CERBERUS. Cerberus multi I/O. Datasheet. Shaping the future of sound reinforcement. Cerberus. Applies to Part Number:

Similar documents
Installation & User Manual

AMC 8 & IOC 8T. Analog Monitoring Card Type AMC 8 and Input / Output Card Type IOC 8T FEATURES

MSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range

Installation & User Manual

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

Installation & Operation Guide

2 Table of Contents 1. TABLE OF CONTENTS. 1. Table of Contents Introduction Wiring Diagram Terminals Review...

User Guide. Target System Power Amplifier Module

AUTROVOICE MULTIVES EXCHANGEABLE MODULES

ISOMETER isoev425 with coupling device AGH420

CSI 6300 SIS Overview

MC138 LCD CONTROL BOARD

Installation & User Manual (Preliminary)

ACOPOSinverter P74. User's Manual. Version: 2.20 (August 2016) Model no.: Original instruction

ZP-PI335GK-BT User s Manual

HPA4202 1/5. 2-Channel High Power Multi-Impedance Amplifier. General Description. Features. Applications. AtlasIED.com. HPA4202 Front.

Relay Deck Datasheet

Installation Manual for D244X Series 24-volt Power Supplies

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

TSXCTY2A 2 channels counter modules - 40 khz - 30 ma at 24 V DC, 280 ma at 5 V DC

ISOMETER isoev425/isoev425hc with coupling device AGH420

C160 Wall-/Pipe Mounted Universal Process Indicator

Strain Gage Measuring Amplifier GSV-3

MP-2000 Dual Channel LVDT/RVDT Readout/Controller

CheckSum. FUNC-2B Functional Test Module. The FUNC-2B features:

Discrete I/O 12 Discrete Inputs 8 Relay Outputs CANopen P/N: AXDIO128CO

Technical Manual Nova: Cabinet Security Management System (CSMS)

BS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0

Accessories and options

Stereo / Mono. Audio Power Amplifier W. Introduction. Applications

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

MOTION COORDINATOR MC405 Quick Connection Guide

OPERATING INSTRUCTIONS PA AMPLIFIER P-1812

/8 DIN Universal Process Indicator

Data Sheet T 6493 EN. TROVIS 6400 Automation System TROVIS 6493 Compact Controller. For panel mounting (front frame 48 x 96 mm/1.89 x 3.

Product type designation. General information. Supply voltage. Input current

ControlSpace ESP-1240 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

Wall-/Pipe Mounted Universal Process Indicator

DRTS 33. The new generation of advanced three phase relay test set

IP-3000 Series. IP Network Public Address System. Monitoring and setting can be done easily by logging-in to control GUI via browser.

VCL-TP, Teleprotection Equipment With Trip Counter Display Panel

Synchro-check relay. Application

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

Product type designation. General information. Supply voltage

Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs

MSR178DP. Description. Features. Specifications

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

1073N. Channel Amplifier. User Manual Issue 1.3

MOTION COORDINATOR MC403 / MC403-Z Quick Connection Guide

ControlSpace ESP-1240 TECHNICAL DATA SHEET. engineered sound processor. Key Features. Product Overview. Product Information.

BMX DDM Mixed Relay Input/Output module

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

MCX402DR-BRD I/O expander. Operating Manual

VCL-TP, Teleprotection Equipment

Internal Buffer/Boiler Module HZS 534

MSR 2400R. Rugged Power System for Military and Heavy Duty Applications

Voltage regulator. SPAU 341 C 1MRS MBG Issued: July 1998 Status: Revised Version: C/ Data subject to change without notice

8-Channel Relay Output Board Via I 2 C Protocol. I2C-Relay8

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

N8000. Electro-Voice N8000. Full IRIS-Net Software Support. 32-Channel Digital Matrix Bus. 115 db Dynamic Range

E101 - Strain Gauge Transducer Display Module. Contents

dual-line 6-dIGIt process MeteR

Voice Alarm System VX-3000 Series

Feeder protection relay SPAA 121 C. Product Guide

Sensitive Earth-fault Relay SPAJ 111 C. Product Guide

RPX Series USER S MANUAL

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

AWARD WINNING PRODUCTS AND SERVICES TAKING OUT COST AND INCREASING OPERATING EFFICIENCY

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

P522 Signal Processor

MIC-2 Multi-instrument DATA SHEET

H3CA-8H-AC/100/110/120

Earth-fault Relay SPAJ 110 C. Product Guide

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

VMS Co., Ltd. VMS Reliability Systems - Korea

Amplifiers, Counters, Timers & Controls

PT2060 Monitor. PT2060/91 SIM System Interface Module. Specifications. Electrical. Messtechnik

