SINAMICS Siemens Controlss

Similar documents
SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Siemens Industrial s

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5A ST (6ES7132-4BD02-0AA0) Preface. Properties 2. Diagnostics 3.

DANGER indicates that death or severe personal injury will result if proper precautions are not taken.

SIMATIC. ET 200S distributed I/O Digital electronic module 4DO DC24V/0.5 A ST (6ES7132-4BD01-0AA0) Preface. Properties 1. Diagnostics 2.

DI 8x24VDC ST digital input module SIMATIC. ET 200SP DI 8x24VDC ST digital input module (6ES7131-6BF00-0BA0) Preface. Documentation guide

SIMOTION. SIMOTION SCOUT Task Trace. Preface 1. Overview 2. Configuring 3. Working with the SIMOTION Task Profiler. Function Manual 05/2009

ET 200S distributed I/O Digital electronic module 2DO AC V (6ES7132-4FB01-0AB0)

ET 200S distributed I/O system 4DO DC24V/2A ST digital electronic module (6ES7132-4BD32-0AA0)

ST (6ES7132-6FD00-0BB1)

Description. SIMATIC Sensors. RF systems Wide-range power supply unit for SIMATIC RF systems. Operating Instructions 11/2007 J31069-D0169-U001-A4-7618

First Steps in Commissioning CPU. 31xC: Positioning with digital output SIMATIC

Readme SiVArc V14 SP1 Update 6

Team engineering via Inter Project. Engineering. TIA Portal. Team engineering via Inter Project Engineering. Basics of "Inter Project Engineering"

Device manual SINAMICS SINAMICS G120. Distributed inverter box Control cabinet for wall or floor mounting.

SITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V/AC V (6ES7138-4CB11-0AB0) Preface. Properties 1. Parameters 2.

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

SINAMICS SINAMICS G120. Frequency inverter with Control Units CU240E-2 CU240E-2 DP CU240E-2 F CU240E-2 DP-F. Function Manual Safety Integrated 07/2010

Class documentation. COMOSKDictionary COMOS. Platform Class documentation COMOSKDictionary. Trademarks. General. KDictionary. Programming Manual

Power module PM-E DC24V/8A RO SIMATIC. ET 200S distributed I/O Power module PM-E DC24V/8A RO (6ES7138-4CA80-0AB0) Preface. Properties.

Power module PM-E DC24V HF SIMATIC. ET 200S distributed I/O Power module PM-E DC24V HF (6ES7138-4CA60-0AB0) Preface. Properties.

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

SIMATIC. ET 200S distributed I/O Power module PM-E DC24..48V (6ES7138-4CA50-0AB0) Preface. Properties 1. Parameters 2. Diagnostics 3.

Mechanical Installation Manual SINUMERIK. SINUMERIK 808D Mechanical Installation Manual. Preface. Safety instructions 1. Identification 2.

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

BaseUnits (6ES7193-6BP.../3RK1908-0AP00 ) SIMATIC. ET 200SP BaseUnits. Preface. Guide to the documentation 1. Product overview 2

Operating instructions. Standstill monitor A / / 2011

SIMATIC S Getting Started for First Time Users. Order No.: 6ZB5310-0NC02-0BA0 04/2007 A5E

Operating instructions for AX5801. TwinSAFE drive option card for the AX5000 servo drive. Version: Date:

SITOP UPS1600 under STEP 7 V13. SITOP UPS1600 under STEP 7 V13. Introduction. Safety notes. Description. Assigning the IP address

Product Information Mixed. Configuration ET 200SP / ET 200AL SIMATIC. ET 200SP Product Information Mixed Configuration ET 200SP / ET 200AL.

SIMATIC. ET 200S distributed I/O 2AO U ST analog electronic module (6ES7135-4FB01-0AB0) Preface. Properties 1. Parameters 2.

Converter SINAMICS G150. Type 6SL37102G

Original operating instructions Safety relay with relay outputs with and without delay G1502S / / 2016

SIMATIC. ET 200S distributed I/O 2AO U HF analog electronic module (6ES7135-4LB02-0AB0) Preface. Properties 1. Parameters 2.

SINAMICS G130. Cabinet design and EMC. Operating Instructions 03/2013 SINAMICS

SITOP UPS1600 under STEP 7 V5. SITOP UPS1600 under STEP 7 V5. Introduction. Safety notes. Description 3. Assigning the IP address

MindSphere. Visual Explorer. Introduction. User roles for "Visual Explorer" Connecting "Visual Explorer" to MindSphere data. Creating Visualizations

SIMATIC. ET 200SP Open Controller Product information on CPU 1515SP PC. Preface. Product Information. Technical update. Technical specifications 3

Digital output module. DQ 16x24VDC/0.5A BA (6ES7522-1BH10-0AA0) SIMATIC

CP 1623 SIMATIC NET. PG/PC - Industrial Ethernet CP Preface. Description of the device. Software installation. Hardware installation

SIMATIC. Digital Input Module SM DI, DC24V - Sinking/Sourcing. Product information. Product Information

Operating instructions. Speed monitor D / / 2014

COMOS. Platform Class documentation RevisionMaster_dll. Class: RevisionInfo 1. Class: RevisionMaster 2. Programming Manual

Creating the program. TIA Portal. SIMATIC Creating the program. Loading the block library 1. Deleting program block Main [OB1]

Validity 1. Improvements in STEP 7 2. Improvements in WinCC 3 SIMATIC. Readme. Readme

Manual Edition 03/2010

General Information 1. Connection 2. User Interface 3 ATC5300. Menus 4. Automatic Transfer Controller. Remote Control Software Manual A5E

Original operating instructions Safety relay with relay outputs G1501S / / 2016

SIMATIC Ident RFID systems MDS D423 Compact Operating Instructions

SIMATIC/SINAMICS. Getting started with SINAMICS V90 PN on S Motion Control. Fundamental safety instructions 1. Introduction

Siemens Drives & PLCs

SINAMICS. Safety. SINAMICS G120, G120C, G120D, G110M, SIMATIC ET 200pro FC-2 inverters. Function Manual

SIMATIC. S7/HMI SIMATIC Automation Tool V3.1 SP1 product information. SIMATIC Automation Tool features 1. Known problems. Product Information

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

AS-i Safety Relay Output Module with Diagnostic Slave

S7-300 Getting Started - Commissioning a CPU 31xC: Closed-loop control

AS-i Safety Relay Output Module with Diagnostic Slave

SINAMICS G120 SINAMICS G120C

SIMATIC. ET 200SP DQ 4x VAC/2A ST digital output module (6ES7132-6FD00-0BB1) Preface. Guide to documentation. Product overview.

Use with 0 to 70 C ambient. temperature SIMATIC. Process Control System PCS 7 Use with 0 to 70 C ambient temperature. Preface 1. Product combination 2

SIMATIC. Process Control System PCS 7 PCS 7 system documentation - Readme V8.0 SP2 (Update 1) Options for Accessing Documentation 1

SIMATIC. ET 200S distributed I/O. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Preface. 4 IQ-SENSE module (6ES7138-4GA00-0AB0) Parameters 2.

