DINB100-SA Standalone Biometric Reader

Similar documents
DINB100-SA Standalone Biometric Reader

DINB100-SA-KIT Standalone Biometric Kit

B100-SA Standalone Biometric Reader

B100PROX-MF-SA Standalone Biometric Mifare Reader USER S MANUAL. Relay1 time (for Relay 1 in B100PROX-MF-SA,RU2, RTT and DINRTT )

CV-945 Stand-Alone Biometric Reader. Installation Instructions

EX8. User Manual. Ver 1.0

BIOC3 V1 USER S MANUAL. Biometric Reader v. b1

DINBIOC3 V1 USER S MANUAL. EN Biometric Reader. v.b2

B100PROX-EH(AH) Biometric Proximity Reader INSTALLER MANUAL

BIOPROX-MF V1 Biometric Mifare Reader

BIOPAD-M Biometric Keypad Reader User s Manual

BIOPAD-M V1. Biometric keypad reader INSTALLER MANUAL. v.b2

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

DG-800 Stand-Alone Proximity Reader Instruction Manual

Fingerprint Access Control F1. User Manual

VIS-3200 / VIS-3201 User Manual

DOLXFD1000B. Waterproof Access Control/Reader

Waterproof. Keypad/Reader/Controller

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

FTK5 PROXIMITY KEYPAD

CM-110SK Standalone Keypad Installation Instructions

Partizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating

RFT1000 reader in RACS 5. User Manual

1. Product Specification

EcoEntry. RFID Proximity Access Control System. User Guide. Revision 2

DO NOT LOSE THIS SHEET - YOUR FACTORY MASTER CODE IS UNIQUE TO YOUR KEYPAD

Single Door Standalone Access Control User Manual

W3-H Waterproof Keypad/Reader/Controller

Portals 14 What is a portal? 14 Hardware 15 RS232 to RS USB to RS TCP/IP to RS Add a Serial Portal 16 Add a Network portal 16

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

REX F-0-9 Standalone or Access Controller

ACCESS CONTROL STAND ALONE & PC BASED SYSTEMS.

Standalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit

Standalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm

VIDI-AC-2CS Access Controller/ Reader

SL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.

AS Keypad User Manual

Operation manual For NG BIOSINGLE Version 1.1

GV-AS Controller. Installation Guide

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

Digital Keypad Introduction

Installation and User Manual

VANDAL RESISTANT BACK-LIT WEATHERPROOF ACCESS CONTROL KEYPAD

PA5000 SERIES USER MANUAL

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

RBR-SB-KTZ001 LAR 2. User Manual

Fingerprint Door Lock User MANUAL

SOLAR. User manual of high security level electronic lock. Gebaude Sicherheitstechnik Vertriebs GmbH, Kassel

W3-M. Metal waterproof standalone access control/reader. User Manual

.

BHD-8000 Access Control Keypad and Card Reader. Wiring Diagram

QUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control

DT-AKP 2 WIRE SYSTEM. User Manual. Access keypad panel with scramble keypad DT-ENG-AKP-V1 /

Finger Vein Access Control device Quick Start Guide Version: 1.0 Date: June USB slot. USB slot

Fingerprint Door Lock OPERATOR S MANUAL

GV-Card Reader. User s Manual

1 IF-810 or IF-811 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-810/IF-811

Stand-alone Proximity Access Control

TEC100 USER/INSTALLER MANUAL V2.0 REV. 03/2018

EL-ST100 KEYPAD CONTROLLER

Contents Safety precautions Product components Optional accessories Names of each parts Product Dimension Cables and Connectors Power Connection

1 IF-812 or IF-815 Terminal (Slave) 2 Intended Use. 3 Assembly and Installation _V IF-812/IF-815

ACCESS CONTROL SYSTEM

Gallagher T12 Reader. Installa on Note. The Gallagher T12 Reader

BIO-PRO Standalone / Weigand fingerprint reader

GV-AS/EV Controller. User s Manual

INSTALLATION INSTRUCTIONS 920P EntryCheck TM

Metal Standalone Keypad Access Control S100

F18. Fingerprint capacity 3,000 Transaction capacity 100,000 Hardware Platform ZK 6001, 400Mhz 64M Flash, 32MSDRAM. Identification speed

User Manual. Split access control with intelligent secured power supply.

