Making the impossible data center a reality.

Similar documents
PROCESS & DATA CENTER COOLING. How and Why To Prepare For What s To Come JOHN MORRIS REGIONAL DIRECTOR OF SALES

How Liquid Cooling Helped Two University Data Centers Achieve Cooling Efficiency Goals. Michael Gagnon Coolcentric October

FREEING HPC FROM THE DATACENTRE

MSYS 4480 AC Systems Winter 2015

EP s approach to Power & Energy efficiency in DCs & paradigms

Application of Green Technology For Data Centre

Passive RDHx as a Cost Effective Alternative to CRAH Air Cooling. Jeremiah Stikeleather Applications Engineer

DC Energy, Efficiency Challenges

SmartRow Intelligent, Integrated Infrastructure in a Self-Contained Line-Up. Solutions For Business-Critical Continuity

Next Generation Cooling

NREL Validates LCS Technology. PRESENTED BY Herb Zien CEO, LiquidCool Solutions

SmartRow Solution Intelligent, Integrated Infrastructure for the Data Center

The End of Redundancy. Alan Wood Sun Microsystems May 8, 2009

Virtualization and consolidation

Capacity and Power Management: The Forgotten Factors in Disaster Recovery Planning Presented by: Clemens Pfeiffer CTO Power Assure, Inc.

MEASURE MONITOR UNDERSTAND

IT Air Conditioning Units

DCIM Data Center Infrastructure Management Measurement is the first step

Cooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.

84 kw, Tier 3, Direct Expansion, 937 ft 2

Future of Cooling High Density Equipment. Steve Madara Vice President and General Manager Liebert Precision Cooling Business Emerson Network Power

Planning a Green Datacenter

Eaton 93PM: Value, Benefits, and Features Eaton. All Rights Reserved..

INNOVATE DESIGN APPLY.

HIGH DENSITY RACK COOLING CHOICES

INNOVATE DESIGN APPLY.

SmartAisle Intelligent, Integrated Infrastructure Using Row-based Building Blocks. Solutions For Business-Critical Continuity

Data Center Temperature Design Tutorial. Ian Seaton Chatsworth Products

Green Data Centers A Guideline

Trends and legislations in the data center industry. Pär Åberg - Business Development Manager - Swegon

Make the most of your Energy from Power Plant to Plug. Chris Simard, Regional Director Field Sales Group

How High-Density Colocation and Enhanced Visibility Improve Business Performance

Product Brochure Eaton 93PR UPS kw

WHITE PAPER. Oil Immersion Cooling for Today s Data Centers. An analysis of the technology and its business

Modular & Mobile Data Centre Solutions. Data Centre Solutions Expertly Engineered

Pros and Cons of Various DC Distribution Architectures

Hot vs Cold Energy Efficient Data Centers. - SVLG Data Center Center Efficiency Summit

The Efficient Enterprise. All content in this presentation is protected 2008 American Power Conversion Corporation

How green is green? The environmental benefits of using Diesel Rotary UPS systems to support critical loads in the datacenter. Summary.

Microsoft s Cloud. Delivering operational excellence in the cloud Infrastructure. Erik Jan van Vuuren Azure Lead Microsoft Netherlands

7 Best Practices for Increasing Efficiency, Availability and Capacity. XXXX XXXXXXXX Liebert North America

Dealing with the Density Dilemma

Schneider Electric Cooling Portfolio. Jim Tubbesing Heath Wilson APC/Schneider North Texas Rep Tubbesing Solutions

Interested in conducting your own webinar?

SmartCabinet Intelligent, Integrated Containment for IT Infrastructure

Highly Efficient Power Protection for High Density Computing Applications

18 th National Award for Excellence in Energy Management. July 27, 2017

Data center redundancy. Air traffic High-speed pipes. Training Design. Costs. Guy with a wrench. Terrorism

High Density Cooling Solutions that work from Knurr Kris Holla

A Data Center Heat Removal System That Saves... 80% Discover Inertech s Award-winning Data Center Heat Removal System

Reducing Data Center Cooling Costs through Airflow Containment

Ecolibrium. Cloud control. Keeping data centres cool. OCTOBER 2018 VOLUME 17.9 RRP $14.95 PRINT POST APPROVAL NUMBER PP352532/00001

Compute Engineering Workshop March 9, 2015 San Jose

SMARTAISLE Intelligent, Integrated Infrastructure for the Data Center

Data Center UPS Systems Why 1% Efficiency Matters

DATA CENTER COLOCATION BUILD VS. BUY

Data Center Design: Power, Cooling & Management

Evaporative free air cooling technology Providing evaporative free air cooling solutions.

