Terragraph Installation Guide. March 8, 2017 Version 0.3

Similar documents
BreezeMAX Wi² and BreezeACCESS Wi² Quick Installation Guide

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

Satellite INSTALLATION GUIDE

33.6W Power over Ethernet Waterproof Adapter PoE Plus Single Port Injector for Outdoor Application

TRC-190 User s Manual

XBR V4 INSTALLATION AND USER GUIDE

INJ-24A Series Quick Installation Guide

INSTALL INSTRUCTIONS RSXMR-9886-P-48

R2 Extender. Quick Installation Guide

Dome Camera. Hardware Manual Z81, Z /01/08

Quick Installation Guide

TRC-190 User s Manual

IIM Warwick Court. Williamsburg VA REV 5

D-Link Switch User Manual. Table of Contents

Installing the Camera

Broadband Automatic Disconnect Switch. User Manual

4 10/100/1000T Mini-GBIC with 4 IEEE 802.3at High Power PoE Industrial Wide Temperature Switch. User Manual SISTP LRT

Model#: IN-DO3MIRF 3MP Outdoor Dome with True Day/Night, IR, Basic WDR, Fixed lens

Next Generation Firewall

IMC-21 Quick Installation Guide

INSTRUCTION MANUAL DISTRIBUTION UNIT. Please read this manual thoroughly before use, and keep it handy for future reference.

InnoMedia Business VoIP ATA Models

IMC-21GA Quick Installation Guide

User Guide CPSMP VAC Power Supply Module: PointSystem CPSMC Accessory CPSMC Accessory. Contents.

MC 11 EB-2 Power supply cabinet with external bus, AC version

Sarix Professional IMP Series 3.75 Indoor Dome. Quick Start Guide IMP121-1IS IMP221-1IS IMP321-1IS IMP521-1IS C2291M-B-EN (12/16)

10/100/1000T to Mini-GBIC Industrial Switch Converter 10/100/1000T to 1000SX/LX Industrial Switch Converter. AMG9011G-H (-40 to 75C) User Manual

Installation Guide for America Solar Wholesale Photovoltaic Modules

Next Gen Sarix Enhanced IBE Series Bullet Cameras

LED Maintenance Instructions

R1 Extender. Quick Installation Guide

Quick Start Guide. C-100 Series Switches

DC-D4213RX DC-D4213WRX

R2 BaseStation. Quick Installation Guide

Outdoor PTZ. Mounting on the Ceiling Using Pendant Mount. Installation Guide. For Models: I93, I94, I95, I96, KCM /12/03

M215 (M215-60) Safety

Installation Job Aid for VSP 4850GTS

RMB Peripheral Units Installation Guide

Ruckus Wireless ZoneFlex 7762 Dual Band n Outdoor Access Point. Installation Guide

DVI Extender over Single CAT5 Model #: DVI-C5-M-SET

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Laser Light Projector User s Manual Shenzhen Optlaser Technologies Co., Ltd Model: AL-RG130-RM1

8-port 10/100TX + 2-Port 10/100/1000T/100/1000 SFP Combo with 8 PoE Injectors Industrial Ethernet Switch User Manual

FDS / FDS-R / FDS-PS

IMC-21A Quick Installation Guide

Installation RA5112-C-16A-C20. Basic Rack Power Distribution Unit

Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules

AlphaGateway SMG-01PE Quick Start Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Perle MCR200 Installation Guide

Installation Job Aid for VSP 4450GTX-HT- PWR+

MOXA EtherDevice Switch & PoE Splitter

Neets Switching Relay - 2. Installation manual

DISCLAIMER Whilst every effort has been made

M5 and M10 Routers Power Supply and Power Cord Component Replacement Instructions

Under the Table Interconnect Solutions

XBR V3 INSTALLATION AND USER GUIDE Rev 03. xbr V3 Installation and User Guide Page 1 of 14. (preliminary)

Installation Job Aid for Ethernet Routing Switch 3600 Series

Removal and Installation8

Lantech. IPGS-0204DSFP 4 10/100/1000T PoE at/af + 2 Dual Speed SFP Industrial Unmanaged Switch

EZ Switch EZ Connect N SMCFS1601/SMCFS2401

ALTAI C1N SUPER WIFI CPE INSTALLATION GUIDE. Version 1.0 Date: September, Altai Technologies Ltd. All rights reserved

SUN KTL-USH0 Quick Guide. Issue: 01 Part Number: Date: HUAWEI TECHNOLOGIES CO., LTD.

