V2.5 Supplemental Manual

Similar documents
V3.1 Supplementary Manual

Specification additions/changes for Yamaha CL5/CL3/CL1 V1.02

R Remote Version 4.5 User s Guide

MTX Editor User s Manual

Version 4 Software. Version 4 - Supplement. Issue A, August 2007 for Version 4.0+ Software. D5 V4 Supp 1-1

M-480 RCS. User s Guide

01V96 Editor. Owner s Manual. Special Notices. Contents. Yamaha Pro Audio Global Site

Version 2.0 Manual Supplement

Roland Boutique JP-08 FAQ

Perfecting the Art of Live Sound

Bose ControlSpace Designer Software. User Guide

Previous LS9 Firmware version information

M7CL V3.5 Supplementary Manual

LiveProfessor 2. User Manual. Rev audiostrom.com

DIGITAL AUDIO PROCESSOR

Studio Manager. for. Owner s Manual

Overview. Features. Technical Data Sheet 1 / 6. Digital Mixing Console TF1

V1.1 Supplementary Manual

Overview. Features. Technical Data Sheet 1 / 6. Digital Mixer TF-RACK

VirtualDJ 8 Hercules Universal DJ 1

CL series Live Recording with Nuendo Live. Using Steinberg Nuendo Live

NUAGE MASTER Ncs500-CT

Connecting the SI-24 to the VS-2400CD for Expanded Operation

SD Operation Manual. Appendix 2: Version 3 (April 2014) Theatre Software Operation

2003 Yamaha Corporation. All rights reserved.

MRX Designer User Guide

and close the various Traktor Panels. Setup: click on the setup icon to open the setup dialog. Close: clicking this icon will close TRAKTOR DJ Studio.

VirtualDJ 8 Numark Mixtrack II 1

What s New in VENUE D-Show Software

VirtualDJ 8 Pioneer DDJ-SB 1

Shure wireless system with Yamaha CL/QL consoles. 3 rd Edition: May 2017

VirtualDJ 8 Rane Sixty-Two 1

VirtualDJ 8 Rane Sixty-Four 1

VirtualDJ 8 Pioneer DDJ-SR 1

Firmware Version 1.60 User s Guide

User Manual. Drum Machine

Overview. Features. Technical Data Sheet 1 / 7. Digital Mixing Console QL1

RCS User s Guide. Ver.1.20

SOFTWARE INSTRUCTIONS DIGITAL SPEAKER PROCESSOR DP-SP3

Show Designer 1. Software Revision 3.11

Waves. MultiRack SoundGrid V9. Outboard Processing Host for Your DiGiCo Console

Digitakt OS 1.06 Release Information

QUICKSTART MANUAL ENGLISH ( 3 10 ) MANUALE DE INICIO RÁPIDO ESPAÑOL ( ) GUIDE D'UTILISATION SIMPLIFIÉ FRANÇAIS ( )

DJ Controller DDJ-1000

VirtualDJ 8 American Audio 19MXR 1

VirtualDJ 8 Pioneer DDJ-SB2 1

CobraNet TM Manager Lite for Yamaha Version 1.1 Owner s Manual

Software Revision 1.13

HDx TDM Record/Playback Option Guide

WAVES. MultiRack SETUP GUIDE V9.80

TRAKTOR DJ Studio 2 Quick Reference. Welcome... The TRAKTOR Panels

JLCooper MCS-3000 Series MCS-Panner Operation Notes

Wireless DCP. Owner s Manual. Introduction

KX Editor Owner s Manual

User Guide. English. Manual Version 1.0

QUICK-START GUIDE RELOOP MIXON4

Overview. Features. Technical Data Sheet 1 / 5. Signal Processor MRX7-D

VirtualDJ 8 American Audio 10MXR 1

Digitakt OS 1.07 Release Information

User Guide FFFA

QUICK-START GUIDE ROLAND DJ-808

User Manual. for ArcTrax UWP version

Operation Manual. You must read the Usage and Safety Precautions before use ZOOM CORPORATION

DDJ-SX3. DJ Controller. Operating Instructions

Yamaha DM1000/Nuendo Setup and Control

TORAIZ SP-16 TSP-16. Professional Sampler. Operating Instructions

CL/QL series with Aviom Personal Mixing System. 1st Edition: July 2014

Using CobraNet networking with Bose ControlSpace and PowerMatch products.

