EA500. Installation Instructions Transponder

Similar documents
MTGW. Installation Guide. CAN-RS-485 BUS Gateway

Control Panels B5512/B4512. en UL Installation Instructions

The Programmable 4-Way Relay Card is an optional peripheral unit that provides four individually programmable relay output circuits.

Quick Start Installation Guide

CDN502 HIGH DENSITY I/O ADAPTER USER GUIDE

ICP-SDI Installation Instructions. SDI Splitter

Connecting a Cisco Input Module

Suprex RS-485 SPX-7500 Wired Reader-Extender

Connecting a Cisco Output Module

CDN503 HIGH DENSITY I/O ADAPTER USER GUIDE

Product Data Sheet. BMS/Graphics Interface. Features

Conettix ITS-D6686-INTL

Conettix ITS-D6686-UL PRELIMINARY. Installation Guide. Ethernet Network Adapter

Conettix ITS-D6686-UL

FPA-1000-V2 Network Cards FPE-1000-NE, FPE-1000-NF, and FPE-1000-NW

Connecting a Cisco Reader Module

Conettix D6680. Installation Instructions. Ethernet Network Adapter

PRO3200 Professional Modular Access Control Hardware

TCNM-ACBB1 Installation Manual

TAC I/NETTM 1284, 1280, Security Control Unit

Product Data Sheet. Hochiki 8 Way I/O Card. Features

UC-2000 Installation Manual Unicorn Computers Technology Limited

Quick Start Installation Guide

VertX. V100, V200 and V300. Installation Guide Barranca Parkway Irvine, CA USA. November Rev A.1

Installation Instructions for UL Rev A

TS0867 Four-Door & TS0869 Four-Lift Controller Installation Manual

PRO2200 Professional Modular Access Control Hardware

Installing Sentor. Hardware Installation

1 Description. 2 Specifications. Product Installation Document. Honeywell 12 Clintonville Road Northford, CT

GRX-CI-RS232 Control Interface

CA-A480-A Elevator Controller. Reference & Installation Manual

Andover ContinuumTM Infinet II

High Level Lift Protocol Controller Model TS0868

D1265. Installation Guide. Touchscreen Keypad

OMX-CI-RS232 Control Interface

PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY

Security Management System by Diebold, Inc. LINX System Hardware Installation Guide

SuperBus Hardwire Input Module (HIM) Document Number: Rev. C September 1998

P522 Signal Processor

Suprex Fiber Optic. Reader-Extender SPX-7400 SPX Product Manual. Reader-Extender. Manual. SPX-7400 Series EXP Suprex_FiberOptic_MAN_170502

Integriti 8-32 Zone LAN Expander Module Kit INSTALLATION MANUAL

istar Pro Installation Guide

SPX-7400_SPX-7410_MAN_161028

2100-IS RS232 to RS422\485 Converter.

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

TB21. NO - Relay. Relay. Common - Relay. NC - Relay. Input J23. Ground TB22 TB23. NO - Relay Common - Relay NC - Relay Input Ground.

NETWORK CONCENTRATOR LINK. This equipment must only be installed and serviced by professional qualified personnel.

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Accessory Packages for the Allegiant

Wiring Guide EP.HIO. Version 1.03 Last Updated:

MC CO MODBUS ADDRESSABLE SENSOR

4100/4120-Series Class A / Class B Zone Modules Installation Instructions

Hardware Installation

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

POWERWISE INDAC SETUP MANUAL

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

NPort 6600 Series Quick Installation Guide

AC-215x-B Series 2-Reader Networked Access Control Panel Hardware Installation and User Manual. Models: AC-215-Bx AC-215-DIN AC-215IP-Bx AC-215IP-DIN

16-Way Input 48-Way Output Card

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

PGR-6101 MANUAL GROUND-FAULT & INSULATION MONITOR

UNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN

AC-225x-B Series. Expandable 2-Reader Networked Access Control Panel Hardware Installation Manual. Models:

Open Processor with Square D Driver

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Quick Start Installation Guide

Rev CH Breaker Gateway Installation and Operation Manual

CI-1 and CI-8. Communications Interface Betsy Ross Drive Santa Clara, CA (408) FAX (408) P/N Rev.

