Operating Manual LF1-LF4 i

Similar documents
OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Conductive Level Controller

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Conductivity-Panelmeter LF 9648 Conductivity measurement with 2-and 4-electrode cells

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Standstill monitor A / / 2011

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

Operating Instructions. For. Level Control Module. Model SSR 1000

Installation and Operation Manual SPC1

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

Manual Simatek Control Unit GFC 32

I/O module (Expansion module)

Manual Control Unit GFC 32

Part No. Z , IA Jul OPERATION MANUAL. High Voltage Digitalmeter A

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

TPE 1464 Series Pressure Transducer

Technote. Frese OPTIMA Compact actuators DN10-DN32. Application. Features thermic actuators. Features motoric actuators. Approval.

Capacitance level switches LS 210 LS 220

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

JUMO ecotrans Lf 01/02

INSTRUCTIONS FOR MODEL 1000 DIGITAL PROCESS INDICATOR AND ALARM

L Series Humidity/-temperature sensors for use in heating, ventilation and air conditioning Technical data Humidity

Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature with calibration certificates

Part No. Z , IA Mar OPERATION MANUAL. High Voltage Digitalmeter A

Operating instructions. Speed monitor D / / 2014

24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0

Clear Benefits of the KRAL Electronic.

D6030S - D6030D INSTRUCTION MANUAL. D SIL 3 Switch/Proximity Detector Repeater Relay Output. Models D6030S, D6030D

BXD17 Series. Features. Analytical instrumentation for your measurement applications.

GRUNDFOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers. For conductivity measurement (conductive, inductive)

Overview of types. Technical data

SDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)

Operating manual LRD 325. Conductivity measuring cell to be installed in pipelines

Microprocessor Resistivity & Conductivity Monitor/Controller EC410 / EC430. Operation Manual

LC2300 Level Controller Installation and Maintenance Instructions

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

GRUNDFOS ALLDOS DATA BOOKLET. Conex DIS-C. Measuring amplifiers and controllers for conductivity measurement 50/60 Hz

Rhino Buffer Module PSM24-BFM600S. Operating Instructions

KOBOLD TDA Series Digital Temperature Transmitter

Inclinometer. 4-20mA and RS232

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

WSK INTELLIGENT TEMPERATURE AND HUMIDITY CONTROLLER USER MANUAL

14 Pressure Measurement. Measuring Devices Description Pressure range Connection Device Page

Component identification

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

Power Supply, Primary Switch Mode, Narrow Design MINI-PS AC/24DC/1

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

Instruction Sheet Board Style Low Water Cutoff

SSR - Supplies - Relays

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

NEMA 4 Option Card Installation Manual

Operating instructions Evaluation system for flow sensors VS / / 2013

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

E2Q4 Square Proximity Sensor

ICON SERIES IDRIVE. Intelligent Constant Pressure. Water Supply Controller User Manual. idrive

Display and Monitoing Units

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL

V E62B Snap-in I/O Module

LDCL DIGITAL CONTROLLER OPERATING MANUAL

Rhino Redundancy Module PSM24-REM360S. Operating Instructions

Electrical Actuators

PSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description

Installation and Operation Manual DPC1

BMF400 Input/output module

Differential Liquid/Gas Pressure Transmitter

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

LCD LCDS LCDRI CONTROLLER OPERATING MANUAL

HD HD [ GB ] Probes for soil volumetric water content measurement. Temperature. Humidity PART OF G H M GROUP TELEMETRIE & AUTOMATION

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

Electrical Actuators

PRO-1250D CT MID DIN rail three phase four wire energy meter.

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

EMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks

Proportional Control Unit (PCU)

Tempco Instruction Manual

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

CDD4 Duct Carbon Dioxide Transmitter

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

Manual Control Unit GFCD 16

Instruction Sheet PN 51A-6081C/rev.A June Model 6081-C Wireless Contacting Conductivity Transmitter

XTM1250SA DIN rail three phase four wire LCD display energy meter

Classification Enclosure rating Input voltage Type of

KRAL Electronics BEM 300 and BEM 500.

VA-7700 Series. Electric Valve Actuators. Product Bulletin

NIR Moisture Analyzer KB-30

Operating and installation instructions Differential pressure monitor

JUMO MIDAS C08. OEM Pressure Transmitter Basic. Applications. Brief description. Special features. Customer benefits

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Expansion Module HZS 541-1S

GENERAL SAFETY GUIDELINES

Compact universal controllers

External level devices for conductive point level switch

Transcription:

Operating Manual Oct. 2005 Fillerkampsweg 1 5 31832 Springe OT Eldagsen Tel.: 05044/887-0 (Fax: -99) E-Mail: info@iotronic.de Internet: http://www.iotronic.de