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

IntelliLED TM. Controls: User Guide. Picture for DALI only. Wireless adds external antenna. NOTE: These parts are NOT user serviceable

PAR+ & MSC+ Controller. Installation Manual

OPTRON mobile. User Guide. magnified vision. Vers. 2.1AL Magnified Vision, Inc. 2013

RS-422/485 to Fiber Industrial Converter

3-Phase, Dual-Input 6-Slot Power Supply System STARTUP GUIDE

EDS-G205A-4PoE Hardware Installation Guide

hdpv.org Ampt Communications Unit Installation Manual D

Replacing the Power Supply

Clipsal Bus Couplers. Two Channel (SLC5102BCLEDL) and Four Channel (SLC5104BCL) for Use with C-Bus Wired Systems

QUICK START GUIDE FOR THE TRANZEO WIRELESS TR-CPE90

Quick Installation Guide

PTC-101-M12 Hardware Installation Guide

The power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.

Ruckus Wireless ZoneFlex g Outdoor Access Point. Getting Started Guide. Part Number (Revision B) Published October 2009

M215-Z Safety Information (M LL-IG-ZC)

Altivar 61/71 Adjustable Speed Drives Heatsink Fan Kits VZ3V1212 and VZ3V1216

PowerLogic ION7300 Series

INSTALLATION INSTRUCTIONS FOR THE BV10-100/1000

Remote RMM-1400 Intelligent Remote Site Management Device. Installation Guide

Installation Notes TII Model 341 Protector

E1135C PDU and Pod Upgrade Procedure

M250 (M LL) Safety

Installation/User Manual

Power Supply Installation

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Manual. Network Expansion Port 2 NEP-2. English. Brands by Navico - Leader in Marine Electronics

Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.

PV Rapid Shutdown device

For More Product Information On This Other Arcade and Amusment Products, Visit :

Model 2380 Rack-Mount Kit

onlinecomponents.com

User Manual TL-DA14-HD2 1x4 HDMI Splitter & Distribution Amplifier All Rights Reserved Version: TL-DA14-HD2_160926

Serial No. OWNER S MANUAL. Installation & Operation

Nature Power Inverters. Modified Sinewave 1000w/1500w True Sinewave 1000w/2000w. Owner s Manual

Principal LED Street Stik Fluorescent Bulb Replacements

OSRAM ReliaSys TM D15 LED Retrofit Kit INSTALLATION GUIDE

Transcription:

Terragraph Installation Guide March 8, 2017 Version 0.3

Warnings WARNING: Shock Hazard. May result in serious injury or death. Turn off circuit power at circuit breaker or disconnect power at source receptacle before installing unit. WARNING: Only trained and qualified personnel should be allowed to install, replace, or service this equipment. WARNING: Installation of this equipment must comply with local and national electrical and building codes. WARNING: Fall Hazard. When working at height, observe safe practices and use a suitably-attached safety harness. WARNING: Installing the DC power with reversed polarity may result in completely and permanently destroying the Terragraph primary radio. Compliance This device complies with Part 15 rules. Operation is subject to the following two conditions: 1. This device may not cause harmful interference, and 2. This device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for Class A digital devices, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. To minimize interference a Ferrite bead (Manufacture: Steward, Part number: 25A2029) needs to be installed on the input DC power cable. This device contains transmitter module FCC ID: 2AK7S-FBC1701 RF Exposure: This device has been evaluated or RF exposure for Human in reference to ANSI C95.1 (American National Standards Institute) limits. The evaluation was based on ANSI C95.1. At least 37cm of separation distance between this device and the user s body must be maintained at all times. Any changes or modification to the product not approved by FCL Tech could void the user s authority to operate this device. 2

Package Contents For Primary Sectors: N G C E M A D J H B F L K Key Part Description Part Number Quantity A Terragraph primary sector BLY-236-000005 1 B Terragraph mounting bracket BLY-213-000013 1 C Stainless steel M6x1, 12mm mounting bolts BLY-213-000027 5 D Stainless steel washers BLY-213-000041 5 E M25 dome cap BLY-207-000251 2 F Power connector terminal block BLY-244-000067 1 G 1x1 USB inter-sector cable BLY-207-000238 1 H 1x2 USB inter-sector cable BLY-207-000237 1 I 1x3 USB inter-sector cable BLY-207-000236 1 J Intersector Port Plug BLY-213-000039 1 K M25 Cable Gland BLY-207-000250 3 L Power Cable Gland Grommet BLY-207-000253 1 M Ethernet/Fiber Cable Gland Grommet BLY-207-000252 2 N Stainless steel Band Clamp BLY-213-000048 2 I Primary Sector Ports Ethernet Port Power Port Inter-sector Port Fiber Port 3

