These documents and software are covered under the terms and conditions of the fp Technologies, Inc. Program License Agreement

Similar documents
Let us ping! First we will learn the Hello World of a networked machine.

GM8126 MAC DRIVER. User Guide Rev.: 1.0 Issue Date: December 2010

Network Configuration for Cisco UCS Director Baremetal Agent

Hostname and IP Address

GMSplus Customer Connection Test Procedure

IP over IB Protocol. Introduction CHAPTER

Access Server: User's and Developer's Guide <<< Previous Next >>>

Chapter 5 Network Layer

Clustered Data ONTAP 8.3 Update 2, IPspaces. Self-paced Lab NETAPP UNIVERSITY. NetApp University - Do Not Distribute

Enabling CDC-ETHER Connection for Skywire CAT1

RG-MACC_2.0 Installation Manual

Getting Started with PetaLinux SDK

Enabling CDC_ETHER Connection for Skywire GSM CAT1

StampA5D3x/PortuxA5/PanelA5. Quickstart Guide

New System Setup Guide

CIS Test 1- Practice - Fall 2011

Copyright 2018, fp Technologies, Inc. of Ohio All Rights Reserved. filepro Installation Windows (Versions 7, 10 and Server Editions)

Configuring a Standalone VCL Environment using VMware Server 2.0

CHAPTER 7 DEMONSTRATE THE PAN IN LINUX

Using Shell Commands

XE2000/XE3000 IP-PBX: Getting Started Guide Package Contents

Quick guide for configuring a system with multiple IP-LINKs

Sirindhorn International Institute of Technology Thammasat University

NVIDIA Professional Application Center

Wi-Fi Guide: Edimax USB Adapter on BBG

RG-MACC-BASE_v2.01. Installation Guide

Configuring the BeagleBone Black s Ethernet Port for SSH Access

Packet Generator User Guider V0.1

Linux. Computer networks - Administration 1DV202. fredag 30 mars 12

HP Services zl Module ngenius Integrated Agent Installation and Getting Started Guide

FiberstoreOS IP Service Configuration Guide

This document guides the user through: 1. Setting up and configuring networking for the BeagleBone black or green with the host.

Packet Generator User Guide V0.4

TABLE OF CONTENTS. ACI Solutions Team by Tomas de Leon 2

Canopy Wireless Broadband Platform

Configuring Real Servers for DSR

WLAN on DILNetPC DNP9200 External SWAP Device on DNP9200

Using Juju with a Local Provider with KVM and LXC in Ubuntu LTS

Create Test Environment

VLAN Configurations. 1 of :18. Available Categories. Adobe. Macromedia

VisibleThread - Server Configuration Help

CS158 - Assignment 9 Faster Naive Bayes? Say it ain t so...

Installation von Oracle Real Application Cluster 10gR1 auf CentOS 4.2 mit Raw-Devices

Silexica Software Licensing Introduction & Installation Version 1.0 English

Hosting Applications Using Configuration Management Tools

High Availability for Cisco RAN Management Systems

Sirindhorn International Institute of Technology Thammasat University

Setting Up A High-Availability Load Balancer (With Failover and Session Support) With HAProxy/Wackamole/Spread On Debian Etch

UNIVERSITY OF BOLTON CREATIVE TECHNOLOGIES. BSc (Hons) COMPUTER NETWORKS AND SECURITY SEMESTER ONE EXAMINATION 2014/2015 UNIX MODULE NO: CPU5003

1. TABLE OF CONTENTS INTRODUCTION TECHNICAL SPECIFICATIONS INSTALLATION... 6

Accessing the Networking Stack

LAN Setup Reflection

LAN Setup Reflection. Ask yourself some questions: o Does your VM have the correct IP? o Are you able to ping some locations, internal and external?