Using BOSS TONE STUDIO for ME-25

M2DIS. User Manual.

VS-2480 Q&A BASIC FUNCTIONS. Q: What are the main differences between VS-2480 and VS-1880/1680? Q: Are the audio data compressed?

Introduction (page 6) This explains information on preparing and installing rekordbox, getting started, and using rekordbox.

FW Release Notes Version TEAC Professional Division. FireWire Audio MIDI Interface / DAW Control Surface

dlive Shure Integration Guide

SD9 Update Voice Improved the synchronization of the Live Audio Drums when using the HARMONY or DOUBLE features with the lead voice.

TH100A User Manual 1 Updated April 30, 2018

Multi Amplifier Remote Control (MARC) Software QUICK START GUIDE 1.0.0

ilive and T Series RELEASE NOTES Version 1.54 Iss.1 CD 24/11/09 V1.54 is a maintenance release of the ilive and T Series system firmware.

Overview. Features. Technical Data Sheet 1 / 7. Digital Mixing Console CL1

MOX6/MOX8 Editor VST Owner s Manual

Production Switcher System

QUICKSTART GUIDE ENGLISH ( 3 12 ) INICIO RÁPIDO ESPAÑOL ( ) UTILISATION SIMPLIFIÉ FRANÇAIS ( ) KURZANLEITUNG DEUTSCH ( )

AEQ CAPITOL SCREEN USER S MANUAL ED. 04/18 Firmware Version: PBA Base CPU v1.73 or higher Software Version: AEQ CAPITOL SCREEN v1.

Axiom DirectLink for Cubase User Guide

Inear Display AMALGAME

WAVES. MultiRack SETUP GUIDE V9.7

MDW Hi-Res Parametric EQ Plug-In Guide

PM1D Manager V2 for Windows

VirtualDJ 8 American Audio VMS4 1

Organ, Initial Touch. Hard1, Hard2, Medium, Soft1, Soft2. AWM Stereo Sampling

User Guide FFFA

MOTIF XS Editor VST Owner s Manual

x0xb0x Bassline Synthesizer ( Sokkos OS ) User Manual

Bitbox User s Manual

Supplementary Manual

Contents. Version 1.5 and later. Introduction Panel Descriptions Sending Still Images to the VR-4HD... 12

VirtualDJ 8 Rane TTM57 MKII 1

Digitakt OS 1.10 Release Information

The Matrix Mixer. Yamaha 01X and Yamaha 01V96 Digital Audio Mixing Desks. User Manual

DM-3200 SONAR. DM-3200 DAW Control. Mackie Control emulation for SONAR 4.x. Version 1.11 DM-3200 SONAR 1/8

Transcription:

V2.5 Supplemental Manual EN

Contents Theatre mode...3 Improved labeling of the USER DEFINED keys and USER DEFINED knobs...7 Dante Domain Manager (DDM)...8 Improved screen encoder operation...10 Improved channel name display...10 Improved HY SLOT4 feature...10 Addition input patch setting...10 Expanded MIDI transmission/reception on/off function...11 Additional option in the GAINS SHOWN ON OVERVIEW SCREEN section...12 Additional library function...13 2 RIVAGE PM series V2.5 Supplemental Manual

Theatre mode Theatre mode 3. Press the UNIT MODE tab. This mode is suitable for use in theatres. It enables you to store EQ and dynamics settings in four banks and assign one of those banks to each actor on stage. In Theatre mode, EQ or dynamics parameter settings are not stored in each scene. Only information regarding which bank is used will be stored. Therefore, fine adjustments made while using Theatre mode will be applied to the appropriate settings in scenes that use the same bank. You don t need to use the Global Paste function to update the settings. You can view and manage these four banks for each actor in the actor library, which makes it easy to switch double-cast actors or accommodate a sudden cast substitution. Channel libraries in Theatre mode include all four bank settings. Channel EQ and dynamics settings configured in Default mode cannot be used in Theatre mode. Similarly, settings configured in Theatre mode cannot be used in Default mode. NOTE In Preview mode, EQ and dynamics parameter settings are not applicable. To switch to Theatre mode: 4. Press the THEATRE button to change the mode. A popup confirmation window appears, informing you that the control surface will be rebooted after the mode is switched. 5. Press the OK button. 1. Press the SETUP button to access the SETUP screen. 2. Press the MAINTENANCE button to access the MAINTENANCE popup window. 3 RIVAGE PM series V2.5 Supplemental Manual