Package Contents For Secondary Sectors: C D E F A B H G Key Part Description Part Number Quantity A Terragraph secondary sector BLY-236-000003 1 B Terragraph mounting bracket BLY-213-000013 1 C Stainless steel M6x1, 12mm mounting bolts BLY-213-000027 5 D Stainless steel washers BLY-213-000041 5 E M25 dome cap BLY-207-000251 2 F Ethernet/Fiber Cable Gland Grommet BLY-207-000252 1 G M25 Cable Cland BLY-207-000250 1 H Stainless Steel Band Clamp BLY-213-000048 2 Secondary Sector Ports Ethernet Port Inter-sector Port 4

Materials Required (customer supplied) 6-10AWG grounding wire and lugs appropriate to local codes, Recommended lug: Burndy YAZ8CTC14 48 Volt or 54 Volt DC power supply capable of supplying 2.5A, Recommended power supply: Mean Well HEP-185-48 Terminal Ground Bar with at least 6 terminals which support 6-10AWG grounding wire and can be secured to Primary radio with M6 bolt, Recommended ground bar: Schneider PK9GTACP Ferrite Bead for electromagnetic interference filtering (EMI), Recommended ferrite bead: Steward 25A2029 Electrical wire conforming to local codes Any additional electrical materials necessary to conform to local codes Outdoor rate Cat5e or Cat6a J-45 Ethernet cable conforming to local codes Outdoor rated 2-strand multi-mode or single mode armored fiber patch cord with LC connector to match SFP module UV rated plastic cable ties or stainless steel cable ties for securing cables SFP or SPF+ Module. See table below: SFP Type Speed Range Wavelength Multi Mode SFP 1Gbps Upto 300M 1310, 1550nm Single Mod SFP 1Gbps Upto 10KM 850nm Singe Mode SFP+ 10Gbps Upto 300M 1310, 1550nm Multi Mode SFP+ 10Gbps Upto 10KM 850nm Tools Required (customer supplied) Required Terragraph technician kit/aiming tool 10mm combination or socket wrench Electricians wire cutter/stripper Needle nose pliers Channellock for removal of cable glands 8mm nutdriver or cordless drill with 8mm socket (for band clamps) Crimping tool for RJ-45 connector Crimping tool for grounding lugs Flat blade screw driver Recommended Personal Safety Protection (Safety glasses, Hard Hat, Work Gloves, Safety harness) Flashlight Digital multimeter RJ-45 tester with POE tester Fiber tester Level for plumbing mounting pipe 5

Installation Steps Terragraph Brackets Mounting Locations Installation on pipe on luminaire arm. Installation directly on signal arm. Installation directly on shaft. Mountinging location should be a pole or pipe at least 45mm (1.75 ) outside diameter. The pipe may be vertical ±5 or horizontal ±30. 1. Install brackets for all the Terragraph sectors at this location. Supplied band clamps support a pole diameter between 45mm-63.5mm (1.75-2.5 ). Note that band clamps can be interleaved as shown for a compact installation. 2. If mounting on a short length of pipe, you may install the brackets to the pipe first, then mount the pipe at the target location for convenience. 3. Horizontally center each of the brackets using the built-in bubble levels. 6

Using the Aiming Tool 1. Place the Terragraph aiming tool on each of the brackets. 2. Adjust the azimuth, then the elevation, until the target location on the opposite side of the link appears in the center of the crosshairs of the aiming tool. 3. Remove the tool and carefully store the aiming tool in its case when finished. Mounting the Terragraph Sectors 1. Mount the Terragraph sectors according to the site plan. We recommend that you install the primary sector at the position which has the most convenient access to the back and bottom of the unit. 2. Tighten the four nuts securely to the mounting bracket but do not over-tighten. 3. If specified in the site plan, use the tethering loop (built into on the fins on the back of the unit) to secure each sector with a safety cable or wire. 7