Temperature Switches

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG03

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

Millenium II +: general characteristics

HZS Solar Module

SCP for Plastics Processing

Process displays For current and voltage

Overview. Features. Technical Data Sheet 1 / 6. Mixing Console AG06

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

I/O module (Expansion module)

DLCP. Digital Loudspeaker Cross-over Platform Datasheet

TOA INTERCOM SYSTEM TELEPHONE LINE INTERFACE

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

Large DIspLay process Meters

STATUS Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

Data sheet. MCX15B electronic controller MAKING MODERN LIVING POSSIBLE. REFRIGERATION & air CONDITIONING DIVISION. Danfoss Electronics spa

ISOMETER isopv with coupling device AGH-PV

POE084824B. PoE 54V/8x0,3A/4x7Ah PoE buffer power supply for up to 8 IP camera. v.1.1 EN* Edition: 7 from

JUMO Quantum PID100/PID200/PID300

Measuring transducers MI4x0 series Programmable transducers for RTD sensors MI450

812/ 814/ 815 digital timers

Spider. Quick Start Guide. What is in the box What does it do How to build a setup Verification of working... 8

Transcription:

CH17 CH18 CERBERUS Datasheet Applies to Part Number: 391010 Cerberus multi I/O Cerberus Multi I/O Surveillance Station RS-485 Input 1 DG Y Z B A DG Y Z B A RS-485 link Input 2 Analog Inputs(0-10V) +5V +5V Outputs max. 200mA CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH1 CH19 CH20 CH21 CH22 CH Shaping the future of sound reinforcement

User Notice: No part of this document including the software described in it may be reproduced, transmitted, transcribed, stored in a database system or translated without the express written permission of Duran Audio BV. Documentation kept by the end-user for backup purposes is excluded from the above mentioned. All products and corporate names mentioned in this document may be registered trademarks or copyrights of their respective companies. They are used here for indicative purposes only. The information contained in this document has been carefully checked for accuracy, however no guarantee is given with respect to the correctness. Duran Audio BV accepts no responsibility or liability for any errors or inaccuracies that may appear in this document or the products and/or software described in it. Specifications and information contained in this document are subject to change at any time without notice. 2 201605/CERB_2.1

Table of Contents 1. Architectural and Engineering Specifications...4 2. Specifications...5 3. Functional Diagram...8 4. Digital Input Diagram...9 5. Mechanical Details...10 7. Optional Accessories...12 201605/CERB_2.1 3

1. Architectural and Engineering Specifications The unit shall be constructed as a 1U 19 rack enclosure. The unit shall be primarily designed as a processor controlled multi-channel I/O interface with RS-485 network support and shall be suitable for any of the following applications: Redundant amplifier control applications (in conjunction with AXYS multi-channel amplifiers and redundant amplifier switching kit). Monitoring of third party devices (by using an AXYS WinControl Server). Providing a common fault relay for multiple devices (stand-alone mode). The unit shall be equipped with 32 digital inputs, 2 electronically balanced analogue DC voltage inputs, 8 relay outputs, a common failure relay, a full-duplex RS-485 network input & link interface, status LEDs and a reset switch. The digital inputs shall be suitable for logic high/low level monitoring as well as impedance sensing applications (by means of configurable pull-up current sources). The internal RISC processor shall be equipped with a watchdog timer and a manual reset switch. Firmware updates shall be supported over the network. Sufficient internal memory shall be provided in order to support at least 8 internal device presets. The processor shall facilitate the monitoring of all I/O states and failure conditions over the network. The inputs, outputs, network and failure relay shall be connected to Phoenix type MC 1,5/ x-st-3,81 connectors. The unit shall be equipped with an IEC mains inlet connector. The enclosure shall be constructed of steel finished with a nickel plating. All connectors shall be grouped together on the rear of the chassis. The front of the enclosure shall accommodate a mains switch and various status LEDs. Dimensions are 43.5 mm H x 482 mm W x 232 mm D. Weight 3.2 kg. The multi I/O device shall be the AXYS Cerberus. The analogue inputs shall be suitable for DC voltage monitoring and shall offer a high input impedance and a high common mode voltage range. Supply outputs (+5 V DC) shall be provided to power an external sensor. All related thresholds shall be software configurable. 4 201605/CERB_2.1

