Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Similar documents
Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X

Energy Management BUS Adapter Type VMU-B 01

Energy Management BUS Adapter Type VMU-B

Energy Management Energy Transducer Type ET112

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

Energy Management Modular Energy meters Type EM2-96

Energy Management Modular Universal Utility Meter and Power Analyzer Type WM24-96

EM271. Multi-channel power analyzer. Benefits. Description

EM270. Multi-channel power analyzer. Benefits. Description

protocol can be used. The SB2WEB24 is also equipped with an RS485 port for communication

VMU-MC and VMU-OC. Pulse concentrator. Benefits. Description

WM20. Power analyzer for three-phase systems. Benefits. Description

Digital Panel Meters Modular signal s conditioner Type USC-DIN

smart-house Controller Central Unit Module Type SH2WEB24

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/O

MIC-2 MKII, Multi-instrument DATA SHEET

RE17LAMW on-delay timing relay - 1 s..100 h V AC/ DC - solid state output

RE17LAMW on-delay timing relay - 1 s..100 h V AC/DC - solid state output

SH2WEB24. Central unit module. Benefits. Description

Digital Panel Meters Modular Indicator and Controller Type UDM35

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

RE17LCBM off-delay timing relay - control - 1 s..100 h V - solid state output

Multichannel power analyzer for single, two and three-phase systems

Communications & Networking

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Programmable Relay ZEN V2 Units

RE22R2CMR Off-delay Timing Relay s 300h V AC/DC - 2C/O

SA2WEB24. Central unit module. Benefits. Description

RM35JA32MR Current control relay 0.15A 15A, 2 C/O

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

SB2WEB24. SB2WEB BACnet Controller. Benefits. Description

MIC-2 Multi-instrument DATA SHEET

RE22R1QMQ star-delta timing relay - 230VAC/440VAC - 1 C/ O

RE22R2KMR Off-delay Timing Relay s 10min V AC/DC - 2C/O

Digital Panel Meters Modular Indicator and Controller Type USC-DIN

Power Meter PowerMonitor 500

RE22R2QGMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

RM22LA32MR Level control relay RM22-L V AC/DC - 2 C/O

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

RE22R2AMR On-delay Timing Relay s 300h V AC/DC - 2C/O

02/11/2015

VMU-C EM system. Integrated modular system to monitor conventional energy. Benefits. Description

MCX08M2 Programmable controller

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

LBVR1718. Description. Features channel paperless recorder

02/11/2015

RE48ATM12MW on-delay timing relay s..300 h V AC - 2 OC

Digital Panel Meters Modular Indicator and Controller Type UDM40

RE22R1AMR On-delay Timing Relay s 300h V AC/DC - 1C/O

Single-phase ( V) voltage monitoring: Undervoltage Overvoltage Window mode (overvoltage + undervoltage) Voltage fault memory selectable

Pulse concentrator, 12 inputs, 4 mod. DIN, with RS485 port

RE11RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE22R2QTMR Star-Delta Timing Relay s 300h V AC/DC - 2C/O

02/11/2015

Energy meters Single phase electrical energy meters WM1-6 / WM1M6

Zelio Count - Counters RC87610

08/07/2015

ProData DATA LOGGER. Chapter 03 ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Modbus-Ethernet gateway. Thermistor input.

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Output Voltage* (nom.)(adjustable)

Voltage Transducer UMT516 / MT516

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

Contact protection relay

TM3TM3 module TM3-2 temperature inputs and 1 analog output

General information. Display. Supply voltage

ABB Instrumentation. Specification DataFile COMMANDER 100. the-easy-to use 1. /8 DIN controller with extensive application capabilities

Mini Energy Web Server

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

Process displays For current and voltage

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Voltage Current Front-mounting bracket

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

ProData data logger. Ethernet. Pulse inputs and Pulse outputs. Thermistor input. Modbus-Ethernet gateway. Memory 32 MB. Threshold value monitoring

TM3AI4 module TM3-4 analog inputs

General information. Display. Supply voltage. Input current. Encoder supply. Output current

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

RE Product data sheet Characteristics. time delay relay for star-delta starter ms - 230/380 V AC - 1 contact. Main.