Synergis Master Controller 2.2 Integration Guide for Axis Interface Modules

-DTZ001- Stand-Alone Proximity Access Control. User Manual

ACTsmart2 Product Range Operating and Installation Instructions

Access control panel U-Prox IC E (Elevator control)

User Manual. PCKeypad Wireless Keypad

CM-500 SK 500 USER CODES KEYPAD

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

Wiring Guide. EP.NMiNi 2. Version 1.04 Last Updated:

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

IPassan Installation guide

RXTH DUAL ROOM SENSOR / SWITCH

BioLite Net. Firmware Revision Notes EN BLN V1.43. Biometrics & Security. Version 1.43

INSTALLATION INSTRUCTIONS 920 EntryCheck TM

S125 Multi-Purpose 125 KHz RFID Reader USER MANUAL. 9V/24V DC Operating Voltage, AC (optional) KHz RFID EM4100/2 Cards & Tags

BioPointe. User's Manual

Quick Start Guide. ProBio & ProFAC + ZKBioSecurity 3.0

Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate

INSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control

RFID/Digital Access Control Keypad

Biometric finger print entry system.

F7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions

Car Video Recorder. RoadRunner 535W. User Manual

Specifications: Features:

_ Access control SISTEMAS DE SEGURIDAD

Kinetic Switch APP User Manual

Biometric Lock Programming & Operating Instructions. info. code. Biometric Lock Information. Setting The Master Code. Enrolling A Fingerprint

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

K44 Code lock. Technical manual

INSTALLATION INSTRUCTIONS 921P EntryCheck TM

4 Wire Video Intercom System

Transcription:

EN DINB100-SA Standalone Biometric Reader User Manual v.b2

Contents 1.0 INTRODUCTION... 3 2.0 MOUNTING AND DISMOUNTING... 3 3.0 SPECIFICATIONS... 3 4.0 APPLICATION DIAGRAM... 4 5.0 WIRING... 4 6.0 RECOMMENDED SWIPING TECHNIQUE... 5 6.1 Tapping the sensor... 5 6.2 Scrolling the sensor up and down... 5 7.0 INDICATION... 5 8.0 QUICK PROGRAMMING... 6 8.1 Adding Master Finger and delete all users... 6 8.2 Add User In Group 1... 7 8.3 Add User In Group 2... 7 8.4 Delete user... 7 8.5 Delete All Users in Group 1... 7 8.6 Delete All Users in Group 2... 7 9.0 PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT... 8 9.1 Pairing DINB100-SA with DINRTT... 8 9.2 Pairing DINB100-SA with RTT... 8 10.0 KEEP THE DOOR UNLOCK... 8 11.0 DINB100-SA PROGRAMMING MENU... 9 11.1 Adding Users... 9 11.2 Delete User... 10 11.3 Delete All users... 10 11.4 Delete Group of Users... 11 11.5 Add Administrator... 12 11.6 Delete Administrator... 13 11.7 Settings... 14 11.7.1 Double Swipe Unlocks Door, Entry Mode, Remote Relay Touch Function... 15 11.7.2 Buzzer Sound, Backlight, Reset to defaults... 16 11.8 Set Door Relay Time... 17 11.9 Adding Users In Finger On Card Mode (when Mifare Reader is connected)... 18 12.0 PROGRAMING DINB100-SA WITH KEYPAD... 19 12.1 Adding Users... 19 12.2 Delete User By User Location Number... 20 12.3 Delete User Group... 20 12.4 Delete All Users... 21 12.5 Delete User by User Finger... 21 12.6 Set Door Relay Time... 22 12.7 Buzzer Settings... 23 12.8 Backlight Settings... 24 12.9 Set the Touch Button Function... 25 12.10 Unpair Remote Relay... 25 12.11 Entry Mode Settings... 26 12.12 Add Administrator... 27 12.13 Delete Administrator... 27 12.14 Reset to defaults... 28 12.15 Double Swipe Unlocks Door... 28 2