SMVector Additional I/O Module Installation and Operation Manual

Medium-Voltage Drive SINAMICS SM150. Type 6SL3845. Tests carried out on drives This documentation pertains to SM150 wassergekühlt G20 F03 F72 F79 F76

Setting up securityglobal FW Rulesets SIMATIC NET. Industrial Ethernet Security Setting up security. Preface. Firewall in standard mode

Getting Started - Startdrive. Startdrive SINAMICS. Introduction 1. Connecting the drive unit to the PC. Creating a project 3

SINAMICS S120. Getting Started 01/2013 SINAMICS

SIMATIC HMI. Software RemoteOperate V2. Preface. Overview 1. Range of functions of the RemoteOperate software. Hardware and software requirements

Siemens Spares. Setting up security in STEP 7. Professional SIMATIC NET. Industrial Ethernet Security Setting up security in STEP 7 Professional

7KM2112-0BA00-3AA0 SENTRON PAC3200. English. Operating Instructions DANGER CAUTION DANGER. Order-No.: A5E Last update: 18 January 2008

Options for ABB drives. User s manual Emergency stop, stop category 0 (option +Q951) for ACS880-07/17/37 drives

Siemens Automation Products

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

SIMATIC. Process Control System PCS 7 Product Brief on Software Updates from V5.1/V5.2 to PCS 7 V7.0 SP1. Preface 1

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

PROFIsafe SITRANS. Pressure transmitter SITRANS P, DS III PROFIsafe series. Product Information 7MF4*34 04/2008 A5E

Industrial Controls. Motor management and control devices SIMOCODE pro - Application examples. Introduction 1. Application example

SIMATIC. Process Control System PCS 7 VT Readme V8.2 (online) Security information 1. Overview 2. Notes on Installation 3. Notes on usage 4.

Options for ABB drives. User s manual Prevention of unexpected start-up (option +Q957) for ACS880-07/17/37 drives

SIMATIC. Communications processor CP First Steps in Commissioning. Getting Started 09/2008 A5E

SIMATIC. Process Control System PCS 7 PCS 7 Documentation (V8.1) Options for Accessing Documentation 1. Documentation for the Planning Phase 2

English. SIMATIC Sensors. RFID-Systems RF600. Getting Started. Edition 11/2005; J31069-D0172-U001-A1-7618

Operating instructions. Switching amplifier DN0210 DN / / 2015

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Digital ac/dc (24V) Input Module

Optional package printer driver V1.4

Operator Station (V8.0) SIMATIC. Process Control System PCS 7 Operator Station (V8.0) Preface 1. The PCS 7 Operator Station

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Options for ABB drives. User s manual Emergency stop, stop category 1 (option +Q964) for ACS880-07/17/37 drives

Safety technology with SINUMERIK Safety Integrated SINUMERIK. SINUMERIK 840D sl / 828D Safety technology with SINUMERIK Safety Integrated

Transcription:

SINAMICS G150 / S150 / S120 Cabinet Modules / G130 Operating Instructions 10/2008 SINAMICS Siemens Controlss

Preface Introduction 1 SINAMICS G150 / S150 / S120 Cabinet Modules / G130 Operating Instructions Option K82 2 Activation of "Safe Torque Off" and "Safe STOP 1" in the standard in SINAMICS G150 / S150 / S120 Cabinet Modules / G130 3 4 Valid for: Firmware version FW2.6 SP1 10/2008 A5E00746546A Siemens Controls

Legal information Warning notice system This manual contains notices you have to observe in order to ensure your personal safety, as well as to prevent damage to property. The notices referring to your personal safety are highlighted in the manual by a safety alert symbol, notices referring only to property damage have no safety alert symbol. These notices shown below are graded according to the degree of danger. DANGER indicates that death or severe personal injury will result if proper precautions are not taken. WARNING indicates that death or severe personal injury may result if proper precautions are not taken. CAUTION with a safety alert symbol, indicates that minor personal injury can result if proper precautions are not taken. CAUTION without a safety alert symbol, indicates that property damage can result if proper precautions are not taken. NOTICE indicates that an unintended result or situation can occur if the corresponding information is not taken into account. If more than one degree of danger is present, the warning notice representing the highest degree of danger will be used. A notice warning of injury to persons with a safety alert symbol may also include a warning relating to property damage. Qualified Personnel The device/system may only be set up and used in conjunction with this documentation. Commissioning and operation of a device/system may only be performed by qualified personnel. Within the context of the safety notes in this documentation qualified persons are defined as persons who are authorized to commission, ground and label devices, systems and circuits in accordance with established safety practices and standards. Proper use of Siemens products Note the following: WARNING Siemens products may only be used for the applications described in the catalog and in the relevant technical documentation. If products and components from other manufacturers are used, these must be recommended or approved by Siemens. Proper transport, storage, installation, assembly, commissioning, operation and maintenance are required to ensure that the products operate safely and without any problems. The permissible ambient conditions must be adhered to. The information in the relevant documentation must be observed. Trademarks All names identified by are registered trademarks of the Siemens AG. The remaining trademarks in this publication may be trademarks whose use by third parties for their own purposes could violate the rights of the owner. Disclaimer of Liability We have reviewed the contents of this publication to ensure consistency with the hardware and software described. Since variance cannot be precluded entirely, we cannot guarantee full consistency. However, the information in this publication is reviewed regularly and any necessary corrections are included in subsequent editions. Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG GERMANY A5E00746546A P 04/2009 Copyright Siemens AG 2008. Technical data subject to change

Preface Technical Support In case of questions, please contact us through the following hotline: Time zone Europe / Africa Phone +49 180 5050-222 Fax +49 180 5050-223 0.14/min. from German landlines, mobile phone prices may differ Internet http://www.siemens.de/automation/support-request Time zone Americas Phone +1 423 262 2522 Fax +1 423 262 2200 E-mail mailto:techsupport.sea@siemens.com Time zone Asia and Australia Phone +86 1064 757 575 Fax +86 1064 747 474 E-mail mailto:support.asia.automation@siemens.com Note Country-specific telephone numbers for technical support are provided under the following Internet address: http://www.siemens.com/automation/service&support Spare parts You will find spare parts on the Internet at: http://support.automation.siemens.com/ww/view/en/16612315. Internet address for SINAMICS http://www.siemens.com/sinamics. Siemens Controls Operating Instructions, 10/2008, A5E00746546A 5

Preface Notation The following notation and abbreviations are used in this documentation: Notation for parameters (examples): p0918 Adjustable parameter 918 r1024 Display parameter 1024 p1070[1] Adjustable parameter 1070, index 1 p2098[1].3 Adjustable parameter 2098, index 1, bit 3 p0099[0...3] Adjustable parameter 99 indices 0 to 3 r0945[2](3) Display parameter 945 index 2 of drive object 3 p0795.4 Adjustable parameter 795 bit 4 Notation for faults and alarms (examples): F12345 Fault 12345 A67890 Alarm 67890 C01700 Safety alarm 1700 ESD information CAUTION Electrostatic sensitive devices (ESD) are single components, integrated circuits or devices that can be damaged by electrostatic fields or electrostatic discharges. Regulations for the ESD handling: During the handling of electronic components, pay attention to the grounding of the person, workplace and packaging! Electronic components may be touched by persons only when these persons are grounded using an ESD bracelet, or these persons in ESD areas with a conducting floor wear ESD shoes or ESD grounding straps. Electronic components should be touched only when this is unavoidable. The touching is permitted only on the front panel or on the circuit board edge. Electronic components must not be brought into contact with plastics or clothing made of artificial fibers. Electronic components may only be placed on conducting surfaces (table with ESD coating, conducting ESD foamed material, ESD packing bag, ESD transport container). Electronic components may not be placed near display units, monitors or televisions (minimum distance from the screen > 10 cm). Measurements must only be taken on boards when the measuring instrument is grounded (via protective conductors, for example) or the measuring probe is briefly discharged before measurements are taken with an isolated measuring device (for example, touching a bare metal housing). 6 Operating Instructions, 10/2008, A5E00746546A

