Differential Pressure Sensor

Similar documents
Suction Pressure Sensor

Pressure Transducer Model PR-264

Low Pressure Transducer Model PR-274/275

Model HU-224/225. Technical Information TI.224/ Humidity Transduce r FOR ADDITIONAL INFORMATION SEE HU-224/225 DATA SHEET

User s Guide. OM-CP-HITEMP140-M12 High Temperature Data Logger with an M12 Probe Connector

Xxxxx Xxxxxx Bridge / Strain Gauge Data Logger

User s Guide. OM-CP-PRHTEMP2000 Pressure, Humidity and Temperature Data Logger with LCD

Xxxxx Xxxxxx OM-CP-QUADVOLT. OM-CP-OCTVOLT 8-Channel Low Level DC Voltage Data Logger. 4-Channel Low Level DC Voltage Data Logger INSTRUCTION SHEET

M5100 Heavy Industrial Pressure Transducer

High Temperature Data Logger

User s Guide TXDIN1700. Universal DIN Rail. Shop online at omega.com SM. For latest product manuals:

TPE 1464 Series Pressure Transducer

M7100 Pressure Transducer

Xxxxx Xxxxxx DC Voltage Data Logger

LCI User Manual mantracourt.com

User s Guide CS8DPT SERIES. Benchtop Controllers. Shop online at omega.com. For latest product manuals:

User s Guide OM-SGD-28-M. Shop online at omega.com. Smart Graphics Display. For latest product manuals:

SP6R Level Controller Operation Manual

U7100 Pressure Transducer

Model 206 Operating Instructions. Setra Systems, Inc. 159 Swanson Road, Boxborough, MA

P027 Series Pressure Transducer Installation & Operation Manual

HIGH ACCURACY PRESSURE TRANSDUCERS

EASON TECHNOLOGY. IO8 & IO24 Break-Out Module

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

User s Guide RDXL6SD-USB. Temperature Data Logger with USB. Shop online at omega.com

FMA-7400/7500 Series Configurator

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

Automated Tuner System Power Distribution Hub

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

DTG for Retorts. Style FH3 or FH4

LCI Load Cell Junction Box with Fault Monitor

Tempco Instruction Manual

EPWR Series. RoHS. Product Description. Available Products. Installation Instructions 01

Installation Guide. Setra Systems Model 3100/3200 Pressure Transducer

User s Guide. Series. Communication Manual. Shop online at omega.com SM. For latest product manuals:

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

User's Guide. Phase Sequence and Motor Rotation Tester Model

B34 SR & SN Medium Duty Commercial&Industrial Regulator

MicroLink Installation Operation & Specifications Manual. General Description

Differential Liquid/Gas Pressure Transmitter

User's Guide. MiniTec TM Series Model MN25 MultiMeter

87421/22A Power Supply. Operating and Service Manual

User's Guide. Extech AM A AC Analog Clamp Meter

OPERATING MANUAL LOW-VOLTAGE DISCONNECT PANELS LVD400 & LVD600 SERIES

Installation Operation & Specifications Manual. General Description

Low Pressure Digital & Analog Sensor

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

E2EY. A Proximity Sensor for Aluminum, Brass and Other Non-ferrous Metals. Iron Is Not Detected. Aluminum-detecting Proximity Sensor

Model Number Structure

American Power Design, Inc.

PS-AULDP Series. Overview. Applications. Features & Benefits. Datasheet. Ultra Low Air Differential Pressure Transmitters

Digital Lighting Systems, Inc.