1.0 INTRODUCTION DINB100-SA is a simple one-door standalone biometric system. The reader can store up to 97 finger templates, it has one relay output and one exit button input. If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also plays the role of request-to-exit push button. Proximity reader or keypad can be added for additional entry mode (Card or/and Finger, PIN Code or/and Finger, Finger on Card). Complete setup and programming can be done by scrolling and tapping on the sensor or by keypad menu if keypad is connected. The sensor incorporates dedicated sensing hardware to facilitate the detection of spoofing attacks based on fake fingers. This data is embedded into the image data stream, and is processed on the processor. The system is capable of detecting and defeating well-known fake finger mechanisms, such as molded gummy fingers. The coating on the surface of the TouchChip sensor provides protection from scratching and abrasion due to normal contact with fingertips and any incidental contact with fingernails. The reader is capable of working in so called Finger on Card mode, where the authentication is done by verifying that the biometric data stored on the card matches the finger being placed on the reader. 2.0 MOUNTING AND DISMOUNTING Do not install the device and cabling close to a source of strong electro-magne c fields like radio-transmi ng antenna. Do not place the device near or above hea ng equipments. If cleaning, do not spray or splash water or other cleaning liquids but wipe it out with smooth cloth or towel. Do not let children touch the device without supervision. Note that if the sensor is cleaned by detergent, benzene or thinner, the surface will be damaged and the fingerprint can't be entered. 3.0 SPECIFICATIONS Fingerprint Capacity: Output: Push Button Input: Door Open Time: Entry Mode: Programming: Master/Admin Fingers: Image resolution: Backlight ON/OFF: Buzzer ON/OFF: Firmware upgrade: Current Consumption: Power Supply: Indication: Mounting: IP Factor: Storage/Operating Temperature : Storage/Operating Humidity: Dimensions(mm): 97 templates 1 x Relay (2A/24V AC/DC) Yes Pulse (1, 3, 5, 10, 20, 30, 60sec) or Toggle(ON/OFF) Finger (Basic installation) Finger or/and Card (when used with card reader DIN Card reader) Finger or/and PIN code (when used with keypad DINPAD-M) Finger on Card (when used with mifare reader DINMTPX-MF) By scrolling and tapping on the sensor or by keypad 1 Master and 2 Admin Fingers Up to 508 DPI Yes Yes via RS485 converter and windows application 100 ma max. 9-14 V DC Tricolor Status LED and 4 x Programming LEDs Flush mount IP40-20 C to +50 C 5% to 93% RH without condensation 80 x 80 x 9 3 DINB100-SA

4.0 APPLICATION DIAGRAM DINRTT (Op onal) 2 Relay Remote Unit and request-to-exit Bu on Op onal Keypad 1 2 3 4 5 6 7 8 9 A 0 B OR RS485 (max. 50m) use the cable provided with the keypad/reader OR RTT (Op onal) 1 Relay Remote Unit and request-to-exit Bu on Secured Area Outside DINB100-SA Standalone Biometric Reader Op onal Proximity Reader 5.0 WIRING Note: Frame sold separately Relay Output NC C NO NC C NO Jumper (Adding Master Finger) DINB100-SA Connection to additional card reader or keypad 12V B A PB tamp tamp +12V B A PB tamp tamp Power Supply (9-14V DC) RS485 Push Button Tamper Electric Door Strike (DC powered) + - 1N4007 C NO NC C NO 12V B A PB tamp tamp tamp tamp 12V PB (PB) Exit Bu on (NO) Alarm + - 12 VDC 4

6.0 RECOMMENDED SWIPING TECHNIQUE 6.1 Taping the sensor Tap the sensor to enter Submenu or to confirm a command Follow the below instructions for correct finger swiping Starting from the first finger joint, place the selected finger on the swipe sensor and move it evenly towards oneself in one steady movement. Result: For a valid swipe: Tricolour Status LED turns green + OK Beep(short + long beep) For an invalid or misread swipe: Tricolour Status LED turns red + Error Beep ( 3 short beeps) Enter and confirm 6.2 Scrolling the sensor up and down Scroll the sensor DOWN to navigate the programming menu Navigate the Programming Menu Scroll the sensor UP to exit the programming menu Exit the Programming Menu 7.0 INDICATION Tricolor Status LED Green - Access Granted Red - Access denied Orange - Idle Mode 4 x Tricolor Programming LEDs (red, green, orange) OK Beep - short + long beep Error Beep - 3 short beeps Swipe Again - 2 short beeps 5

