Jewelry Scale HT-500GD 1WMPD

Similar documents
SAFETY PRECAUTIONS WARNING. Repairs Do not disassemble the scale. Contact your local A&D dealer if your balance needs service or repair.

Weighing Indicator 1WMPD

BALANCES.COM. Contents

CAUTIONS... 4 INTRODUCTION...

Compact Balances. EK-610j EK-6100j. in an Authorized A&D Dealer

The contents of this manual and the specifications of the instrument covered by this manual are subject to change for improvement without notice.

Precision Health Scale UC-324NFC Instruction Manual

AD-4408A. Weighing Indicator for DeviceNet Interface AX-ABCC-DEVICE INSTRUCTION MANUAL 1WMPD

BALANCES.COM. Contents

With a PRINT foot switch With a REZERO foot switch For incorporating into a system External IR switch

Oxford E Series. Instruction Manual

Built-in Fanless Ionizer! BM-20. BM-22 (Smart range) BM-252. Series. Micro Analytical Balances BM-200 BM-300 BM g 0.

Classic Weight Scale. Model UC-502

GX GF. Series. aandd. jp ISO 9000 CERTIFIED. GX-400 with optional glass breeze break. GX-600 with standard breeze break

GP SERIES GP-12K/GP-20K/GP-22K/GP-30K GP-40K/GP-60K/GP-100K/GP-102K GP-30KS/GP-100KS

Analytical Balance BM-20 BM-22 BM-252 BM-200 BM-300 BM-500

part of this manual may be photocopied, reproduced, or translated into another language without the prior written consent of the A&D Company.

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

GX-K series. GF-K series

Product specifications are subject to change without any obligation on the part of the manufacture.

AD-8923-CC. Remote Controller (CC-Link) INSTRUCTION MANUAL 1WMPD

Counting Scale. HC-3Ki. HC-15Ki HC-6Ki WM+PD

WM+PD Weighing Indicator

GX-200/GX-300/GX-400 GX-600/GX-800/GX-1000 GX-2000/GX-3000/GX-4000/GX-6100 GX-6000/GX-8000

Counting Scale. FC-50Ki FC-20Ki FC-10Ki FC-5000i WM : PD

YJ Carat and Gold Scales

Counting Scale. FC-500Si. FC-50Ki FC-20Ki FC-10Ki. FC-500i. FC-2000i FC-1000i WM+PD B

WARNING CAUTION. This is a hazard alert mark.

AD Weighing Indicator INSTRUCTION MANUAL 1WMPD A

Multi Function Weighing Indicator

GF SERIES GF-200/GF-300/GF-400/GF-600/GF-800/GF-1000 GF-1200/GF-2000/GF-3000/GF-4000/GF-6100 GF-6000/GF-8000

CONTENTS. PRECAUTIONS Introduction Installation... 7

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

MODEL PS-11 DIGITAL PORTION SCALE

by A&D Pipette Management Solutions To protect research results from the threat of nonconformities Leak Tester: AD-1690

MWP SERIES. High Precision

Userʼs Guide. 1200g High Precision Scale. 1200g High Precision Scale. Legal for Trade. Includes RS-232 interface port. UG Version 1.

WM+PD Weighing Indicator

User Manual. Models: BL 303 BL 602 BL 2002 BL 3001 BL 6001 BL 30K1

FX-iWP SERIES. Dust and Waterproof Precision Balance INSTRUCTION MANUAL. FX-120i WP / FX-200i WP / FX-300i WP FX-1200i WP / FX-2000i WP / FX-3000i WP

Analytical Balance GH-120 GH-200 GH-300 GH-202 GH-252 1WMPD C

WM+PD Digital Sphygmomanometer

ANALYTICAL / SEMI-MICRO BALANCES

Operating instructions METTLER TOLEDO BD balances

APOLLO. Multi-Functional Precision Balances. Series GX-1003A GX-3002A. Taking Weighing Precision and Protection to New Heights.