User s Guide. OM-CP-HITEMP140X2 High Temperature Dual Probe Data Logger Series

HI ma Simulator

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

DCM Digital Control Modules

Miniature Overhead Stirrer

KOBOLD PDA Series Digital Pressure Transmitter

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

User s Guide. DRSL-LPO Series. DIN Rail Loop Powered Isolators. Shop online at omega.com

HI ma Simulator

USER S MANUAL ENTITY. Energy Meter TRINITY. Entity Operational Manual

MODEL 8000MP LEVEL SENSOR

TM0-1 AMPLIFIER / CONDITIONER MODULE OPERATORS MANUAL. Transducer Techniques R

Model CR103J. DC Current and Voltage Calibrator/Standard ±0.01µA to ± mA ±0.1µV to ± V. Operating Manual

Name No. of I/O points Model Safety inputs: 12, test outputs: 4

Solid State Relays with Failure Detection Function

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

E2KQ-X. Fluororesin-coated Capacitive Sensor with Sensitivity Adjuster. Chemical-resistant Proximity Sensor. Ordering Information

Model Number Structure

R & D SPECIALTIES SERIES 100 RO CONTROLLER USERS MANUAL. 2004, by R & D Specialties, Inc. All Rights Reserved.

IRB-MON UNIVERSAL SAFETY PHOTOEYE OPERATING UL MONITORED DEVICE

S82S (3/7.5-W Models)

CK3W-PD048 CSM_CK3W-PD048_DS_E_DITA_1_2

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

ES-600 Ozone Controller Operation Manual

SERVICE MANUAL MODEL SSW-520-F

Instruction and Operation Manual

LevCon. Liquid Level Indicator / Controller DIAL-SJE ( )

VELOCICALC Air Velocity Meter

RS-485 Fiber-Optic Link RS-485 to Multi-Mode Fiber-Optic converter ST Fiber Connectors DIN Rail Mount

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

IRB-MON O P E R A T I N G I N S T R U C T I O N S UNIVERSAL SAFETY PHOTOEYE U L M O N I T O R E D DEVICE

TABLE OF CONTENTS INTRODUCTION. 3. Analog Input Analog Output Digital Input Digital Output OPERATIONAL DESCRIPITON.. 7 PROGRAMMING AND INITIAL SETUP.

VIP-812A DUAL NETWORKED STATION PORT

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

MR52 READER INTERFACE

Model Number Structure

User's Guide. Model High Precision Quad Output DC Power Supply

OPERATION MANUAL BO BLASTER S OHMMETER

Model SST Slimline Submersible Pressure Transmitter

Surge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

USER MANUAL CCHP-6000-XX 6kJ/s Capacitor Charging Power Supply

DP-CALC MICROMANOMETER MODEL 5825

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

Model 8702 DP-CALC Micromanometer

Proliphix EPA-60 Installation Guide

PD10. Pulse Divider Instructions PROUDLY MADE IN THE USA

Eco Sensors OZONE CONTROLLER Model OS-6 Instructions for Use. General and New Features

Transcription:

Differential Pressure Sensor Model RoHS 100% solid-state fused silicon pressure sensors Rugged, leakproof 17-4 PH stainless steel monolithic pressure cavities with no welds, O-rings, seams, or bonds Wide 12-40 VDC/12-35 VAC unregulated supply voltage Three temperature-compensated humidity output versions: 4-20 ma 2-wire or 0-5 VDC/ 0-10 VDC NIST traceable calibration Rugged NEMA-1 (IP-30) enclosure Short circuit and reverse polarity protected Conforms to EMC and RoHS standards The incorporates sophisticated integrated circuits and new fused silicon monolithic cavity pressure sensors to not only provide a high level, fully conditioned and temperature compensated output, but also to offer up to six (6) pressure ranges. The 17-4 PH SS monolithic pressure cavity not only provides media compatibility for most of the applications, but also offers a leakproof solution for today s environmentally conscious customers. Three industry standard output versions are available: 4-20 ma 2-wire loop or 0-5 VDC/0-10 VDC. A wide 12-40 VDC or 12-35 VAC unregulated supply voltage and a broad 0 F 180 F compensated temperature range ensures compatibility to most of the applications. A rugged NEMA-1 (IP-30) enclosure, fully temperature compensated NIST traceable accuracy and a liberal five year warranty are some of the features which make the the industry s most reliable, rugged, and economical pressure sensor. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876

