D O O R S T A T I O N W I T H P R O X I M I T Y R E A D E R

Similar documents
EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

A P K I T K P C O L O U R V I D E O D O O R E N T R Y S Y S T E M U S E R M A N U A L. w w w. e s p u k. c o m

EZTAG3 PROXIMITY AND KEYPAD DOOR ENTRY

EZ-TAG2 Manual_Layout 5 11/12/ :14 Page 1 U S E R M A N UAL

APWIFIDS WI-FI DOOR STATION

MS-7000: SuperStar Reader

MULTIWAY 2-12 WAY DOOR ENTRY SYSTEM

MS-5000: MiniStar Reader

212iL Rev. 1.1


Intelligent Security & Fire Ltd

Digital Keypad Introduction

DP2 DOOR PHONE. For Technical Assistance Please Phone: (07)

MS-5000 MiniStar Reader. Quick Start Guide MS The MS-5000 MiniStar Reader. 1.0 Specifications

TECHNICAL MANUAL EDITION 1.4 SENTRY TECHNICAL MANUAL

Zartek. CDP-808 Two Button Wireless Intercom Installers Manual

Section A5. Standard Telephone Entry Systems. This Price Schedule is effective April 1, Date Page Comment

Installing Keypad and Backplate

Wi-Card Skeet-Trap Claymate Operator and User Manual

CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions

CP150B Vandal & Weather Resistant Keypad Security Systems

User Manual. PCKeypad Wireless Keypad

DP4 DOOR PHONE. For Technical Assistance Please Phone: (07)

DP2. Door Phone. For Technical Assistance call the Manufacturers direct ph AM - 5PM West Coast Pacific Time

ZDL-V200. Refer to Steps: 1 Thru. 4 Please Follow Wiring Steps Carefully.

Waterproof. Keypad/Reader/Controller

AUDIO AND VIDEO KITS SECTION CONTENTS 66

MODEL KP-100 ACCESS CONTROL DIGITAL KEYPAD OPERATING INSTRUCTIONS

MS-3000 MicroStar Reader

DIGITAL 2 WIRE SYSTEM

ACT 5e prox Operating and Installation Instructions ACT Product Code: ACT 5e prox

SVT-WIFI Video Intercom System C

WELCOME. For customer support or any inquiries, please visit our web site at or contact us at

MS-4000: ShootingStar Reader

Wiring Diagram and Programming Instructions for MAW6 Digital Keypad and Proximity Card/F reader

Wiring Inside the card reader you will see a circuit board. The connections are as follows:

F6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode

TELEPHONE TECHNICAL SERVICES DS2 USER GUIDE

INSTALLATION INSTRUCTIONS

W3-H Waterproof Keypad/Reader/Controller

FTK5 PROXIMITY KEYPAD

Instruction Manual. Vogue. Security. Technology. Innovation 2013-V01

the Interactive Catalog

X/Y Issues on ASP-645-1

GV-EL124S Electric Strike

April 2015 PRICE SCHEDULE A 2.0 Stand-Alone Access Control

DS1 USER GUIDE. For Technical Assistance call the Manufacturers direct Ph AM - 5PM West Coast Pacific Time

Wiring Instructions v4

How To Install: C4000 EMV Upgrade Kit

Classe 300. a STYLISH choice

ACTentry A5 Kit. ACTentry A5 Entry Panel. Audio Door Entry with Access Control. Audio Door Entry & Access Control Kit Features

Single Door Standalone Access Control User Manual

User Manual. Split access control with intelligent secured power supply.

8. Electric Lock Connection

TECHNICAL MANUAL. 25H/DDA One button DDA audio intercom kit TECHNICAL MANUAL EDITION 1.1

1 Installing the VG4-A-ARMPLATE

LED Lighting Kit For Elara NanoEdge Fixed Frame. Installation Guide. Attention: Read this guide before assembling your screen.

EL-ST100 KEYPAD CONTROLLER

smartentry Wireless Video Doorphone User Manual

Camden - Key Switches

AUDIO AND VIDEO DOOR ENTRY SYSTEM WITH NEXA CODED PANEL

TOUCHLOCK compact. Master code: Paxton Access Ltd. ins TOUCHLOCK compact kit. Document Contents. Instructions for the following:

PUSH BUTTON PANEL. SECTION 3A (Rev. B) SECTION CONTENTS. Download from Technical Manuals area. sec.3a

Call Origination: Speaker/Mic: Camera: Mounting: Construction: Directory: Camera Aperture: Dimensions: Architects and Engineers Specification

2000 Series e/em Style Keypad Installation and Programming Manual

Installation & User Manual V1.0

Stand-alone Proximity Access Control

CM-110SK Standalone Keypad Installation Instructions

The Pyramid Series features five readers, each with its own unique characteristics, to meet virtually any requirements an end-user may have.