1WMPD B MC-10K MC-30K

Adventurer TM Pro Analytical and Precision Balances

AD-4212A/B AD-4212A-100/200/600/1000 AD-4212B-101/102/201/301

Sartorius Element Series

CW Series Check Weighing Scales. Instruction Manual

Ohaus Hand-Held Scale Model HH 120D -OPERATING MANUAL-

1.0 Description. 2.0 Unpacking. 3.0 Installation

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual

OHAUS SCOUT BALANCE SCALE

AD SERIES SCALEIBALANCE INSTRUCTION MANUAL

1WMPD B MC-1000 MC-6100

Production Weighing Unit

IDS-801 Series Compact Bench Counting Scale. User Manual

Adam Equipment LBK SERIES. (P.N. 9596, Revision D, July 2014)

OHAUS Discovery. The Professional s Choice For Analytical Applications! Semi-Micro and Analytical Balances

Scout Resource Guide Scout Portable Balances

NB/NHB Precision Balance

STANDARD OPERATING PROCEDURE ACB SERIES ACB-600H PRECISION BALANCE

Discovery. Ohaus Discovery. Semi-Micro and Analytical Balances. The Professional s Choice For Analytical Applications!

Analytical Balance. HR-300i HR-202i 1WMPD C

MODEL KPS 68 MS KPS 180 MS DIGITAL BENCH SCALE Operation Manual

MODEL PS 150 PS 400 DIGITAL RECEIVING SCALE Operation Manual

Save $$ and buy at Analytical Balance GH-120 GH-200 GH-300 GH-202 GH-252

This document hosted by: High-Precision Tuning Fork Electronic Balance. SJ-E Series. Operation Manual IMPORTANT

BBA-Series Precision Balances

Adventurer TM Pro. The OHAUS Adventurer TM Pro The Most Complete Balance in Its Class! Analytical and Precision Balances

American Weigh Scales, Inc. AMW-BENCH. D i g i t a l T a b l e t o p S c a l e. User Manual

Series. Multi-Functional Precision Balances. Discover new ways to ensure accuracy, durability and productivity...!

Advanced Test Equipment Rentals ATEC (2832)

Targus Wireless 2.4 GHz Presenter

American Weigh Scales H-110. User Manual. H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4.

Adventurer Pro Analytical and Precision Balances

Manual Compact Scale / Balance PCE-BS 300 / 3000

FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale

INTRODUCTION TABLE OF CONTENTS

Adventurer TM Pro. The OHAUS Adventurer TM Pro The Most Complete Balance in Its Class! Analytical and Precision Balances

PX Series Balances. Quick Start Guide. Please download the user manual from

ANALYTICAL/SEMI-MICRO BALANCES

SELECTING THE LOCATION PREPARATION FOR USE. Pan Calibration Mass (only for SJX/E models with 64g capacity) Scoop (only for models with 64g capacity)

Discovery. The Professional s Choice For Analytical Applications! Semi-Micro and Analytical Balances

High-Precision Tuning Fork Electronic Balance. SJ-CE Series. Operation Manual IMPORTANT. To ensure safe and proper use of the balance, please read

AD-4212B AD-4212B-102 AD-4212B-201 AD-4212B-301

Adventurer TM Pro Analytical and Precision Balances

The Only Scale in its Class with Touchless Sensors That Free Up Your Hands!

Adventurer TM Pro Analytical and Precision Balances

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

Pro Balances. Frameless Draughtshield With Removable Doors Provides Convenient Access

INTRODUCTION INSTALLATION

OPERATING INSTRUCTIONS Press-to-Talk Wireless Microphone WM-5420

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5

The all-new OHAUS EXPLORER. Intelligent. Intuitive. Ingeniously Practical.

VWR BALANCES. A-Series Balances for High Precision with Advanced Features. B2-Series Balances are Rugged, Affordable, and Reliable

HI HI N HI HI

The all-new OHAUS EXPLORER. Intelligent. Intuitive. Ingeniously Practical.

CONTENTS. 1. Preface Features Technical Specifications Application of Dummy Plate Usage of Connector & Roller...

