Model Number Structure

Similar documents
Model Number Structure

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Solid State Relays with Failure Detection Function

Model Number Structure

Model Number Structure

Model Number Structure

(Applicable output load) to 264 (see note 2) (see note 1) (2Aat75to264VAC) G3R-202SLN-US PCB Yes 2 A at 100 to 120 VDC. (2 A at 75 to 132 VDC)

G3NE. Model Number Structure. Solid State Relays. Model Number Legend. Compact, Low-cost, SSR Switching 5 to 20 A

Model Number Structure

G3F/G3FD. Model Number Structure. Solid State Relays Model Number Legend

G3H/G3HD. Model Number Structure. Solid State Relays Model Number Legend

G3B/G3BD. Model Number Structure. Ordering Information. Solid State Relays Model Number Legend. List of Models

G3NE. Ordering Information. Solid State Relay. Compact, Low-cost, SSR Switching 5to20A J ACCESSORIES (ORDER SEPARATELY) Solid State Relay G3NE

Bulletin 700-SH Solid-State Relays. Overview/Product Selection. Bulletin 700-SH. Product Selection

Safety Relay Unit (I/O Unit Type)

Solid-state Timer H3YN

Note: Each relay to be mounted must incorporate a coil that has proper specifications within the maximum rated voltage range.

Thread length (overall length) material

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

SRT2-ROC08, SRT2-ROC16

Model Number Structure

Inductive Proximity Sensor

(75 to 264 VAC) 12 VDC 24 VDC No 5 VDC G3MC-202PL 12 VDC 24 VDC

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Combine Relays and P7TF Block Bases to match your application requirements. Use the table below to configure Relay Blocks.

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

4 mm. 8 mm. Proximity Sensor. Sensing head Sensing distance Output configuration Part Number M18 Shielded 4 mm DC 3-wire PNP-NO E2EZ-X4B1 M30

G3FM. Model Number Structure. Ordering Information. Solid State Relays. Model Number Legend. List of Models

Inductive Proximity Sensor

Self-Powered Counters H7EC

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Switching Power Supply

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Switching Power Supply S82J. Ordering Information. Open-Frame, Covered-Frame, or Enclosed-Frame Type with Capacity Up to 600 W

Voltage Current Front-mounting bracket

Conductive Level Controller

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Terminal Relay types. Common note. Terminal Relay/Terminal SSR Mounted relays. Compact Terminal Relays/Terminal SSRs with four outputs

S8VE (60/90/120/180/240-W Models)

Model Number Structure

G3S4-A 5 VDC 12 VDC 24 VDC 0.6 A at 75 to 264 VAC (See note 1.) G3S4-A1 5 VDC 12 VDC 24 VDC Yes G3SD-Z01P-PD 1 A at 3 to 26 VDC (See note 2.

H3CR-H. Solid-state Power OFF-delay Timer. Ordering Information. DIN 48 x 48-mm Solid-state Power OFF-delay Timer

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

Solid-state Counter. Power supply Output No voltage input (short/open circuit) Voltage input (high/low voltage) 30 cps 1 kcps 30 cps 1 kcps AC

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

Model Number Structure

Ordering Information. I/O Relay G7T. Model Number Legend Slim-styled I/O Relay Saves Space in Panel

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

MOS FET Relay. Ordering Information. Application Examples G3VM- XN(F)/4N(F)

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

Model Number Structure. Power Controllers G3PX. Single-phase Models. Model Number Legend

Solid-State Counter/Timer

Special-purpose Basic Switch

Appearance Size (mm) Power supply voltage Model (W H D) 100 to 240 VAC K3SC to 240 VAC

Switch Mode Power Supply S8VT 120/240/480/960 W Models

Setting method Indication Control Output Model method mode Thermocouple (with sensor burnout detection circuit)

NPN output PNP output Cord connection Cord length: 2 m Through-beam 7 m Light-ON. 2 m. (selectable by wiring) Diffuse reflective 0.

Ordering Information. Three-phase Input Switch Mode Power Supply S8VT S8VT. Model Number Legend

PRODUCT SPECIFICATION. PC Board Relays. Series.

