SIL-A. Overcurrent and Earth Fault Relay for Primary and Secondary Distribution. Main characteristics

Similar documents
SIA-B. Overcurrent & Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered / Standard CTs. Main characteristics

Function permission: yes/no. Operating range: 0.10 to 30 xin (step 0.01) Operating time: 0.02 to 300 s (step 0.01 s) Activation level 100%

ISO 9001:2000 SIL A. Overcurrent and Earth fault relay INSTALLATION GUIDE. Guia_SIL-A_Rev / 48

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

SIA/SIL. Secondary and Primary Distribution Protection Relays. Specialized in self powered relays IEC 61850

INSTALLATION & COMMISIONING GUIDE

Protection relay for secondary distribution

SIA B Self and Dual powered Overcurrent & Earth Fault Protection Relay USER S MANUAL L

U lity network. system Q sys. Interconnected P sys. P load Q load. P gen Q gen. Generator network

ISO 9001:2000 SIL A. Overcurrent and Earth-Fault relay USER S MANUAL SER S MANUAL

SIA C. Self-powered overcurrent relay USER MANUAL

INTRODUCTION. The PL-50 MO and PM-250 families represent the. PM-250-H: Horizontal box. PM-250-V: Vertical box

NPW800R RETROFITTING. Power and Volatge Protection Relay

SIL. Protection relays for primary and secondary distribution

Bus Bar Protection Relay B-PRO 4000

SR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.

ADDITIONAL INFORMATION MODBUS INSTRUCTION MANUAL. Request publication Request publication DNP 3.0 INSTRUCTION MANUAL

SEL-487B. A Powerful Solution for Busbar Differential Protection. Bus Differential and Breaker Failure Relay

SIA/SIL. Secondary and Primary Distribution Protection Relays. Specialized in self powered relays IEC 61850

VIP 40/45 VIP 400/410

SYMAP R Plug in Variants FI, MI, 87M, TI Technical data

Index POWER T&D. SIA-B (Dual & Self powered) OC&EF Protection for Secondary Distribution with specific transformers... 20

MiCOM P111. Three phase and earth fault overcurrent relays

Protection Relays PHASE & RESIDUAL OVERCURRENT

INTEGRATED SYSTEMS AND CONTROL, INC. User s Hardware Manual. PCMNET V 7. xx

REL52001 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, 2 x RJ-45

MiCOM P124 T&D. Self and Dual Powered Overcurrent Relays

MiCOM P123R. Overcurrent Relays P123R/EN AD/A11. Upgrade Documentation

Request publication Request publication DNP 3.0 INSTRUCTION MANUAL. Request publication

Remote communication options include IEC Ethernet communications or Modbus (RS485).

REL52002 Easergy P3U30, 4L, 4U, 16DI/8DO, Uaux: V, DI: V, RS-485

GENERAL CATALOGUE. Equipments. Devices. fanox.com

MiCOM P122C Time-Overcurrent Protection

SACE Emax 2 Specification guide

BF

Transformer Protection and Control RET630 Numerical transformer protection in medium voltage networks

EDR-3000 Eaton Distribution Relay

MiCOM P521. Fast feeder differential protection

BF Option. BESTNet BESTNet BESTNet BESTNet BESTNet BE1-700C DIGITAL OVERCURRENT PROTECTIVE RELAY ADVANTAGES

MiCOM P124. Self and Dual Powered Overcurrent Relays. Protection Relays

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Advanced distribution feeder solution with integrated protection, monitoring, and control

Relion 615 series Line Differential Protection and Control RED615 Ver. 2.0 Technical Presentation

TRANSFORMER PROTECTION SYSTEM ADVANTAGES 87N

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Combined Overcurrent and Earth-fault Relay SPAJ 140 C. Product Guide

Section 4 Ground-Fault Protection Devices

EDR-3000 Eaton Distribution Relay

GE Multilin 350 Feeder Protection Relay Specifications

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

Maximize process uptime with the SEL-patented motor thermal model.