Preface Safety notices DANGER Commissioning must not start until you have ensured that the machine in which the components described here are to be installed complies with Directive 98/37/EC. SINAMICS devices and AC motors must only be commissioned by suitably qualified personnel. The personnel must take into account the information provided in the technical customer documentation for the product, and be familiar with and follow the specified danger and warning notices. When electrical equipment and motors are operated, the electrical circuits automatically conduct a dangerous voltage. When the machine or system is operated, hazardous axis movements can occur. All of the work carried-out on the electrical machine or system must be carried-out with it in a no-voltage condition. DANGER Five safety rules When carrying out any kind of work on electrical devices, the "five safety rules" must always be observed: 1. Disconnect the system. 2. Protect against reconnection. 3. Make sure that the equipment is de-energized. 4. Ground and short-circuit. 5. Cover or enclose adjacent components that are still live. WARNING Correct and safe operation of SINAMICS units assumes correct transportation in the transport packaging, correct long-term storage in the transport packaging, setup and installation, as well as careful operation and maintenance. For special versions of the drive units and motors, information and data in the Catalogs and quotations additionally apply. In addition to the danger and warning information provided in the technical customer documentation, the applicable national, local, and plant-specific regulations and requirements must be taken into account. According to EN 61800-5-1 and UL 508, only safely isolated protective extra-low voltages on the electronic modules may be connected to any of the terminals on the electronic modules. Siemens Controls Operating Instructions, 10/2008, A5E00746546A 7

Preface CAUTION The motors can have surface temperatures of over +80 C. This is the reason that temperature-sensitive components, e.g. cables or electronic components may neither be in contact nor be attached to the motor. When attaching the connecting cables, you must ensure that: they may not be damaged, they may not be stressed, they may not be able to come into contact with any rotating parts Note In the configuration specified in the corresponding EC Declaration of Conformity regarding EMC requirements and when the EMC installation guideline (order no. 6FC5297-0AD30-0*P2) is observed, SINAMICS devices conform to EMC Directive 89/336/EEC and 2004/108/EC. (*A: German; *B: English) Note When operated in dry operating areas, SINAMICS equipment with AC motors conforms to Low-Voltage Directive 2006/95/EC. CAUTION Operating the equipment in the immediate vicinity (< 1.5 m) of mobile telephones with a transmitter power of > 1 W may lead to incorrect operation. Safety notes on DANGER High voltages The drive is not disconnected from the mains by the "Safe Torque Off" function. Dangerous voltages may be present on the motor and converter. This can result in death, serious personal injury or severe material damage. Work on the electrical connections is not allowed. 8 Operating Instructions, 10/2008, A5E00746546A

Preface DANGER Unexpected start up of the drive If the function "Safe Torque Off" is not checked for proper function after service work, then the drive can also start up unexpectedly after activating the "Safe Torque Off" function. This can result in death, serious personal injury or severe material damage. Upon conclusion of service work on all components with safety function (e.g., replacement of components), you must verify and document proper function through a test activation. DANGER Restart Drive systems, in which power supply to the motor is also possible via the load (e.g., ship's drives, conveyors, fans, etc.) cannot be protected against restart using the "Safe Torque Off" function. This can result in death, serious personal injury or severe material damage. Take appropriate countermeasures such as mechanical braking. WARNING Only circuits that have been manufactured by I DT LD or by certified factories or that have been installed by I DT LD Service for option K82 possess an approval. Possible plant-side reproductions by non-certified manufacturers do not possess this approval! An up-to-date list of authorized factories is available on request from your local Siemens office. WARNING Unexpected start up of the drive If the function "Safe Torque Off" is deactivated, the drive can start up unexpectedly. This can result in death, serious personal injury or severe material damage. To demonstrate that the function "Safe Torque Off" is deactivated, the specified switches (e.g., "Safe Torque Off" mushroom-head pushbutton on the system) must be removed. Note The components must be protected against conductive pollution (e.g., using a cabinet with IP54 protection). Provided that conducted interference can be prevented at the installation site, the degree of protection for the cabinet can be decreased accordingly. Siemens Controls Operating Instructions, 10/2008, A5E00746546A 9

Preface 10 Operating Instructions, 10/2008, A5E00746546A

Table of contents Preface... 5 1 Introduction... 13 2 Option K82... 15 2.1 SINAMICS G150...15 2.1.1 Terminal module for activation of "Safe Torque Off" and "Safe STOP 1" (option K82)...15 2.2 SINAMICS S150...20 2.2.1 Terminal module for activation of "Safe Torque Off" and "Safe STOP 1" (option K82)...20 2.3 SINAMICS S120 Cabinet Modules...25 2.3.1 Terminal module for activation of "Safe Torque Off" and "Safe STOP 1" (option K82)...25 2.3.2 Use of option K82 in conjunction with option K90/K91 (CU320 control unit + a CompactFlash card with/without performance expansion)...29 2.3.3 Use of option K82 without option K90/K91 (CU320 control unit + a CompactFlash card with/without performance expansion)...29 2.3.4 Wiring...29 3 Activation of "Safe Torque Off" and "Safe STOP 1" in the standard... 31 3.1 SINAMICS G150...31 3.1.1 Activation of "Safe Torque Off" and "Safe STOP 1"...31 3.2 SINAMICS S150...37 3.2.1 Activation of "Safe Torque Off" and "Safe STOP 1"...37 3.3 SINAMICS S120 Cabinet Modules...42 3.3.1 Activation of "Safe Torque Off" and "Safe STOP 1"...42 3.4 SINAMICS G130...47 3.4.1 Activation of "Safe Torque Off" and "Safe Stop 1"...47 4 in SINAMICS G150 / S150 / S120 Cabinet Modules / G130... 53 4.1 General information about SINAMICS...53 4.1.1 Introduction...53 4.1.2 Supported functions...55 4.1.3 Parameter, Checksum, Version, Password...55 4.2 System features...59 4.2.1 Certification...59 4.2.2 Safety instructions...59 4.2.3 Probability of failure of the safety functions (PFH value)...61 4.2.4 Residual risk...61 4.2.5 Response times...61 4.3 Functions...62 4.3.1 Safe Torque Off (STO)...62 4.3.2 Safe Stop 1 (SS1, time controlled)...64 4.3.3 Forced checking procedure...66 4.4 Control of the safety functions...66 4.5 Commissioning...67 4.5.1 General information about commissioning safety functions...67 Siemens Controls Operating Instructions, 10/2008, A5E00746546A 11