Sensing method Appearance Connection method Sensing distance Part number NPN output PNP output Through-beam Prewired (2 m) E3Z-T61A E3Z-T81A 10 m

Switching Power Supply

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

S82J (10/25/50/100/150/300/600-W Models) CSM_S82J_DS_E_3_1

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

D2D. Door Interlock Switch. Ordering Information. Power Switch with Minimum Contact Gap of 3 mm. Model Number Legend.

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Cylindrical Proximity Sensor

H3CA-8H-AC/100/110/120

Model Number Structure

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

E3X-NA. Adjuster type standard that is the culmination of true ease and simplicity. Super Manual Fiber Amplifier. Features

Load current 10 to 25 A Small Tab Terminal SSR

Item E2CD-C1C3A E2CD-C1R5C3A E2CD-X2R5C3A E2CD-X5C3A 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max.

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

Model Number Structure. Ordering Information. Switch Mode Power Supply S82K (3/7.5/15/30/50/90/100-W Models) Model Number Legend.

Solid-state Timers H3DK

SYSMAC Remote Transistor Module

Miniature Basic Switch

Mini Photoelectric Sensor

Ultra Slim Relays 24

P7TF-IS16/OS16/OS08. I/O classification I/O points Internal I/O common Rated voltage Model 12 VDC P7TF-IS16 DC12 24 VDC P7TF-IS16 DC24 For inputs

Terminals Solder terminals Quick-connect. PCB terminals terminals (#110) 3 A Pin plunger SS-3GP SS-3GPT SS-3GPD SS-3GPB

Classification Enclosure rating Input voltage Type of

Thread length (overall length)

Transistor drive 2c/4c 5A slim power relays

Number of input channels

Model Number Structure

With operation indicators **LY2N-CR **LY2ZN-CR

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

E2EC-CR8D2 5.4 mm dia. 1.5 mm (0.06 in) NO E2EC-C1R5D1 NC. E2EC-C1R5D2 8mmdia. 3 mm (0.12 in) NO E2EC-C3D1 NC

RM22TG. Product data sheet Characteristics. three-phase control relay Vac, 2 C/O. Main. Complementary. Network number of phases

Three-phase Phase-sequence Phase-loss Relay

Transcription:

Solid State Relays with Failure Detection Function G3PC CSM_G3PC_DS_E_1_1 Refer to Safety Precautions for All Solid State Relays. Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater control systems, and contributes to maintenance improvements by the user. Main detection items: SSR short-circuits and SSR open-circuits Alarm output possible to NPN/PNP-input devices. The failure-detection function is built-in and power is supplied from the main circuit power supply making wiring simple. Slim design (width: 22.5 mm) incorporating a heat sink. In addition to screw mounting, DIN track mounting is also possible. Certified by EC, UL, and CSA. Model Number Structure Model Number Legend G3PC-@@@-@ 1 2 3 4 5 1. Basic Model Name G3PC: SSR with Failure Detection Function 2. Rated Load Power Supply Voltage 2: 0 to 240 VAC 3. Rated Load Current 20: 20 A (carry current) 4. Terminal Type B: Screw terminals 5. Certification VD: Certified by UL, CSA, and VDE Ordering Information List of Models Insulation method Zero cross function Indicators Rated output load Model number Phototriac coupler Yes Yes (See page 5) Note: When ordering, specify the rated input voltage. Accessories (Order Separately) Name Dimensions Model number Mounting Track 50 cm (l) 7.3 mm (t) PFP-50N 1 m (l) 7.3 mm (t) PFP-0N 1 m (l) 16 mm (t) PFP-0N2 20 A, 0 to 240 VAC (resistive load: AC, Class1) G3PC-220B-VD Solid State Relays with Failure Detection Function G3PC 1