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

RE9RA21MW7 off-delay timing relay s V AC -

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

PCD3.C90. Date Modification Asked by: Version E/A Bus Connector PCD2.K106 change to PCD3.K106 Müller.R 1.1

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage. Input current

InteliLite MRS17 Click Here to Learn More

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

General information. Display. Supply voltage. Input current. Encoder supply. Output current

RE7RB13MW adjustable off-delay timing relay s V AC DC - 2OC

RE Product data sheet Characteristics. universal plug-in timing relay - flashing s..60 mn V AC - 2 OC. Main.

General information. Display. Supply voltage. Input current

General information. Display. Supply voltage

Strain Gauge Converter

Transcription:

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit. VMU-E, DC energy analysis unit Instantaneous variables: V, A, W Instantaneous variables data format: 4-DGTs Energy measurements: kwh Energies data format: 6 DGT Accuracy: class 1 (kwh), ±0.5 RDG (current/voltage) Direct DC current measurement up to 20A External shunt DC current measurement up to 1000A External 10V DC current sensor measurement up to 1000 A Direct DC voltage measurement up to 400V Auxiliary power supply from VMU-X unit Dimensions: 1-DIN module Protection degree (front): IP40 VMU-E Product Description DC energy analyzer unit with built-in 6 digit display and programming push-button, particularly indicated for DC current, voltage, power and energy metering. Direct connection up to 20A and with external shunt or current sensor (e.g. Hall effect), with 10 V output) up to 1000A. Moreover the unit is provided with an auxiliary serial communication bus which is connected to the VMU-X unit so to provide an RS485 communication port. Housing for DIN-rail mounting, IP40 (front) protection degree. How to order Model Range code Internal bus Option VMU-E AV00 XX X X Type Selection Range code Internal bus Option AV00: 400V DC - 20A (Direct connection) or external shunt input for currents up 1000A AV10: 400V DC - External 10V DC current sensor for currents up 1000A XX: self-power supply from VMU-X unit X: internal bus compatible only to VMU-X module X: none Specifications are subject to change without notice VMU X E DS ENG 061217 1

VMU-X, universal power supply and RS485 communication unit or static digital output module for VMU-E unit RS485 communication port (Modbus) One digital output for pulse retransmission proportional to the energy being measured or for alarm control 38 to 265 VAC/DC power supply input Dimensions: 1-DIN module Protection degree (front): IP40 VMU-X Product Description Universal power supply module suitable to be used in combination to VMU-E unit. In order to improve the communication capability of VMU-E unit, VMU-X can be provided with either an RS485 communication port or with a static output. Housing for DIN-rail mounting, IP40 (front) protection degree. How to order Model Communication Option VMU-X U S1 X Type Selection Communication Option (*) as standard. U: from 38 to 265VAC/ DC (*) S1: RS485 Modbus (*) D1: static digital output for pulse retransmission or alarm control (*) X: none 2 Specifications are subject to change without notice VMU X E DS ENG 061217

VMU-E Display and LED specifications Display Type Information read-out LED Type Status and colour 1 line (max: 6-DGT) LCD, h 7mm From 4 to 6-DGT depending on the information. Dual colour Red blinking light: energy consumption; 1000 pulses/ kwh (Max Frequency 16 Hz). Red steady light: alarm detected (it has the priority on any other condition: energy consumption or communication). Green blinking light: the communication on the RS485 bus is working. Note: in case of energy counting or communication condition, the LED alternates its colour from red to green. VMU-X LED specification LED Type Single colour Colour Green: the power supply is ON. VMU-E input specifications Rated inputs Current input Current direct conn. range Current external shunt conn. range DC current external sensor connection Voltage range Accuracy Current direct conn. range Start up current Current external shunt conn. Start up current DC current external sensor range: 1 (internal shunt) From 0 to 20A DC From 0 to 120mV DC From 0 to 12V DC From 0 to 400V DC (@25 C ±5 C, R.H. 60%) ±(0.5%RDG+2 DGT) from 0.05A to 20A DC 50mA DC ±(0.5%RDG+2 DGT) from 0.1mV to 120mV DC 0.1mV DC +/-(0.5%RDG + 2DGT) from 0.01V to 12VDC Start up current: equivalent to 0.01V Voltage Start up voltage Power Energy Temperature drift Measurement sampling time Key-pad ±(0.5%RDG+2 DGT) from 10V to 400V DC 10V DC ±(1% RDG+ 2DGT) ±(1% RDG) 200ppm/ C 150 ms 1 push-button for variable scrolling and programming of the instrument working parameters. Display read-out Instantaneous variables 4-DGT (V, A, W) Resolution 0.1V; 0.01A; 0.01kW (for more details see VMU-E set of variables) Energy Total: 6-DGT (0.1KWh) Max. and Min. indication Input impedance Voltage Current direct connection Current external shunt conn. DC current external sensor connection: Voltage Overloads Continuous For 1s Current Overloads Direct connection Continuous For 1s External shunt connection Continuous For 1s DC current external sensor connection Continuous For 1s See VMU-E set of variables = 5MΩ < 0.006Ω+ @ 0.5 Nm (screw terminal torque). > 30kΩ > 300 kohm 500V 800V 20A DC 100A DC max 10V DC 20V DC max 50 V DC 100 V DC max Specifications are subject to change without notice VMU X E DS ENG 061217 3

