RTE Series Analog Timers. UL Listed File No. E kPa to 110kPa (Operating), 70kPa to 110kPa (Transport)

Similar documents
Timers NEW DESIGN! RTE Series. RTE Series Analog Timers

Timers. GT3W Series Dual Time Range Timers. 250V AC/150V DC Time Range. 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours

DIN Rail Mounting Accessories. Style Appearance Use with Timers Part No. Appearance Part No. RTE-P2 SR3P Pin FingerSafe Socket RTE-P2 SR3P-05C

T imers Timers Selection Guide Timing Diagrams Overview RTE Series Analog Timers Instructions onlinecomponents.com IDEC.

Timers. RTE Series. RTE Series Analog Timers. Specifications. G-8 USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC

GT3F Series True OFF Delay Timers

Timers. GT5Y Series ON Delay Timers. ±3% maximum (over 10 to 50 C, reference temperature 20 C) Setting Error. ±10% maximum

Relays & Sockets RR Series Power Relays. Part Number Selection

TIMERS FOR ALL APPLICATIONS

PS5R Series Switching Power Supplies. The PS5R offers a sleek, compact, ergonomic design, worldwide approvals, and broad range of output capacities.

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Intrinsically Safe Explosion Proof Barriers

Safety Control. FS1A Multi-function Safety Relay. Optional Parts. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide

Power Supplies. PS5R Standard Series Switching Power Supplies. Part Numbers. Part Number

Ultra Slim Relays 24

Communication & Networking

PRODUCT SPECIFICATION. PC Board Relays. Series.

Page Housing Plastic Metal Mounting DIN Rail or surface mount Panel or bracket mount Wattage Range 10W to 240W 7.5W to 240W 10W to 300W

Multi Voltage Options. Multi Voltage Options 110VAC + 24VAC/DC 230VAC + 24VAC/DC 24VAC/DC 110VAC 230VAC

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Conforms to VDE0435/2021 C/250, VDE0110, VDE0106/P100 Conforms to EN , pren

RUC industrial relays of small dimensions

Solid-state Timer H3YN

DIN 48 SIZE DIGITAL TIMER. Compact, Easy-to-read, Easy-to-use... A digital timer made to meet the market s needs.

RM84 miniature relays

HR1S-AC Safety Relay Modules

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR

RUC industrial relays of small dimensions

Solid-state Timer. Ordering Information. Miniature Timer with Multiple Time Ranges and Multiple Operating Modes H3YN- - Accessories (Order Separately)

RUC-M industrial relays for DC loads

PROGRAMMABLE MULTI-FUNCTION

PROGRAMMABLE MULTI-RANGE REPEAT CYCLE & DELAYED INTERVAL

NON-PROGRAMMABLE ON DELAY, INTERVAL, TRUE OFF DELAY & FLASHER

H3CR-F H3CR-F8 H3CR-F-300 H3CR-F8-300

Solid-state Timer. Ordering Information. Ultra-slim Timer for G2R Relay Socket. H3RN-jj. Accessories (Order Separately) Connecting Socket

Interlock Switches. Selection Guide. HS7A-DMC Magnetic Safety Switches

Self-Powered Counters H7EC

Conductive Level Controller

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Thermal-Magnetic Circuit Breaker 2216-S

Communications & Networking

PC RELAY TERMINAL/ PC TERMINAL

H3CA-8H-AC/100/110/120

Solid-State Counter/Timer

Contact form. Operating Force. SPDT 25g Unsealed Solder / 187 Quick Connect. SPDT 50g Unsealed Solder / 187 Quick Connect

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

Contact form. Operating Force. SPDT 100g Unsealed Solder / 187 Quick Connect. SPDT 200g Unsealed Solder / 187 Quick Connect

Sockets. SY Series: DIN Rail Snap-Mount. F-14 USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC. SY4S Sockets SY4S-05

Micro Contactor MA Series

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

Functional configuration Rated input voltage Power ratings Output voltage Output current Part number Non-PFC

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Making Hazardous Operations Safe and Productive

NON-PROGRAMMABLE OFF DELAY, SINGLE SHOT

Magnetic and Hydraulic-Magnetic Circuit Breaker 8340-F...