Specifications Ratings (at an Ambient Temperature of 25 C) Detection Power Supply Main Circuit Rated power supply voltage Operating voltage range Current consumption Operating Circuit Input method Rated input voltage Operating input voltage range Must operate voltage Must release voltage Input current 0 to 240 VAC (50/60 Hz) 75 to 264 VAC (50/60 Hz) 15 ma AC max. (at 200 VAC) Voltage input 12 to 24 VDC 9.6 to 30 VDC 9.6 VDC max. 1 VDC min. 7 ma DC max. (at rated input voltage) Rated load voltage 0 to 240 VAC (50/60 Hz) Operating voltage range 75 to 264 VDC (50/60 Hz) Applicable load current 20 A (Ta = 40) Minimum load current 0.1 A Inrush current resistance (peak value) 220 A (60 Hz, 1 cycle) Permissible (I 2 t) 260 A 2 s Applicable load 4 kw (at 200 VAC) (with Class-1 AC resistive load) Alarm Output Output OFF collector voltage Maximum carry current Output form 30 VDC max. 0.1 A Independent NPN open collector Characteristics Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Main circuit Output ON voltage drop 1.6 V rms max. OFF leakage current ma max. (at 200 VAC) Alarm output Output ON voltage drop 1.5 V max. OFF leakage current 0.1 ma max. Insulation resistance 0 MΩ min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: to 55 to Hz, 0.35-mm single amplitude Shock resistance Destruction: 294 m/s 2 Ambient temperature Operating: 20 to 60 C (with no icing or condensation) Storage: 30 to 70 C (with no icing or condensation) Ambient humidity 45% to 85% Weight Approx. 300 g Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3); Certified by VDE EMC Emission: EN55011 Group 1 Class B Immunity: EN600-6-2 Engineering Data Input Voltage vs. Input Current Input Voltage vs. Input Impedance Input impedance (kω) Input current (ma) Ta = +25 C 25 8 6 Input impedance Load Current vs. Ambient Temperature Load current (A) 20 15 One Cycle Surge Current: Non-repetitive The figure will be less than 1/2 the rated value for repetitive input. Inrush current (A. Peak) 250 200 150 4 2 Input current 5 0 50 0 0 20 30 40-20 0 20 40 60 80 0 Input voltage (V) Ambient temperature ( C) 0 30 50 0 300 500 1,000 3,000 5,000 Energized time (ms) 2 Solid State Relays with Failure Detection Function G3PC

Operation Failure Detection Function Conditions for SSR Failure Detection Failure mode (See note 1.) Operating input (between terminals A1 and A2) Note: 1. The contents of each of the above failure modes is as follows: SSR short-circuit: SSR output circuit remains in the ON state. SSR half-wave short-circuit: SSR output circuit remains in the ON state in one direction. SSR open-circuit: SSR output circuit remains in the OFF state. SSR half-wave open-circuit: SSR output circuit remains in the OFF state in one direction. In addition to the failure modes listed above, detection of circuit disconnections for the load circuit is also possible. (As a rough guide, circuit disconnection will be detected if the load impedance is greater than or equal to 1 MΩ.) 2. The same power supply is used for both the detection and for the output circuit and so detection is not performed during power interruptions. 3. If power supply (terminal 3) is in the open state, the SSR will still turn ON and OFF in the same way but the failure detection function and alarm display will not operate properly. Connection Diagrams (Main Circuit) Detection time The following diagrams show the applicable load connection configurations for SSR failure detection. Alarm display (See note 3.) Alarm display (between terminals X1 and X2) (See note 3.) SSR short-circuit OFF 0.5 s max. (See note 2.) Red Open collector transistor SSR half-wave short-circuit OFF output SSR open-circuit ON SSR half-wave open-circuit ON Single Phase 3-phase Star Connection 3-phase Delta Connection (3-phase, 2-wire Switching) 3-phase V Connection G3PC G3PC G3PC G3PC G3PC G3PC G3PC G3PC Note: With 3-phase connection, so that the power supply voltage is applied between the G3PC s terminals 1/L1 and 3, connect the desired phase to terminal 3. Timing Chart Main circuit power supply (load side) SSR failure detection SSR ON normally SSR OFF normally SSR short-circuit Reset (See note.) SSR open-circuit Reset (See note.) Circuit disconnection detection on the load side Load circuit disconnection Reset (See note.) Operating input (between terminals A1 and A2) Input LED (yellow) Load current RDY/ALM LED (Green: ; Red: ) Alarm output (between terminals X1 and X2) Note: After failure detection, if the detection conditions differ to the conditions given under Conditions for SSR Failure Detection, alarm output is reset. Solid State Relays with Failure Detection Function G3PC 3