Theatre mode To switch to Theatre mode on the DSP engine: 1. Press the [MENU] key on the front panel of the DSP engine. SELECTED CHANNEL VIEW screen If you select Theatre mode for the UNIT MODE and press the BANK display button, the SELECTED CHANNEL VIEW screen for an input channel will display the following information. 2. Use the []/[] keys to select Unit Mode. 3. Press the [ENTER] key. 4. Use the []/[] keys to select Theatre. Unit Mode Theatre 5. Press the [ENTER] key. 6. The word DONE appears, and then the DSP engine restarts. BANK display button If this button is turned on, the EQ and Dynamics 1 & 2 graphs, and the bank switching buttons will appear. EQ graph This field graphically indicates the approximate EQ and filter response. Bank switching buttons These buttons enable you to switch banks for EQ and Dynamics 1 & 2. Press the selected button to access the NAME EDIT popup window. The corresponding bank and bank name will appear in the EQ and dynamics fields. If the EQ and Dynamics 1 & 2 are linked to a bank, the same bank name will appear in these EQ and dynamics fields. Bank LINK button If this button is turned on, you can link and switch banks (A D) for the EQ and Dynamics 1 & 2 all together as a group. Dynamics graph This field graphically indicates the input/output responses of the dynamics processors 1 and 2. 4 RIVAGE PM series V2.5 Supplemental Manual

Theatre mode Additional display in Theatre mode OVERVIEW screen The actor library name appears on the NAME popup button. If Theatre mode is selected for UNIT MODE, the OVERVIEW screen will contain the following information. In Theatre mode, the NAME/ICON EDIT popup window (accessed by pressing the NAME popup button) will display the name of the actor library on the ACTOR LIBRARY popup button. The actor library name appears in the channel name area. (Press the [SHIFT] key to return to the normal CUE status display.) If the EQ or dynamics parameters are modified, an asterisk (*) will be added to the actor library name. Press the ACTOR LIBRARY popup button to display the ACTOR LIBRARY popup window. HPF/EQ popup window DYNAMICS 1/2 popup window 1 1 1 1 Bank select buttons These buttons enable you to switch banks for EQ and Dynamics 1 & 2. 5 RIVAGE PM series V2.5 Supplemental Manual

Theatre mode To set up a actor library: 1. Press the PATCH button on the menu bar to access the PATCH screen. UPDATE EDITED button Updates all edited channel library settings. RECALL EDITED button Recalls all edited channel library settings. DEFAULT ALL button Cancels all channel library settings and initializes the current EQ and dynamics data in four banks. 3. Configure and/or edit a desired actor library as necessary. NOTE The CH COPY function will not copy any channel-related actor libraries. The CH MOVE function will move a actor library. Input EQ library and dynamics library are shared by Default mode and Theatre mode. However, the EQ and dynamics parameter settings for the input channel library are not shared by both modes. Therefore, in Theatre mode, the EQ and dynamics parameters for input channels will be excluded from being the target of a recall operation. 2. Press the ACTOR tab to access the ACTOR LIBRARY screen. INPUT NAME column Indicates the input channels that can be assigned to a actor library. ACTOR LIBRARY column Indicates the names of configured actor libraries. Press one of the library names to access the ACTOR LIBRARY popup window, in which you can configure the corresponding actor library. UPDATE button Updates the library to reflect current data. RECALL button Recalls the library assigned to the corresponding channel. The edited current data will be overwritten by the recalled library data. DEFAULT button Cancels the library settings and initializes the current data in four banks for EQ and dynamics. INPUT NAME select knob Use the corresponding screen encoder or the [TOUCH AND TURN] knob. 6 RIVAGE PM series V2.5 Supplemental Manual