Solid-state Timer. Mounting system contact t contact. t Surface mounting/ track mounting

Relays & Sockets. RQ Series. RQ Series PCB Relays Part Number Selection

Safety Relay Unit (I/O Unit Type)

Transistor drive 2c/4c 5A slim power relays

Barriers. EB3N Discrete Input Barrier with Redundant Output

masterelectronics.com onlinecomponents.com

S8VE (60/90/120/180/240-W Models)

Syr-line TMR48D Digital Timer

AS-Interface Safety at Work

Classification Enclosure rating Input voltage Type of

Syr-line TMR48D Digital Timer

Special-purpose Basic Switch

Switching Power Supply S8E1. Ordering Information. Compact and Economical Switching Power Supply

Cable specifications PVC

Sensing method Appearance Connection method Sensing distance Output Model. M12 connector 10±3 mm. Size Type Appearance Cable length Model Straight

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

812/ 814/ 815 digital timers

Basic Switch. Pin plunger Short hinge Hinge lever Long hinge lever Simulated hinge Short hinge Hinge roller lever lever roller lever lever

Solid-state Timer H3FA. Model Number Structure. DIP Model Timer for PC Board Use Provides Contact and Solid-state Output

Time-limit operation/ self-resetting DPDT --- H3M H3M with Y92F-40 adapter SPDT SPDT H3M-H H3M-H with Y92F-40 adapter

Time-limit contact Time ranges Supply voltage Mounting s to 3 h 24, 100 to 120, 200 to 230 VAC (50/60 Hz); 12, 24, 48, 125, 100 to 110 VDC

SH Series: DIN Rail Snap-Mount Sockets. SH1B Sockets " (17mm) Ø 0.140" (3.6mm) 2.613" (67mm) 0.63" 0.098" (16mm) (2.5mm) 0.

Model Number Structure

Temperature Controller E5C4

SAFETY RELAY YRB-4EML-31S MAIN FEATURES

Long-time range model (0.1 min to 10 h) 24 VAC; SPDT H3RN-1 H3RN-11 12, 24 VDC DPST-NO H3RN-2 H3RN-21

ALLEN BRADLEY RELAY Bulletin 700-HF

HIGH PERFORMANCE MINIATURE SWITCHES WITH WIDE RANGE

Magnetic and Hydraulic-Magnetic Circuit Breaker

Operating instructions Enabling switch (handle switch) ZSD5 ZSD6. 1. About this document. Content. 7 Appendix 7.1 Wiring example...

TeSys IEC Contactors and Overload Relays

FS1A Safety Controller

3 Pole Contactors with AC operating coils

G9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function

Relays & Sockets. RSC Series. RSC Series Solid State Relays. Part Number Selection Specifications

PROGRAMMABLE CONTROLLER. FP0 A/D Converter Unit. Technical Manual ARCT1F321E

Communications & Networking

Safety relay emergency stop/protective door, 24VDC/AC, 4 enabling paths

Digital Timer. Ordering Information. 1/16 DIN, Quartz Timer with Four-Digit LED Display

RF1V Force Guided Relays SF1V Relay Sockets

PSR UC/ESAM4/3X1/1X2/B

Operating instructions. Speed monitor D / / 2014

1492-SP Supplementary Protectors

Thermal-Magnetic Circuit Breaker 4220-T...

Model Number Structure

Transcription:

Analog Key features of the RE series include: 0 time ranges and 0 timing functions ime delays up to 600 hours Space-saving package High repeat accuracy of ± 0.% ON and timing LED indicators Standard 8- or -pin and -blade termination form C delayed output contacts 0A Rating Cert. No. E9950933336 (EMC, RE) cert. No. BL9608333355 (LVD, RE) UL Listed File No. E66043 eneral Specifications System Solid state CMOS Circuit ype Multi-Mode ime Range 0.sec to 600 hours Pollution Degree (IE60664-) Over voltage category III (IE60664-) AF0 00-40V AC(50/60Hz) Rated al AD4 4V AC(50/60Hz)/4V DC Voltage D V DC AF0 85-64V AC(50/60Hz) Voltage olerance AD4 0.4-6.4V AC(50/60Hz)/.6-6.4V DC D 0.8-3.V DC Input off Voltage Rated Voltage x0% minimum Ambient Operating emperature -0 to +65ºC (without freezing) Ambient Storage and ransport emperature -30 to +75ºC (without freezing) Relative Humidity 35 to 85%RH (without condensation) Atmospheric Pressure 80kPa to 0kPa (Operating), 70kPa to 0kPa (ransport) Reset ime 00msec maximum Repeat Error ±0.%, ±0msec* Voltage Error ±0.%, ±0msec* emperature Error ±0.5%, ±0msec* Setting Error ±0% maximum Insulation Resistance 00MΩ minimum (500V DC) Between power and output terminals: 000V AC, minute Dielectric Strength Between contacts of different poles: 000V AC, minute Between contacts of the same pole:000v AC, minute Vibration Resistance 0 to 55Hz amplitude 0.5mm hours in each of 3 axes Operating extremes: 98m/sec (0) Shock Resistance Damage limits: 490m/sec (50) 3 times in each of 3 axes Degree of Protection IP40 (enclosure) (IEC6059) YPE RE-P, -B RE-P, -B Consumption (Approx.) AF0 0V AC/60Hz 6.5VA 6.6VA 40V AC/60Hz.6VA.6VA 4V AC 60Hz/DC 3.4VA/.7W 3.5VA/.7W D.6W.6W Free Mounting Position RE-P, P 40Hx 36W x 77.9D mm Dimensions RE-B, B 40Hx 36W x 74.9D mm RE-P RE-P RE-B, -B Weight (Approx.) 87g 89g 85g *For the value of the error against a preset time, whichever the largest. Ratings Form C, DPD Configuration (Delay output) Allowable Voltage / 40V AC, 30V DC / 0A Allowable Current Maximum Permissible 800 cycles per hour Operating Frequency Rated Load Life Resistive Inductive Horse Rating Electrical Mechanical 0A 40V AC, 30V DC 7A 40V AC, 30V DC /6 HP 0V AC, /3 HP 40V AC 500,000 op. minimum (Resistive) 50,000,000 op. minimum RE able of Contents Specifications -8 Part Number uide -9 Part Number List -9 RE iming Diagrams -0 RE Accessories - Instructions: Setting imer - RE Dimensions -3 eneral iming Diagrams -4-8 www.idec.com USA: (800) 6-IDEC or (408) 747-0550, Canada: (888) 37-IDEC

Part Numbering uide RE series part numbers are composed of 4 part number codes. When ordering a RE series part, select one code from each category. Example: RE-PAF0 RE P AF0 ➀ Series ➁ erminal Style ➂ Function roup ➃ Input Voltage Part Numbers: Description Part Number Code Remarks ➀ Series RE series RE For internal circuits, see next page. ➁ erminal Style ➂ Function roup ➃ Input Voltage Pin Blade ON-delay, interval, cycle OFF, cycle ON ON-delay, cycle OFF, cycle ON, signal ON/OFF delay, OFF-delay, one-shot 00 to 40V AC(50/60Hz) AF0 4V AC(50/60Hz)/4V DC AD4 V DC D P B Select one only. Each function group has different timing functions. See page -4. Part Number List Part Numbers riggered Input riggered Voltage 8-Pin Blade -Pin Blade V DC RE-PD RE-BD RE-PD RE-BD 4V AC/DC RE-PAD4 RE-BAD4 RE-PAD4 RE-BAD4 00-40V AC RE-PAF0 RE-BAF0 RE-PAF0 RE-BAF0 ime Range able ime Range Determined by ime Range Selector & Dial Selector Dial 0-0 - 3 0-0 0-30 0-60 Second 0. sec - sec 0. sec - 3 sec 0. sec - 0 sec 0.6 sec - 30 sec. sec - 60 sec Range Minute. sec - min 3.6 sec - 3 min sec - 0 min 36 sec - 30 min. min - 60 min Hour. min - hr 3.6 min - 3 hr min - 0 hr 36 min - 30 hr. hr - 60 hr 0 Hours min - 0 hr 36 min - 30 hr hr - 00 hr 6 hr - 300 hr hr - 600 hr www.idec.com USA: (800) 6-IDEC or (408) 747-0550, Canada: (888) 37-IDEC -9