Page 3 Contents 1.0 General Guidelines for Safety...4 2.0 Principle of measuring...5 3.0 Calibration...5 4.0 Description of the instrument...6 5.0 Switching Functions of the Relays...7 5.1 Function-diagram for contact K1...8 5.2 Function-diagram for contact K2...8 6.0 Setting of Limit Values...9 7.0 Remote control...9 8.0 Display...9 8.1 LED-Display...9 8.2 Indicator Lights of the Limit Values...9 9.0 Setting of the 20 ma Analog Output...10 10.0 Installion of the measuring device...11 10.1 Dimension sheet...12 11.0 Technical data...13 11.1 Connection diagram...13 Oct. 2005

Page 4 1.0 General Guidelines for Safety WARNING (Nonobservance or misapplication of the contents of the Warning section could lead to serious accident, including death or injury) Turn off the power supply. Working without disconnecting the power supply may cause an electrical shock. Before engaging upon any working procedures make sure to disconnect the power supply. No remodelling! Never remodel an analyser. Otherwise, a serious accident may result. IOTRONIC will not be responsible for any accident or damage of any kind which is caused by the user remodelling the analyser. Operating site must be free of water and humidity The analytical instrument is not designed to be water-proof or dust-proof. The use of the analyser in places where water splashes or humidity is high may result in an electrical shock or short-circuit. (Nonobservance or misapplication of the CAUTION! contents of the Caution section could lead to serious physical injury to the user or serious damage to the product.) Specified power only Do not operate the analyser on voltage which is not specified on the label on the right side of the transmitter housing. Failure to do so can result in damage or fire. Only the specified power level is to be applied. Do not damage or change power cable! Do not scratch, damage, process, or pull the power cable forcibly. Nonobservance could cause a fire or an electrical shock. Notes on operation Dropping the device or subjecting it to strong impacts may result in faulty performance. Handle the analyser with care. Select an installation site convenient for future maintenance and inspection, and fix the device carefully so that it is free of vibrations. Oct.2005

Page 5 2.0 Principle of measuring The main difference between the common conductive way and the inductive technique is the electrodeless measuring. No conductive electrodes are touch with the liquid.inside the probe there is a fully capsulated ring-core-transformer wich induces an ac current in the surrounding liquid.the value of the current is proportional to the conductivity of the liquid.with a second ring-core, wich acts as an current transformer the induced current is measured and after electronic processing in the measuring instrument displayed as conductivity. The inductive technique garantees a lasting stable and perfect reading even in strong contaminated, oily or agressive liquids. Problems of conventional elektrodes with the influence of reading caused by wear, corruption and polarisation are eliminated as a matter of principle. The expenditure of calibration,cleaning and maintenance is limited to a minimum or even not necessary in most applications. The unit of conductivity is S/cm.Derivations are ms/cm and µs/cm. 3.0 Calibration The instrument is calibrated by factory. To compensate tolerances of the cell, it is possible to adjust the measured value for +/- 10%. For a simple calibration, one need a buffersalution (potassiumchlorid 0,01 mol/l;=1913 µs/cm) Set the temperature compensation to 2,1%/ C. Then dip the sensor into the the buffer solution and wait until the reading does not change. Now set the reading with the slope adjustment element to a value of 1410 µs/cm. Oct. 2005

Page 6 4.0 Description of the instrument LF1 i2380: LF2 i2382: LF3 i2384: LF4 i2386: LF1 i2381: LF2 i2383: LF3 i2385: LF4 i2387: Device with maximum-function of relais Device with maximum-function of relais Device with maximum-function of relais Device with maximum-function of relais Device with minimum-function of relais Device with minimum-function of relais Device with minimum-function of relais Device with minimum-function of relais Front view (Example): a : LED-display f: manual override to operate valve b: indicator light alarm 10% g: keys to display limit values c: indicator light valve open h: potentiometer to adjust slope d: indicator light alarm +10% i: overflow (only LF2) e: potentiometer to adjust limit values Oct.2005

Page 7 The limit values may be adjusted by turning the screw of the appropriate potentiometer. The current limit values may be displayed by pressing the appropriate key (X1 or X2). The instrument has two potential-free relay contacts. Relay K2 may be used to control dosing devices (e.g. a valve). Relay K1 is an alarm relay that will be activated either if the measured value is 10% above or 10% below the preset limit values. 5.0 Switching Functions of the Relays Relay K2 XX x2380: XX x2382: (Blowdown plant) XX x2384: XX x2386: The relay contact K2 will be activated if the measured value goes beyond the preset limit value X2.It remains activated until measured value falls below preset value X1 XX x2381: XX x2383: XX x2385: XX x2387: XX x2389: The relay contact K2 will be activated if the measured value has fallen below the preset limit value X1. It remains activated until the preset limit value X2 is exceeded. Relay K1 The relay contact K1 will be activated either if the measured value has fallen below limit value X1 by more than 10% or the limit value X2 is exceeded by more than 10%. It may be used to control alarm devices like horn or light. Contact position shown not activated Oct. 2005