Data Centre Energy & Cost Efficiency Simulation Software. Zahl Limbuwala

SMART SOLUTIONS TM INTELLIGENT, INTEGRATED INFRASTRUCTURE FOR THE DATA CENTER

Efficiency of Data Center cooling

Ecoflair Air Economizers

Switch to Perfection

PLAYBOOK. How Do You Plan to Grow? Evaluating Your Critical Infrastructure Can Help Uncover the Right Strategy

IT infrastructure Next level for data center. Rittal The System Yavor Panayotov Data center Day

How to improve efficiency in Data Processing Centres (DPCs) The importance of knowing the PUE. center DPC

HPC Solutions in High Density Data Centers

Rittal Cooling Solutions A. Tropp

How much power?! Data Centre Efficiency. How much Money?! Carbon Reduction Commitment (CRC)

INT 492 : Selected Topic in IT II (Data Center System Design) 3(3-0-6)

Smart Solutions Intelligent, Integrated Infrastructure for the Data Center

One Stop Cooling Solution. Ben Tam Business Development Manager

Optimize Your Data Center. Gary Hill VP, Business Development DVL Group, Inc.

Maximise Data Center Value

Data Center Infrastructure Management (D.C.I.M.)

Vodafone Sustainability & Innovation in emerging market

Smart Data Centres. Robert M Pe, Data Centre Consultant HP Services SEA

Industry leading low energy evaporative fresh air cooling.

ENERGY STAR for Data Center Products: UPS plus Servers, Storage, and more April 24, 2012

System Overview. Liquid Cooling for Data Centers. Negative Pressure Cooling Without Risk of Leaks

E f f i c i e n c y b e y o n d t h e A C b a s e d d a t a c e n t e r d e s i g n s ; V D C p o w e r f e e d s o l u t i o n

Total Modular Data Centre Solutions

Air Containment Design Choices and Considerations

Power Consumption in the Data Center. Green Concepts

Validating Hyperconsolidation Savings With VMAX 3

Lecture 20: WSC, Datacenters. Topics: warehouse-scale computing and datacenters (Sections )

Cooling Solutions & Considerations for High Performance Computers

Cannon T4 Modular Data Center (MDC)

DATA CENTER LIQUID COOLING

Power & Cooling Considerations for Virtualized Environments

Cost Model Energy Benefits DirectAire & SmartAire Overview & Explanation

Newave s approach for protecting mission critical application

Innovative Data Center Efficiency Techniques. Michael K Patterson, PhD PE Eco-technology Program Office Intel Corporation

Excool Indirect Adiabatic and Evaporative Data Centre Cooling World s Leading Indirect Adiabatic and Evaporative Data Centre Cooling

Topics. CIT 470: Advanced Network and System Administration. Google DC in The Dalles. Google DC in The Dalles. Data Centers

Thermal management. Thermal management

Partner Introduction

POWERING A CONNECTED ASIA. Pacnet Hong Kong DataSpace1 Technical Specifications. Advanced Data Center Facility for Multi-Site Enterprises

3300 kw, Tier 3, Chilled Water, 70,000 ft 2

2000 kw, Tier 3, Chilled Water, Prefabricated, sq. ft.

Transcription:

United Nations ITU WSIS 2016 WINNER E-Environment Malaysia s First Win 2015 ASIA PACIFIC WINNER 2015 Best of Sustainability and Environmental Technology WINNER 2015 Best of Sustainability and Environmental Technology MERIT 2015 Best of Start-Up Companies Making the impossible data center a reality.

Data Centers Face Many Challenges

We Removed Air From The Equation, Solving Multiple Data Center Problems.

CURRENT INDUSTRY FACT IT Power = 1 Watt Cooling Power = 1 Watt Power Usage Effectiveness (PUE) = 2.0 HOW? We do away with CRAC, CRAH, Chillers or Fans. Air is a poor heat conductor. Kept at 21 C (7 C at chiller) to keep servers cool. [Eco 2 ] Economical & Eco-Friendly [Eco 2 ] FACT IT Power = 0.9 Watt Cooling Power = 0.1 Watt Power Usage Effectiveness (PUE) = 1.1 WHAT!!? Submersion cooling = 1356x more efficient at holding heat than air. [Eco 2 ] at 38 C is as efficient as 21 C air.

CASE STUDY: CRF DATA CENTER WWW.CRF.MY What Is Eco 2?

CASE STUDY: CRF DATA CENTER WWW.CRF.MY What Is Eco 2?