Installing the Inter-sector Cable Installation of Inter-sector Cable 1. Select the inter-sector cable for the number of sectors you will install to the primary. 2. Remove the label covering the inter-sector opening. 3. Plug the the inter-sector cable into the USB connectors. Primary units will use the larger end of the intersector cable for locations using the 1x2 and 1x3 inter-sector cables. 4. Slide the grommet toward the USB connectors until it fits over the inter-sector opening and then push the rubber grommet into opening in the Terragraph radio. The intersector cable has a groove which needs to fit into the lip of the inter-sector opening. It is recommended to use a flat blade screw driver to gently push the inter-sector cable s groove into the lip of the inter-sector opening. 5. Repeat steps 2-4 to install the other end of the inter-sector cable to the secondary sectors. 6. If there are no secondary sectors, secure the inter-sector opening with the inter-sector grommet. Removal of Inter-sector Cable 1. Push one side of the grommet into the inter-sector hole using a flat blade screw driver. 2. Rotate the grommet so it can be rotated sideways. 3. With a pair of needle nose pliers pull the grommet outside of the inter-sector hole and disconnect the intersector connector from the USB connectors. Installing Fiber 1. If fiber will be installed at this location, plug the SFP+ module into the fiber patch cord connector and place all the parts of the cable gland over this fiber cable. Recommendations: - All fiber used outside should be armored or protected in conduit. - Test the fiber to the switch or transceiver before the install. 2. Remove the protective label from the SFP opening of the primary sector. 3. Push the SFP+ module up into the SFP+ cage until connected and well seated. 4. Screw the cable gland into the thread of the primary sector and tighten hand-tight. 5. Turn an additional 1/4 turn using a large open-ended or adjustable wrench. 6. Assemble the rest of the cable gland and tighten hand-tight. 7. If no fiber will be installed, remove the label and replace with an M25 dome cap. CAUTION: Make sure that you form a 80mm - 130mm (3-5 ) drip loop in each cable that slopes downwards into any cable gland or building penetration. This will prevent water from running along the cable and entering the enclosure or building where the cable terminates. 8

Installing Ethernet Access Device 1. If an Ethernet access device will be installed at this location, mount the device according to the manufacturer s instructions. 2. Route the Ethernet cable from the acess device to the Terragraph radio appropriately. 3. Pass the Ethernet cable through the cable gland and crimp the RJ-45 connector if necessary. 4. Test the cable. 5. Remove the protective label from the Ethernet opening on the primary sector. 6. Insert the cable into the cable gland and plug in the RJ-45 connector. 7. Screw the cable gland into the thread of the primary sector and tighten hand-tight. 8. Assemble the rest of the cable gland and tighten hand-tight. Ensure the rubber grommet for the cable gland is oriented in the correct direction (rubber grommet is labeled with either inside or outside). 9. If no Ethernet will be installed, remove the protective label and replace with an M25 dome cap. CAUTION: Make sure that you form a 80mm - 130mm (3-5 ) drip loop in each cable that slopes downwards into any cable gland or building penetration. This will prevent water from running along the cable and entering the enclosure or building where the cable terminates. Grounding the Terragraph Sectors 1. Connect each of the sectors (and, if appropriate, the access point) to earth ground according to local codes. There is an M6 bolt on the back of each unit designed for grounding using a lug with a 6.5mm (1/4 ) inner diameter center hole. We recommend using a grounding bus bar on the primary sector which can then be used to ground the secondary sectors. This allows the use of just one grounding run to the earth ground. We recommended to use a grounding wire between 6-10AWG, but local codes should dictate grounding requirements. CAUTION: Be sure that grounding is available and that it meets local and national electrical codes. For additional lightning protection, use lightning rods and lightning arrestors. Make sure that proper lightning surge protection precautions are taken according to local electrical codes. 9

Installing the Power Supply - + 1. Install and secure the power supply according to the site plan and local codes. 2. Place the power cable gland over a length of approved wiring (suitable for use between the power supply and the Terragraph primary sector). 3. Using an approved outdoor/waterproof junction box or connector, connect the DC output of the power supply to the power cable leading to the Terragraph primary. 4. Strip the power cable by 10mm (3/8 ) and insert into the terminal block according to the polarity in the figure above. 5. Tighten the terminal block screws very firmly and verify that the wire is well secured. 6. Install the Ferrite bead around the outer cable sheething. Open the bead and place it 5mm (3/16 ) from the end of the DC power supply outer cable sheething on the end which contains the terminal block. Once positioned, close the Ferrite bead which will then snap shut. 7. Remove the protective label from the power opening of the primary sector. 8. Insert the power terminal block into its receptacle. 9. Holding the power cord to ensure it remains connected and well seated, screw the cable gland into the thread of the primary sector and tighten by hand. 10. Assemble the rest of the cable gland and tighten hand-tight. Ensure the rubber grommet for the cable gland is oriented in the correct direction (rubber grommet is labeled with either inside or outside). CAUTION: Make sure that you form a 80mm - 130mm (3-5 ) drip loop in each cable that slopes downwards into any cable gland or building penetration. This will prevent water from running along the cable and entering the enclosure or building where the cable terminates. 10