Installation Instructions 4291 and 4292 Keypads

Key Switch. Document version: 1.5 (Updated 02 May 2017)

Physical Specification Vending Machine Card Reader Module Model: CRM-170-xx

A Axis M-Functions Level 1 A Axis Standard A Axis SMT Level 2. Each console includes the following:

ACTpro Single Door IP Controller. Operating & Installation Instructions

D45 System. Digital colour entrance panel with addresses list

Specifications: Features:

RD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual

UC-2000 Installation Manual Unicorn Computers Technology Limited

ZAVIO Outdoor IR Mini Dome. Quick Installation Guide

January 2013 PRICE SCHEDULE A 2.0. Access Plus Telephone Entry & Access Control

PPB & AS Push Buttons

RBR-SB-KTZ001 LAR 2. User Manual

duplex communication (with handset) hands-free talking simplex communication can be activated standard 4 (up to 2 from front-door stations)

-DTZ001- Stand-Alone Proximity Access Control. User Manual

Service Manual For. -IP Voice over Internet Protocol -ACH** Handset cord length Inches

VIDI-AC-2CS Access Controller/ Reader

Installation instructions for Aluminium Pantel, Pancode and Pancam C & T Telephone door access control units

Front-door station series for surface-mounting Profi-Economic PES Profi-Design PDS

INSTALLATION INSTRUCTIONS Model 930 EntryCheck

TELEPHONES & CABINETS

232iLM Keypad Installation and Programming Instructions

CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions

232iLM Keypad Installation & Programming Instructions

SERVICE MANUAL MODEL SSC-301-F (FORMERLY 301-FS) MODEL BLC-301-F (FORMERLY 301-F)

Pyramid Series Proximity Readers

Documentation on all Paxton products can be found on our web site -

AlphaStatus Room Status System Installation and Use Instructions for the RSS400 Series Room Stations and Optional Master Station(s)

2 WIRE Video Door Entry system

Configuring a Net2 Entry Monitor

C e l l C O M. G S M I n t e r c o m

Transcription:

D O O R S T A T I O N W I T H P R O X I M I T Y R E A D E R

Table of contents Planning and installing the Enterview VX............................ 3 Wiring Diagram..................................................... 5 Fitting the external call station..................................... 6 Fitting and wiring the handset...................................... 7 Programming the Enterview VX proximity reader..................... 9 Troubleshooting guide............................................ 11 Optional accessories for Enterview VX............................. 12 EVVX1PRF 1 button proximity flush mount video door station EVVX1PRS 1 button proximity surface mount video door station 2

Planning and installing the Enterview VX External call station How many Entry Doors (Front or/and Rear) Mounting: flush or surface. Equipment required External call station (one required per door) Maximum of 4 call buttons External call station power supply DC 12 volts (EVBPS) (one required per door) Handset EV5H/EV5HF (minimum of one per external call button) The maximum distance per supplied power supply to each handset is 10 meters using 2 pairs of CAT5e cable. Electric lock magnetic (ML250)/Yale type (ENTERD) CAT5e cable minimum 4 cores (see Note above regarding cable distances) Push to exit button (one required per door if magnetic lock used) Emergency break glass (One required per door if magnetic lock used and the door is deemed and emergency exit) Combined timed lock and outdoor call station power supply (EVBPS) Note: The maximum cable distance from the external panel to each internal handset is 100 meters using CAT5e cable. Handsets Audio/video handsets: a minimum of one per external call button/ a maximum of 4 video door entry handsets and 2 audio only handsets. Each handset requires the supplied power supply. Door Gear Power supply with timed output (EVBPS) Magnetic lock or Yale type lock Push to exit button and emergency break glass (only needed when magnetic lock fitted to an emergency exit door) 3

