SED2 VFD NEMA Type 3R Bypass/Air Conditioner

Similar documents
SED2 Variable Frequency Drives Conventional Bypass (C-Bypass) Options

SED2 Variable Frequency Drives with Electronic (E) Bypass Options

SED2 Variable Frequency Drives

BT300 HVAC Drives Electronic Bypass (E-Bypass) Options

SED2 Variable Frequency Drives

HVAC Products. Introducing the SED2 Variable Frequency Drives

SED2 Variable Frequency Drives

BT300 HVAC Drives. Designed for HVAC. Description. Technical Specification Sheet Document No March 4, 2013

5 MICROMASTER 420 specifications

Variable Frequency Drives

5 MICROMASTER 440 specifications

Powermite 599 MT Series SAS Electronic Valve Actuator 24 Vac or 24 Vdc, Proportional Control

A drive dedicated to variable speed control for HVAC applications

PowerFlex 400 AC Drive Guide Specification

SSW06. Soft Starters.

4/8/ nd Annual OTCO WW Workshop W/WW Product Overview ACQ550. ABB Slide 1

VLT 2800 DRIVE SPECIFICATIONS

C. New or replacement products installed in existing facilities shall be consistent with existing equipment.

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller for Smoke Control

ABB Industrial Systems Inc. Standard Drives. ACH500-06E Effective 6/1/95

ENGINEERED SOLUTIONS. Solutions for Any Application. us.mitsubishielectric.com/fa/en/

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Siemens BACnet Programmable TEC Unit Vent Controller for Smoke Control

E510. Compact Drive IP 20/ NEMA HP (230V) 1-75 HP (460V)

Free Energy Band RCC30U Room Temperature Controller for Four-pipe Fan Coil Unit

SSW06. Soft Starters. Applications. Standard Features. Pumps Fans Blowers Compressors Crushers Saws Grinders Mixers.

Q9 ASD LOW VOLTAGE DRIVE

SECTION VARIABLE FREQUENCY DRIVES

PowerFlex 40 Sample Specification

Siemens BACnet Programmable TEC VAV with Series Fan and 3-Stage Electric Heat Controller

ACS Product Overview

BuildingName The Description of the Project P DOCUMENTS

Siemens BACnet Programmable TEC Unit Conditioner Controller

Unitary Controller. Features. Description. Technical Specification Sheet Rev. 6, March, 2000

Siemens BACnet Programmable TEC Unit Vent Controller

Easy To Use OEMS Take Note

Siemens BACnet Programmable TEC Unit Conditioner (Fan Coil) Controller

Pump Data Sheet - Patterson HVAC Pumps Company: Intermountain Hydron Name: Cache County Mountain Crest Date: 09/24/2018

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

SED2 VFD NEMA Type 3R and 3R Harsh Environment (3RHE) Bypass Operating Instructions

SED2 Variable Frequency Drives Startup, Operation, and Maintenance Manual

User s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual

ATV1200A kv kva. Phase-shifting transformer Medium voltage arrestors Cooling fans Human machine interface Plinth (2) Power cells (9)

ATV1200A kv kva

ATV1200A kv kva

VFD 4x STAINLESS STEEL ENCLOSURE WITH AC. engineering data and specifications

SED2 Variable Frequency Drives

599 Series Zone Valve Actuator SF Series Electronic Valve Actuator, 2-position Control

Global Field Devices COMMERCIAL HVAC COMPONENTS ENGINEERED FOR SUCCESS. Application And Selection Guide

SCC Inc. TS Series. Technical Instructions. Document No. TS-2000 March 15, 2016

Siemens BACnet Programmable TEC Dual Duct Two Air Velocity Sensors Controller

P7BR. Description 5-500HP P7/Bypass NEMA 3R. Phone: Fax: Page Web: 61www.clrwtr.com -

ADJUSTABLE SPEED DRIVES. Q9 Series

Controls. Reduced Power Cost Extended Heater Life Less Maintenance Improved Process Products Stable Process Temperature. 4232/4233 Features