EAN-Network Configuration

JBOX2 (Saturn Ring) Appliance General Guide

CANopen Object Browser, Version 0.2

Renesas Koelsch Hardware Setup and Software Installation

GM8126 U-BOOT. User Guide Rev.: 0.2 Issue Date: May 2011

LevelOne FBR User s Manual. 1W, 4L 10/100 Mbps ADSL Router. Ver


FiberstoreOS. IP Service Configuration Guide

FSOS IP Service Configuration Guide

How to Configure ClusterXL for L2 Link Aggregation

Newsreader virtual machines Technical Report NWR

For personnal use only

Debian/GNU Linux Networking

Oracle 11g RAC on Linux- CRS Inderpal S. Johal. Inderpal S. Johal

Quick Start Guide for BeagleBone Black. Table of Contents. by Brian Fraser Last update: Summer, 2015

UCS IPv6 Management Configuration Example

Basics of GNS3 and Cisco IOS

CHAPTER 7 ADVANCED ADMINISTRATION PC

Adding NetFPGA board into CRON. Change wires table, if you change the switch cable connection

User module. Guest Configuration APPLICATION NOTE

IPv6 Rogue Router Advertisement Attack Prepared By: Andrew Gray & Wil Hall Prepared For: Dr. Tom Calabrese

Raspberry Pi 3 Starter Kit Hookup Guide

Networking Approaches in. a Container World. Flavio Castelli Engineering Manager

Installation Procedure Red Hat 7 with Netscape 6

VIRTUAL GPU LICENSE SERVER VERSION AND 5.1.0

Installing IPM on Windows

INSTALLATION. Security of Information and Communication Systems

Installation Procedure Windows 95/98/ME with Internet Explorer 5.x & 6.0

AirCruiser G Wireless Router GN-BR01G

ssh keys, yum, ntp, rsync

User s Guide. FlexWATCH TM (Version. 3.0_Rev0) Seyeon Technology Co., Ltd. Seyeon Tech Co.

Installation Procedure Windows NT with Netscape 4.x

8.9.2 Lab: Configure an Ethernet NIC to use DHCP in Windows Vista

Installation Procedure Red Hat 7 with Netscape 6

HERMES. Image Display Applications. Installation Manual. HASP USB Security plug Floating License Server Jade Mm3d Rapid for PC Rapid for CD Imagemagic

Taking Advantage of Bluetooth for Communications and More by Hunyue Yau

Deploy Dual Stack CentOS 7 Instance in AWS

Replace HyperFlex Self-Signed SSL Certificates with CA-issued Certificates

PetaLinux SDK Guide to QEMU System Simulation

Windows 95/98 Infoway Connection Instructions 1/4/2002; rev. 1/9/2002

Blueprints. Quick Start Guide for installing and running KVM

Network Management Utility

NetBiter Serial Server User Manual

APPLICATION NOTE. Scope. Reference Documents. Software Ethernet Bridge on SAMA5D3/D4. Atmel SMART SAMA5D3/D4 Series

Motortronics VirtualSCADA VS2-MT Communication Gateway VS2-MT User Manual Revision

ACE Installation and Licensing Guide (UG002) Achronix Devices

Interface Management

Transcription:

Copyright 2017, fp Technologies, Inc. All Rights Reserved These documents and software are covered under the terms and conditions of the fp Technologies, Inc. Program License Agreement You will need to visit our web site www.fptech.net in order to download the correct GIserver GIserver.lic for your configuration. INSTALLATION HELP: Windows Install: 1. Unzip GIserver download file into an empty temporary directory 2. Run Setup.exe from the Windows Start Run dialog box or by clicking on the setup.exe in the temporary directory or CDR if provided. 3. Answer the prompts that the Install Shield asks for. 4. The installation will put a GIserver Icon on your Desktop and/or install GIserver as a Service. 5. Obtain giserver.lic from our website: Before going to the website, make sure you have the following information. * Serial Number of the 5.0 software you are running with GIserver. Port# Giserver will listen to. (4350 is default) * Number Concurrent Connections that you purchased. * Email address that is registered with fp Technologies, Inc. * MAC_Address for the computer that GIserver will be running on. Note: The MAC_Address is entered as 12 characters with no whitespace or punctuation you can find the MAC address of the primary ethernet adapter on a Windows system by using "IPCONFIG /ALL". When running this option, look for a line containing "Physical Address" for your primary Ethernet adapter. You will see one or more devices listed similar to the following: 0 Ethernet adapter : Description........ : PPP Adapter. Physical Address...... : 44-45-53-54-00-00 DHCP Enabled........ : Yes IP Address......... : 0.0.0.0 Subnet Mask........ : 0.0.0.0 Default Gateway...... : DHCP Server........ : 255.255.255.255 Primary WINS Server.... : Secondary WINS Server... : Lease Obtained....... :