8.0 QUICK PROGRAMMING 8.1 Adding Master Finger and delete all users 1.Close the jumper on the back of the device. DINB100-SA 2.Reset the Power of the device. 3.Wait for One long + mul ple short beeps A B 12V 4.Open the jumper. (short beeps will stop) 5.Wait for the bo om row LEDs to blink in Orange. Blinking> <Blinking 6.Swipe the Master finger min.6 mes. (Un l Ok Beep) x 6 Note: A er enrolling the Master finger the device will auto-reset (wait for 7 seconds and the OK beep). Note: This procedure also deletes all the users and administrators previously enrolled. 1. There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs. The Master finger can be changed ONLY with the jumper. 2. There are 2 Administrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master. 3. The User can be assigned to one of the 8 available User Groups. With the Quick programming feature, the Users are assigned in Group 1 or Group 2. For most of the installa ons 2 groups are enough and can be used as: Group 1 for permanent residents, Group 2 for guest and visitors. 4. The user can be deleted by swiping its user finger or by dele ng the group in which that user is enrolled. Once the Group of users is deleted, all the users within that group will be deleted. 5. The Groups are not limited by the number of users. (ex. Group 1 can contain 20 users, Group 2 can contain 70 users, but the total number must remain bellow 97...) 6

8.2 Add User In Group 1 Figure.1 1. Swipe the Master or Admin Finger 2. Swipe the user finger min. 6 mes (un l Ok Beep) Master Finger x 1 User Finger x 6 8.3 Add User In Group 2 Figure.2 1. Swipe the Master or Admin Finger twice 2. Swipe the user finger min. 6 mes (un l Ok Beep) Master Finger x 2 User Finger x 6 8.4 Delete User Figure.1 1. Swipe the Master or Admin Finger 2. Swipe the user finger (already enrolled) Master Finger x 1 User Finger x 1 8.5 Delete All Users in Group 1 6 sec. Figure.4 1. Swipe the Master or Admin finger 3 mes, 2. Wait 6 seconds for the light pa ern on figure.4 3. Swipe the Master or Admin finger once more Note: All fingers that are enrolled in Group 1 will be deleted. Master Finger x 3 wait 6 seconds Master Finger x 1 8.6 Delete All Users in Group 2 6 sec. Figure.6 1. Swipe the Master or Admin finger 4 mes, 2. Wait 6 seconds for the light pa ern on figure.6 3. Swipe the Master or Admin finger once more Note: All fingers that are enrolled in Group 2 will be deleted. Master Finger x 4 wait 6 seconds Master Finger x 1 If you make any mistake or you just simply want to exit Quick Programming, wait for the meout of 10 seconds. With this, the quick programming is completed. The system is now opera onal with default value for Door Open Time of 3 seconds. For more comprehensive programming, refer to the DINB100-SA Programming sec on. Important: When using proximity reader for Finger Or/And Card Mode, first present the Card then swipe the finger min. 6 mes. When using keypad for Finger Or/And Pin Code mode first enter the PIN Code, then swipe the finger min. 6 mes. When using Mifare card reader for Finger On Card Mode first swipe the finger min. 6 mes, then present a Card. For Fast Dele ng a user in Finger On Card mode swipe the Master or Admin finger then present an exis ng user card 7

9.0 PAIRING - BIOMETRIC READER AND REMOTE RELAY UNIT If secure installation is needed, the reader can be connected to remote relay unit at secured area, which also plays the role of request-to-exit push button. Follow the instructions bellow to pair(couple) both devices or refer to the Remote Relay s Manual. 9.1 Pairing DINB100-SA with DINRTT 12 VDC + - 1N4007 + - 1 2 DINB100-SA DINRTT NO1 NO1 COM COM NC1 NO2 COM NC2 1. Close the Jumper. DINRTT beeps con nuously and the red led blinks. 2. Open the Jumper 3. Wait for Beep + OK Beep (short + short + long beep) A B 12V Exit Button (NO) PB1 PB1 PB2 +12V +12V A B RS485 TAMP TAMP A er the OK beep, the coupling is done. A B +12V +12V +12V A B RS485 - + 12 VDC max. 50m 9.2 Pairing DINB100-SA with RTT 12 VDC + - 1N4007 + - DINB100-SA NO RTT COM ON 1 2 1. Put Dipswitch No.1 to posi on ON. RTT beeps con nuously and the red led blinks. 2. Put Dipswitch No.1 to posi on OFF. 3. Wait for Beep + OK Beep (short + short + long beep) A B 12V A er the OK beep, the coupling is done. A B +12V +12V A B RS485 - + 12 VDC max. 50m 10.0 KEEP THE DOOR UNLOCKED Swipe ANY enrolled finger twice (within 7 seconds) and the Door will stay unlocked, un l valid finger is swiped. While the door is unlocked the tricolor status LED stays green. User Finger x 2 To use this feature, enable the same from the menu.(page 15). It applies for product version 1.0.2.0.0 and above. Note: Make sure that the door lock can withstand ac va on in longer periods. 8