The sensing elements are 100% solid-state piezoresistive silicon strain gauge fused directly onto the 17-4 PH SS monolithic pressure cavity. The pressure cavity is machined out of a solid rod and does not incorporate any welds, seams, or bonds. In this way, the sensor not only offers excellent linearity, repeatability, and sensitivity, but also exhibits negligible hysteresis and withstands significant overpressure without zero shift. The monolithic nature of the cavity ensures not only leakproof operation but also enhances the overpressure and burst pressure specifications. The pressure cavity design incorporates novel techniques to isolate the fused silicon sensing element from installation related stress thereby ensuring zero integrity. The 17-4 PH SS offers excellent media compatibility to most of the industrial and commercial applications. The incorporates sophisticated integrated circuits to provide a high level, fully conditioned and temperature compensated output. MAMAC has unique Double D design stainless steel ports. The sensing elements are welded to the ports and both have stainless steel isolation between the sensor and media. In HVAC applications, thermal shock has always been a problem. A rapid change in temperature may cause epoxy seals to break and 0-rings to blow out. The coefficient of thermal expansion of epoxy, neoprene and Buna-N is not the same as steel. A rapid temperature change will cause the ports and sensor to expand and the dissimilar coefficient of thermal expansion will result in the epoxy seals breaking and the 0-rings loosening resulting in a leak. The with welded construction and all stainless steel pressure cavities performs reliably under thermal shock conditions. Another problem well known in our industry is that if a bulkhead fitting is used to secure the sensor to the enclosure, overtightening the fitting will result in the sensor twisting and the lead wires may break or the calibration may shift. To eliminate this problem, our engineers have incorporated a unique Double D designport which is secured to the enclosure with two retaining E-rings. The Double D shape of the ports eliminates any possibility of the sensor twisting due to overtightening and the E-rings provide a rugged means to securely attach the sensing elements to the enclosure. The ports have wrench flats on each side to assist in tightening the pipe fitting to the ports. The dual all stainless steel pressure cavities enable our to be compatible to all media encountered in HVAC applications including freon, ammonia, steam, chilled/hot water, among others. This feature enables one unit to be compatible for all applications. On VDC output units, two options are available: outputs 0-5 or 0-10 VDC, and dual unregulated supply voltages 12-35 VAC or 12-40 VDC. The ma output units can function over a wide unregulated supply voltage range of 12-40 VDC without any affect on calibration or performance. The unit has reverse polarity protection build in. As a result, it is next to impossible to damage the unit by mis-wiring. By using sophisticated low drop-out voltage regulators and CMOS integrated circuits, the ma output unit can drive very high output impedance. In fact, with only 12 VDC supply, the unit can drive 400 ohms. At 40 VDC, the unit is capable of handling up to 3000 ohms load. In this way, the output loop can be tied in series to multiple controllers, indicators and other devices without degrading the performance. The is shipped fully calibrated and tested with a minimum 24 hours burn-in to provide trouble free start up. Easily accessible zero and span trimmers are provided if field calibration is needed. The has a unique 16 gage steel NEMA 1 enclosure designed to facilitate installation and provide easily accessible wiring termination. The pressure ports have industry standard 1/8-inch NPT process connection to accommodate any pipe fitting. With more than 4 output and supply voltage options and 6 pressure ranges, our not only guarantees compatibility to all control systems but also is the most reliable, stable and versatile differential pressure sensor available. 2