VMU-X Output specifications RS485 Type Connections Addresses Protocol Data (bidirectional) Dynamic (reading only) Static (writing only) Data format Multidrop, bidirectional (static and dynamic variables) 2-wire. Max. distance 1000m 247, selectable by means of the front push-button MODBUS/JBUS (RTU) All variables, see table List of the variables that can be displayed and connected to All the configuration parameters. 1 start bit, 8 data bit, no parity,1 stop bit Baud-rate Selectable: 9600, 19200, 38400, 115200 bits/s Parity: none Driver input capability Special functions Insulation 1/5 unit load. Maximum 160 transceivers on the same bus. None See the table Insulation between inputs and outputs Digital output Number of outputs 1 Purpose Selectable either for pulse transmission proportional to the energy being measured or for alarm control on selected variable. Type Static: opto-mosfet; Load V ON 2.5 VAC/DC max. 70 ma, V OFF 260 VAC/DC max. Pulse output Pulse duration Alarm output Operating mode Alarm modes Controlled variables Set-point adjustment Hysteresis On-time delay Off-time delay Min. response time Insulation 100ms < 120msec (ON), 120ms (OFF) With digital output: real alarm; with RS485: virtual alarm. Up alarm or down alarm W, V, A (see the table List of the variables that can be displayed and connected to ) Programmable on all the measuring range (see VMU-E set of variables ) Programmable on all the measuring range (see VMU-E set of variables ) 0 to 9999s (166min) 0 to 9999s (166min) 1s, set-point on-time delay: 0 s See the table Insulation between inputs and outputs 4 Specifications are subject to change without notice VMU X E DS ENG 061217

Main functions Displaying 1 variable per page. See ( VMU-E set of variables ) Password Numeric code of max. 4 digits; 2 protection levels of the programming data: 1st level Password 0, no protection; 2nd level Password from 1 to 9999, all data are protected Energy reset By means of the front push-button Scaling of external shunt current input Input scale Display scale Programmable from 0 to 120mV DC Programmable from 0 to 1000A DC Insulation between inputs and outputs Module VMU-E VMU-X Type of input/output Measuring input Power Supply RS485 port Static output VMU-E Measuring input - 4kV 4kV 4kV Power Supply 4kV - 4kV 4kV VMU-X RS485 port 4kV 4kV - 4kV Static output 4kV 4kV 4kV - Specifications are subject to change without notice VMU X E DS ENG 061217 5

General specifications Operating temperature Storage temperature -25 to +55 C (-13 F to 131 F) (R.H. from 0 to 90% non-condensing @ 40 C) -30 to +70 C (-22 F to 158 F) (R.H. < 90% noncondensing @ 40 C) Installation category Cat. III (IEC 60664, EN60664) Insulation (for 1 minute) Dielectric strength Noise rejection CMRR EMC (Immunity) Electrostatic discharges Immunity to irradiated Electromagnetic fields Immunity to Burst See table Insulation between inputs and outputs 4000 VAC RMS for 1 minute >65 db, 45 to 65 Hz According to EN61000-6-2 EN61000-4-2: 8kV air discharge, 4kV contact; EN61000-4-3: 10V/m from 80 to 3000MHz; EN61000-4-4: 4kV on power lines, 2kV on single lines; Immunity to conducted disturbances Surge EN61000-4-6: 10V from 150KHz to 80MHz; EN61000-4-5: 2kV on power supply; 4kV on current inputs. EMC (Emission) According to EN61000-6-3 Radio frequency suppression According to CISPR 22 Standard compliance Safety Approvals Housing Dimensions (WxHxD) Material Mounting Protection degree Front Screw terminals IEC60664, IEC61010-1 EN60664, EN61010-1 CE 17.5 x 90 x 67 mm Noryl, self-extinguishing: UL 94 V-0 DIN-rail IP40 IP20 VMU-E connections Connections Screw-type Cable cross-section area Current, voltage Min. 2.5 mm 2, max 6 mm 2 in case of flexible wire, Max. 10 mm 2 in case of rigid wire. Min./Max. screws tightening torque: 0.5 Nm / 1.1 Nm Current shunt Max 1.5 mm 2, Min./Max. screws tightening torque: 0.4 Nm / 0.8 Nm Screw terminal purposes 6/10 mm 2 4 screw terminals: 1 for current input, 1 for current output 2 voltage reference 1.5 mm 2 2 screw terminals: external shunt or DC current sensor input Weight Approx. 100 g (packing included) VMU-X connections Connections Cable cross-section area Screw-type 1.5 mm 2 max. Min./Max. screws tightening torque: 0.4 Nm / 0.8 Nm Screw terminal purposes 1.5 mm 2 3 screw terminals used for RS485 port. 2 screw termi- Weight nals used for static output, 2 screw terminals used for power supply Approx. 100 g (packing included) 6 Specifications are subject to change without notice VMU X E DS ENG 061217