11.0 DINB100-SA PROGRAMMING MENU 11.1 Adding Users Swipe the Master/Admin finger 5 mes un l the light pa ern on figure.9 is shown Figure.9 x 5 Select User Group Swipe the finger to select: Group 1 Group 5 Group 2 Group 6 Group 3 Group 4 Group 7 Group 8 Assign Relay Output Swipe the finger to select: Relay 1 Both Relay 2 None NOTE: Swipe UPWARDS to exit the MENU (Orange Blinking) Swipe the user finger for Finger mode min.6 mes. When using proximity reader for Finger Or/and Card Mode, first present the Card then swipe the finger min. 6 mes. When using keypad for Finger Or/And Pin Code mode first enter the PIN Code, then swipe the finger min. 6 mes. Example: Task: Add a user in Group2, that will ac vate Relay1. Scroll Master Finger 5 mes, tap, scroll ones, tap, tap, swipe user finger 6 mes, swipe UP to exit. 9

11.0 DINB100-SA PROGRAMMING MENU 11.2 Delete User Swipe the Master/Admin finger 7 mes un l the light pa ern on figure.12 is shown Figure.12 x 7 Blinking row > Swipe finger or present Card or enter PIN NOTE: Swipe UPWARDS to exit the MENU OK Beep Back to MAIN MENU 11.3 Delete All Users Swipe the Master/Admin finger 11 mes un l the light pa ern on figure.14 is shown Figure.14 x 11 Blinking row > to confirm or swipe UP to Cancel NOTE: Swipe UPWARDS to exit the MENU OK Beep deleting... 10 Note: The Master and the Administrators will not be deleted Back to MAIN MENU

11.0 DINB100-SA PROGRAMMING MENU 11.4 Delete Group of Users Swipe the Master/Admin finger 6 mes un l the light pa ern on figure.13 is shown Figure.13 x 6 Select User Group to Delete Swipe the finger to select: Group 1 Group 5 Group 2 Group 6 Group 3 Group 4 Group 7 Group 8 OK Beep Back to MAIN MENU NOTE: Swipe UPWARDS to exit the MENU Note: All fingers that are enrolled in the Group will be deleted. Example: Task: Delete all users in Group3 Scroll Master Finger 6 mes, tap, scroll twice, tap, swipe UP to exit. 11

11.0 DINB100-SA PROGRAMMING MENU 11.5 Add Administrator Swipe the Master/Admin finger 12 mes un l the light pa ern on figure.10 is shown Figure.10 x 12 Select Admin nr. Scroll down to select: Admin 1 Admin 2 (Orange Blinking) Swipe the Admin finger min.6 mes.(un l Ok beep) x 6 Note: If keypad is connected, enter the User Pin Code, then swipe the user finger min.6 mes(un l Ok Beep). Back to MAIN MENU (to Add User menu) NOTE: Swipe UPWARDS to exit the MENU - There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs. - The Master finger can be changed ONLY with the jumper. - There are 2 Aministrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master. 12

11.0 DINB100-SA PROGRAMMING MENU 11.6 Delete Administrator Swipe the Master/Admin finger 13 mes un l the light pa ern on figure.11 is shown Figure.11 x 13 Select Admin nr. Scroll down to select: Admin 1 Admin 2 deleting.. OK Beep NOTE: Swipe UPWARDS to exit the MENU Back to MAIN MENU - There is 1 Master Finger. The master finger can enroll/delete user and all the other se ngs. - The Master finger can be changed ONLY with the jumper. - There are 2 Aministrator Fingers. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master. 13