Submittal Schedule Details for VFD-P101, P201, P202, P310, P302, P401, P402

Siemens BACnet Programmable TEC Constant Volume

RWD68U Universal Controller

Q-LINK SMART BYPASS. SIZING INFORMATION TABLE Q-Link Variable Frequency Drive - 3-Phase 208 VAC 230 VAC VAC HP FLA HP FLA HP FLA TECHNOLOGIES

Standard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter

ACH550 Product Overview

Powermite 599 MT Series SSC Electronic Valve Actuator, 24 Vac Floating Control

Actuator Commissioning Tool

It s fun to save. micromaster

MAKING MODERN LIVING POSSIBLE. ADAP-KOOL Drive. A New Drive for Energy Efficiency AKD 102 REFRIGERATION & AIR CONDITIONING DIVISION

PXC Compact Unitary Equipment Controller (UEC)

Powered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support

Technical Manual Nova: Cabinet Security Management System (CSMS)

Submittal Data Information SmartDRIVE HVAC Variable Speed Drives

For additional PowerFlex 4M data and general drive information, refer to the following publications:

S-Flex Enclosed Drive

Submittal Data Information SmartDRIVE SP Variable Speed Drives

Submittal Data Information SmartDRIVE VP Variable Speed Drives

TR200 DRIVE WITH ELECTRONICALLY CONTROLLED BYPASS SYSTEM

TR200 DRIVE STANDARD FEATURES

BACnet Terminal Box (VAV) Controller

SmartVFD Frame 8 Wiring Diagrams and Dimensional Drawings

MOTOR STARTERS & VARIABLE SPEED DRIVES Variable speed drives

Installation Manual Updated May 2017

ABB Component Drives ACS55, 0.25 to 3 Hp

TEC Unit Conditioner Controller

Revolutionizing control wiring

TX-I/O Product Range. Description. Technical Specification Sheet Document No February 20, 2018

TEC Heat Pump Multi-Stage Controller. Control Applications. Accessories. Product Description. Product Numbers. Warning/Caution Notation

Description 1/8-7.5HP

TX-I/O Product Range. Features. Description. Technical Specification Sheet Document No January 24, 2007

VLT The Real Drive for HVAC. The VLT 6000 is a. totally new adjustable. frequency drive, with. control functions and. software designed solely

Low Voltage Drives. ABB component drives ACS55, 0.25 to 3 hp (0.18 to 2.2 kw) Catalog

Power 004=0.4kW 015=1.5kW. Delta Variable Frequency Drive

3 Uninterruptible Power Systems

SECTION SOLID-STATE REDUCED VOLTAGE STARTERS

Motor Controllers Variable Frequency AC Drives Type VariFlex 2 RVCF

ATS22D75S6U. Main. Range of product Altistart 22. Component name. Factory setting current. Utilisation category. IP degree of protection

S-Flex Enclosed drives

THERMOSTATS & CONTROLLERS

F510 Fan & Pump AC Drive

160 AA02SF1 AF DS-D17

FX Input/Output (I/O) Modules XM07 and XM14

The easy to use three-phase digital DC drive for regenerative and non-regenerative applications from HP

Motor Controllers AC Variable Frequency Drives Type Variflex 3 RVLF Advance

Transcription:

SED2 VFD NEMA Type 3R Bypass/Air Conditioner Description The NEMA Type 3R Bypass with Air Conditioner allows SED2 to be employed in a harsh environment. The SED2 is designed specifically for HVAC applications and supports a variety of digital and analog I/O and provides built-in PID features to control pumps and fans. For information on the family of SED2 VFDs, see the SED2 Variable Frequency Drives (154-042). Features Bypass Power 3-Contactor: Input, Output, and Bypass Overload protection in bypass mode. Step-down transformer with fused primary and secondary. Contactors electrically and mechanically interlocked. Drive test function. Complete electrical isolation of drive. Input Device Fused disconnect (optional). All doors are interlocked and padlockable. Circuit breaker. Reactor Options Line reactor mounted in bypass enclosure. Line reactor supplied separately (in NEMA Type 3R enclosure). Load reactor (in NEMA Type 3R enclosure) supplied separately. Air Conditioner NEMA Type 4. Cooling capacity of 1,000 to 20,000 BTUH. Digital temperature controller. Active condensate management system. Unit efficiency. Compressor Protection System. Bypass Control Auto Bypass Relay logic allows user to send the motor to bypass mode based on the drive s programmable relay. Enable Input Generally used for safety tie-ins; the motor will not operate the drive or bypass when open. Common Remote Start/Stop Can be used in both drive and bypass mode. Essential Services Mode Typically used for smoke purge; the motor goes to bypass regardless of the selected mode. No call to stop will have an effect, including open safety or stop commands. Only turning the power off or opening this contact will stop the motor. Bypass Door Mounted Control Devices 3-Contactor Units Drive-Off-Bypass selector Bypass pilot light Drive Test On-Off selector http://www.sbt.siemens.com/hvp/drives Siemens Industry, Inc.

Accessories SED2 NEMA Type 3R VFD & Bypass EMC Filter Assembly for Enclosure Size ABC, PN 994-830 SED2 NEMA Type 3R VFD & Bypass EMC Filter Assembly for Enclosure Size DEF, PN 994-831 NEMA Type 3R Reactor Enclosure, Small, PN 994-816 NEMA Type 3R Reactor Enclosure, Medium, PN 994-817 NEMA Type 3R Reactor Enclosure, Large, PN 994-818 Floor Mounting Kit, PN 994-809 Dimensions Figure 1. Enclosure ABC with Air Conditioner. Dimensions in Inches (mm). MOUNTING CLEARNANCE FOR PROPER AIR FLOW: 1. Leave 1 foot (305 mm) between the NEMA Type 3R Bypass and any adjacent solid structure not used for mounting purposes. 2. Leave 3 inches (76 mm) between the cabinet and the mounting surface for proper venting. 3. Leave 3 feet (914 mm) between the NEMA Type 3R bypass and any other Type 3R bypass or VFD. Enclosure with AC Frame Size Wt. Lb (kg) ABC 180 (82) NOTE: Exact weight will be affected by actual horsepower/ voltage and selected power options. Page 2 of 7 http://www.sbt.siemens.com/hvp/drives Siemens Industry, Inc.

Table 1. NEMA Type 3R Bypass and NEMA Type 3R Bypass with Air Conditioner Output Current Ratings (Amps) Per NEC Motor Tables. HP.5.75 1 1.5 2 3 5 7.5 10 15 20 25 30 40 50 60 75 100 125 208V 2.3 3.0 3.9 5.5 7.4 10.4 16.7 22 28 42 54 68 80 104 130 154 240V 2.2 3.0 3.9 5.5 6.8 9.6 15.2 22 28 42 54 68 80 104 130 154 480V 1.1 1.6 2.1 3.0 3.4 4.8 7.6 11 14 21 27 34 40 52 65 77 96 124 156 575V.9 1.3 1.4 2.1 2.7 3.9 6.1 9 11 17 22 27 32 41 52 62 77 99 125 NOTE: Drives are current rated devices. Verify that the listed ratings are the motor full load current rating. Wiring Diagrams Figure 2. NEMA Type 3R Bypass 120 Vac Control Circuit. Siemens Industry, Inc. http://www.sbt.siemens.com/hvp/drives Page 3 of 7

Figure 3. NEMA Type 3R Bypass Terminations. Page 4 of 7 http://www.sbt.siemens.com/hvp/drives Siemens Industry, Inc.