Basic cabling 240 VAC mains feed to external door and lock control power supply (EVBPS) 240 VAC mains feed to each handset (via transformer- supplied) 4 core from each external call station (front/rear) to its own power supply (EVBPS) CAT5e from each external call station (front/rear) to each handset 4 core from push to exit button to EVBPS (power supply) 4 core from lock to EVBPS (power supply) 4 core from EVBPS (power supply) to emergency break glass (if fitted) 2 pairs of CAT5e from supplied power supply to each handset Note: The maximum cable distance from the external panel to each internal handset is 100 meters using CAT5e cable. The maximum distance per supplied power supply to each handset is 10 meters using 2 pairs of CAT5e cable. 4

Wiring diagram Fig. 1 5

Fitting the external call station Select a location close to the FLUSH MOUNTING door to be controlled Recommended mounting height 1.45 meters (camera lens) Secure back plate to the wall paying attention to the upward facing arrow located on the back plate Feed cables from each apartment and the power supply through the cable entry hole, the entry hole will need to be knocked out. Fig. 2 Wiring the external call station Each call button will have its own brown 4 core connector (supplied) consisting of red, blue, yellow and white cores. The 4 colours that are connected to the brown connector are to be connected to the corresponding 4 core cable going to each of the apartments. The connection can be completed by means of soldering, crimping or by use of screw connectors. To power the camera, keypad and call station a 12 volt DC feed is required. To do this a white two pin plug consisting of red and black cores supplied should be connected to the corresponding cable going to the EVBPS power supply. The two single black cables on the external call station are for the lock release. These are volt free and are normally open going closed. These contacts will change state on the lock release command. The two black cables need to be connected the EVBPS p.b terminal Fig. 3 6

Removing name tag To remove name tag: 1) Push in name tag on the left-hand side 2) Slide name tag from right to left Fitting and wiring the handset On all types of handsets fitted to a EVVX system please remove the jumper labeled J3. This can be found next to the connecting plugs on the rear. Locate the metal back plate and observe the arrow and the word up. Fit mounting plate to the selected location, recommended mounting height 1.45m Feed the cable from the local transformer and the external call button though the center opening Connect the corresponding cores from the external call button cable to the brown plug (supplied) consisting of red, blue, yellow and white cores. Once connected, fit the brown plug into the rear of the handset socket CN1 for call station one and CN2 for external call station two. Connect the corresponding cores from the transformer to the white plug (supplied) consisting of red and black cores. Once connected, fit the white plug into the rear of the handset socket marked 5 (+) and 6 Fig. 4 Note: J1 and J2 are not used. Remove J3 on all handsets for multiway capability. 7

Fig. 5 Fig. 6 8

Fitting the handset to the bracket Locate the 4 lugs on the metal back plate, one located on each corner see Fig. 7, these lugs must fit into the recesses on the rear of the hand set. Place the handset over the metal back plate keeping the cables flat and out of the way of the lugs. Slide the hand set down into position engaging the 4 lugs on the back plate into the recesses of the hand set. Lugs Lugs Fig. 7 Item 1 Programming the Enterview VX Proximity Reader All system programming requires the EVVX remote control. System programming cannot be performed without it. To enter programming mode press * # followed by the 4 digit programing code (The factory default programming code: 4567) followed by #, the indication light on the reader will change from red to amber and a long single confirmation tone will be heard. It is mandatory to keep an on-site record of which user holds possession of which numbered card/tag and what location number it is registered to. A card/tag cannot be deleted from the system if the location number or the whereabouts of the card/tag are unknown. Adding User Cards/Tags using the card/tag numbers Enter programming mode. Press 1 - a single confirmation tone will be heard Enter the last 6 digits of the new card/tag to be added, a single confirmation tone will be heard. To add further cards simply enter the last 6 digits of the next card. If the error tone is emitted (4x beeps), this indicates that this card/tag is already registered Adding User Cards/Tags by swiping Enter programming mode. Press 1 - a single confirmation tone will be heard 9