Improved labeling of the USER DEFINED keys and USER DEFINED knobs Improved labeling of the USER DEFINED keys and USER DEFINED knobs 2. Press a USER DEFINED KEYS (or USER DEFINED KNOBS) button to open the USER DEFINED KEYS (or USER DEFINED KNOBS) popup window. The following example uses a USER DEFINED key. You can now edit the labels for USER DEFINED keys and USER DEFINED knobs. To edit the labels: 3. Press the LABEL tab. 1. Press the SETUP button to access the SETUP screen. 7 RIVAGE PM series V2.5 Supplemental Manual

Dante Domain Manager (DDM) 4. Press the desired USER DEFINED KEYS (or USER DEFINED KNOBS) button to open the USER DEFINED KEYS LABEL (or USER DEFINED KNOBS LABEL) popup window. Dante Domain Manager (DDM) You can now view the configuration status of the Dante Domain Manager (DDM). If the DDM server exists on a network or if the unit is joined to a domain, the DANTE SETUP popup window will display the DANTE DOMAIN MANAGER section. DANTE SETUP popup window USER DEFINED KEYS (or USER DEFINED KNOBS) display Indicates the function assigned to the corresponding USER DEFINED key (or USER DEFINED knob). Press the + button to select the next option, and the - button to select the previous option. USER DEFINED key (or USER DEFINED knob) labeling fields You can use the keyboard to edit the names of the function (TITLE) and parameters (LINE 1-3) that have been assigned to the corresponding USER DEFINED key (or USER DEFINED knob). LED color select buttons Enable you to select the LED color. If the LINE1 or LINE2 field is filled with five or fewer characters, those characters will be displayed in a larger font. Some parameters (such as the TAP TEMPO s BPM value) cannot be changed. DEFAULT button Press this button to return the assigned function, parameter and channel color to their default settings. NOTE If you modified the settings for a function that was assigned to the USER DEFINED key, the settings will revert to their default values. 5. Edit the label as necessary. STATE Indicates the status of the domain join. Domain: The unit is joined to a domain. Disconnected: The unit is joined to a domain, but not connected to the DDM server. Unmanaged: The unit is not joined to a domain. LOCAL Indicates the access status of the Dante settings (including DANTE PATCH) of the currentlyoperated unit. Read Write: You can modify the settings. Read Only: You cannot modify the settings. 8 RIVAGE PM series V2.5 Supplemental Manual

Dante Domain Manager (DDM) REMOTE Indicates the access status of the Dante settings of the external Dante device. Operator: The settings can be both read and written. Guest: The settings can only be read, but not written. None: The settings cannot be read. LATENCY field Indicates the currently-selected latency. If the unit is off-line, the field will indicate ----. SYNC TO EXTERNAL button If this button is turned on, the unit will synchronize with the word clock supplied from the HY slot. Screen variation Part of the following screens will vary depending on the REMOTE setting. DANTE I/O DEVICE [I/O] screen SYSTEM CONFIG popup window Supplemental information regarding the DSP mirroring operation on the Dante audio network If the primary (active) DSP engine fails, the secondary (standby) DSP engine will automatically take over all input/output patches for the TWINLANe network, and the audio will continue seamlessly. However, the secondary DSP engine will not take over the patches for the Dante audio network. Consequently, you need to configure these patches separately. Configure input patches in advance to the Dante cards (HY144-D, HY144-D-SRC) installed in HY SLOT3 on both active and standby DSP engines. Assign a unique control ID to active and standby DSP engines. In addition, apply the same With Recall settings to both DSP engines. Configure output patches from the Dante cards (HY144-D, HY144-D-SRC, Dante MY16-AUD card) that are installed on the RPio622/222. These settings will prevent audio input/output and HA control from being interrupted even when a failover occurs, and the audio will continue seamlessly. Please note that the Dante patches for the Dante card (HY144-D, HY144-D-SRC) inserted in the standby DSP engine cannot be configured in advance. Prepare a Dante preset separately and switch it over manually after a failover occurs. Also, HA control is possible only from a Dante card (HY144-D, HY144-D-SRC) installed in HY SLOT 3 on the DSP engine. HY-256TL RPio M1 HY144-D/ HY144-D-SRC Dante MY16-AUD2 Dante MY16-AUD2 DSP 1A HY-256TL ID # 1 HY144-D/ HY144-D-SRC DSP 1B HY-256TL ID # 2 HY144-D/ HY144-D-SRC Rio ID 001 Rio ID 002 Network Switch Rio ID 003 9 RIVAGE PM series V2.5 Supplemental Manual

