. Condensation Monitor QXA2001 QXA2000 AQX2000

PHOENIX CONTACT Features

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

PHOENIX CONTACT - 07/2006

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

PSR UC/ESAM4/3X1/1X2/B

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

PTC/PT100 board 2.0 Option

Operating Manual -ENGLISH- Page 1 KWG-ISO

Article No. 6GK59230PS003AA2 6GK59240PS001AA2 Product Name. Power Supply SCALANCE PS924 PoE Input: 120/230V AC; Output: 54V/ 1.

Field module for cold locations for installation in refrigerators for direct control of a pulsed expansion valve

AB Axis Industries. Use

ABB component drive ACS50, 0.18 to 2.2 kw Technical catalogue PRODUCTS

ABB i-bus KNX Weather Unit, 1-fold, MDRC WZ/S , 2CDG110184R0011

ABB i-bus KNX Analogue Input, 4-fold, MDRC AE/S , 2CDG110190R0011

ABB i-bus KNX Switch Actuator, x-fold, 10 A, MDRC SA/S x , 2CDG11015xR0011

GENERAL SAFETY GUIDELINES

EMD-SL-LL-230. Electronic monitoring relay for level monitoring of conductive liquids. INTERFACE Data sheet _en_04. 1 Description.

Operating instructions AC010S Compact AS-i E-STOP safety module

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Overview of types. Technical data

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

EXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

GRASSO SYSTEM CONTROL

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

16-Channel Input Digital Input Termination Card

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

OPERATING INSTRUCTIONS

Transcription:

Assembly and operating instructions DULCOMARIN II, P-Module (Power Supply Module with Relay) DXMaP A0479 Please enter the identity code of your device here! DXMa _ Please carefully read these operating instructions before use! Do not discard! The operator shall be liable for any damage caused by installation or operating errors! Technical changes reserved. Part no. 986903 BA DC 074 02/11 EN

ProMinent Dosiertechnik GmbH Im Schuhmachergewann 5-11 69123 Heidelberg Telephone: +49 6221 842-0 Fax: +49 6221 842-419 email: info@prominent.de Internet: www.prominent.com 986903, 1, en_gb 2011 2

Supplemental instructions Further applicable documents These operating instructions and supplementary instructions are only valid in combination with the following operating and supplementary instructions: Multi-channel measuring and control system operating instructions DULCOMARIN II Swimming Pool Controller and Disinfection Controller DXCa Part 1: Assembly and installation Multi-channel measuring and control system operating instructions DULCOMARIN II Swimming Pool Controller and Disinfection Controller DXCa Part 2: Operation 3

Table of contents Table of contents 1 Identity code... 5 2 About this device... 7 2.1 Safety chapter... 7 2.2 Storage and transport... 7 3 Assembly and installation... 8 3.1 Repairs (fuse change only)... 10 3.2 Arrangement of LEDs... 11 3.3 Example for connection of a solenoid valve... 12 4 Technical data... 13 4

Identity code 1 Identity code The identity code describes the external modules for the DULCOMARIN II, series DXM Only the M module of mounting type W Wall mounting can be ordered with operating elements and with different languages. DXMa External modules for the DULCOMARIN II, series DXM Module: M A M module, measuring module: ph, redox, temperature A module, control module: 3 pumps and 4 analog outputs R R module, control module: Chlorine gas metering device with feedback N N module, power supply module without relay P P module, power supply module without relay, only mounting type 0) 2) 1) 2) 1) 2) I I module, current input module, 3 ma inputs, 2 digital inputs Mounting type: 0 Without housing, only P-module (IP 00) W Wall mounted (IP 65) H Mounting rail (IP 20) E Upgrade module (insert module for DXCa, IP 20) Version: 0 With controls 2 Without controls 3 Without controls (only mounting type E ) Application: 0 Standard S Swimming pool (only m module) Language: 00 No controls 2) DE EN ES FR IT German English Spanish French Italian Certification: 5

Identity code DXMa External modules for the DULCOMARIN II, series DXM 00 No certification, only P-module without housing 01 CE mark 1) only mounting type W wall mounting / 2) only in version 2 without controls 6