iming Diagrams RE-P 3 4 5 8 6 7 external control RE-P 3 start 4 8 9 0 RE-B 7 8 A 3 5 6 9 B external control RE-B A start 3 4 5 6 7 8 RE-P, -B A: ON-Delay (power start) B: Interval (power start) Set timer for desired delay, apply power to coil. s transfer after preset time Set timer for desired delay, apply power to coil. s transfer immediately, and has elapsed, and remain in transferred position until timer is reset. Reset occurs return to original position after preset time has elapsed. Reset occurs with removal with removal of power. of power. ()-7 ()A-B ()-4,5-8 ()-7,3-9 (NC) ()-3,6-8 ()4-7,6-9 (NO) 9 B ()-7 ()A-B ()-4,5-8 ()-7,3-9 (NC) ()-3,6-8 ()4-7,6-9 (NO). RE-P: Do not apply voltage to terminals #5, #6 & #7.. RE-B, -B: Do not apply voltage to terminals #, #5 & #8. 3. IDEC sockets are as follows: RE-P: SRP-06* pin type socket, RE-P: SR3P-05* pin type socket, RE-B, -B: SR3B-05* blade type socket, (*-may be followed by suffix letter A,B,C or U). C: Cycle (power start, OFF first) Set timer for desired delay, apply power to coil. First transfer of contacts occurs after preset delay has elapsed, after the next elapse of preset delay contacts return to original position. he timer now cycles between on and off as long as power is applied (duty ratio :). ()-7 ()A-B ()-4,5-8 ()-7,3-9 (NC) ()-3,6-8 ()4-7,6-9 (NO) A: ON-Delay (signal start) When a preset time has elapsed after the start input turned on while power is on, the NO output contact goes on. (A)-0 (B)-5 (A)-4,8- (B)-7,3-9 (NC) (A)-3,9- D: Cycle 3 (power start, ON first) Functions in same manner as Mode C, with the exception that first transfer of contacts occurs as soon as power is applied. he ratio is :. ime On = ime Off ()-7 ()A-B ()-4,5-8 ()-7,3-9 (NC) ()-3,6-8 ()4-7,6-9 (NO) RE-P, -B B: Cycle (signal start, OFF first) When the start input turns on while power is on, the output oscillates at a preset cycle (duty ratio :), starting while the NO contact off. (A)-0 (B)-5 (A)-4,8- (B)-7,3-9 (NC) (A)-3,9- C: Cycle 4 (signal start, ON first) When the start input turns on while power is on, the NO contact goes on. he output oscillates at a preset cycle (duty ratio :). (A)-0 (B)-5 (A)-4,8- (B)-7,3-9 (NC) (A)-3,9- E: Signal OFF-Delay When power is turned on while the start input is on, the NO output contact goes on. When a preset time has elapsed after the start input turned off, the NO output contact goes off. (A)-0 (B)-5 (A)-4,8- (B)-7,3-9 (NC) (A)-3,9- a F: One-Shot (signal start) When the start input turns on while power is on, the NO output contact goes on. When a preset time has elapsed, the NO output contact goes off. (A)-0 (B)-5 (A)-4,8- (B)-7,3-9 (NC) (A)-3,9- D: Signal ON/OFF-Delay When the start input turns on while power is on, the NO output contact goes on. When a preset time has elapsed while the start input remains on, the output contact goes off. When the start input turns off, the NO contact goes on again. When a preset time has elapsed after the start input turned off, the NO contact goes off. (A)-0 (B)-5 (A)-4,8- (B)-7,3-9 (NC) (A)-3,9- a a a a a a Note : =, a=shorter than set time, (): RE-P, (): RE-B, (A): RE-P, (B): RE-B -0 www.idec.com USA: (800) 6-IDEC or (408) 747-0550, Canada: (888) 37-IDEC