Figure 4. NEMA Type 3R Bypass with Air Conditioner Power Circuit. NOTES: 1. Branch circuit protection to be provided by installer, per UL508A, if not provided with drive. 2. For bypass operation modify these drive parameters: P0704 (0) and P0704 (1) = 3. 3. Control and communication wiring should be 300V UL minimum. 4. Communication wiring should be run with maximum separation possible from all other wiring. 5. Essential service mode operates the motor full speed (bypass) with no protection for the motor or system. 6. Ensure that automatic bypass will not damage the system before activating. 7. See Siemens Publication No. 125-3377 for proper fuse and wire sizes. 8. See Siemens Publication No. 125-3201 for SED2 VFD input/output signal wiring details. Siemens Industry, Inc. http://www.sbt.siemens.com/hvp/drives Page 5 of 7

NEMA Type 3R Bypass Specification Input Voltage (3 phase) Temperature Humidity Table 2. NEMA Type 3R Bypass with Air Conditioner Specifications. 208V, 3 AC ±10% 240V, 3 AC ±10% 480V, 3 AC ±10% 575V, 3 AC ±10% Operating: 14 F to 122 F ( 10 C to 50 C) Storage: 40 F to 158 F ( 40 C to 70 C) 0 to 100% rh Table 3. SED2 Drive Specifications. Description Drive Specification Description Input voltage and power ranges 200V and 230V to 240V, 3 AC ± 10% 1/2 hp to 60 hp (2.3 Amps to 154 Amps) (3 phase) 380V to 480V, 3 AC ± 10% 1/2 hp to 125 hp (1.2 Amps to 178 Amps) Amps 500V to 600V, 3 AC ± 10% 1 hp to 125 hp (2.3 Amps to 125 Amps) Input frequency 47 Hz to 63 Hz Output frequency 0 Hz to 150 Hz Power factor 0.9 total, 0.97 displacement VFD degree of efficiency 96% to 97% Switch-on current Less than nominal input current Auxiliary supply 24V Glavanically separated, unregulated auxiliary supply (18V to 32V) 100 ma Overload capacity 110% for 60 seconds Control method Linear, parabolic and programmable V/f; and flux current control low-power mode PWM frequency 2k Hz to 16k Hz (adjustable in 2k Hz increments) Fixed frequencies 15 programmable Skip frequency bands 4 programmable 0.01 Hz digital Setpoint resolution 0.01 Hz serial 10 bit analog Digital inputs (sink/source) 6: fully programmable and scalable isolated digital inputs, switchable Analog inputs 2: 0 to 10 Vdc, 0/4 ma to 20 ma, can also be configured as digital inputs or Ni 1000 input Relay outputs 2: configurable 30 Vdc/5A (resistive), 250 Vac 2A (inductive) Analog outputs 2: programmable (0/4 ma to 20 ma or 0V to 10 Vdc) Serial interface Protection level Temperature ranges Humidity Operational altitudes Protection features Standards CE conformity RS-485; Protocols: Siemens, P1 and Johnson, N2; Transmission rate: Up to 38.4k Baud IP20: NEMA Type 1 (with protective shield and gland plate installed) IP54: NEMA Type 12 (400V and 500V series only) Operating: 14 F to 104 F ( 10 C to 40 C) Storage: 40 F to 158 F ( 40 C to 70 C) 95% rh, non-condensing Up to 3280 ft (1000 m) above sea level without de-rating Under-voltage, Over-voltage, Overload, Ground fault, Short circuit, Stall prevention, Locked motor, Motor overtemperature l 2 t PTC, Over-temperature, Parameter PIN protection. UL, cul Conformity with EC Low Voltage Directive 73/23/EEC Page 6 of 7 http://www.sbt.siemens.com/hvp/drives Siemens Industry, Inc.

Table 4. Order Worksheet. Item Qty. Designation Part Number Description Information in this publication is based on current specifications. The company reserves the right to make changes in specifications and models as design improvements are introduced. Product or company names mentioned herein may be the trademarks of their respective owners. 2009 Siemens Industry, Inc. Siemens Industry, Inc. Building Technologies Division 1000 Deerfield Parkway Buffalo Grove, IL 60089 + 1 847-215-1000 Your feedback is important to us. If you have comments about this document, please send them to sbt_technical.editor.us.sbt@siemens.com. Printed in the USA Page 7 of 7