VMU-E power supply specifications Self-power supplied through the VMU-X unit VMU-X power supply specifications 38 to 265 VAC/DC Power consumption 1.5W, 3VA (VMU-X + VMU- E) VMU-E set of variables No. Variables Display read-out Notes 1 V 0.0 to 999.9 2 A 0.0 to 20.00 In case of external shunt input: 0.0 to 999.9 3 kw 0.0 to 99.99 In case of external shunt input: 0.0 to 999.9 4 kwh 0.0 to 99999.9 In case of external shunt input: 0.0 to 999999 List of the variables that can be displayed and connected to RS485 communication port Alarms No Variable Display RS485 Alarm Reset Notes 1 V Yes Yes Yes No 2 V min No Yes No Yes The value is saved into E 2 PROM 3 V max No Yes No Yes The value is saved into E 2 PROM 4 A Yes Yes Yes No 5 A min No Yes No Yes The value is saved into E 2 PROM 6 A max No Yes No Yes The value is saved into E 2 PROM 7 kw Yes Yes Yes No 8 kw min No Yes No Yes The value is saved into E 2 PROM 9 kw max No Yes No Yes The value is saved into E 2 PROM 10 kwh Yes Yes No Yes The value is saved into E 2 PROM 11 Alarm No Yes Yes No There is only one alarm which can be linked to the availale instantaneous variables Specifications are subject to change without notice VMU X E DS ENG 061217 7

VMU-E connections Measuring input (AV00) Fig. 1 Measuring input (AV00) Fig. 2 1 4 5 3 1 2 3 External SHUNT connection DIRECT connection (20 ADC) Measuring input (AV10) Fig. 3 Measuring input (AV10) Fig. 4 3 1 4 5 1 2 3 External SENSOR connection (12 V dc) DIRECT connection (20 A dc) 8 Specifications are subject to change without notice VMU X E DS ENG 061217

VMU-X connections Fig. 1 Digital output Fig. 2 A1 A2 VMU-X D1 1 2 38 to 265 VAC/DC RS485 port Fig. 3 VMU-X S1 B A B A G G Specifications are subject to change without notice VMU X E DS ENG 061217 9

VMU-E Frontal panel description 1. Push button. To program the configuration parameters and to scroll the variables. One key function: short time pushbutton click: variable scroll or parameter increasing. Long time pushbutton click: programming procedure entering, parameter selection confirmation. 3 2 1 4 2. LED. Red blinking light: energy consumption; 1000 pulses/kwh (Max Frequency 16 Hz). Red steady light: alarm detected (it has the priority on any other condition: energy consumption or communication). Green blinking light: the communication on the RS485 bus is working. Note: in case of energy counting or communication condition, the LED alternates its colour from red to green. 3. Display. LCD-type with alphanumeric indications to: - display the configuration parameters; - display some measured variables. 4. Screw terminals. For measuring input connections. VMU-X Frontal panel description 1. LED Green: the power supply is ON. 2. Screw terminals For power supply and either digital output or communication port connections. 1 2 10 Specifications are subject to change without notice VMU X E DS ENG 061217

VMU-E Dimensions and panel cut-out 18mm 45.5mm VMU-X Dimensions and panel cut-out 18mm 45.5mm Specifications are subject to change without notice VMU X E DS ENG 061217 11