emperature Derating Curves Mounting A Allowable Current 0A 7A Mounting B Allowable Current Mounting A Mounting B Derating Curve Derating Curve 50ºC 65ºC 50ºC 65ºC Ambient emperature Ambient emperature 7A 5A Instructions ypes RE-PAF0 Connection type P: Pin B: Blade Mode : No Control Signal A: ON-Delay B: Interval C: Cycle D: Cycle 3 Installation of Hold-Down Springs DIN Rail Mount Socket Insert the springs into the outer slots with the projections facing inside. Voltage AF0: 00 to 40V AC(50/60Hz) AD4: 4V AC(50/60Hz)/4V DC D: V DC : Control Signal A: ON-Delay B: Cycle C: Cycle 4 D: Signal ON/OFF-Delay E: Signal OFF-Delay F: One-Shot Insert the springs into the slots. Switch Settings 3 Mode Selector Scale Selector 3 ime Range Selector. urn the selectors securely using a flat screwdriver 4mm wide (maximum). Note that incorrect setting may cause malfunction. Do not turn the selectors beyond their limits.. Since changing the setting during timer operation may cause malfunction, turn power off before changing. Socket SRP-06 Hold-down Spring (sold separately) SFA-0 (use two springs) Socket SR3P-05 Hold-down Spring (sold separately) SFA-03 (use two springs) Safety Precautions Special expertise is required to use Electronic. All Electronic are manufactured under IDEC's rigorous quality control system, but users must add a backup or fail safe provision to the control system when using the Electronic imer in applications where heavy damage or personal injury may occur should the Electronic imer fail. Install the Electronic imer according to instructions described in this catalog. Make sure that the operating conditions are as described in the specifications. If you are uncertain about the specifications, contact IDEC in advance. In these directions, safety precautions are categorized in order of importance under Warning and Caution. Warnings Warning notices are used to emphasize that improper operation may cause severe personal injury or death. urn power off to the Electronic timer before starting installation, removal, wiring, maintenance, and inspection on the Electronic imer. Failure to turn power off may cause electrical shocks or fire hazard. Do not use the Electronic imer for an emergency stop circuit or interlocking circuit. If the Electronic imer should fail, a machine malfunction, breakdown, or accident may occur. Caution Caution notices are used where inattention might cause personal injury or damage to equipment. he Electronic imer is designed for installation in equipment. Do not install the Electronic imer outside equipment. Install the Electronic imer in environments described in the specifications. If the Electronic imer is used in places where it will be subjected to high-temperature, high-humidity, condensation, corrosive gases, excessive vibrations, or excessive shocks, then electrical shocks, fire hazard, or malfunction could result. Use an IEC607-approved fuse and circuit breaker on the power and output line outside the Electronic imer. Do not disassemble, repair, or modify the Electronic imer. When disposing of the Electronic imer, do so as industrial waste. www.idec.com USA: (800) 6-IDEC or (408) 747-0550, Canada: (888) 37-IDEC -

DIN Rail Mounting Accessories Part Numbers: DIN Rail/Surface Mount Sockets and Hold-Down Springs DIN Rail Mount Socket Applicable Hold-Down Springs Style Appearance Use with Part No. Appearance Part No. -Pin Screw erminal (dual tier) RE-P SR3P-05 SFA-03 -Pin FingerSafe Socket RE-P SR3P-05C 8-Pin Screw erminal RE-P SRP-06 SFA-0 -Blade Screw erminal RE-B RE-B SR3B-05 DIN Mounting Rail Length 000mm BNDN000 Panel Mounting Accessories Part Numbers: Flush Panel Mount Adapter and Sockets that use an Adapter Accessory Description Appearance Use with Part No. Panel Mount Adapter Adaptor for flush panel mounting RE timers All RE timers RB-0 8-pin screw terminal (Shown: RE-P SR6P-M08 SR6P-M08 Wiring Socket Adapter) -pin screw terminal RE-P SR6P-M Sockets for use with Panel Mount Adapter 8-pin solder terminal RE-P SR6P-S08 -pin solder terminal RE-P SR6P-S No hold down clips are available for flush panel mounting applications. - www.idec.com USA: (800) 6-IDEC or (408) 747-0550, Canada: (888) 37-IDEC

Dimensions 36.0 3.7 77.9 3.0 40.0 RE-P (8 pin) erminal Style RE-P ( pin)erminal Style 7.3 RE-B/RE-B ( blade) erminal Style Panel Mount Adapter RE imer, 8-Pin and -Pin with SR6P-S08 or SR6P-S 98 maximum Panel hickness 0.8 to 5mm 48.7 4.5 48 6. Back Wiring Socket RE imer, 8-Pin with SR6P-M08 Panel hickness 0.8 to 5mm 8-M3.5 erminal Screw 44.6 3.5 max. 5.6 min. 3 4 5 6 ø3.6 min. 44.6 30.4 8 7 6.9 max. 7 80.5 9.8 3 RE imer, -Pin with SR6P-M -M3.5 eminal Screws 45 6.7 7 6 5 3.5 max. 5.8 min. ø3.6 min. 45 34 6.9 max. 4 3 8 9 0 30.5 7 9 8.5 4 www.idec.com USA: (800) 6-IDEC or (408) 747-0550, Canada: (888) 37-IDEC -3