11.0 DINB100-SA PROGRAMMING MENU 11.7 Se ngs Swipe the Master/Admin finger 10 mes un l the light pa ern on figure.7 is shown Figure.7 x 10 Blinking row > By swiping finger select appropriate light pa ern Swipe the finger to select: Double Swipe Unlocks Door Remote Relay Touch Function Sensor security Buzzer Entry mode Backlight Reset to defaults Continues on the next 2 pages go to next page NOTE: Swipe UPWARDS to exit the MENU Entry Mode - used when addi onal proximity or keypad reader is connected Remote Relay Touch Func on - Enabling/Disabling the Touch Bu on Func on in the remote relay Unit Buzzer - Enabling/Disabling the Buzzer Backlight - Enabling/Disabling the Backlight 14

11.0 DINB100-SA PROGRAMMING MENU 11.7 Se ngs 11.7.1 Double Swipe Unlocks Door, Entry Mode, Remote Relay Touch Func on Double Swipe Unlocks Door Entry MODE Remote Relay Touch Function Double Swipe Unlocks Door Scroll down to select: 1 ON 2 OFF product ver. 1.0.2.0.0 By swiping finger select entry mode Finger Finger OR PIN Finger AND PIN Finger OR Card Scroll down to select: Finger AND Card Finger ON Card Touch Button ON/OFF Scroll down to select: 1 ON 2 OFF OK Beep OK Beep OK Beep Back to MAIN MENU Back to MAIN MENU Back to MAIN MENU Note: Refer to Chapter 10 for this feature NOTE: Swipe UPWARDS to exit the MENU Example: Task: Set the Reader to work in Finger and Card mode Scroll Master Finger 10 mes, tap, scroll twice, tap, scroll 4 mes, tap, swipe UP to exit. 15

11.0 DINB100-SA PROGRAMMING MENU 11.7 Se ngs 11.7.2 Buzzer Sound, Backlight, Reset to defaults Buzzer sound Backlight Reset to defaults Buzzer ON/OFF Scroll down to select: Remote OFF Reader OFF All ON All OFF Backlight ON/OFF Scroll down to select: Remote OFF Reader OFF All ON All OFF Reset to defaults Tap to confirm: product ver. 1.0.2.0.0 OK Beep OK Beep OK Beep Back to MAIN MENU Back to MAIN MENU Back to MAIN MENU Note: Does not affect the fingerprints stored and the pairing NOTE: Swipe UPWARDS to exit the MENU Example: Task: Put the Buzzer OFF. Scroll Master Finger 10 mes, tap, scroll 4 mes, tap, scroll ones, tap,, swipe UP to exit. 16

11.0 DINB100-SA PROGRAMMING MENU 11.8 Set Door Relay Time Relay1 time (for Relay 1 in DINB100-SA, RTT and DINRTT ) Relay2 time (for Relay 2 in DINRTT Remote Relay Unit) Swipe the Master/Admin finger 8 times x 8 Swipe the Master/Admin finger 9 mes x 9 Blinking row > Blinking row > Select relay open time Select relay open time Scroll down to select: Scroll down to select: 1 sec 20 sec 1 sec 20 sec 3 sec 30 sec 3 sec 30 sec 5 sec 10 sec 60 sec Toggle 5 sec 10 sec 60 sec Toggle OK Beep OK Beep Back to MAIN MENU Back to MAIN MENU NOTE: Swipe UPWARDS to exit the MENU Example: Task: Put Relay1 to stay ac vated 10 seconds. Scroll Master Finger 8 mes, tap, scroll 3 mes, tap,, swipe UP to exit. 17

