MODEL: WL40EW2F. Wireless I/O WL40F Series

Similar documents
MODEL: GR8-EM. Communication Adaptor GR8 Series

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: DL8. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Web Data Logger DL8

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: 43AL1. Digital Panel Meters 43 Series

MODEL: 47LYV. Digital Panel Meters 47 Series

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

MODEL: R2K-1 SEN TRONIC AG. R2K Series

User Manual Edition: v a

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

MODEL: 40DN. Digital Panel Meters 40 Series

R3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)

Web-enabled DAQ System

RAD XD and RAD XD-WM a/b/g Transceiver with Serial Link Quick Start Guide

Du line. Dupline Field- and Installationbus Dupline Ethernet Modbus/TCP Gateway Type G G Type Selection

General Specifications

Wireless Solutions. 5.1 Wireless LAN & Wireless Modem. Wireless Modems. Intelligent GPRS/GSM Modules. Mini-Programmable Automation Controllers

R6-NE1 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP, for 32-point analog signals)

PWR. Power Module Slots

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

NPort Z2150/Z3150 Series

IPM-01 / IPM-01H MODBUS TCP/RTU Bridge User Guide

MODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series

Multiple Solutions in One Device

RS232C/RS485 Data can be easily monitored by LAN

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

OnCell G3150A-LTE Series

WIRELESS GATEWAY DUOS

Managed 100 Mbps Ethernet Switches TOP FRONT. Click 340/341/342

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

LM300 Bluetooth Ethernet Access Point/Server 3 Simultaneous Bluetooth SPP Connections

Industrial 1-Port 10/100/1000T Ultra PoE + 1-Port Coax/UTP Long Reach PoE Kit (LRP-201ET + LRP-201HT)

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

IntesisBox Modbus Server Panasonic

Wireless Transducer MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:

IP67 Certified 2T2R 5GHz Outdoor Wireless-N Access Point - PoE-Powered 300Mbps a/n WiFi AP

Part Number Total I/O Power Voltage Input Voltage Output Type Maximum Digital I/O Maximum Analog I/O V AC Relay 24V DC.

IAP-320 series are reliable a/b/g WLAN Access Point with 2 ports LAN. It supports 802.1X and MAC filters for

Industrial IEEE a/b/g/n wireless access point with 2x10/100/1000Base-T(X) Features

The TRSUN is the complete solution for the remote monitoring of photovoltaic plants.

WiFi 16 Relay Board TCP ModBus Controlled - User Manual 21 Aug WiFi 16 Relay Board TCP ModBus Controlled

MODEL: 43DV2. Digital Panel Meters 43 Series

tsh-700 Series User Manual

D5 SERIES WIRELESS SYSTEM

Energy Management Energy Transducer Type ET112

RAD-WHG/WLAN-XD. WirelessHART gateway with integrated WLAN (802.11b/g) INTERFACE Data Sheet 2720_en_C. 2 Features. 1 Description

Industrial IEEE b/g/n wireless access point with 2x10/100Base-T(X) Features

Industrial Serial Device Server

ECAN-240. (Modbus TCP to 2-port CAN Bus Gateway User manual) ECAN-240 Modbus TCP to 2-port CAN Bus Gateway User Manual, Version 1.0.

Arm-based wireless-enabled DIN-rail industrial computers with 2 serial ports and 2 LAN ports. Features and Benefits.

Intelligent 4 Port RS-422/485 to 2 Port Ethernet Serial Device Server with PoE

LM300 Bluetooth Ethernet Access Point/ Server 3 simultaneous Bluetooth SPP connections

DATA SHEET LAN Server For Energy and Power meters AEM and APM with Modbus interface

Wireless networking with three times the speed and five times the flexibility.

Industrial 1-port RS422/485 Modbus Gateway IMG-110T

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

MOBITEK C60T M2M Wireless Gateway

Industrial Media Converters

Embedded Modbus TCP Module GS11-MT. User Manual REV 1.1. SST Automation.