Model: EP.L3800. Wiring Guide EP.L3800. Version 1.03 Last Updated:

SmartLock Controller INSTALLATION MANUAL

Andover ContinuumTM Infinet II

DX4020. Installation Guide. Network Interface Module

Installation Manual CCL 20 D PTZ camera controller unit DIN-rail mounting

N-1000-II. Installation & Programming Manual. Version rev. 2.0

ACS-30-EU-MONI-RMM2-E

SPX-5000 Series. Operations Manual. Suprex Reader Extender - RF Wireless Interface. RPT GHz Repeater. SPX GHz

CTR21, CTR22, CTR23, and CTR24 Wall Modules

Size of Mounting Plate /2 inches High x 7 inches Wide x 3 1/16 inches Deep (includes circuit boards)

RTU560 Connections and Settings DIN Rail RTU 560CIG10


PACSystems RX7i IC698CHS009/119

BCM2 Series Branch Circuit Monitors Quick Setup Guide

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

Installing the DX LCD Display

TruPortal Dual Door Interface Module Quick Reference

PGR-3200 MANUAL INSULATION MONITOR

MR52 READER INTERFACE

QSE-CI-DMX Control Interface

IntesisBox Modbus Server KNX

CS485. User s Manual. Version ZYPEX, Inc.

DIN-RAIL EXPANDER int-iors_en 10/14

Intrusion Control Panels Quick Guide. May 2015

SEC-H-201 Security Controller

FEATURES DESCRIPTION MODEL 110B. Power Supply

AUTROFIELDBUS PROTOCOL CONVERTER BSD-321/1

GX-Series Control Panel

SPX-7400 Series. Operations Manual. Suprex Reader Extender - Fiber Optic Interface. SPX-7400 shown with EXP-2000 SPX-7400_MAN_082112

PM Series Power Meter

User s Manual Pulse Encoder Interface Module OTAC-01

Transcription:

EA500 EN Installation Instructions Transponder

EA500 Installation Instructions 1.0 Overview EN 2 1.0 Overview The EA500 Transponder is the Security Escort module that provides communications between the central console and the many receivers and alert units throughout the protected area. In addition to its communications functions, this transponder also supplies power to the receivers. Each transponder also includes drivers for a single strobe and siren. 2.0 Specifications Table 1: Specifications 3.0 Mounting Normally, the enclosures are mounted first and all wiring is run. Then the electronics are mounted, wired, and tested. The enclosures include hardware for mounting the enclosure to a wall and mounting the circuit board to the enclosure. 1. Mount the enclosure to the mounting surface. 2. Mount the circuit board to the enclosure. See Figure 1. Figure 1: Enclosure Enclosure (AE3) (H x W x D) Temperature Range Power Power Output Driver Outputs Battery Backup Multiplex Buses Communications Interface Keyswitch Input Compatibility Tamper Switch (option) 52.7 cm x 38.1 cm x 10.8 cm (20.75 in. x 15 in. x.25 in.) -0 C to 65 C (-0 F to 19 F) 18.0 VAC, 50 VA maximum plug-in transformer for 110 V, 60 Hz 9 VDC used for SE85 or Proxim radio power Strobe: 500 ma solid state sink, terminal switches to ground in an alarm condition. Siren: 500 ma solid state sink, terminal switches to ground in an alarm condition. 12 VDC lead acid battery Eight multiplex drivers, each capable of driving eight receivers or alert units for a combined total of 6 receivers and alert units per transponder. Selectable SE85 or RS-232 7k EOL resistor, supervised loop ROM version.00 or greater (the version shipped with this unit) is compatible with 30 equipment (such as EA102A-30). Version.00 or greater is not compatible with non 30 equipment. ROM versions earlier than.00 are compatible with non -30 equipment. P/N: CTS1-70, Normally Closed 5 1 - View to show retainer tabs. Insert board between tabs to secure. 2 - Circuit location 3 - Tamper switch mounting location - Support post 5 - Battery location 6 - Enclosure 7 - Circuit board 8 - Support post assembly 8 6 7 1 2 3