Transcription:

Jewelry Scale HT-500GD 1WMPD4002178

SAFETY PRECAUTIONS All safety messages are identified by the following, "WARNING" or "CAUTION", of ANSI Z535.4 (American National Standard Institute: Product Safety Signs and Labels). The meanings are as follows: WARNING CAUTION A potentially hazardous situation which, if not avoided, could result in death or serious injury. A potentially hazardous situation which, if not avoided, may result in minor or moderate injury. This manual is subject to change without notice at any time to improve the product. Product specifications are subject to change without any obligation on the part of the manufacture. When using the scale, the following safety precautions should always be followed. WARNING Repairs Do not disassemble the scale. Contact your local A&D dealer if your balance needs service or repair. Troubleshooting If a problem has occurred and you cannot clear it, stop using the scale, place a notice on the scale and request service from the store where you purchased the balance or from your local A&D dealer. CAUTION Conditions for use and Ambient Temperature The scale is a precision instrument. Avoid installing the scale in direct sunlight, excessive dust, high humidity, high temperature, large temperature fluctuations or magnetic fields, which may cause problems or malfunctions. Drafts and vibration may cause excessive weighing errors. Use the scale range of the -10 C to 40 C, with less than 85% R.H. Operation Avoid using the weighing pan to move the scale, as that could cause damage to the scale. Avoid overloading that could cause damage to the scale. The scale is not waterproof type. Water invading into the scale may cause damage. If the scale is not to be used for a long period of time, remove all batteries from the battery compartment to avoid battery leakage. Do not mix batteries made by different manufactures, or mix old and new batteries. Replace all of the batteries at one time. Use only the specified AC adapter for the scale (AC adapter is optional). 1

Compliance with FCC rules Please note that this equipment generates, uses and can radiate radio frequency energy. This equipment has been tested and has been found to comply with the limits of a Class A computing device pursuant to Subpart J of Part 15 of FCC rules. These rules are designed to provide reasonable protection against interference when the equipment is operated in a commercial environment. If this unit is operated in a residential area it may cause some interference and under these circumstances the user would be required to take, at his own expense, whatever measures are necessary to eliminate the interference. (FCC = Federal Communications Commission in the U.S.A.) PARTS DESCRIPTION Stainless steel weighing pan Weighing pan Color bar Display ON/OFF key UNITS key RE-ZERO key Calibration switch STABLE indicator Negative sign NET indicator ZERO indicator Weighing units Battery indicator 2

The ON/OFF key turns the scale power on/off. The RE-ZERO key sets the display to zero or subtracts the weight of a container in the weighing mode. The RE-ZERO key selects a parameter in the preset modes. The UNITS key changes weighing units in the weighing mode. The UNITS key selects item in the preset modes. The STABLE indicator indicates when the reading is stable in the STABLE weighing mode. The STABLE indicator indicates active units in unit selection. NET The NET indicates when the net weight is displayed. ZERO The ZERO indicates when the scale zero is correct. Battery remaining level, shown after power-on only. Errors Overload. The scale zero is out of range. Low battery. Replace used batteries with four new ones immediately. Calibration error. The weighing of zero or calibration mass is out of range. Installing batteries Step 1 Remove the battery cover. PREPARATION Step 2 Before use, remove the insulation tape from the battery compartment. Step 3 Insert 4 new batteries (AA size) into the battery compartment, taking extreme care of the polarities. Insulation tape Step 4 Replace the battery cover. Battery cover Note The batteries provided with the scale are for testing the performance of the scale and may have a limited life. 4 new batteries 3 Step 2 Step 1

When using the AC adapter Step 1 Verify that the AC adapter is correct. Step 2 Open the rubber cap and plug the AC adapter into the AC adapter jack. AC adapter jack Rubber cap Step 2 WEIGHING Step 1 Turning the scale on / off Press the ON/OFF key to turn the scale on. The scale displays all segments for a few seconds and then displays zero. Press the ON/OFF key again to turn the scale off. Step 2 Selecting the weighing unit Press the UNITS key to select the weighing unit. The scale will power up with the weighing unit that was in use when last turned off. Step 3 Weighing Verify that the reading is zero. If not, press the RE-ZERO key to zero the display. If you use a container for weighing, place an empty container on the weighing pan and press the RE-ZERO key to zero the display. Place the objects to be weighed on the weighing pan or in the container. When the reading becomes stable, the STABLE indicator is displayed. 4