CLOUD IN A BOX POWERED BY Eco 2 DESIGN BRIEF: THE MOST COST EFFICIENT MODULAR GREEN DATA CENTER IN THE WORLD MOBILE: Fast and low cost transportation to provide computing resources in any location. MODULAR: Lego blocks methodology. koolkubes can be stacked up 7 levels high. Smallest Deployment Unit is 1/3 of a rack. PLUG & PLAY: Just plug in power and bandwidth. LOW CAPEX: Verified lowest capex globally & lowest opex regionally. Mikros Uses ambient MICRO DATA CENTER cooling with POWERED BY Eco 2 Eco 2 coolant. Rugged and weatherproof. PUE=1.0 324kw, scalable to 6372kw Up to 2268 1U Servers 480sf vs 1450sf conventional US$3 per watt CAPEX vs $10-$20/w The latest mobile applications needs ultra low latency, 15ms vs current 200ms. This is the biggest challenge of the industry right now. To fix this, the Internet needs to be redesigned or DCs need to be closer to users. We bring DCs closer.

Comparing With The Existing 1.6 Billion Square Feet of Global Data Center Space Using Air Cooling Component Air Cooling Eco 2 CRAC/CRAH REQUIRED NOT REQUIRED CHILLER REQUIRED NOT REQUIRED LARGE BACKUP GENERATOR AIR FLOW ENGINEERING FULL SIZE REQUIRED HALF SIZE NOT REQUIRED 70% less capital expenditure 50% less energy bill 50% less carbon footprint 80% Faster Deployment 30% Less Equipment Failure 40% Cheaper HDDs 8 Hours Disaster Recovery- Response Time Dust Free Operations Noise Free Operations Eco 2 vs Air Cooling vs Transformer Oil HOT/COLD AISLE REQUIRED NOT REQUIRED RAISED FLOOR/SPECIAL FLOOR REQUIRED NOT REQUIRED RACK RAILS REQUIRED NOT REQUIRED

Comparing With The Existing 20,000 Square Feet of Global Data Center Space Using Fluid Submersion Feature Eco 2 Transformer Oil DESIGN FOR ICT FOR TRANSFORMERS HEAT CAPACITY 118KW 100KW DIELECTRIC CAPACITY BREAKDOWN AT 75KV BREAKDOWN AT 45KV FLASH POINT >220 C >145 C FIRE POINT TOXICITY >220 C SAFE FOR HUMANS, ALL ADDITIVES FDA APPROVED >185 C WHO GROUP 1 CARCINOGEN FOR HUMAN TOTAL INFRA COSTS US$2/WATT US$4/WATT RENEWABLE YES NO SUSTAINABLE YES NO BIO-DEGRADABLE YES NO 66% more dielectric - capacity 18% more heat - conductivity 50% less capital - expenditure 51% higher flash point 19% higher fire point International Agency for Research on Cancer found Polycyclic Aromatic Hydrocarbons

MAJOR COST SAVINGS E.G: 0.5 MW (MEDIUM DC) CAPEX OPEX TCO ROI Eco 2 = US$1.0M Traditional = US$3.35M Eco 2 Cooling = US$87.6K /yr Air Cooling = US$876K /yr Eco 2 Maint. = US$125K /5yrs Air Cooling Maint. = US$525K /5yrs Eco 2 Savings = US$788K /yr 70% Lower* 90% Lower + 10% Lower IT** 76% Lower 15 Months *Based on 500kw IT equipment capacity. Includes racks & complete cooling. Excludes building, raised flooring, ICT, etc. **Based on US$0.20 per kwh, lower IT because of fans removals.

COMPARING SPECIFIC DEPLOYMENTS FOR MEGA DCs Eco 2 Conventional A Conventional B Conventional C Total Power Needed 24.3 MW 36MW 43MW 48MW Power Usage Effectiveness (PuE) Design Total Critical IT Load 1.11 1.5 1.8 2.0 21.6MW (10% less IT power due to fans removal) 24MW 24MW 24MW Cooling & Auxiliaries Load 2.7MW 12MW 19MW 24MW Cooling & Racking Infrastructure CapEX US$2 per IT Watt = US$48,000,000 US$6.5 per IT Watt = US$156,000,000 US$6.5 per IT Watt = US$156,000,000 US$6.5 per IT Watt = US$156,000,000 Annual Total DC Energy OpEX 212,868,000KWh x 0.45sen = RM95,790,600 315,360,000KWh x 0.45sen = RM141,912,000 376,680,000KWh x 0.45sen = RM169,506,000 420,480,000KWh x 0.45sen = RM189,216,000 Annual DC Carbon Footprint 157,735,188 MT CO 2 233,681,760 MT CO 2 279,119,880 MT CO 2 311,575,680 MT CO 2

STAYING TRUE TO OUR MISSION, ALWAYS. We are environmental stewards representing the ICT industry with the mission of helping preserve Earth for our future generations. One DC at a time, low cost. THANK YOU FOR YOUR TIME.