Easy To Use OEMS Take Note

MULTIFUNCTION MICROPROCESSOR PROTECTION RELAY TYPE IM30-G DATA BASE

7SR242 Duobias Multi-Function 2-Winding Transformer Protection Relay

SORDS ELECTRIC ~ MA7200. Sensorless Vector AC Inverter.

F650 Firmware Release Notes / History (Rev 10)

IED (Intelligent Electronic Device)

BF 79 81

MiCOM P12x/y. Three phase and earth fault overcurrent relays

Earth-fault Relay SPAJ 110 C. Product Guide

SIPROTEC 7SC80 Feeder Protection and Automation Answers for infrastructure and cities.

Transformer Protection Relay

GE Power Management. UR F60 Feeder Management Relay An integrated feeder protection and metering solution

METERING INSTRUMENTS AND CURRENT TRANSFORMERS

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

CURRENT PROTECTION RELAY SMPR-1

TWO-WINDING TRANSFORMER DIFFERENTIAL

BF 86 FEEDER PROTECTION SYSTEM ADVANTAGES

GRE130. Protection and Control for MV Systems

FP-5000 Series Multi-functional Microprocessor-based Feeder Protective Relay

RT4F-110V/25A RECTIFIER

Metering Devices, Protective Relays, Software and Connectivity. Pre-Wired Control Power, Voltage and CT Inputs

Sensitive definite time or inverse time earth-fault stage for back-up residual earthfault

Relion 615 series Transformer Protection and Control RET615 Ver. 2.0 Technical Presentation

Combined Overcurrent and Earth-fault Relay SPAJ 141 C. Product Guide

Recloser Controller for feeder protection and automation siemens.com/distribution-automation

Feeder Protection Relay REF 610. Product Guide

FP-5000 Feeder Protection

Numerical motor protection in medium voltage networks Motor Protection and Control REM620

DIGITAL RELAY OF PROTECTION AND AUTOMATION SERIES PC83 AND PC830

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

MIN II. Complete numerical ground directional protection. Digital Energy Multilin. Protection and Control. Monitoring and Metering.

PM800 series. Applications

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

Type SDR reclosers plus controllers and type B-2 recloser bypass switch assembly usa.siemens.com/mediumvoltage

ATV12H075M3 variable speed drive ATV kW - 1hp V - 3ph - with heat sink

Products Portfolio. Pole mounted Vacuum Recloser

PROTECT Electronics Co. Ltd

Three phase and earth fault overcurrent relays

Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Version 3.3

Residual overvoltage relay

DNP3 Communications Protocol

www. ElectricalPartManuals. com Protective Relays PROTECTION AND CONTROL FUNCTIONS ADVANCED CAPABILITIES

Relion 615 series. Feeder protection and control REF615 ANSI Product guide

7SR11 and 7SR12 Settings and Instruments

Modbus Server SIEMENS Algorex (printer port)

RELAYABLE POWER. AQ 200 series protection, control, measurement and monitoring IEDs

Bus Differential and Breaker Failure Relay. Advanced bus protection with built-in breaker failure detection

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

Transcription:

SIL-A Overcurrent and Earth Fault Relay for Primary and Secondary Distribution Main characteristics The SIL-A is an overcurrent and earth fault protection relay for primary and secondary distribution with power supply 24-22 Vdc/ 4-23 Vac. The current measurement is obtained either by standard Many protection functions: (Zone Selection Interlocking) To allow the relays have a communication port on the front of the equipment and