Improved screen encoder operation Improved screen encoder operation Improved HY SLOT4 feature You can now use the screen encoders to edit EQ and dynamics parameters on the SELECTED CHANNEL VIEW screen. EQ Dynamics HY SLOT4 (HY SLOT3 on the CSD-R7) now supports input/output patches. Due to this improvement, output channels are now patched via the OUTPUT tab, not on the RECORDING tab. The encoder numbers displayed on the screen correspond to the actual screen encoder numbers. Improved channel name display In SENDS ON FADER mode, the channel on/off status is now indicated in the channel name display area on the panel. Addition input patch setting When you modify input patches, you can now select TAKE FROM PORT or TAKE FROM CHANNEL. If you select TAKE FROM PORT, the HA parameter settings retained by the patched port will be used as is. If you select TAKE FROM CHANNEL, the HA parameter settings retained by the input channel will be copied to the destination port. INPUT patch screen Channel on ch 1 CH 1 - Channel off ch 1 CH 1 - During channel mute, the channel name will be highlighted in the same way as when the channel is off, but it will also be flashing. 10 RIVAGE PM series V2.5 Supplemental Manual

Expanded MIDI transmission/reception on/off function If the TAKE FROM CHANNEL button is turned on, the following HA parameter settings will be copied to the destination port. If you make an input patch from an input that does not retain the HA settings, the initial settings will be used. HA parameters and initial values HA gain ( 6 db) HPF ON/OFF (OFF) +48V ON/OFF (OFF) GC ON/OFF (OFF) Ø ON/OFF (OFF) HPF Frequency (80 Hz) SILK ON/OFF (OFF) SILK RED/BLUE (RED) SILK (0.0) M/S ON/OFF (OFF) M/S S-GAIN (STEREO) These buttons (TAKE FROM PORT and TAKE FROM CHANNEL) have also been added to the INPUT PATCH popup window. Expanded MIDI transmission/reception on/off function You can now use USER DEFINED keys and GPI to turn MIDI transmission and reception on and off. Supported operations Using USER DEFINED keys to turn MIDI transmission and reception on and off for the control surface Using GPI on the control surface to turn MIDI transmission and reception on and off for the control surface Using GPI on the ESP engine to turn MIDI transmission and reception on and off for the DSP engine Supported parameters MIDI PROGRAM CHANGE MIDI CONTROL CHANGE USER DEFINED KEYS popup window 11 RIVAGE PM series V2.5 Supplemental Manual

Additional option in the GAINS SHOWN ON OVERVIEW SCREEN section GPI SETUP popup window Additional option in the GAINS SHOWN ON OVERVIEW SCREEN section The options for the GAIN knob displayed in the GAIN section of the OVERVIEW screen now include AUTO A.G./D.G., in addition to the existing ANALOG GAIN and DIGITAL GAIN options. SCREEN SETTINGS tab on the PREFERENCE popup window If AUTO A.G./D.G. was selected for a bay, and if analog gain is present at a port patched to the channel, this tab will indicate the analog gain option. Meanwhile, if analog gain is not present at the patched port, the tab will indicate the digital gain option. 12 RIVAGE PM series V2.5 Supplemental Manual

Additional library function Additional library function Focus parameters (including Focus function on/off) can now be pasted by using the Global Paste function. All Focus settings can now be stored or recalled as a library. These are the parameters that are cofigureable on the SCENE SETUP (FOCUS) popup window. Focus library data and actor library data have been added as options on the SCENE tab and INPUT/ OUTPUT tab respectively for loading and saving. 13 RIVAGE PM series V2.5 Supplemental Manual

Yamaha Pro Audio global website https://www.yamaha.com/proaudio/ Yamaha Downloads https://download.yamaha.com/ Manual Development Group 2018 Yamaha Corporation Published 09/2018 IP-A0