Table of contents 4.5.2 Procedure for commissioning "STO" and "SS1"... 69 4.5.3 Safety faults... 72 4.6 Acceptance test and certificate... 74 4.6.1 General information about acceptance... 74 4.6.2 Safety logbook... 76 4.6.3 Acceptance certificate... 76 4.6.3.1 Documentation... 77 4.6.3.2 Acceptance test for Safe Torque Off (STO)... 80 4.6.3.3 Acceptance test for Safe Stop 1, time controlled (SS1)... 82 4.6.4 Completion of certificate... 84 4.7 Overview of parameters and function diagrams... 85 Index... 87 12 Operating Instructions, 10/2008, A5E00746546A

Introduction 1 This book describes the available interface modules for activating the "Safe Torque Off" and "Safe Stop 1" safety functions, as well as the commissioning and acceptance procedures for them. Option K82 The K82 option (terminal module for activating "Safe Torque Off" and "Safe Stop 1" is used for optically isolated activation via a variable control voltage range of the safety functions already present in the standard, which can also be used without option K82. Recommended application This option is used when: Activation will be executed optically isolated in a voltage range of 24 V 230 V DC/AC. You will be working with non-shielded control lines with lengths greater than 30 m. The devices will be used in plants with greater spatial elongation (ideal PA not present). Activation of "Safe Torque Off" and "Safe Stop 1" in the standard The activation of the safety functions already contained in the standard (i.e., "Safe Torque Off" and "Safe Stop 1") can also be used without option K82. Recommended application This variant is used when: Activation will be executed optically isolated with a voltage of 24 V DC. Working with control lines which are shorter than 30 m. When devices are used in plants with low spatial elongation (watch out for the drop in voltage at 24 V DC!). Siemens Controls Operating Instructions, 10/2008, A5E00746546A 13

Introduction 14 Operating Instructions, 10/2008, A5E00746546A

Option K82 2 2.1 SINAMICS G150 2.1.1 Terminal module for activation of "Safe Torque Off" and "Safe STOP 1" (option K82) Description The K82 option (terminal module for activating "Safe Torque Off" and "Safe Stop 1" is used for optically isolated activation via a variable control voltage range of the safety functions already present in the standard, which can also be used without option K82. Note Refer to the circuit diagrams enclosed for the interconnections for your device. Note The Safety functions must be activated prior to use via parameter assignment. An acceptance test must be performed and an acceptance log must be created. Option K82 is used to activate the following functions (terms and definitions in accordance with IEC 61800-5-2): Safe Torque Off (STO) Safe Stop 1 (SS1, time-controlled) Note The integrated safety functions, starting from the (SI) input terminals of the SINAMICS components (Control Unit, Power Module), satisfy the requirements in accordance with the equipment directive 98/37/EC, the EN 60204-1, DIN EN ISO 13849-1 category 3 (formerly EN954-1) as well as the requirements for Performance Level (PL) d and IEC 61508 SIL2. In combination with the option K82, the requirements specified in machinery directive 98/37/EC, EN 60204-1 as well as in DIN EN ISO 13849-1 category 3 (formerly EN954-1) are satisfied for Performance Level (PL) d and IEC 61508 SIL2. In addition, most of the safety functions of the SINAMICS have been certified by independent institutes. An up-to-date list of certified components is available on request from your local Siemens office. Siemens Controls Operating Instructions, 10/2008, A5E00746546A 15

Option K82 2.1 SINAMICS G150 Recommended application This option is used when: Activation will be executed optically isolated in a voltage range of 24 V 230 V DC/AC. You will be working with non-shielded control lines with lengths greater than 30 m. The devices will be used in plants with greater spatial elongation (ideal PA not present). Functional principle Two independent channels of the integrated safety function are activated via the relays (K41, K42). The relay K41 activates the signal to the control unit that is necessary for the safety function and the relay K42 on the Power Module. The selection and deselection must be executed concurrently. The time delay that is unavoidable due to mechanical switch processes, for instance, can be adapted via parameters. The circuit is structured so that it is protected against wire break, i.e. if the relay's control voltage fails then the safety function is active. A checkback signal can be derived for information, diagnostics, or troubleshooting from the normally-closed contact switched in series of the relay. Wiring of the checkback signal can be executed optionally and is not part of the safety concept. Note The checkback signal is not necessary for compliance with the standard DIN EN ISO 13849-1 (formerly EN-954-1) cat. 3 PL d and DIN EN 61508 SIL2. The selection of the safety function must be executed over two channels. A switch in accordance with ISO ISO 13850/ EN 418, positive opening in accordance with EC 60947-5- 1, or a certified safety controller must be used as activation element. DANGER Responsibility for selecting the correct activation element for the purpose of compliance of the overall system with the required standard (DIN EN ISO 13849-1 (formerly EN-954-1) Cat. 3 PL d or DIN EN 61508 SIL2) rests with the user. 16 Operating Instructions, 10/2008, A5E00746546A

Option K82 2.1 SINAMICS G150 Customer interface X41 Table 2-1 Terminal strip -X41 Terminal Meaning Technical data -X41:1 Activation K41: A1 Connection for activation element at channel 1 "+" -X41:2 Connected to -X41:1 -X41:3 Activation K41:A2, -K42:A2, N conductor or ground Connection of reference potential for activation elements at channel 1 and channel 2 -X41:4 Connected to -X41:3 -X41:5 Checkback signal, status K41, -K42 Connection of supply voltage for optional checkback signal -X41:6 Checkback signal, status K41, -K42 Connection of optional checkback signal -X41:7 Activation K42: A1 Connection for activation element at channel 2 "+" -X41:8 Connected to -X41:7 -X41:9 Not assigned -X41:10 Output -K41: Permanently wired with CU320: X132:4 (DI7) Control circuit: Rated voltage: 24-230 V DC/AC (0.85 1.1 x Us) Max. line length (applies to total of current and return conductors): AC (line capacity: 300 pf/m): 24 V: 5,000 m 110 V: 800 m 230 V: 200 m The values apply for 50 Hz, at 60 Hz the line lengths must be reduced by 20%. WARNING If the permissible cable lengths and/or the permissible cable capacity is exceeded, then due to the couple capacity of the cable and the associated residual current it may be the case that the relay remains tightened in spite of opened activation element. DC (min. cross-section 0.75 mm²): 1500 m Max. connectable cross-section: 2.5 mm² Fuse: max. 4 A Siemens Controls Operating Instructions, 10/2008, A5E00746546A 17

Option K82 2.1 SINAMICS G150 Load side: Operational voltage: max. 250 V DC/AC Rated operating currents: AC-15 (in accordance with IEC 60947-5-1): 24-230 V = 3 A DC-13 (in accordance with IEC 60947-5-1): 24 V = 1 A 10 V = 0.2 A 230 V = 0.1 A Min. contact load: 5 V DC, 1 ma at 1 ppm error Fuse: max. 4 A (fuse weld-free, duty category gl/gg with Ik 1 ka) P EP+ P24 V M EP M 1 EP + -X 42: 8 7 -X 41: 1 2 14 32 A1 12 22 24 34 -K41 A2 21 11 31 A1 -K42 A2 11 14 32 22 24 12 34 21 31 -X99: 9 -X99: 10 -X41 10 1 2 3 4 7 8 5 6 9 Figure 2-1 Circuit terminal module for option K82 A switch in accordance with ISO ISO 13850/ EN 418, positive opening in accordance with EC 60947-5-1, or a certified safety controller must be used as activation element. Note The terminal -X41:10 is permanently connected to the digital input DI7. 18 Operating Instructions, 10/2008, A5E00746546A