FUNCTIONS Automatic Power Off Function If the scale is left ON and the STABLE indicator is displayed, the automatic power-off function turns power off after approximately 5 minutes. Step 1 Entering the preset mode. Press the ON/OFF key while pressing the RE-ZERO key. Step 2 Selecting the status. Press the RE-ZERO key to disable or enable this function. Automatic power off function is disabled Automatic power off function is enabled. Step 3 Storing the status. Press the UNITS key. The scale displays weighing mode. and returns to the Storing Weighing Units Among the units, those available for the user have been set at the factory before shipping. The unit can be selected in the preset mode. Refer to the table on the page 6 for the order of the units available, while skipping the units that are not available. Select and store the weighing units as described below. It is also possible to specify the display unit that will be shown first when the scale is turned on. Either Tael (HK general, Singapore) or Tael (Taiwan) can be selected. Step 1 Entering the preset mode. Press the ON/OFF key while pressing the UNITS key. Press the RE-ZERO key. Step 2 Selecting units. UNITS key Select the unit. RE-ZERO key The STABLE indicator indicates when to enable the unit. Select to disable or to enable the unit. ex. or. Step 3 Storing units. Press the UNITS key to display. Press the RE-ZERO key to return to the weighing mode. 5

Unit Unit name Conversion to gram At preset mode Gram 1 g Tola (India) 11.6638038 g Ounce (Avoir) 28.349523125 g Troy Ounce 31.1034768 g Pound (UK) 453.59237 g Tael (Taiwan) 37.5 g Tael (HK general, Singapore) 37.7994 g Pennyweight 1.55517384 g Metric Carat 0.2 g Newton is a value calculated as follows: Newton = (weight in gram) x (9.80665 m/s 2 ) / 1000. Selecting The Decimal Point Step 1 Entering the preset mode. Press the ON/OFF key while pressing the UNITS key. Press the UNITS key to display the current decimal point. or. Step 2 Selecting a decimal point. Press the RE-ZERO key to select decimal point or. Step 3 Storing the decimal point. Press the UNITS key to display. Press the RE-ZERO key to return to the weighing mode. Setting The Stability Step 1 Entering the preset mode. Press the ON/OFF key while pressing the UNITS key. Press the UNITS key to display the current setting. or. Step 2 Selecting a filter. Press the RE-ZERO key to select or for the filter response. Step 3 Storing the selected filter response. Press the UNITS key to display. Press the RE-ZERO key to return to the weighing mode. 6

CALIBRATION When is Calibration Required? Calibration may be required when the scale was initially installed or has been moved to another location. Calibration switch Step 1 Switch cover Calibration Using a Calibration Weight Step 1 Entering the calibration mode Remove the switch cover located on the bottom of the scale. Press the ON/OFF key to turn the scale on. Press the Calibration switch while the scale is in the weighing mode. will be displayed. Step 2 Zero calibration Press the RE-ZERO key. will be displayed. Wait for the STABLE indicator to be displayed with nothing on the weighing pan. Press the RE-ZERO key to perform zero calibration. will be displayed after a few seconds. Select next step as follows: Proceed to the span calibration of Step 3. Press the UNITS key to return to the weighing mode without performing span calibration. Step 3 Span calibration When is displayed, place the calibration weight on the center of the weighing pan. Wait for the STABLE indicator to be displayed. Press the RE-ZERO key to perform span calibration. will be displayed and the scale will automatically return to the weighing mode. Remove the calibration weight from the weighing pan. Note For details about the calibration weight, Refer to "SPECIFICATIONS". 7