Basic Troubleshooting Terragraph primary unresponsive: 1. Remove the intersector cable grommet which will allow the power LED to be viewed. 2. Check if the power LED is illuminated. 3. Unscrew the power cable gland. 4. Disconnect the power and remove the power connector for the primary sector. 5. Reconnect the power. 6. If power LED is not illuminated, use a digital multimeter in DC voltage mode to verify there is 48V to 54V DC at the Terragraph power terminal block with the correct polarity. If not, correct the problem. 7. Reseat the power connector and reconnect to primary sector. 8. If LED inside unit does not illuminate even with correct power at the power connect, replace the primary sector. Terragraph secondary unresponsive: 1. Remove the intersector cable grommet which will allow the power LED to be viewed. Make sure you keep the intersector cable connected to the USB port. 2. Check if the power LED is illuminated. 3. Disconnect the inter-sector cable. 4. Reconnect the power. 5. If power LED is not illuminated, use a digital multimeter in DC voltage mode to verify there is 48V to 54V DC between pin1 and pin 5 on the intersector cable connecting to the secondary radio. 6. If there is no DC power on the intersector cable check the cable connection at the primary radio. If this doesn t fix the issue try replacing the intersector cable. If problem persists, replace the primary sector. 7. Reseat the power connector and reconnect to primary sector. 8. If LED inside unit does not illuminate even with correct power at the power connect, replace the secondary sector. Fiber connected to Terragraph, but remote switch/router indicates no link integrity: 1. Verify that the device on the other end of the fiber is powered on and corrctly configured. 2. Use a fiber cable tester to verify that receive light power and (if possible) link integrity for the fiber running to the Terragraph radio. 3. Remove the SFP module, plug the fiber cable into a known good SFP module and reseat firmly. 4. If problem persists, replace the primary sector. Ethernet connected to Terragrpah, but non-poe device indicates no link integrity: 1. Verify that the Ethernet device is powered on and configured. 2. Remove the Ethernet cable from the Terragraph radio and using cable cable verify link integrity between the Ethernet device and a known good laptop. 3. Reconnect Ethernet cable to Terragraph radio. 4. If problem persists, replace the Terragraph radio. Ethernet connected to Terragrpah, but PoE powered device does not power up: 1. Unplug Ethernet cable from the primary sector. 2. Use a PoE tester and a known working Ethernet cable, verify that the Terragraph Ethernet port is providing 48V or 54V DC voltage. If Terragraph primary sector is not supplying correct voltage, replace the primary sector. 1. Reconnect the Ethernet cable to the Terragraph primary sector. 2. Use a cable tester to test POE power at the end of the Ethernet cable connected to the Terragraph primary sector. If needed replace Ethernet cable. 3. Verify the voltage requirements of the POE device 4. If problem persists, try with another PoE powered device. 11

Product Specifications Physical Dimensions (Without Bracket): 168.15mm (W) x 202.70mm (H) x 88.62mm (D) Dimensions (With Bracket): 168.15mm (W) x 227.33mm (H) x 200.66mm (D) Weight: 3.51KG (With Bracket and Glands) Environmental conditions: Operating temperature range: -40 C to +50 C Ingress Protection: IP66 Mounting configurations: Mounting for up to 4 sectors on vertical (±5 ) pipe or pole or 2 sectors on horizontal (±30 ) pipe or pole Bracket freedom of movement: azimuth ±20 and elevation ±25 Power Input Power: 48 volts DC to 54 volts DC nominal with reverse polarity protection PoE Output Power: IEEE 802.3af (15 watts maximum with 48V or 54V power supply) or IEEE 802.3at (25.5 watts maximum with 54V power supply). Power consumption (without POE): 21 watts for primary sector, 19 watts per secondary sector Interfaces Network ports on primary sector: Single 1000BASE-T port Single SFP+ 10Gbps Ethernet module Three 2.5Gbps Ethernet inter-sector connectors Network ports on secondary sector: Single 1000BASE-T port Single 2.5Gbps Ethernet inter-sector connectors Radio Operating Frequency: 57GHz-64GHz* Number of channels: single channel operation out of 3 available* Channel Bandwidth: 2.16GHz EIRP: 43dBm Peak ; 40dBm Average Modulation: BPSK, QPSK, 16 QAM Latency: 667µs per node ; max 10ms for system (15 hops) *Based on local regulatory standards. Certi ications FCC pending. UL listing pending. 12

Support To obtain technical support for the Terragraph product please email terragraph-support@xxxx.xxx 13