Bridge: The 702-W will operate in Layer 2 without network segmentation. Router: The 702-W offers Layer 3 routing to allow network segmentation.

adaptiverf IMPL-10 Wireless IP Bridge User Guide expertise in wireless design June adaptiverf Ltd Preliminary DS-IPML-10-1V0 Page 1

MIC-2 MKII, Multi-instrument DATA SHEET

Supplementary Components WirelessHART products

T1K MODBUS Base Controller Specifications

GW1101 Rev Introduction. DASH7 - IP Gateway for Industrial Applications. Applications. Description. 868MHz / 915MHz.

Outdoor 300 Mbps 2T2R Wireless-N Access Point - 5GHz a/n PoE-Powered WiFi AP

Rugged Outdoor Wireless-N Access Point - 2.4GHz - PoE Powered - Metal IP67

M-bus web server. Meters and Energy Cost Allocation WTV676-HB6035

Industrial 1-Port 10/100/1000T Ultra PoE + 1-Port Coax/UTP Long Reach PoE Extender (-20~70 degrees C)

IP67 Certified 2T2R 2.4GHz Outdoor Wireless-N Access Point - PoE-Powered 300 Mbps b/g/n WiFi AP

MODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)

Features. :. Introduction. :. Leader 5000 Appearance. Ethernet-Based Block I/O System

Industrial 2-port RS422/485 Modbus Gateway

IntesisBox Modbus Server - Honeywell XLS 80

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

LightRules Network Infrastructure

MODEL: 40DV SEN TRONIC AG. Digital Panel Meters 40 Series

Interface WI-FI CODE: INTW. v.1.0. Edition: 2 from Supersedes the: 1 from edition

EGW1-IA3-MB User s Manual

isma-b-mg-ip User Manual Global Control 5 Sp. z o.o. Poland, Warsaw

WF-2000 Series Wi-Fi I/O Module

BLE WiFi Gateway. Model: G1. Version: V Contents. Contents Overview... 2

CONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4

WEB-ENABLED REMOTE TERMINAL UNIT Model: DL8 USERS MANUAL

Transcription:

Wireless I/O WL40F Series WIRELESS GATEWAY Modbus/TCP (Ethernet), Modbus-RTU Transparent 900MHz Band Wireless Device (parent device) 60 (2.36) FUTIONS & FEATURES This unit Incorporates 900MHz band wireless module with RS-485 transparent type, which can communicate using Modbus- RTU protocol. Converts Modbus-RTU (RS-485) and Modbus/TCP (Ethernet) protocol. Incorporates the module compliant with FCC Part 15, and can be used only in the United States. [260 (10.24)] 155 (6.10) mm (inch) -[1][2] ORDERING INFORMATION Code number: WL40EW2F-[1][2] Specify a code from below for each [1] and [2]. (e.g. WL40EW2F-R/E/Q) Specify the specification for option code /Q (e.g. /C01) [1] POWER INPUT DC Power S: 12 V DC (Operational voltage range 12 V ±10 %, ripple 10 %p-p max.) R: 24 V DC (Operational voltage range 24 V ±10 %, ripple 10 %p-p max.) [2] OPTIONS (multiple selections) Antenna /S: Sleeve antenna /E: Rooftop antenna Other Options blank: none /Q: Option other than the above (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating RELATED PRODUCTS For related products of wireless device, refer to M-System's web site. Maintenance software Maintenance console: MH920 Console International (model: MH920CI) (OKI) (Maintenance software is downloadable at M-System s web site.) Coaxial cable 7.5 m extension cable for rooftop antenna (model: CX- SAC0SAD0Q0750) (OKI) Using 7.5 m coaxial cable for extension decreases transmission distance. GENERAL SPECIFICATIONS Connection Wireless network: SMA coaxial connector Power supply: Tension clamp (Front Twinconnection) Applicable wire size: 0.2-2.5 mm 2, stripped length: 10 mm Ethernet: RJ-45 Modular Jack Maintenance: Mini USB type B female connector Housing material: Flame-resistant resin Isolation: Power supply to Ethernet to to antenna connector Switch: IP Reset Refer to the instruction manual for details. Indicator LED: Power COMMUNICATION Common spec. Modbus protocol Protocol: Modbus/TCP Data: RTU (Binary) Port No.: 502 Max. number of socket connections: 8 IP address: 192.168.0.1 (factory setting); Selectable with web browser Ethernet Communication Standard: IEEE 802.3u Transmission: 10BASE-T, 100BASE-TX Baud rate: 10/100 Mbps (Auto Negotiation function) WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 1/7