5 Oscillographic records, 2 fault reports and 2 events saved in non-volatile RAM memory with date/time, even without power supply, thanks to its internal RT (Real Time lock). Additional information to fault reports Technical specifications SIL-A Functions diagram SIL-A 52 5_1 5_2* 5/51 49* SHB* Hmi LD 2x2 7 keys+i/52+b79 RT (1 ms) LP 5BF* TB* 46 DFR 5 N/G_1 (1) 5 N/G_2* (1) 5/51 N/G Setting groups LDP 37* 74T* 46B* * optional 79 49T* 52 6* 74TS* 6* PG Test Out configurable Input configurable * available through programmable logic control (PG) tº IE 617-5-14* Modbus TP/IP* DNP3. TP/IP* IE 615* ModBus RTU* IE 617-5-13* ModBus RTU* DNP3. Serial* Leds configurable ModBus RTU. Tx, Rx Ethernet RS45 RS45 RS232 SIom Modem (1) Note:

5_1 5_2 5N/G_1(1) 5N/G_2(1) 5/51 5/51N/G(1) Technical specifications Technical parameters SIL-A urrent Tap:.1 to 3 xin (step.1) Time Delay: Adaptation B :.2 to 3 s (step.1 s) Adaptation :. to 3 s (step.1 s) Activation level 1% Deactivation level 95% Timing accuracy (greater of both): urrent Tap: Adaptation B :.1 to 3 xin (step.1) Adaptation :.5 to 3 xin (step.1) Time Delay: Adaptation B :.2 to 3 s (step.1 s) Adaptation :. to 3 s (step.1 s) Activation level 1% Deactivation level 95% Timing accuracy (greater of both): urrent Tap:.1 to 7 xin (step.1) urves IE 6255-151 and IEEE urve type: IE Inverse curve, IE very inverse curve, IE extremely inverse curve, IE long time inverse, IEEE Inverse curve, IEEE very inverse curve, IEEE extremely inverse curve, Defined time. Time delay: Adaptation B :.2 to 3 s (step.1) Adaptation :. to 3 s (step.1) Time Dial (TMS):.2 to 2.2 (step.1) urve, activation level 11% urve, deactivation level 1% Defined time, activation level 1% Defined time, deactivation level 95% Timing accuracy for IE and IEEE curves selection: ±3 ms or ±5% (greater of both). Timing accuracy for DT curve selection (greater of both): urrent Tap: Adaptation B :.1 to 7 xin (step.1) Adaptation :.5 to 7 xin (step.1) urves IE 6255-151 and IEEE urve type: IE Inverse curve, IE very inverse curve, IE extremely inverse curve, IE long time inverse, IEEE Inverse curve, IEEE very inverse curve, IEEE extremely inverse curve, Defined time. Time delay: Adaptation B :.2 to 3 s (step.1) Adaptation :. to 3 s (step.1) Time Dial (TMS):.2 to 2.2 (step.1) urve, activation level 11% urve, deactivation level 1% Defined time, activation level 1% Defined time, deactivation level 95% Timing accuracy for IE and IEEE curves selection: ±3 ms or ±5% (greater of both). Timing accuracy for DT curve selection (greater of both): 46 ircuit Breaker Monitoring 5BF(*) 79 74TS LP (1) Note: and 5/51N. are 5N/G(2) and 5/51N/G. (*) Note: urrent Tap:.1 to 7 xin (step.1) urves IE 6255-151 and IEEE urve type: IE Inverse curve, IE very inverse curve, IE extremely inverse curve IE, long time inverse, IEEE Inverse curve, IEEE very inverse curve, IEEE extremely inverse curve, Defined time. Time delay: Adaptation B :.2 to 3 s (step.1) Adaptation :. to 3 s (step.1) Time Dial (TMS):.2 to 2.2 (step.1) urve, activation level 11% urve, deactivation level 1% Defined time, activation level 1% Defined time, deactivation level 95% Timing accuracy for IE and IEEE curves selection: ±3 ms or ±5% (greater of both). Timing accuracy for DT curve selection (greater of both): Maximum number of openings: 1 to 1. (step 1) Maximum accumulated amps: to 1. (M(A²)) (step 1) Opening time:.2 to 3 s (step.1 s) losing time:.2 to 3 s (step.1 s) Excessive repeated openings: 1 to 1. (step 1) Repetitive openings/time: 1 to 3 min (step 1 min) Open circuit breaker activation threshold: % In Open circuit breaker reset threshold: 1% In Yes/No Time delay:.2 to 1. s (step.1 s) Open circuit breaker activation threshold: % In Open circuit breaker reset threshold: 1% In onfigurable function pickup Yes/No Hold enable: Yes/No/No time Number of reclosings: 1 to 5 Reclosing time 1, 2, 3, 4, 5 :.2 to 3 s (step.1 s) Hold time:.2 to 3 s (step.1 s) Reset time:,2 to 3 s (step,1 s) Safe time:.2 to 3 s (step.1 s) Locking possibilities: pulse inputs, level inputs, commands. Yes/No Time delay:.2 to 3 s (step.1 s) ontinuity in circuits A and B Inputs Adaptation B : onfigurable Digital Inputs Adaptation : Dedicated Digital Inputs Yes/No Settings groups: 1 to 4 (step 1) No load Time:.2 to 3 s (step.1 s) old load Time:.2 to 3 s (step.1 s) LP activation threshold: % In LP reset threshold: 1% In