SPECIFICATIONS: : Accuracy*: ± 1% FS Overpressure: 300% of rated range Burst Pressure: 500% of rated range Max Static Pressure: 200% of DP range Supply Voltage: 12-40 VDC 12-35VAC (VDC output units only) Supply Current: VDC Units 10 ma max. ma Units 20 ma max. Load Impedance: 3K ohms max. at 40 VDC (ma output units) 1K ohms min. (VDC output units) Enclosure: 16 gage steel - NEMA-1 Finish: Baked on Enamel-PMS2GR88B *Includes non-linearity, hysteresis and non-repeatability U.S. PATENT NO. 6484587 Compensated Temp Range: 0 F 180 F (-18 C 82 C) T. C. Error: ±0.025%/ F (.03%/ C) Media Compatibility: Liquid/gases compatible to 316L stainless steel Port Connection: 1/8" NPT Environmental: 10 90%RH Non-Condensing Termination: Unpluggable screw terminal block Wire Size: 12 Ga max. Weight:1.7 lbs. (.75 kg) CONFORMANCE & TESTING: RoHS Compliant EMC Testing: BS EN 55022:1998, BS EN 55024:1998, EN 61000-3-3, EN 61000-4-2, EN 61000-4-3, EN 61000-4-4, EN 61000-4-5, EN 61000-4-6, EN 61000-4-11 ORDERING INFORMATION: *Available with 24VDC supply voltage only. **Custom ranges are available between 0-20 psid and 0-300 psid Example: -2-3-A-1-2-B: 0-5 VDC Output with 0-50 psid Pressure Range and 24 VDC Supply Voltage Caution: Do not use on oxygen service, in explosive / hazardous environment or with flammable/combustible media. 3

0.875" (22 mm) 3.25" (82 mm) 3.50" (89 mm) 2.25" (57 mm) 0.75" (19 mm) 5.00" (127 mm ) 2.00" (51 mm) 2.00" (51 mm) 4

MAMAC Systems is the leading global manufacturer of sensors, transducers, control peripherals and web browser based IP appliances. MAMAC products are used for HVAC and environmental controls, remote monitoring, alarming, energy metering and industrial automation. All MAMAC products are manufactured in the USA. WARRANTY: MAMAC Systems, Inc. and its subsidiaries (hereinafter referred to as MAMAC Systems) warrants its products to be free of defects in material and workmanship for a period of five (5) years from date of shipment. If a unit is malfunctioning, it must be returned to the factory for evaluation. A return authorization number (RMA) will be issued by the customer service department and this number must be written or prominently displayed on the shipping boxes and all related documents. The defective part should be shipped freight pre-paid to the factory. Upon examination by MAMAC Systems, if the unit is found to be defective, it will be repaired or replaced at no charge to the customer. However, this warranty is void if the unit shows evidence of being tampered with, damaged during installation, misapplied, misused, or used in any other operating condition outside of the unit s published specifications. MAMAC Systems makes no other warranties or representations of any kind whatsoever, expressed or implied, except that of title. All implied warranties including any warranty of merchantability and fitness for a particular purpose are hereby disclaimed. User is responsible to determine suitability for intended use. LIMITATIONS OF LIABILITY: The remedies of buyer set forth herein are exclusive and the total liability of MAMAC Systems with respect to this order, whether based on contract, warranty, negligence, indemnification, strict liability or otherwise, shall not exceed the purchase price of the product upon which liability is based. In no event shall MAMAC Systems be liable for consequential, incidental or special damages. MAMAC Systems reserves the right to change any specifications without notice to improve performance, reliability, or function of our products. Every precaution for accuracy has been taken in the preparation of this manual, however, MAMAC Systems neither assumes responsibility for any omissions or errors that may appear nor assumes liability for any damages that result from the use of the product in accordance with the information contained in the manual. 8189 Century Boulevard Minneapolis, MN 55317-8002 USA 800-843-5116 952-556-4900 Fax 952-556-4997 sales@mamacsys.com www.mamacsys.com 4200 Waterside Centre Solihull Parkway Birmingham West Midlands B37 7YN United Kingdom 01384-271113 Fax 01384-271114 1 Fullerton Road #02-01 One Fullerton Singapore 049213 65-31581826 Fax 65-31581826 4 Armiger Court, Unit 2 Adelaide S.A. 5088 Australia 08-8395-4333 Fax 08-8395-4433 675 Cochrane Drive East Tower 6th Floor Toronto Ontario L3R 0B8 Canada 905-474-9215 Fax 905-474-0876