Transmission media: 10BASE-T (STP, Category 5) 100BASE- TX (STP, Category 5e) Max. length of fieldbus segment: 100 meters Ethernet indicator LED: Link, Link100 STANDARDS & APPROVALS Module conforming to FCC Part 15 incorporated WIRELESS SPECIFICATIONS Communication Standard: IEEE 802.15.4g Frequency: 900MHz band (902-928 MHz) Max. Transmission power: 20mW Bandwidth: 400 khz Modulation: GFSK Baud rate: Max. 100 kbps Channels: 1 to 43ch Security: 128bit AES Indicator LEDs: 920Run, 920Link Number of child devices: Max. 100 Protocol: Modbus-RTU Communication module: Coordinator module incorporated (Oki Electric Industry Co., Ltd. ) Radio parameters setting: by Web browser Max. transmission distance (optical): Approx. 1 km Antenna Sleeve antenna (Model: MH920-ANT-F (S)) Indoor use Non-waterproof Non-directional Gain: 3.0dBi max. Rooftop antenna (Model: MH920-ANT-F (R)) Outdoor/indoor use Cable length: 2.5 m Waterproof performance: IPx6 (except connector) Non-directional Gain: 2.0dBi max. INSTALLATION Current consumption: 24 V DC: 90 ma 12 V DC: 170 ma Operating temperature: -20 to +60 C (-4 to +140 F) Operating humidity: 10 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: DIN rail Weight Unit: Approx. 270 g (0.60 lb) Sleeve antenna (standard): 27 g (0.95 oz) Rooftop antenna: 52 g (1.83 oz) PERFORMAE Insulation resistance: 100 MΩ with 500 V DC Dielectric strength: 1500 V AC @ 1 minute (power input to Ethernet or to antenna connector) WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 2/7

WEB BROWSER SETTING With Web browser, settings shown below are available. Refer to the operating manual (EM-9080-B) for detailed settings. TCP / IP SETTING ITEM SETTING RANGE DEFAULT IP address 1.0.0.0 223.255.255.255 192.168.0.1 Subnet mask 224.0.0.0 255.255.255.255 255.255.255.0 Default gateway 0.0.0.0 255.255.255.255 0.0.0.0 MODBUS / TCP SETTING ITEM SETTING RANGE DEFAULT Port 1 65535 502 Modbus exception response Not return 06 (BUSY), 0B (ERROR) / Return 06 (BUSY), 0B (ERROR) Communication timeout 1 60 (min.) 1 (min.) WIRELESS SETTING ITEM SETTING RANGE DEFAULT PAN ID (group number) 0000 FFFE (hexadecimal, 4 digits) 0000 Radio channel number 1 43ch 1ch Network name Encryption key English one-byte characters within 16 characters (one-byte space, -, _,., @ are usable.) 0000...0 FFFF...F (hexadecimal, 32 digits) Return 06 (BUSY), 0B (ERROR) MH920 0000...0 Prefi x 2000:0000:0000:0000 3FFF:FFFF:FFFF:FFFF 2000:0000:0000:0000 Transmitter power output 0.16mW / 1mW / 20mW 20mW Device type in a network, Number of devices in a network Child (fi xed), 1 to 30 devices / Child (fi xed), 31 to 60 devices / Child (fi xed), 61 to 100 devices / Child (fi xed) + child (moving) Set network quality Standard (recommended) / Frequency of route switching and delay (higher) / Frequency of route switching and delay (highest) Child (fi xed), 1 to 30 devices Standard (recommended) Network join mode V3-compatible mode / Fast join mode V3-compatible mode Packet fi ltering None / Yes (polling type) Yes (polling type) Filter timeout on polling 1.0 60.0 (sec.) 4.0 (sec.) Setting mode of short address Range mode: 1 device (max. multi drop number) Range mode: 1 to 4 devices (max. multi drop number) Range mode: 1 to 8 devices (max. multi drop number) Range mode: 1 to 16 devices (max. multi drop number) Range mode: 1 to 31 devices (max. multi drop number) List mode List mode 920Run timeout 0.0 3200.0 (sec.) 5.0 (sec.) Retry times before route switching Once / Twice / Three times Three times Short address list setting Short address MAC address list setting MAC address Connection refusal list setting MAC address * For version confirmation of communication module, refer to the operating manual (EM-9080-B). WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 3/7