2. Specifications Electrical: Digital inputs - Number of digital inputs : 32 - Type 1 : differential - Nominal level : 0 to +5 V DC - Maximum level : +/- 24 V DC - External impedance 2 :10 kω / 20 kω - Internal pull-up 3 : pull-up current sources Analogue inputs - Number of analogue inputs : 2 - Type : electronically balanced - Nominal level : 0 to +10 V DC - Maximum level : +/- 50 V DC - Common mode range : +/- 150 V - Impedance 4 : 2 MΩ - Sensor supply output 5 : +5 V DC / 200 ma per pin Outputs - Number of outputs : 8 - Type : one single-pole changeover (SPDT) relay per output - Rating : 100 ma / 24 V - Mode 6 : general purpose or failure controlled - Failure controlled features 6 : - activate or de-activate output on failure 7 - priority for single/multiple output assertion 8 - delayed switching 9 - failure mask for any digital/analogue input and combined failures Monitoring - Digital input monitoring 10 : - open-circuit failure - short-circuit failure - default state failure - Analogue input monitoring 11 : - upper threshold failure - lower threshold failure - Output monitoring 12 : all outputs can be monitored by digital input 25 to 32 - Failure relay 13 : double-pole changeover (DPDT) 100 ma / 24 V Processor - Type : 200 ns single cycle RISC - Memory : 2 Mb non-volatile (EEPROM) - Self-monitoring : hardware WDT - Reset switch : access hole on rear panel Network control unit - Interface type 14 : serial full-duplex RS-485, optically isolated - Baud rate : autoswitching 115k2, 57k6, 38k4,19k2 baud - Topology 15 : parallel connection (multi-drop) - Maximum number of units 16 : 126 per subnet - Maximum cable length 17 : 2 km 201605/CERB_2.1 5

Connectors - Digital inputs : Phoenix type MC 1,5/ 2-ST-3,81 (32 x) p1 = +, p2 = - - Analogue inputs : Phoenix type MC 1,5/ 4-ST-3,81 (2 x) p1 = +, p2 = AGND, p3 = -, p4 = +5 V DC supply - Outputs : Phoenix type MC 1,5/ 3-ST-3,81 (8 x) p1 = Common (CO), p2 = Active closed (AC), p3 = Active open (AO) - RS-485 interface : Phoenix type MC 1,5/5-ST-3,81 p1 = DGND, p2 = Y, p3 = Z, p4 = B, p5 = A - RS-485 link 18 : Phoenix type MC 1,5/ 5-ST-3,81 p1 = DGND, p2 = Y, p3 = Z, p4 = B, p5 = A - Failure relay 19 : Phoenix type MC 1,5/ 3-ST-3,81 (2 x) p1 = Common (CO), p2 = Normally closed (NC), p3 = Normally open (NO) - Mains : 3p IEC connector Indicators 20 - Supply monitoring LED 21 : green - Failure relay LED 22 : green (OK) / red (failure) - Identification LED 23 : green - RS-485 send 24 : orange - RS-485 receive 25 : orange PSU - Type : switched-mode - Mains voltage : 100 V to 240 V, 50 or 60 Hz - Mains fuse(s) : 1 x 3.15 A (slow type, integrated in IEC mains connector) - Power consumption : 4 W, 8 VA (typical) - Protection : - thermal protection - output current limiting - under-voltage and over-voltage lock-out General: Temperature range (ambient) : 0 to 40 C (32 to 104 F) Dimensions (H x W x D) : 43.5 x 482 x 232 mm (1U 19 rack enclosure) Weight : 3.2 kg (7 lbs) Finish : Nickel plated 6 201605/CERB_2.1