Calibration by Gravity Compensation If the acceleration of gravity at your location is not correct and you do not have calibration weights, the scale can be calibrated by compensating for the acceleration of gravity. Refer to "The Value of Gravity at Various Locations". Step 1 Setting a new acceleration value Press the ON/OFF key to turn the scale on. Press the Calibration switch while the scale is in the weighing mode. Press the UNITS key when is displayed. The current acceleration value will be displayed. ex.. Change the value with following keys. RE-ZERO key Increments the blinking digit. UNITS key Moves the blinking digit. Step 2 Storing the value into the memory While pressing the UNITS key, press and hold the RE-ZERO key and release the UNITS key. After, will be displayed. Turn the scale off to finish the procedure. SPECIFICATIONS MODEL HT-500GD Weighing capacity 510 g Resolution 0.1 g Non-linearity ±0.2 g Repeatability (Std. deviation) 0.1 g Span drift ±150 ppm/ C (5 C to 35 C / 41 F to 95 F) Operating temp. -10 C to 40 C / 14 F to 104 F, Less than 85%RH Display 13.5 mm / 0.53 inches, 7segment liquid crystal display Display update Approximately 10 times per second Power supply 4 x R6P / LR6 / "AA" size batteries or AC adapter Battery life Approximately 450 hours with alkaline cells at 20 C / 68 F Pan size 132 (W) x 130 (D) mm 5.2 (W) x 5.1 (D) in. Dimensions 195 (W) x 136 (D) x 44 (H) mm 7.7 (W) x 5.4 (D) x 1.7 (H) in. Approximately weight 610 g Max. Tare weight 510 g Calibration weight 500 g ±0.01 g Accessories 3 color bars, stainless steel weighing pan, this manual, 4 "AA" size monitor batteries Options AC adapter 8

Gravity Acceleration At Various Locations Amsterdam 9.813 m/s 2 Madrid 9.800 m/s 2 Athens 9.807 m/s 2 Manila 9.784 m/s 2 Auckland NZ 9.799 m/s 2 Mexico City 9.779 m/s 2 Bangkok 9.783 m/s 2 New York 9.802 m/s 2 Brussels 9.811 m/s 2 Milan 9.806 m/s 2 Buenos Aires 9.797 m/s 2 Oslo 9.819 m/s 2 Calcutta 9.788 m/s 2 Ottawa 9.806 m/s 2 Cape Town 9.796 m/s 2 Paris 9.809 m/s 2 Chicago 9.803 m/s 2 Rio de Janeiro 9.788 m/s 2 Copenhagen 9.815 m/s 2 Rome 9.803 m/s 2 Nicosia 9.797 m/s 2 San Francisco 9.800 m/s 2 Jakarta 9.781 m/s 2 Singapore 9.781 m/s 2 Frankfurt 9.810 m/s 2 Stockholm 9.818 m/s 2 Istanbul 9.808 m/s 2 Sydney 9.797 m/s 2 Havana 9.788 m/s 2 Taipei 9.790 m/s 2 Helsinki 9.819 m/s 2 Tokyo 9.798 m/s 2 Kuwait 9.793 m/s 2 Vancouver, BC 9.809 m/s 2 Lisbon 9.801 m/s 2 Washington DC 9.801 m/s 2 London (Greenwich) 9.812 m/s 2 Wellington NZ 9.803 m/s 2 Los Angeles 9.796 m/s 2 Zurich 9.807 m/s 2 3-23-14 Higashi-Ikebukuro, Toshima-ku, Tokyo 170-0013 JAPAN http://www.aandd.jp/ A&D Australasia Pty Ltd. 32 Dew Street, Thebarton, South Australia 5031 AUSTRALIA http://www.andmercury.com.au/ A&D ENGINEERING, INC. 1756 Automation Parkway, San Jose, California 95131 U.S.A. http://www.andonline.com/ A&D KOREA Limited 8th Floor, Manhattan Bldg. 36-2 Yoido-dong, Youngdeungpo-ku, Seoul, KOREA http://www.andk.co.kr/ 9 A&D INSTRUMENTS LTD. Unit 24/26 Blacklands Way, Abingdon Business Park, Abingdon, Oxon OX14 1DY United Kingdom http://www.aandd-eu.net/ A&D RUS Co.,ltd. 121357, Российская Федерация, г.москва, ул. Верейская, дом 17 http://www.aandd.ru