Dimensions G3PC-220B-VD 130 max. 114.4 Terminal cover 22.5 max. Tow, 4.6 dia. 13 Mounting Holes Three, 4.5 dia. or M4 68 13.5 8.5x3 = 25.5 0 max. 90±0.2 80 90±0.3 4.5 4.6x5.6 elliptic hole 13±0.3 84.2 Accessories (Order Separately) Mounting Tracks PFP-0N, PFP-50N Note The above diagram is for when the terminal cover is open. PFP-0N2 Note The above diagram is for when the terminal cover is closed. 4.5 15 25 25 25 25 1,000 (500) (see note) 7.3±0.15 15 (5) (see note) 35±0.3 27±0.15 4.5 15 25 25 1,000 25 25 15 16 35±0.3 27 24 29.2 1 1.5 Note Values in parentheses indicate dimensions for the PFP-50N. 4 Solid State Relays with Failure Detection Function G3PC

Installation External Specifications Terminal Arrangement Terminal name Terminal number Screw size Main circuit terminals 1/L1, 2/T1 M4 (output) Detection power supply 3 terminal (input) Operating circuit terminals A1, A2 M3.5 (input) Alarm output terminals (output) X1, X2 Indicators Name Symbol Color Meaning Status indicators RDY Green SSR normal ALM Red SSR failure detection and circuit disconnection detection Input indicator INPUT Yellow Operating Note: The same indicator is used as both the power supply indicator and the alarm indicator. Connection Example Appearance 1/L1 3 A1(IN+) A2(IN ) X1(ALM+) X2(ALM ) 2/T1 RDY/ALM INPUT (See note 1.) Display Labels Voltage output for Temperature Controller, sequencer 12 to 24 VDC Input for Temperature Controller, sequencer L1 1 AC 3 A1 IN A2 X1 ALM X2 30 VDC min. 2 T1 (See note 2.) Note: 1. If the detection power supply terminal (terminal 3) is not connected, failure detection is not performed and so be sure to connect this terminal. 2. If the load is connected to terminal 1/L1, failure detection may not operate correctly and so connect the load to terminal 2/T1. 3. With inductive loads (relay coil, etc.), connect back-current prevention diodes to both sides of the load. Solid State Relays with Failure Detection Function G3PC 5

Safety Precautions Precautions for Correct Use Please observe the following precautions to prevent failure to operate, malfunction, or undesirable effect on product performance. Mounting Method DIN Track Mounting When mounting to a DIN track, mount the G3PC until it clicks into place, otherwise it become loose during use and fall. Fix both ends with end plates. Panel Mounting When mounting directly to a panel, observe the following conditions: Screw diameter: M4 Tightening torque: 0.98 to 1.47 N m Vertical Mounting Panel Horizontal Mounting Note: Use the G3PC at a load current of 50% of the rated load current when it is mounted horizontally. Close Mounting Vertical direction Panel Wiring When using crimp terminals, observe the terminal clearances shown below. Main Circuit Power Supply (Terminals 1 to 3) 7.0 12.4 Make sure that all lead wires are of a thickness appropriate for the current. The output terminals are charged, and touching them may result in electric shock, even when the G3PC is OFF. Separate the outputs from the power supply by installing a circuit-breaker at a higher level in the circuit. Tightening Torque Be sure to tighten the screws to the specified torques given below. Not doing so may result in malfunction. Terminal number Screw terminal Tightening torque diameter A1, A2, X1, X2 M3.5 0.59 to 1.18 N m 1/L1, 2/T1, 3 M4 0.98 to 1.47 N m EMC Directive Compliance Operating Input/Alarm Output (Terminals A1, A2, X1, and X2) M3.5 The Unit complies with the EMC Directives in the following conditions. Wiring duct 80 mm min. 3 m max. Load Input G3PC SSR Output Film Capacitor 1 µf, 250 VAC 5 mm Wiring duct 80 mm min. Connect film capacitors to both sides of the load power supply output. The input cable must be no longer than 3m. Note: Use the G3PC at a load current of 80% of the rated load current when it is mounted side by side. ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. In the interest of product improvement, specifications are subject to change without notice. 6 Solid State Relays with Failure Detection Function G3PC