Swipe the new card/tag to be added, a double confirmation tone will be heard. To add further cards simply swipe the next card/tag. If the error tone is emitted (4x beeps), this indicates that this card/tag is already registered Deleting user cards/tags Enter programming mode. Press 2 - a single confirmation tone will be heard Enter the last 6 digits of the new card/tag to be deleted, a single confirmation tone will be heard. To delete further cards simply enter the last 6 digits of the next card/tag. If the error tone is emitted (4x beeps), this indicates that this card/tag is already deleted Deleting User Cards/Tags by swiping Enter programming mode. Press 2 - a single confirmation tone will be heard Swipe the new card/tag to be deleted, a double confirmation tone will be heard. To delete further cards simply swipe the next card/tag. If the error tone is emitted (4x beeps), this indicates that this card/tag is already deleted Deleting all user cards/tags Enter programming mode. Press 9 - a single confirmation tone will be heard. Press 9 again - a double confirmation tone will be heard, once this tone stops the delete all command is complete. Setting the Unlock time Factory default door open time is set at 05 seconds. Enter programming mode. Press 4 - a single confirmation tone will be heard Enter the desired lock/relay operation time in a two digit format (01 to 99 seconds) - a double confirmation tone will be heard. The Unlock time is now changed. Changing the programming code Factory default pin 4567. Enter programming mode. Press 8 - a single confirmation tone will be heard. Enter the new 4 digit programming code and press # - a single confirmation tone will be heard. Re-enter the new 4 digit programming code and press # - a double confirmation tone will be heard. 10

Reset a forgotten programming code Turn-off power for 60seconds Turn-on power again and press # for 3 seconds - a single confirmation tone will be heard. Code is now reset to factory default. Trouble Shooting Guide No picture appears on the monitor (blue or white screen) Check that all wires are connected and connected in the correct configuration Check that the voltage at the back of the monitor across terminals 5 and 6. The voltage should be over 14.3vDC, if it is not then the handset will not function correctly One or more monitors are not working but others are Check that all wires are connected and connected in the correct configuration Swap the monitor positions around. This will identify if the issue lies with the monitor or the location of the monitor. For example - monitor 1 does not work, monitor 2 does, when swopped around monitor 1 works in monitor 2 s location. There is a problem with monitor 2 s location (wiring problem etc) If no monitors work Check that power is supplied to each monitor and that the specifications for installation have been followed correctly Check that all wires are connected and connected in the correct configuration Run a new length of short cable and connect a monitor next to the camera, this will rule out any issue with lack of voltage and/or cable run length. The PSU s supplied with each monitor must be used and the cable length from PSU to monitor must not exceed 10m In multi apartment systems if more than one apartments monitor rings simultaneously Remove jumper J3 from all handsets Please also check The monitor and the outdoor station connections are colour coded - ensure the colours are matched Connect to the CN1 terminal on the back of the handset for a single outdoor station system Connect to the CN2 terminal on the back of the handset if a 2nd outdoor station is used The electro-magnetic lock (MAGLOCK) will not energise The electro-magnetic lock (MAGLOCK) requires 12vDC to lock. Trace the 12vDC from the lock to the power supply source and test that sufficient power is reaching the lock If using the EVBPS Please ensure that the N.C switch is in position for an electro-magnetic lock release Please ensure that the N.O switch is in position for a Yale style lock release The electro-magnetic lock (MAGLOCK) does not have enough holding force Check the voltage and ensure that the rubber washer has been fitted along with the armature, this will enable enough movement for the magnet and armature to line-up correctly as the movement allowed compensates for misalignments on the door / frame 11

Optional accessories for Enterview VX EVH5C-HF Hands Free Colour Handset High resolution colour 7 monitor Door release button Up to 3 additional handsets per system EVH5C Colour Handset High resolution colour 4 monitor Door release button Up to 3 additional handsets per system EVHF10W and EVHF10B - Colour handsfree 10" monitor High resolution colour 10 monitor Contemporary black or white design Door release button Two camera input EVH5AO Audio only handset Clear high quality audio Door release button Up to two per system EVBPS - Boxed power supply for use with lock release 100-240vAC, 50/60Hz input 1.5A /12vDC output (NO/NC selectable) 1A 12vDC output Size: 129 x 73 x 50mm LWD EV-ML-250 Electromagnetic Lock Holding force 250kg/550lbs max 420ma 12vdc input Z & L mounting bracket included NB. Requires EV-BPS power supply EV-EXIT Push to Exit Lock release button Stainless steel fascia Flush mounting (back box included) Push to make contacts EV-EBG Emergency Break Glass Surface mounted Emergency break glass to release door ENTERD Electromagnetic Lock Holding force 295kg/650lbs 160ma 12vdc input For use with Yale type rim locks Surface mounting version available NB. Requires EV-BPS power supply Elite Security Products Unit 7, Target Park, Shawbank Rd Lakeside, Redditch B98 8YN Telephone: 01527 515150 email: info@espuk.com