EXTERNAL VIEW FRONT VIEW Status Indicator LED Antenna Connector Power 920Link 920Run Link Link100 Network Status Indicator LED Maintenance Connector CFG Ethernet 24V RJ-45 Modular jack Connector for Power Input * IP Reset Reset Switch * Power input defers depending on the power input code you select. TERMINAL ASSIGNMENTS CONNECTORS FOR POWER INPUT Unit side connector: MSTBV2,5/5-GF-5,08AU (Phoenix Contact) Cable side connector: TFKC2,5/5-STF-5,08AU (Phoenix Contact) Power input code: R (24 V DC) 24V ID FUTION Power input code: S (12 V DC) 24V Power input 24 V 12V 12V Power input 12 V Power input 0 V Power input 0 V Not used Not used ID FUTION Not used Not used Power input earth Power input earth WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 4/7

MODBUS FUTION CODES & SUPPORTED CODES Modbus function codes are shown below. DATA AND CONTROL FUTIONS CODE NAME 01 Read Coil Status Digital output from the slave (read/write) 02 Read Input Status Status of digital inputs to the slave (read only) 03 Read Holding Registers General purpose register within the slave (read/write) 04 Read Input Registers Collected data from the fi eld by the slave (read only) 05 Force Single Coil Digital output from the slave (read/write) 06 Preset Single Registers General purpose register within the slave (read/write) 15 Force Multiple Coils Digital output from the slave (read/write) 16 Preset Multiple Registers General purpose register within the slave (read/write) EXCEPTION CODES CODE NAME 06 Slave Device Busy Device s Modbus/TCP request queue is full. 11 Gateway Target Device Failed To Respond Response from 900MHz band wireless device (child) is error, or response timeout occurred. Note: When 900 MHz band wireless device (child) returns an exception code other than the above, the exception code is directly transmitted to upper devices. WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 5/7

EXTERNAL DIMENSIONS unit: mm (inch) With sleeve antenna [R165 (6.50)] 5 (.20) 105 (4.13) [260 (10.24)] 60 (2.36) 45 (1.77) 107 (4.21) [200 (7.87)] 3 (.12) ø3 (.12) ø1.2 (.05) 80 (3.15) 36 (1.42) [155 (6.10)] DIN RAIL 35mm wide With rooftop antenna ø27 (1.06) 8 (.31) Hex. approx. 2500 (98.4) DIN RAIL 35mm wide 20 (.79) 107 (4.21) 3 (.12) WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 6/7

SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Antenna Connector Two-way wireless circuit LED Communication Circuit Isolation RJ-45 Modular Jack To Other Ethernet Devices Maintenance Connector USB Connector 24V* Power Input Control Circuit Reset Switch * Power input defers depending on the power input code you select. SYSTEM CONFIGURATION EXAMPLES PC side as Modbus/Master communicates with child devices via wireless module using Modbus/TCP and RTU protocol, and also communicates with slave devices in multi drop connection (RS-485). LAN cable (STP cable) RS-485 PC Modbus/Master Wireless gateway (model: WL40EW2F) Wireless gateway (model: WL40MW1F) Slave Device Slave Device Slave Device MAX. 31 Specifications are subject to change without notice. WL40EW2F SPECIFICATIONS ES-9080 Rev.0 Page 7/7