About this device 2 About this device The power supply module with relay DXMaP with alarm relay and solenoid valve relay supplies the DULCOMARIN II compact with mains voltage and allows it to control 3 solenoid valves or hose pumps via pulse frequency e.g. to: raise / lower the ph value meter disinfectant meter flocculant minimise combined chlorine The DXMaP power supply module has the following outputs: power relay for alarm output power relay output for solenoid valve or hose pump (ph correction) power relay output for solenoid valve or hose pump (disinfectant) power relay output for hose pump (flocculant) or relay output (minimising of combined chlorine) one mains input 2.1 Safety chapter CAUTION! Safety when using the P module The DXMaP power supply module with relay must only be used to control alarm horns, solenoid valves and hose pumps as well as to provide the power supply for the DULCOMARIN II DXCa. The DXMaP power supply module with relay must only be used as part of the DULCOMARIN II. The installation must only be carried out by technically trained personnel. 2.2 Storage and transport CAUTION! Protect the module against moisture and the effects of chemicals, even while still packaged. Store and transport the module it its original packaging. Ambient conditions for storage and transportation: Temperature: -10 C... 70 C Max. permissible relative humidity: 95 %, non-condensing (DIN IEC 60068-2-30) 7

Assembly and installation 3 Assembly and installation NOTICE! The installation must only be carried out by technically trained personnel. When assembling and installing this device, observe the instructions in the operating instructions "Multichannel measuring and control system DULCOMARIN II Swimming Pool Controller and Disinfection Controller DXCa Part 1: Assembly and installation". Make the CAN connection according to the "Multi-channel measuring and control system operating instructions DULCOMARIN II Swimming Pool Controller and Disinfection Controller DXCa Part 1, Assembly and Installation". Terminal allocation Description Terminal identifier Terminal no. Pol Function Alarm relay P1 1 Alarm horn (control) 2 3 Power relay 1 P2 4 PWM ph-lowerer (control solenoid 5 valve DULCO flex) PWM ph-raiser (control) Power relay 2 P3 6 free 7 PWM chlorine PWM ORP PWM alkaline PWM acid Backwashing Power relay 3 P4 8 UV system enable 9 PWM chlorine (control) PWM ORP (control) Heating enable Power supply X1 10 PE 11 N 12 L(1) 8

Assembly and installation A0480 Fig. 1: Terminal Wiring Diagram I. Power relay II. Fuse 0.63 A, slow-acting III. IV. Supply Voltage Alarm (horn) Power supply module Locate the power supply module in the CAN bus backbone (DUL COMARIN II DULCO-Net) The central unit always contains a power supply module. Number of pools Additional N- or P-modules Number of pools Additional N- or P-modules 1-9 4 2-10 5 3 1 11 5 4 2 12 6 5 2 13 6 6 3 14 7 7 3 15 7 8 4 16 8 (Exception: number of pools = 2) 9

Assembly and installation The two LEDS (LED 1 and LED 2) indicate the load of the 24V power supply for the CAN bus. Flash code LEDs power supply monitoring DULCOMARIN II (N and P module) Operating status LED 1 LED 2 Power Remarks (H2, power) (H3, power) Normal off green < 1.1 A All OK Limit load red off > 1.1 A Insert another power supply module into the loop Overload / short circuit red, flashing off > 1.35 A Check wiring 3.1 Repairs (fuse change only) WARNING! Mains voltage Possible consequence: Fatal or very serious injuries. External fuse necessary. If mains voltage is connected to the device, then the fuse carrier is also under mains voltage. Before working on the device, disconnect the device from the mains voltage and secure to prevent switching back on. NOTICE! The fuse only may be replaced by technically trained personnel. All other repair work may only be carried out by Customer Service. Otherwise, general safety regulations apply. Use only original fuses: Micro fuse 5 x 20 mm, 630 ma, 250 V, slow-acting (Order No. 712030). 10

Assembly and installation 3.2 Arrangement of LEDs A0481 Fig. 2: Arrangement of LEDs 11

Assembly and installation 3.3 Example for connection of a solenoid valve WARNING! External fuse necessary Example for connection of a solenoid valve (or hose pump DULCO flex DF2a or alpha motor-driven metering pump). A0482 Fig. 3: Example for connection of a solenoid valve I. Fuse 0.63 A, slow-acting II. Mains connection 12

Technical data 4 Technical data Electrical data The DXMaP power supply module with relay contains the 24 V DC, 1 A direct current power supply unit. Power relay for alarm output (P1): Type of contact: Changeover contact with interference-suppressed varistors Load capacity: 250 V AC, 3 A max., 700 VA Contact lifespan: > 10 5 switching operations (at 3 A) Power relay output for control variable output or limit value reporting (P2 - P4): Type of contact: N/O contact with varistors, interference-suppressed Load capacity: 250 V AC, 3 A max., 700 VA Contact lifespan: > 20 x 10 6 switching operations Nominal voltage (X1): 90-253 V AC (50 / 60 Hz) Maximum power consumption: 500 ma at 90 V AC // 180 ma at 253 V AC Internal fusing with: Micro fuse 5 x 20 mm, 630 ma, 250 V, slow-acting Electrical power consumption: 30 W Degree of protection: IP 20 Ambient conditions: Storage temperature: -10...70 C 13