Page 8 Please observe technical specifications. 5.1 Function-diagram for contact K1 5.2 Function-diagram for contact K2 Oct.2005

Page 9 Manual Override of Relay K2 Pressing the key Y/Test may activate the relay contact K2. The contact is activated as long as the key is pressed. 6.0 Setting of Limit Values Adjust the limit values by using a screwdriver. The values may be adjusted by pressing the key X1 or X2 and turning the potentiometer located above each key until the desired value is displayed. Note: Limit value X2 has to be programmed higher than limit value X1. 7.0 Remote control To terminals 24/25 a remote contact may be connected.it controls the action of the relais.only when the remot contact is close,the relays may be active. When no remote control is used,terminals 24/25 must be linked. (Normal operation). Function of spezial operation is invers. Be shure not to connect strange voltage to terminal 24/25.Nonobservance could result in an electrical shock. 8.0 Display 8.1 LED-Display The multi-digit LED displays the present actual value. The programmed values for X1 or X2 are displayed by pressing the appropriate keys. In the event that the measuring range is exceeded the digits disappear and the highest digit indicates the fault. 8.2 Indicator Lights of the Limit Values Indicator lights indicate when the pre-set limit value is exceeded or the measured value has fallen below the pre-set limit value. Oct. 2005

Page 10 9.0 Setting of the 20 ma Analog Output 19 20 - + 0-20 ma The instrument delivers a current output, 0 or 4 to 20 ma, which may be used as input to remote recording devices, for data processing, controlling functions etc. The current output is independent of resistance load up to a value of 500 ohms. Be shure not to connect strange voltage to the terminal 19/20.Nonobservance could result in an electrical shock. The recorder output can be switched over from 0-20mA to 4-20mA by means of a jumper. Oct.2005

Page 11 10.0 Installion of the measuring device The instrument is build into a plastic-housing with dimensions 212 x 185 x 114 mm. The separate terminal box has on ist bottomand rearplate 11 pre-pressed cable bushings. On the back of the housing,there are 3 holes for wall-fixing.the control hole is to hang up the device,the other ones to fix it. WARNING Only Qualified Personnel! Only Specified Power Supply! See required power supply as noted on instrument. Observe local regulations! Install a power supply that can be disconnected (plug, switch). Use suitable cable bushings for cable inlet.take care for sufficient fixing of the connection cables. Do not install measuring-or control cables in parallel or close distance in the same cable guide with power supply. Oct. 2005

Page 12 10.1 Dimension sheet Oct.2005

Page 13 11.0 Technical data Range: 0-1999 µs/cm(resulotion:1 µs/cm),lf1 0-9990 µs/cm(resulotion:10 µs/cm),lf2 0-19,99 ms/cm(resulotion:0,01 ms/cm),lf3 0-199,9 ms/cm(resulotion:0,1 ms/cm),lf4 Reference temperature: 25 C Recorder output: Display: Indications: Relay contact: 0/4-20 ma - burden max. 500 Ohm multi-digit LED-display 3 LED for limit value 2 potential free SPDT max. 250V 50Hz 3A, cos phi min 0,7 General data Supply voltage: 230 V / 50 Hz (+10%/-15 %) (other voltages on request) Power consumption: Dimensions: approx. 4,5 VA 212 x 185 x 114 mm(width x height x depth) Protection: IP 65 Connection: Inline terminals 1,5 mm 2 Ambient temperature: - 5 C bis 50 C Technical modifications reserved! 11.1 Connection diagram K1 K2 32 ma 4-20 ma Temperature compensation shield white shield brown 1A 0-20 ma 1 1A 2 2A PE PE PE PE 3 4 5 6 7 8 24 25 9 10 11 13 14 15 1617 18 19 20 normal spezial L N remote control 230 V/ 50 Hz green yellow pink white blue red brown grey Inductive probe PT 1000 - + 20 ma Caution! Do not connect strange voltage to these terminals! Oct. 2005

Inductive conductivity probe MES 500 Measuring range : 0-200 ms/cm Temperature sensor PT 1000 integrated Conductivity probe completely mounted in PVC T-piece Screw connection (no further fittings required for installation) Pressure range PN 10 at max. 40 C Nominal diameter 20 mm (DN 20) Appropriate SENSOCON switching and control units: LF1..3 i2380..6 (MAX-Function) LF1..3 i2381..7 (MIN-Function) Order No. 330 500 01 Fillerkampsweg 1-5 31832 Springe OT Eldagsen Tel.: 05044/887-0 Fax: 05044/887-99 E-mail : info@iotronic.de Internet: http://www.iotronic.de 12-2011