Option K82 2.1 SINAMICS G150 Note For the following cabinet units (automatic synchronizers), the digital input DI6 is also used: For 380 V 480 V 3 AC: 6SL3710-2GE41-1AA0, 6SL3710-2GE41-4AA0, 6SL3710-2GE41-6AA0 For 500 V 600 V 3 AC: 6SL3710-2GF38-6AA0, 6SL3710-2GF41-1AA0, 6SL3710-2GF41-4AA0 For 660 V 690 V 3 AC: 6SL3710-2GH41-1AA0, 6SL3710-2GH41-4AA0, 6SL3710-2GH41-5AA0 Interconnection in groups When using a single activation element for multiple cabinet units, the following terminals have to be used on terminal strip -X41: -X41:2: Interconnection to the next cabinet unit, terminal -X41:1 -X41:4: Interconnection to the next cabinet unit, terminal -X41:3 -X41:6: Interconnection to the next cabinet unit, terminal -X41:5 -X41:8: Interconnection to the next cabinet unit, terminal -X41:7 -X41:9: Interconnection to the next cabinet unit, terminal -X41:6 Connection of the optional checkback signal to terminal -X41:9 Wiring The control lines must be permanently laid. Signal cables and encoder cables should be installed separated from one another. The shields of the control lines must be wide-area grounded directly after entry into the control cabinet. Outside the cabinet unit the cables must be laid in such a way that they are safe to walk on (e.g., conforming to IEC 60204-1). Siemens Controls Operating Instructions, 10/2008, A5E00746546A 19

Option K82 2.2 SINAMICS S150 2.2 SINAMICS S150 2.2.1 Terminal module for activation of "Safe Torque Off" and "Safe STOP 1" (option K82) Description The K82 option (terminal module for activating "Safe Torque Off" and "Safe Stop 1" is used for optically isolated activation via a variable control voltage range of the safety functions already present in the standard, which can also be used without option K82. Note Refer to the circuit diagrams enclosed for the interconnections for your device. Note The Safety functions must be activated prior to use via parameter assignment. An acceptance test must be performed and an acceptance log must be created. Option K82 is used to activate the following functions (terms and definitions in accordance with IEC 61800-5-2): Safe Torque Off (STO) Safe Stop 1 (SS1, time-controlled) Note The integrated safety functions, starting from the (SI) input terminals of the SINAMICS components (Control Unit, Motor Module), satisfy the requirements in accordance with the equipment directive 98/37/EC, the EN 60204-1, DIN EN ISO 13849-1 category 3 (formerly EN954-1) as well as the requirements for Performance Level (PL) d and IEC 61508 SIL2. In combination with the option K82, the requirements specified in machinery directive 98/37/EC, EN 60204-1 as well as in DIN EN ISO 13849-1 category 3 (formerly EN954-1) are satisfied for Performance Level (PL) d and IEC 61508 SIL2. In addition, most of the safety functions of the SINAMICS have been certified by independent institutes. An up-to-date list of certified components is available on request from your local Siemens office. 20 Operating Instructions, 10/2008, A5E00746546A

Option K82 2.2 SINAMICS S150 Recommended application This option is used when: Activation will be executed optically isolated in a voltage range of 24 V 230 V DC/AC. You will be working with non-shielded control lines with lengths greater than 30 m. The devices will be used in plants with greater spatial elongation (ideal PA not present). Functional principle Two independent channels of the integrated safety function are activated via the relays (K41, K42). Relay K41 activates the signal to the control unit that is necessary for the safety function and the relay K42 on the Motor Module. The selection and deselection must be executed concurrently. The time delay that is unavoidable due to mechanical switch processes, for instance, can be adapted via parameters. The circuit is structured so that it is protected against wire break, i.e. if the relay's control voltage fails then the safety function is active. A checkback signal can be derived for information, diagnostics, or troubleshooting from the normally-closed contact switched in series of the relay. Wiring of the checkback signal can be executed optionally and is not part of the safety concept. Note The checkback signal is not necessary for compliance with the standard DIN EN ISO 13849-1 (formerly EN-954-1) cat. 3 PL d and DIN EN 61508 SIL2. The selection of the safety function must be executed over two channels. A switch in accordance with ISO ISO 13850/ EN 418, positive opening in accordance with EC 60947-5- 1, or a certified safety controller must be used as activation element. DANGER Responsibility for selecting the correct activation element for the purpose of compliance of the overall system with the required standard (DIN EN ISO 13849-1 (formerly EN-954-1) Cat. 3 PL d or DIN EN 61508 SIL2) rests with the user. Siemens Controls Operating Instructions, 10/2008, A5E00746546A 21

Option K82 2.2 SINAMICS S150 Customer interface X41 Table 2-2 Terminal strip -X41 Terminal Meaning Technical data -X41:1 Activation K41: A1 Connection for activation element at channel 1 "+" -X41:2 -X41:3 Connected to -X41:1 Activation K41:A2, -K42:A2, N conductor or ground Connection of reference potential for activation elements at channel 1 and channel 2 -X41:4 Connected to -X41:3 -X41:5 Checkback signal, status K41, -K42 Connection of supply voltage for optional checkback signal -X41:6 Checkback signal, status K41, -K42 Connection of optional checkback signal -X41:7 Activation K42: A1 Connection for activation element at channel 2 "+" -X41:8 Connected to -X41:7 -X41:9 Not assigned -X41:10 Output -K41: Permanently wired with CU320: X132:4 (DI7) Control circuit: Rated voltage: 24-230 V DC/AC (0.85 1.1 x Us) Max. line length (applies to total of current and return conductors): AC (line capacity: 300 pf/m): 24 V: 5,000 m 110 V: 800 m 230 V: 200 m The values apply for 50 Hz, at 60 Hz the line lengths must be reduced by 20%. WARNING If the permissible cable lengths and/or the permissible cable capacity is exceeded, then due to the couple capacity of the cable and the associated residual current it may be the case that the relay remains tightened in spite of opened activation element. DC (min. cross-section 0.75 mm²): 1500 m Max. connectable cross-section: 2.5 mm² Fuse: max. 4 A 22 Operating Instructions, 10/2008, A5E00746546A

Option K82 2.2 SINAMICS S150 Load side: Operational voltage: max. 250 V DC/AC Rated operating currents: AC-15 (in accordance with IEC 60947-5-1): 24-230 V = 3 A DC-13 (in accordance with IEC 60947-5-1): 24 V = 1 A 10 V = 0.2 A 230 V = 0.1 A Min. contact load: 5 V DC, 1 ma at 1 ppm error Fuse: max. 4 A (fuse weld-free, duty category gl/gg with Ik 1 ka) P EP+ 14 32 A1 12 22 24 34 -K41 A2 21 11 31 A1 -K42 A2 11 14 32 22 24 12 34 21 31 -X41 10 1 2 3 4 7 8 5 6 9 Figure 2-2 Circuit terminal module for option K82 A switch in accordance with ISO ISO 13850/ EN 418, positive opening in accordance with EC 60947-5-1, or a certified safety controller must be used as activation element. Note The terminal -X41:10 is permanently connected to the digital input DI7. Siemens Controls Operating Instructions, 10/2008, A5E00746546A 23