EA500 Installation Instructions.0 Wiring EN 3.0 Wiring Figure 2: Wiring Wire the transponder according to Figure 2. The wiring to the receivers and alert units can be as home-run (individual), daisy-chain (device to device), or a combination of both. T-tapping is also acceptable. The recommended cable is -conductor, 18 AWG (1.2 mm [0.05 in.]) fire rated. Wiring from SE85 to the transponders can be home-run (individual), daisy-chain (device to device), or a combination of both. T-Tapping is also acceptable. The recommended cable is -conductor, twisted pair, non-shielded, 22 AWG (0.8 mm [0.03 in.]). 5 2 3 BUS POWER BUS POWER 1 BUS 0 PWR 0 - TX GND - RX 6 1 - Transponder 2 - Typical receiver 3 - Typical output module - To next device 5 - SE85 6 - To next transponder

EA500 Installation Instructions 5.0 Setting the Address EN 5.0 Setting the Address Every transponder in the system must have its own address. Set the address on the transponder using the DIP switches located in the upper-right corner (see Figure 3). Figure shows to set the DIP switches for each possible address. Figure 3: Transponder 1 13 1 12 2 - TX 11 3 GND - RX OFF ON 10 9 Bus 0 Bus 1 Bus 2 Bus 3 Bus Bus 5 Bus 6 Bus 7 8 7 5 AC AC EARTH BUS 0 PWR 0 BUS 1 PWR 1BUS 2 PWR 2BUS 3 PWR 3BUS PWR BUS 5 PWR 5BUS 6 PWR 6BUS 7 PWR 7 GROUND 6 1 - RS-232 port 2 - Select RS-232/SE85 3 - SE85 - Bus enable (0 to 7) 5 - Bus power bar (0 to 7) 6 - Transformer 7 - AC power LED 8-18 VAC input power 9 - Power switch (Do not disconnect AC input power.) 10 - Battery 11-12 VDC battery connector 12 - Transponder address 13-9 V radio power; keyswitch; tamper; strobe (12 VDC, 0.5 A current sink); alert siren (12 VDC, 0.5 A current sink) 1 - Bus 0 = Comm fail; Bus 1 = Carrier detect; Bus 2 = Transmit data; Bus 3 = Receive data; Bus = CRC error; Bus 5 = Test in progress; Bus 6 = Alarm in progress; Bus 7 = Heartbeat

EA500 Installation Instructions 5.0 Setting the Address EN 5 Figure : DIP Switch Settings ON O n OFF 1 2 3 5 6 7 8 1 2 3 5 6 7 8 1 2 3 5 6 7 8 1 2 3 5 6 7 8 1 2 3 5 6 7 8 1 2 3 5 6 7 8 1 2 3 5 6 7 8 1 2 3 5 6 7 8 32 6 96 128 160 192 22 1 2 3 5 6 7 8 9 10 11 12 13 1 15 16 17 18 19 20 21 22 23 2 25 26 27 28 29 30 31 33 3 35 36 37 38 39 0 1 2 3 5 6 7 8 9 50 51 52 53 5 55 56 57 58 59 60 61 62 63 65 66 67 68 69 70 71 72 73 7 75 76 77 78 79 80 81 82 83 8 85 86 87 88 89 90 91 92 93 9 95 97 98 99 100 101 102 103 10 105 106 107 108 109 110 111 112 113 11 115 116 117 118 119 120 121 122 123 12 125 126 127 129 130 131 132 133 13 135 136 137 138 139 10 11 12 13 1 15 16 17 18 19 150 151 152 153 15 155 156 157 158 159 161 162 163 16 165 166 167 168 169 170 171 172 173 17 175 176 177 178 179 180 181 182 183 18 185 186 187 188 189 190 191 193 19 195 196 197 198 199 200 201 202 203 20 205 206 207 208 209 210 211 212 213 21 215 216 217 218 219 220 221 222 223 225 226 227 228 229 230 231 232 233 23 235 236 237 238 239 20 21 22 23 2 25 26 27 28 29 250 251 252 253 25 255

EA500 Installation Instructions Notes: EN 6 Notes:

EA500 Installation Instructions Notes: EN 7 Notes:

Bosch Security Systems 130 Perinton Parkway Fairport, NY 150-9199 USA www.boschsecurity.us Customer Service: (800) 289-0096 Technical Support: (888) 886-6189 2003 Bosch Security Systems Subject to change Printed in the USA 33829E