11.0 DINB100-SA PROGRAMMING MENU 11.9 Adding Users In Finger On Card Mode (when Mifare Reader is connected) Swipe the Master/Admin finger 5 mes un l the light pa ern on figure.9 is shown Figure.9 x 5 Select User Group Swipe the finger to select: Group 1 Group 2 Group 3 Group 4 Group 5 Group 6 Group 7 Group 8 Assign Relay Output Swipe the finger to select: Relay 1 Both Relay 2 None NOTE: Swipe UPWARDS to exit the MENU (Orange Blinking) Swipe the user finger min.6 mes (Un l Ok beep). x 6 The backlight starts to blink green and the buzzer beeps. Present the Card and hold it in the proximity field un l OK beep, which is indica on that the finger enrolled is wri en in the card. In Finger on Card mode, the fingerprint is stored only into the Mifare card (Mifare Classic 1K/4K or DesFire) and not in the reader. The matching is done by first presenting the card, then swiping the finger. According to this, the system in finger on Card mode does not have capacity limit. Furthermore, the fingerprint is not stored in the reader s memory, which disables any misuse of the stored fingerprint templates Example: Task: Add a user in Group2, that will ac vate Relay1. Scroll Master Finger 5 mes, tap, scroll ones, tap, tap, swipe user finger 6 mes, present the card, swipe UP to exit. 18

1 2 3 4 5 6 7 8 9 A 0 B 12.0 PROGRAMING DINB100-SA WITH KEYPAD 12.1 Adding Users Important: To use the keypad for programming, Master Finger must be enrolled. Please refer to page 6, to enroll Master finger. Then, set the Entry Mode to Finger or PIN. Please refer to page 14 & 15 to set the reader in Finger or PIN mode. In addi on to that, set the keypad to work with the biometric reader: Press B+000000 Press 0 Press 2 - slave mode Press A Press B+000000 Press 4 Press 0 - Any PIN Code length with A in the end Press A ADMIN PIN or x 5 1. Press 1 2. Enter user loca on number 01 to 97 3. Assign relay. Press 1 for Relay1 or 2 for Relay2 4. Assign user group 1 to 8.(Press 1 for group 1...) 5. Press A to confirm Op onal Note: The user is automa cally assigned to Relay1 and group1 6. Enter user PIN code. (1 to 8 digits) Op onal 7. Press A to confirm Swipe the User finger min.6 mes.(un l Ok Beep) x 6 To Enroll again go to step 1. To Exit press 0, A Example: Task: Add a user no.5, with PIN Code: 12345, that will ac vate Relay1. Scroll Master Finger 5 mes, press 1, press 05, press A, press 12345, press A, Swipe Finger 6 mes, press 0,A to exit 19

1 2 3 4 5 6 7 8 9 A 0 B 12.0 PROGRAMING DINB100-SA WITH KEYPAD 12.2 Delete User By User Loca on Number ADMIN PIN or x 5 1. Press 7. 2. Enter user loca on number, 01 to 97. 3. Press A to confirm. To Exit press 0, A 12.3 Delete User Group ADMIN PIN or x 5 1. Press 8. 2. Enter group number, 0 to 8. 3. Press A to confirm. To Exit press 0, A Note: All fingers that are enrolled in the Group will be deleted. 20

1 2 3 4 5 6 7 8 9 A 0 B 12.0 PROGRAMING DINB100-SA WITH KEYPAD 12.4 Delete All Users ADMIN PIN or x 5 1. Press 9. 2. Press 5,1,3,5,7. 3. Press A to confirm. To Exit press 0, A 12.5 Delete User by User Finger ADMIN PIN or x 5 1. Press 6. 2. Press A. 3. Enter user PIN then press A or swipe the user finger. To Exit press 0, A 21

1 2 3 4 5 6 7 8 9 A 0 B 12.0 PROGRAMING DINB100-SA WITH KEYPAD 12.6 Set Door Relay Time ADMIN PIN or x 5 1. Press 2. 2. Press 1 or 2 to select Relay1 or Relay2 3. Select the me code from the Table1. Table1. Time Codes Time Mode 1 1 sec 2 3 sec 3 5 sec 4 10 sec 5 20 sec 6 30 sec 7 60 sec 8 Toggle 4. Press A to confirm. To Exit press 0, A Example: Task: Put Relay1 to stay ac vated 10 seconds. Scroll Master Finger 5 mes, press 2, press 1, press 4, press A, press 0,A to exit. 22