Option K82 2.2 SINAMICS S150 Interconnection in groups When using a single activation element for multiple cabinet units, the following terminals have to be used on terminal strip -X41: -X41:2: Interconnection to the next cabinet unit, terminal -X41:1 -X41:4: Interconnection to the next cabinet unit, terminal -X41:3 -X41:6: Interconnection to the next cabinet unit, terminal -X41:5 -X41:8: Interconnection to the next cabinet unit, terminal -X41:7 -X41:9: Interconnection to the next cabinet unit, terminal -X41:6 Connection of the optional checkback signal to terminal -X41:9 Wiring The control lines must be permanently laid. Signal cables and encoder cables should be installed separated from one another. The shields of the control lines must be wide-area grounded directly after entry into the control cabinet. Outside the cabinet unit the cables must be laid in such a way that they are safe to walk on (e.g., conforming to IEC 60204-1). 24 Operating Instructions, 10/2008, A5E00746546A

Option K82 2.3 SINAMICS S120 Cabinet Modules 2.3 SINAMICS S120 Cabinet Modules 2.3.1 Terminal module for activation of "Safe Torque Off" and "Safe STOP 1" (option K82) Availability of option This option is available for the following S120 cabinet modules: Chassis Motor Module Booksize Cabinet Kit Description The K82 option (terminal module for activating "Safe Torque Off" and "Safe STOP 1" is used for optically isolated activation via a variable control voltage range of the safety functions already present in the standard, which can also be used without option K82. Note Refer to the circuit diagrams enclosed for the interconnections for your device. Note The Safety functions must be activated prior to use via parameter assignment. An acceptance test must be performed and an acceptance log must be created. Option K82 is used to activate the following functions (terms and definitions in accordance with IEC 61800-5-2): Safe Torque Off (STO) Safe Stop 1 (SS1, time-controlled) Note The integrated safety functions, starting from the (SI) input terminals of the SINAMICS components (Control Unit, Motor Module), satisfy the requirements in accordance with the equipment directive 98/37/EC, the EN 60204-1, DIN EN ISO 13849-1 category 3 (formerly EN954-1) as well as the requirements for Performance Level (PL) d and IEC 61508 SIL2. In combination with the option K82, the requirements specified in machinery directive 98/37/EC, EN 60204-1 as well as in DIN EN ISO 13849-1 category 3 (formerly EN954-1) are satisfied for Performance Level (PL) d and IEC 61508 SIL2. In addition, most of the safety functions of the SINAMICS have been certified by independent institutes. An up-to-date list of certified components is available on request from your local Siemens office. Siemens Controls Operating Instructions, 10/2008, A5E00746546A 25

Option K82 2.3 SINAMICS S120 Cabinet Modules Recommended application This option is used when: Activation will be executed optically isolated in a voltage range of 24 V 230 V DC/AC. You will be working with non-shielded control lines with lengths greater than 30 m. The devices will be used in plants with greater spatial elongation (ideal PA not present). Functional principle Two independent channels of the integrated safety function are activated via the relays (K41, K42). Relay K41 activates the signal to the control unit that is necessary for the safety function and the relay K42 on the Motor Module. The selection and deselection must be executed concurrently. The time delay that is unavoidable due to mechanical switch processes, for instance, can be adapted via parameters. The circuit is structured so that it is protected against wire break, i.e. if the relay's control voltage fails then the safety function is active. A checkback signal can be derived for information, diagnostics, or troubleshooting from the normally-closed contact switched in series of the relay. Wiring of the checkback signal can be executed optionally and is not part of the safety concept. Note The checkback signal is not necessary for compliance with the standard DIN EN ISO 13849-1 (formerly EN-954-1) cat. 3 PL d and DIN EN 61508 SIL2. The selection of the safety function must be executed over two channels. A switch in accordance with ISO ISO 13850/ EN 418, positive opening in accordance with EC 60947-5- 1, or a certified safety controller must be used as activation element. DANGER Responsibility for selecting the correct activation element for the purpose of compliance of the overall system with the required standard (DIN EN ISO 13849-1 (formerly EN-954-1) Cat. 3 PL d or DIN EN 61508 SIL2) rests with the user. 26 Operating Instructions, 10/2008, A5E00746546A

Option K82 2.3 SINAMICS S120 Cabinet Modules Customer interface X41 Table 2-3 Terminal strip -X41 Terminal Meaning Technical data -X41:1 Activation K41: A1 Connection for activation element at channel 1 "+" -X41:2 Connected to -X41:1 Connection for activation element at channel 1 "+", for interconnecting motor modules in groups -X41:3 Activation K41:A2, -K42:A2, N conductor or ground Connection of reference potential for activation elements at channel 1 and channel 2 -X41:4 Connected to -X41:3 Connection of reference potential for activation elements at channel 1 and channel 2, for interconnecting motor modules in groups -X41:5 Checkback signal, status K41, -K42 Connection of supply voltage for optional checkback signal -X41:6 Checkback signal, status K41, -K42 Connection for optional checkback signal, for interconnecting motor modules in groups -X41:7 Activation K42: A1 Connection for activation element at channel 2 "+" -X41:8 Connected to -X41:7 Connection for activation element at channel 2 "+", for interconnecting motor modules in groups -X41:9 Connection of optional checkback For the option of connecting other checkback signals in series when motor modules are grouped -X41:10 Output -K41: Permanently wired with CU320: X132:4 (DI7) Control circuit: Rated voltage: 24-230 V DC/AC (0.85 1.1 x Us) Max. line length (applies to total of current and return conductors): Output -K41: For connecting to a digital input in accordance with the Safety settings on the CU320 (already wired in option K90/91) AC (line capacity: 300 pf/m): 24 V: 5,000 m 110 V: 800 m 230 V: 200 m The values apply for 50 Hz, at 60 Hz the line lengths must be reduced by 20%. WARNING If the permissible cable lengths and/or the permissible cable capacity is exceeded, then due to the couple capacity of the cable and the associated residual current it may be the case that the relay remains tightened in spite of opened activation element. DC (min. cross-section 0.75 mm 2 ): 1500 m Max. connectable cross-section: 2.5 mm² Fuse: max. 4 A Siemens Controls Operating Instructions, 10/2008, A5E00746546A 27

Option K82 2.3 SINAMICS S120 Cabinet Modules Load side: Operational voltage: max. 250 V DC/AC Rated operating currents: AC-15 (in accordance with IEC 60947-5-1): 24-230 V = 3 A DC-13 (in accordance with IEC 60947-5-1): 24 V = 1 A 10 V = 0.2 A 230 V = 0.1 A Min. contact load: 5 V DC, 1 ma at 1 ppm error Fuse: max. 4 A (fuse weld-free, duty category gl/gg with Ik 1 ka) P EP+ 14 32 A1 12 22 24 34 -K41 A2 21 11 31 A1 -K42 A2 11 14 32 22 24 12 34 21 31 -X41 10 1 2 3 4 7 8 5 6 9 Figure 2-3 Circuit terminal module for option K82 A switch in accordance with ISO ISO 13850/ EN 418, positive opening in accordance with EC 60947-5-1, or a certified safety controller must be used as activation element. 28 Operating Instructions, 10/2008, A5E00746546A