Notes: 1. The digital inputs can either be used as voltage monitoring inputs (pull-up disabled) or as impedance sensing inputs (pull-up enabled). See section 4 for details. 2. Typical external resistance values for impedance sensing line monitoring applications (pull-up enabled). 3. Individual 0.12 ma current sources per digital input. Can be enabled/disabled per group of 8 digital inputs. 4. Typical differential input impedance at DC. 5. The sensor supply output pins are hardwired linked and connected via a Polyfuse self-resettable PTC to the internal +5 V supply. 6. Software configurable for each output individually, requires firmware v4.80 or higher to be installed. 7. For supporting additional failure relay outputs (de-activate) or redundant amplifier control (activate). 8. 8 priority levels are available for mutually exclusive output assertion, as required for redundant amplifier control. Additionally priority level 0 corresponds to no priority which allows multiple outputs to be asserted simultaneously. 9. Delayed switching can be set for each output individually however a common delay parameter is shared with the general failure relay. 10. All related thresholds are software configurable per group of 8 digital inputs. 11. All related thresholds are software configurable for each analogue input individually. 12. Hardware configurable (internal jumpers) for each output individually. This allows self-monitoring of the output relay status. 13. Software configurable failure conditions. 14. Individual balanced connections for transmit and receive. 15. Star configuration allowed, depending on cable properties. Closed loop not allowed. 16. Maximum number that can be connected to one subnet, multiple subnets can be controlled by one host PC. 17. Approximate maximum length that can be obtained with good quality data cable. 18. Hardwired link. 19. CO is connected to NC if the device is switched-on and has no failure. 20. All indicators on the front side of the unit. 21. This LED indicates if the device is switched-on and the internal +5 V power supply is OK. 22. This LED indicates the status of the Failure relay. 23. This LED is used for device identification on the RS-485 network. 24. This LED indicates if the device transmits data over the RS-485 network. 25. This LED indicates if data is received over the RS-485 network. 201605/CERB_2.1 7

3. Functional Diagram Digital input 1 to 8 CH1 In 1 Pull-Up OUT 1 CH2 In 2 OUT 2 CH3 In 3 OUT 3 CH4 In 4 OUT 4 CH5 In 5 OUT 5 CH6 In 6 OUT 6 CH7 CH8 In 7 In 8 Micro Controller OUT 7 OUT 8 Digital input 9 to 16 Digital input 17 to 24 Digital input 25 to 32 Input 1 Input 2 External failure relay Front LEDs Reset switch RS-485 & RS-485 link Internal supplies Sensor supply + 5V PSU Mains 8 201605/CERB_2.1

4. Digital Input Diagram 201605/CERB_2.1 9

5. Mechanical Details 1 3 2 5 4 6 Cerberus Power supply OK Status external failure relay Identification RS-485 Send RS-485 Receive Multi I/O Surveillance Station Front Panel 18 RS-485 Input 1 DG Y Z B A +5V CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16 Out1 Out2 Out3 Out4 CO AC AO CO AC AO CO AC AO CO AC AO CO NC NO Analog Inputs(0-10V) Outputs max. 200mA Failure Relay A B Reset Mains 100-240V~ 20W DG Y Z B A +5V CH17 CH18 CH19 CH20 CH21 CH22 CH23 CH24 CH25 CH26 CH27 CH28 CH29 CH30 CH31 CH32 Out5 Out6 Out7 RS-485 link Input 2 Inputs Outputs Out8 MADE BY DURAN AUDIO BV, ZALTBOMMEL, HOLLAND Rear Panel 7 9 11 13 15 RS-485 Input 1 DG Y Z B A +5V CH1 CH2 CH3 CH4 CH5 CH6 CH7 CH8 CH9 CH10 CH11 CH12 CH13 CH14 CH15 CH16 Out1 Out2 Out3 Out4 CO AC AO CO AC AO CO AC AO CO AC AO CO NC NO Analog Inputs(0-10V) Outputs max. 200mA Failure Relay A B Reset DG Y Z B A +5V CH17 CH18 CH19 CH20 CH21 CH22 CH23 CH24 CH25 CH26 CH27 CH28 CH29 CH30 CH31 CH32 Out5 Out6 Out7 Out8 RS-485 link Input 2 Inputs Outputs 8 10 12 14 16 17 Detailed view of rear connections 1. Mains switch 7. RS-485 interface 13. Relay outputs 1 to 4 2. Power supply LED 8. RS-485 link 14. Relay outputs 5 to 8 3. Status LED 9. Analogue DC input 1 15. Failure relay contacts A 4. ID LED 10. Analogue DC input 2 16. Failure relay contacts B 5. RS-485 send 11. Digital inputs 1 to 16 17. Reset switch 6. RS-485 receive 12. Digital inputs 17 to 32 18. IEC mains inlet 10 201605/CERB_2.1

31 43,5 464,7 482 223,35 232 445 450 201605/CERB_2.1 11

7. Optional Accessories USB - RS485 converter Includes WinControl and drivers Order code: 387802 WinControl Server Order code: 386600 12 201605/CERB_2.1

DURAN AUDIO BV Koxkampseweg 10, 5301 KK Zaltbommel, The Netherlands. tel. +31 418 515583 fax. +31 418 518077 http://www.duran-audio.com Info@duran-audio.com