1 2 3 4 5 6 7 8 9 A 0 B 12.0 PROGRAMING DINB100-SA WITH KEYPAD 12.7 Buzzer Se ngs 1. Press 3,1. 2. Select the Buzzer Code from the Table2. Table2. Buzzer Code Buzzer Mode 1 Remote OFF 2 Reader OFF 3 All ON 4 All OFF 3. Press A to confirm. To Exit press 0, A Note 1: When Remote OFF is selected, the buzzer is OFF in the remote relay unit. In the biometric reader and in the keypad the buzzer is ON. Note 2: When Reader OFF is selected, the buzzer is ON in the remote relay unit. In the biometric reader and in the keypad the buzzer is OFF. 23

1 2 3 4 5 6 7 8 9 A 0 B 12.0 PROGRAMING DINB100-SA WITH KEYPAD 12.8 Backlight Se ngs 1. Press 3,2. 2. Select the Backlight Code from the Table 3. Table 3. Backlight Code Backlight Mode 1 Remote OFF 2 Reader OFF 3 All ON 4 All OFF 3. Press A to confirm. To Exit press 0, A Note 1: When Remote OFF is selected, the backlight is OFF in the remote relay unit. In the biometric reader and in the keypad the backlight is ON. Note 2: When Reader OFF is selected, the backlight is ON in the remote relay unit. In the biometric reader and in the keypad the backlight is OFF. 24

1 2 3 4 5 6 7 8 9 A 0 B 12.0 PROGRAMING DINB100-SA WITH KEYPAD 12.9 Set the Touch Bu on Func on 1. Press 3,3. 2. Select the Touch Code from the Table 4. Table 4. Touch Code Touch Mode 1 Touch ON 2 Touch OFF 3. Press A to confirm. To Exit press 0, A Remote Relay Touch Func on - Enabling/Disabling the Touch Bu on Func on in the remote relay Unit 12.10 Unpair Remote Relay 1. Press 3,5. 2. Press 7,1,5,9. 3. Press A to confirm To Exit press 0, A 25

1 2 3 4 5 6 7 8 9 A 0 B 12.0 PROGRAMING DINB100-SA WITH KEYPAD 12.11 Entry Mode Se ngs 1. Press 3,4. 2. Select the Entry Mode from the Table 5. Table 5. Entry Codes Entry Mode 1 Finger 2 Finger or PIN 3 Finger and PIN 4 Finger or Card 5 Finger and Card 6 Finger ON Card 3. Press A to confirm. To Exit press 0, A Example: Task: Set the Reader to work in Finger and PIN mode Scroll Master Finger 5 mes, press 3, 4, press 3, press A, press 0,A to exit. 26

1 2 3 4 5 6 7 8 9 A 0 B 12.0 PROGRAMING DINB100-SA WITH KEYPAD 12.12 Add Administrator x 5 1. Press 4,1. 2. Press 1 or 2 to select Admin1 or Admin2 3. Press A to confirm. 4. Enter Admin PIN code.(1 to max 8 digits) 5. Press A to confirm Swipe the Admin finger min.6 mes.(un l Ok Beep) x 6 To Exit press 0, A - There is 1 Master Finger, but no master PIN Code. The master finger can enroll/delete user and all the other se ngs. - The Master finger can be changed ONLY with the jumper. - There are 2 Administrator Fingers and 2 Administrator PIN Codes. In order to enrol Admin, Master Finger MUST be enrolled first. The administrator can do all the things that Master can do. The Master can delete the Administrator, but the Administrator can not delete the Master. 12.13 Delete Administrator ADMIN PIN or x 5 1. Press 4,0. 2. Press 1 or 2 to select Admin1 or Admin2 3. Press A to confirm. To Exit press 0, A 27

12.0 PROGRAMING DINB100-SA WITH KEYPAD 12.14 Reset to defaults product ver. 1.0.2.0.0 1. Press 3,6. 2. Press 9,1,4,7. 3. Press A to confirm To Exit press 0, A Note: Does not affect the fingerprints stored and the pairing 12.15 Double Swipe Unlocks Door product ver. 1.0.2.0.0 1. Press 3,3. 2. Select the Double Swipe from the table Double swipe Unlocks Door 1 Enable 2 Disable 3. Press A to confirm. To Exit press 0, A Note: Refer to Chapter 10 for this feature This product herewith complies with requirements of EMC directive 2014/30/EU. In addition it complies with RoHS directive EN50581:2012 Visual Plus Corporation, s.a. Drève Richelle 161 WOP G - Bte 34 1410 Waterloo - Belgium 28