Option K82 2.3 SINAMICS S120 Cabinet Modules 2.3.2 Use of option K82 in conjunction with option K90/K91 (CU320 control unit + a CompactFlash card with/without performance expansion) In conjunction with option K90/K91 (CU320), terminal -X41:10 is already connected to digital input DI7 in the CU320 within the cabinet. In the double motor module, digital input DI6 is also wired on the CU320. These interconnections have to be taken into account when Safety function parameters are assigned. 2.3.3 Use of option K82 without option K90/K91 (CU320 control unit + a CompactFlash card with/without performance expansion) If option K90/K91 is not present, connect terminal -X41:10 to each Motor Module's Control Unit. Digital inputs DI0 DI7 are available for this purpose. These interconnections have to be taken into account when Safety function parameters are assigned. If the line is laid to the control unit outside the cabinet unit, the cable may not be any more than 30 m in length. For longer line lengths, suitable protective circuitry must be provided on the plant side for overvoltage protection (Weidmüller: Type no.: MCZ OVP TAZ). Note Terminal -X41:10 may only be connected to digital inputs DI0...DI7; other digital inputs are not configurable. 2.3.4 Wiring The control lines must be permanently laid. Signal cables and encoder cables should be installed separated from one another. The shields of the control lines must be wide-area grounded directly after entry into the control cabinet. Outside the cabinet unit the cables must be laid in such a way that they are safe to walk on (e.g., conforming to IEC 60204-1). Siemens Controls Operating Instructions, 10/2008, A5E00746546A 29

Option K82 2.3 SINAMICS S120 Cabinet Modules 30 Operating Instructions, 10/2008, A5E00746546A

Activation of "Safe Torque Off" and "Safe STOP 1" in the standard 3 3.1 SINAMICS G150 3.1.1 Activation of "Safe Torque Off" and "Safe STOP 1" Description The activation of the safety functions already contained in the standard (i.e., "Safe Torque Off" and "Safe Stop 1") can also be used without option K82. Note Refer to the circuit diagrams enclosed for the interconnections for your device. Note The Safety functions must be activated prior to use via parameter assignment. An acceptance test must be performed and an acceptance log must be created. The following functions (terms and definitions in accordance with IEC 61800-5-2) can be activated: Safe Torque Off (STO) Safe Stop 1 (SS1, time-controlled) Note The integrated safety functions, starting from the (SI) input terminals of the SINAMICS components (Control Unit, Power Module), satisfy the requirements in accordance with the equipment directive 98/37/EC, the EN 60204-1, DIN EN ISO 13849-1 category 3 (formerly EN954-1) as well as the requirements for Performance Level (PL) d and IEC 61508 SIL2. In addition, most of the safety functions of the SINAMICS have been certified by independent institutes. An up-to-date list of certified components is available on request from your local Siemens office. Siemens Controls Operating Instructions, 10/2008, A5E00746546A 31

Activation of "Safe Torque Off" and "Safe STOP 1" in the standard 3.1 SINAMICS G150 Recommended application This variant is used when: Activation will be executed optically isolated with a voltage of 24 V DC. Working with control lines which are shorter than 30 m. When devices are used in plants with low spatial elongation (watch out for the drop in voltage at 24 V DC!). Functional principle The first shutdown path for the integrated safety functions is activated via a digital input on the control unit; digital inputs DI0 to DI7 are available for this purpose. The second shutdown path for the integrated safety functions is activated via the terminals (- X41:1, -X42:2) on the Control Interface Board of the Power Module. Note Additional inputs must be activated in the following cabinet units (automatic synchronizers): - an additional digital input on the CU320 and - the terminals (-X41:1, -X42:2) on the Control Interface Board of the second Power Module, which is connected in parallel. For 380 V 480 V 3 AC: 6SL3710-2GE41-1AA0, 6SL3710-2GE41-4AA0, 6SL3710-2GE41-6AA0 For 500 V 600 V 3 AC: 6SL3710-2GF38-6AA0, 6SL3710-2GF41-1AA0, 6SL3710-2GF41-4AA0 For 660 V 690 V 3 AC: 6SL3710-2GH41-1AA0, 6SL3710-2GH41-4AA0, 6SL3710-2GH41-5AA0 The selection and deselection must be executed concurrently. The time delay that is unavoidable due to mechanical switch processes, for instance, can be adapted via parameters. The selection of the safety function on the Control Unit and on the Control Interface Board of the Power Module must be executed over two channels. A switch in accordance with ISO ISO 13850/ EN 418, positive opening in accordance with EC 60947-5-1, or a certified safety controller must be used as activation element. DANGER Responsibility for selecting the correct activation element for the purpose of compliance of the overall system with the required standard (DIN EN ISO 13849-1 (formerly EN-954-1) Cat. 3 PL d or DIN EN 61508 SIL2) rests with the user. 32 Operating Instructions, 10/2008, A5E00746546A

Activation of "Safe Torque Off" and "Safe STOP 1" in the standard 3.1 SINAMICS G150 Terminal strip X41 on the Control Interface Board of the Power Module Table 3-1 Terminal strip X41 on the Control Interface Board of the Power Module Terminal Function Technical data -X41:2 EP +24V (enable pulses) -X41:1 EP M1 (Enable Pulses) Supply voltage: 24 V DC (20.4 V - 28.8 V) Power consumption: 10 ma Signal propagation times: L H 100 µs H L: 1000 µs Siemens Controls Operating Instructions, 10/2008, A5E00746546A 33

Activation of "Safe Torque Off" and "Safe STOP 1" in the standard 3.1 SINAMICS G150 Terminal strip X122 on the CU320 control unit Table 3-2 Terminal strip X122 on the CU320 control unit Terminal Designation 1) Technical data 1 DI 0 2 DI 1 3 DI 2 4 DI 3 5 M1 6 M 7 DI/DO 8 8 DI/DO 9 9 M 10 DI/DO 10 11 DI/DO 11 12 M Max. connectable cross-section: 0.5 mm 2 Type: Spring-loaded terminal Voltage: -3 V to 30 V Typical current consumption: 10 ma at 24 V DC Electrical isolation: The reference potential is terminal M1 Level (incl. ripple) High level: 15 V to 30 V Low level: -3 V to 5 V Input delay: for "0" "1": approx. 50 μs for "1" "0": approx. 100 μs As input: Voltage: -3 V to 30 V Typical current consumption: 10 ma at 24 V DC Level (incl. ripple) High level: 15 V to 30 V Low level: -3 V to 5 V Terminal numbers 8, 10, and 11 are "fast inputs" Input delay: for "0" "1": approx. 50 μs / 5 μs for "1" "0": approx. 100 μs/50 μs As output: Voltage: 24 V DC Max. load current per output: 500 ma continuously short-circuit proof output delay: for "0" "1": approx. 400 μs for "1" "0": approx. 100 μs 1) DI: digital input; DI/DO: Bidirectional digital input/output; M: Electronics ground M1: Ground reference NOTICE An open input is interpreted as "low". To enable digital inputs (DI) 0 to 3 to function, terminal M1 must be connected. The following options exist: Connect the reference ground of the digital inputs, or a jumper to terminal M (Notice! This removes electrical isolation for these digital inputs). 34 Operating Instructions, 10/2008, A5E00746546A

