EA500 EN Installation Instructions Transponder
EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the central console and the many receivers and alert units throughout the protected area. In addition to its communications functions, this transponder also supplies power to the receivers. Each transponder also includes drivers for a single strobe and siren. 2.0 Specifications Table 1: Specifications 3.0 Mounting Normally, the enclosures are mounted first and all wiring is run. Then the electronics are mounted, wired, and tested. The enclosures include hardware for mounting the enclosure to a wall and mounting the circuit board to the enclosure. 1. Mount the enclosure to the mounting surface. 2. Mount the circuit board to the enclosure. See Figure 1. Figure 1: Enclosure Enclosure (AE3) (H x W x D) Temperature Range Power Power Output Driver Outputs Battery Backup Multiplex Buses Communications Interface Keyswitch Input Compatibility Tamper Switch (option) 52.7 cm x 38.1 cm x 10.8 cm (20.75 in. x 15 in. x.25 in.) -0 C to 65 C (-0 F to 19 F) 18.0 VAC, 50 VA maximum plug-in transformer for 110 V, 60 Hz 9 VDC used for SE85 or Proxim radio power Strobe: 500 ma solid state sink, terminal switches to ground in an alarm condition. Siren: 500 ma solid state sink, terminal switches to ground in an alarm condition. 12 VDC lead acid battery Eight multiplex drivers, each capable of driving eight receivers or alert units for a combined total of 6 receivers and alert units per transponder. Selectable SE85 or RS-232 7k EOL resistor, supervised loop ROM version.00 or greater (the version shipped with this unit) is compatible with 30 equipment (such as EA102A-30). Version.00 or greater is not compatible with non 30 equipment. ROM versions earlier than.00 are compatible with non -30 equipment. P/N: CTS1-70, Normally Closed 5 1 - View to show retainer tabs. Insert board between tabs to secure. 2 - Circuit location 3 - Tamper switch mounting location - Support post 5 - Battery location 6 - Enclosure 7 - Circuit board 8 - Support post assembly 8 6 7 1 2 3
EA500 Installation Instructions.0 Wiring EN 3.0 Wiring Figure 2: Wiring Wire the transponder according to Figure 2. The wiring to the receivers and alert units can be as home-run (individual), daisy-chain (device to device), or a combination of both. T-tapping is also acceptable. The recommended cable is -conductor, 18 AWG (1.2 mm [0.05 in.]) fire rated. Wiring from SE85 to the transponders can be home-run (individual), daisy-chain (device to device), or a combination of both. T-Tapping is also acceptable. The recommended cable is -conductor, twisted pair, non-shielded, 22 AWG (0.8 mm [0.03 in.]). 5 2 3 BUS POWER BUS POWER 1 BUS 0 PWR 0 - TX GND - RX 6 1 - Transponder 2 - Typical receiver 3 - Typical output module - To next device 5 - SE85 6 - To next transponder
EA500 Installation Instructions 5.0 Setting the Address EN 5.0 Setting the Address Every transponder in the system must have its own address. Set the address on the transponder using the DIP switches located in the upper-right corner (see Figure 3). Figure shows to set the DIP switches for each possible address. Figure 3: Transponder 1 13 1 12 2 - TX 11 3 GND - RX OFF ON 10 9 Bus 0 Bus 1 Bus 2 Bus 3 Bus Bus 5 Bus 6 Bus 7 8 7 5 AC AC EARTH BUS 0 PWR 0 BUS 1 PWR 1BUS 2 PWR 2BUS 3 PWR 3BUS PWR BUS 5 PWR 5BUS 6 PWR 6BUS 7 PWR 7 GROUND 6 1 - RS-232 port 2 - Select RS-232/SE85 3 - SE85 - Bus enable (0 to 7) 5 - Bus power bar (0 to 7) 6 - Transformer 7 - AC power LED 8-18 VAC input power 9 - Power switch (Do not disconnect AC input power.) 10 - Battery 11-12 VDC battery connector 12 - Transponder address 13-9 V radio power; keyswitch; tamper; strobe (12 VDC, 0.5 A current sink); alert siren (12 VDC, 0.5 A current sink) 1 - Bus 0 = Comm fail; Bus 1 = Carrier detect; Bus 2 = Transmit data; Bus 3 = Receive data; Bus = CRC error; Bus 5 = Test in progress; Bus 6 = Alarm in progress; Bus 7 = Heartbeat
EA500 Installation Instructions 5.0 Setting the Address EN 5 Figure : DIP Switch Settings ON O n OFF 1 2 3 5 6 7 8 1 2 3 5 6 7 8 1 2 3 5 6 7 8 1 2 3 5 6 7 8 1 2 3 5 6 7 8 1 2 3 5 6 7 8 1 2 3 5 6 7 8 1 2 3 5 6 7 8 32 6 96 128 160 192 22 1 2 3 5 6 7 8 9 10 11 12 13 1 15 16 17 18 19 20 21 22 23 2 25 26 27 28 29 30 31 33 3 35 36 37 38 39 0 1 2 3 5 6 7 8 9 50 51 52 53 5 55 56 57 58 59 60 61 62 63 65 66 67 68 69 70 71 72 73 7 75 76 77 78 79 80 81 82 83 8 85 86 87 88 89 90 91 92 93 9 95 97 98 99 100 101 102 103 10 105 106 107 108 109 110 111 112 113 11 115 116 117 118 119 120 121 122 123 12 125 126 127 129 130 131 132 133 13 135 136 137 138 139 10 11 12 13 1 15 16 17 18 19 150 151 152 153 15 155 156 157 158 159 161 162 163 16 165 166 167 168 169 170 171 172 173 17 175 176 177 178 179 180 181 182 183 18 185 186 187 188 189 190 191 193 19 195 196 197 198 199 200 201 202 203 20 205 206 207 208 209 210 211 212 213 21 215 216 217 218 219 220 221 222 223 225 226 227 228 229 230 231 232 233 23 235 236 237 238 239 20 21 22 23 2 25 26 27 28 29 250 251 252 253 25 255
EA500 Installation Instructions Notes: EN 6 Notes:
EA500 Installation Instructions Notes: EN 7 Notes:
Bosch Security Systems 130 Perinton Parkway Fairport, NY 150-9199 USA www.boschsecurity.us Customer Service: (800) 289-0096 Technical Support: (888) 886-6189 2003 Bosch Security Systems Subject to change Printed in the USA 33829E