Technical parameters SIL-A PG 6 49T OR4, OR4_LATH, OR4_PULSES, OR4_TIMERUP, OR4_ PULSE, NOR4, NOR4_LATH, NOR4_TIMERUP, NOR4_ PULSE, AND4, AND4_PULSES, AND4_TIMERUP, AND4_ PULSE, NAND4, NAND4_TIMERUP, NAND4_PULSE Allows to latch (lock out) the contact trip due to programmable logic (PG: LATH). Available through configurable inputs thanks to the programmable logic Yes/No urrent Tap:.1 to 2.4 xin (step.1) heating: 3 to 6 min (step 1 min) Load Data Profiling (LDP) Demand of current with the following characteristics: Sampling rate (interval): configurable through communications (1 6 min) Date/Time IMAX (in interval) IMAX (actual) IA IB I IN cooling: 1 to 6 heating (step 1) Same voltage as the auxiliary power supply 49(*) Alarm: 2 to 99 % (step 1%) Trip level: 1% Deactivation level: 95% of alarm level inputs 25 Vac A 3 Vdc 5 A Trip time accuracy: ± 5% over the theoretical value Outputs 4 configurable outputs Trip time curves are valid under 2 times the adjusted tap. With currents higher than 2 times the adjusted tap, trip time and thermal image value are truncated to 2 times the adjusted tap. Frequency 5/6 Hz selectable by general settings 74T(*) 37(*) 46B(*) SHB(*) TB(*) 6 Settings groups RT Events Disturbance Fault Recording (DFR) (1) Note: and 5/51N. Yes/No Time delay:.2 to 3 s (step.1 s) Timing accuracy: ±3 ms or ±.5% (greater of both) Function enable : Yes/No urrent Tap:.1 to 3 xin (step.1) Time delay:.2 to 3 s (step.1 s) Activation level: 1% Deactivation level: 15% Instantaneous reset Timing accuracy: ±3 ms or ±.5% (greater of both) Yes/No urrent Tap: 15 to 1% (step 1%) Time delay:. to 3 s (step.1 s) Timing accuracy (greater of both): If Time Delay, to,2 s, ±5 ms or ±.5% If Time Delay,2 to 3 s, ±3 ms or ±.5% Yes/No urrent Tap: 5 to 5% (step 1%) Reset time:. to 3 s (step.1 s) Block threshold:.1 to 3 x In (step.1) Yes/No urrent Tap: 1.5 to 2 x In (step.1) Available through configurable inputs and outputs thanks to programmable logic 4 settings groups Activated by inputs or by general settings. apacitor charge time: 1 minutes Operation with no auxiliary voltage: 72 hours 2 events 16 samples/cycle Fault start configurable 2 fault reports with 24 events each one 5 OMTRADE rec. (1 cycles): 3 pre. + 97 postfault cycles OMTRADE IEEE 37.111-1991 4 analog channels and 4/35 digital channels (adapt. B/ ) urrent measurement ommunications Phase current (IA, IB, I), neutral (IN), positive sequence (I1), negative sequence(i2), maximum current (Imax) and thermal image (TI) Phase current (IA, IB, I), neutral (IN), positive sequence (I1), negative sequence(i2), phase second harmonic current (IA-2H, IB-2H and I-2H), maximum current (Imax) and thermal image (TI) Fundamental values (DFT) Sampling: 16 samples/cycle ±2% Accuracy over a band of ±2% over the nominal current and 4% over the rest of the range ±2% Accuracy over a band of ±2% over the nominal current and 4% or ±5 ma (greater of both) over the rest of the range Saturation limit: 3 times rated current LOAL OMMUNIATION 1 Local port RS232: ModBus RTU REMOTE OMMUNIATION (*) 1 remote port with the following options : 1 Remote port RS45: ModBus RTU, IE 67-5-13 or DNP3. Serial (by model/settings) 1 Remote port RJ45: IE 615, DNP3. TP/IP, Modbus TP/IP or IE 67-5-14 (by model/ settings) Auxiliary power 24-23 Vac/dc (-2% / +1%) Operating temperature : -1 to 7º Environmental Storage temperature: -2 to º conditions Relative humidity: 95% Measurement 3 or 4 T /1 or /5 Transformers Measurement 3 LPT (current transformers with voltage output) Metallic box Panel mounted. Mechanical Height x Width: 177 x 17 mm haracteristics Depth: 122.1 mm IP-54 on pannel Weight: 1,5 kg. are 5N/G(2) and 5/51N/G. (*) Note:

Technical specifications onnections diagram SIL-A 3 LPT Transformers 3 Standard urrent Transformers SILA Overcurrent & Earth Fault relay SILA Overcurrent & Earth Fault relay LPT 4 Standard urrent Transformers SILA Overcurrent & Earth Fault relay

onnections diagram SIL-A 1.5 17 17 1 7 1.5 1.5 7 1. 5 15 17.5 7 17.5 4 1 161 177 161 151 177 UTOUT 161 153 122.1 12.3 16 4 1 5 7 1 5 Selection & Ordering data SIL-A SIL-A X S Overcurrent & Earth Fault Protection Relay for Primary & Secondary X S 2 4 A B D 7 1 2 A B E PROTETION FUNTIONS 5_1 +5_2 + 5/51 + 5N/G_1 + 5N/G_2 + 5/51N/G + 52 + 5BF + 46 + 79 + 74TS + LP + 6 + 49T PHASE MEASUREMENT LPT (Primary = 5 A) Standard: 1 A or 5 A Sensitive:.5 A or 2.5 A NEUTRAL MEASUREMENT LPT (Neutral internally calculated) Standard: 1 A (.1-3 A) or 5 A (.5-15 A) Sensitive:.1 A (.1-3 A) or.5 A (.5-15 A) NET FREQUENY Defined by General Setting POWER SUPPLY 24-23 Vac/dc ADDITIONAL FUNTIONS - + 49 + 74T + 37 + 46B + Trip Block + 49 + 46B + SHB (available only for Adaptation ) REAR OMMUNIATIONS RS232 (Modbus RTU) + RS45 (Modbus RTU or IE 67-5-13) RS232 (Modbus RTU) + RJ45 (IE 615) RS232 (Modbus RTU) + RJ45 (IE 67-5-14) RS232 (Modbus RTU) + RS45 (Modbus RTU or DNP3. serial) RS232 (Modbus RTU) + RJ45 (Modbus TP/IP or DNP3. TP/IP) INPUTS-OUTPUTS 6 Inputs + 4 Outputs MEHANIS Vertical assembly LANGUAGE English, Spanish and German English, Spanish and Turkish English, Spanish and French English, Turkish and Russian ADAPTATION B - Without 5_2, 5N/G_2 and 5BF (74TS with dedicated DI) Example of ordering code: SIL A 2 A 1 2 B B SILA 2 A 1 2 B B