Activation of "Safe Torque Off" and "Safe STOP 1" in the standard 3.1 SINAMICS G150 Terminal strip X132 on the CU320 control unit Table 3-3 Terminal strip X132 on the CU320 control unit Terminal Designation 1) Technical data 1 DI 4 2 DI 5 3 DI 6 4 DI 7 5 M2 6 M 7 DI/DO 12 8 DI/DO 13 9 M 10 DI/DO 14 11 DI/DO 15 12 M Max. connectable cross-section: 0.5 mm 2 Type: Spring-loaded terminal Voltage: -3 V to 30 V Typical current consumption: 10 ma at 24 V DC Electrical isolation: reference potential is M2 terminal Level (incl. ripple) High level: 15 V to 30 V Low level: -3 V to 5 V Input delay: for "0" "1": approx. 50 μs for "1" "0": approx. 100 μs As input: Voltage: -3 V to 30 V Typical current consumption: 10 ma at 24 V DC Level (incl. ripple) High level: 15 V to 30 V Low level: -3 V to 5 V Terminal numbers 8, 10, and 11 are "fast inputs" Input delay: for "0" "1": approx. 50 μs / 5 μs for "1" "0": approx. 100 μs/50 μs As output: Voltage: 24 V DC Max. load current per output: 500 ma continuously short-circuit proof output delay: for "0" "1": approx. 400 μs for "1" "0": approx. 100 μs 1) DI: digital input; DI/DO: Bidirectional digital input/output; M: electronics ground M2: Ground reference NOTICE An open input is interpreted as "low". To enable digital inputs (DI) 4 to 7 to function, terminal M2 must be connected. The following options exist: Connect the reference ground of the digital inputs, or a jumper to terminal M (Notice! This removes electrical isolation for these digital inputs). Siemens Controls Operating Instructions, 10/2008, A5E00746546A 35

Activation of "Safe Torque Off" and "Safe STOP 1" in the standard 3.1 SINAMICS G150 Wiring The control lines must be permanently laid. Signal cables and encoder cables should be installed separated from one another. The shields of the control lines must be wide-area grounded directly after entry into the control cabinet. Outside the cabinet unit the cables must be laid in such a way that they are safe to walk on (e.g., conforming to IEC 60204-1). 36 Operating Instructions, 10/2008, A5E00746546A

Activation of "Safe Torque Off" and "Safe STOP 1" in the standard 3.2 SINAMICS S150 3.2 SINAMICS S150 3.2.1 Activation of "Safe Torque Off" and "Safe STOP 1" Description The activation of the safety functions already contained in the standard (i.e., "Safe Torque Off" and "Safe Stop 1") can also be used without option K82. Note Refer to the circuit diagrams enclosed for the interconnections for your device. Note The Safety functions must be activated prior to use via parameter assignment. An acceptance test must be performed and an acceptance log must be created. The following functions (terms and definitions in accordance with IEC 61800-5-2) can be activated: Safe Torque Off (STO) Safe Stop 1 (SS1, time-controlled) Note The integrated safety functions, starting from the (SI) input terminals of the SINAMICS components (Control Unit, Motor Module), satisfy the requirements in accordance with the equipment directive 98/37/EC, the EN 60204-1, DIN EN ISO 13849-1 category 3 (formerly EN954-1) as well as the requirements for Performance Level (PL) d and IEC 61508 SIL2. In addition, most of the safety functions of the SINAMICS have been certified by independent institutes. An up-to-date list of certified components is available on request from your local Siemens office. Recommended application This variant is used when: Activation will be executed optically isolated with a voltage of 24 V DC. Working with control lines which are shorter than 30 m. When devices are used in plants with low spatial elongation (watch out for the drop in voltage at 24 V DC!). Siemens Controls Operating Instructions, 10/2008, A5E00746546A 37

Activation of "Safe Torque Off" and "Safe STOP 1" in the standard 3.2 SINAMICS S150 Functional principle The first shutdown path for the integrated safety functions is activated via a digital input on the control unit; digital inputs DI0 to DI7 are available for this purpose. The second shutdown path for the integrated safety functions is activated via the terminals (- X41:1, -X42:2) on the Control Interface Board of the Motor Module. The selection and deselection must be executed concurrently. The time delay that is unavoidable due to mechanical switch processes, for instance, can be adapted via parameters. The selection of the safety function on the Control Unit and on the Control Interface Board of the Motor Module must be executed over two channels. A switch in accordance with ISO ISO 13850/ EN 418, positive opening in accordance with EC 60947-5-1, or a certified safety controller must be used as activation element. DANGER Responsibility for selecting the correct activation element for the purpose of compliance of the overall system with the required standard (DIN EN ISO 13849-1 (formerly EN-954-1) Cat. 3 PL d or DIN EN 61508 SIL2) rests with the user. Terminal strip X41 on the Control Interface Board of the Motor Module Table 3-4 Terminal strip X41 on the Control Interface Board of the Motor Module Terminal Function Technical data -X41:2 EP +24V (enable pulses) -X41:1 EP M1 (Enable Pulses) Supply voltage: 24 V DC (20.4 V - 28.8 V) Power consumption: 10 ma Signal propagation times: L H 100 µs H L: 1000 µs 38 Operating Instructions, 10/2008, A5E00746546A

Activation of "Safe Torque Off" and "Safe STOP 1" in the standard 3.2 SINAMICS S150 Terminal strip X122 on the CU320 control unit Table 3-5 Terminal strip X122 on the CU320 control unit Terminal Designation 1) Technical data 1 DI 0 2 DI 1 3 DI 2 4 DI 3 5 M1 6 M 7 DI/DO 8 8 DI/DO 9 9 M 10 DI/DO 10 11 DI/DO 11 12 M Max. connectable cross-section: 0.5 mm 2 Type: Spring-loaded terminal Voltage: -3 V to 30 V Typical current consumption: 10 ma at 24 V DC Electrical isolation: The reference potential is terminal M1 Level (incl. ripple) High level: 15 V to 30 V Low level: -3 V to 5 V Input delay: for "0" "1": approx. 50 μs for "1" "0": approx. 100 μs As input: Voltage: -3 V to 30 V Typical current consumption: 10 ma at 24 V DC Level (incl. ripple) High level: 15 V to 30 V Low level: -3 V to 5 V Terminal numbers 8, 10, and 11 are "fast inputs" Input delay: for "0" "1": approx. 50 μs / 5 μs for "1" "0": approx. 100 μs/50 μs As output: Voltage: 24 V DC Max. load current per output: 500 ma continuously short-circuit proof output delay: for "0" "1": approx. 400 μs for "1" "0": approx. 100 μs 1) DI: digital input; DI/DO: Bidirectional digital input/output; M: Electronics ground M1: Ground reference NOTICE An open input is interpreted as "low". To enable digital inputs (DI) 0 to 3 to function, terminal M1 must be connected. The following options exist: Connect the reference ground of the digital inputs, or a jumper to terminal M (Notice! This removes electrical isolation for these digital inputs). Siemens Controls Operating Instructions, 10/2008, A5E00746546A 39