Lease Expires....... : 1 Ethernet adapter : Description........ : NDIS 5.0 driver Physical Address...... : 00-E0-7D-91-6C-3A DHCP Enabled........ : Yes IP Address......... : 192.168.0.5 Subnet Mask........ : 255.255.255.0 Default Gateway...... : 192.168.0.2 DHCP Server........ : 192.168.0.2 Primary WINS Server.... : Secondary WINS Server... : Lease Obtained....... : 02 28 03 9:49:02 AM Lease Expires....... : 03 01 03 9:49:02 AM Note that there are two Ethernet adapters identified in the above example, one for the modem (PPP Adapter) and another (NDIS 5.0 driver) for the primary ethernet adapter. The MAC address (Physical Address) of the primary ethernet adapter is displayed as 00-E0-7D-91-6C-3A This value would be entered as 00E07D916C3A when submitting your request for the giserver.lic NOTE: You can also use WINIPCFG to get this information. Point your browser to: Then click on: http://www.fptech.net filepro - Downloads - giserver License File Download - Be careful entering the required information. Once you have entered the information, the resulting giserver.lic file will be locked to that e.g. MAC address, Port and Maximum Concurrent Connection count. You will not be able to re-generate a new giserver.lic file with different settings without contacting fp Technologies sales. You will be able to re-generate another copy with the current settings at any time. 6. Place the downloaded giserver.lic into the ~/fp/giserver/lib directory. 7. Either click on the desktop icon to start GIserver. If you have installed GIserver as a service, you can also use the control panel "Services" icon to initially start the service. The service will be automatically started for you on subsequent system startups. Refer to Windows "Services" for more detail. 8. After installing GIserver, install GIadmin to manage/update your GIserver

installation(s). Refer to GIadmin Installation for further details. SCO UNIX Install: SCO Open Server 5.0.5 GIserver Installation Notes If you have a previous version of OSR5 you MUST upgrade to version 5.0.5., have the UDK Compatibility Software Version 7.11 (OSRcompat711) and java2.jre2 installed in order to run GIServer. (See instructions below). giserver.gz is a gzipped tar file. To gunzip giserver.gz you must have 'gunzip'. If you do not have it you can download gzip.tar from the "Download" section of our web site, www.fptechnologies.com. cd to a directory that is in the PATH then extract gzip.tar with: tar xvf gzip.tar To gunzip giserver.gz type: gunzip giserver.gz Once gunzipped it will be called GIserver. GIserver can be installed in the same directory where you keep filepro but it is usually kept in a separate directory, for example, (/appl/fp), however, GIserver does not have to be installed on the same machine that has filepro. It can be kept on another machine on the network. To install GIserver: 1. Change to the directory where you have decided to install GIserver. In this example we will use /appl/fp for the install directory and /tmp/giserver for the location of the GIserver tarball. cd /appl/fp 2. Extract giserver with: tar xvf /tmp/giserver 3. To finish the install:./giserver.finish 4. Obtain file giserver.lic from our website: Before going to the website, make sure you have the following information. * Serial Number of the 5.0 software you are running with GIserver. Port# Giserver will listen to. (4350 is default) * Number Concurrent Connections that you purchased.

* Email address that is registered with fp Technologies, Inc. * MAC_Address for the computer that GIserver will be running on. Note: The MAC_Address is entered as 12 characters with no whitespace or punctuation you can find the MAC address of the primary ethernet adapter on your SCO system by using "ifconfig -a" and look for a line containing "ether" for your primary Ethernet adapter. AN example of what you will see when running "ifconfig -a" follows. lo0: flags=4049<up,loopback,running,multicast> mtu 16384 inet 127.0.0.1 netmask ff000000 inet/perf: recv size: 49152; send size: 49152; full-size frames: 1 inet/options: -rfc1323 net0: flags=4043<up,broadcast,running,multicast> mtu 1500 inet 64.220.102.170 netmask ffffffe0 broadcast 64.220.102.191 inet/perf: recv size: 24576; send size: 24576; full-size frames: 1 inet/options: rfc1323 ether 00:10:5a:20:cd:c4 The MAC address (ether) of the primary ethernet adapter is displayed as 00:10:5a:20:cd:c4 This value would be entered as 00105a20cdc4 when submitting your request for the giserver.lic Point your browser to: Then click on: http://www.fptech.net filepro - Downloads - giserver License File Download - Be careful entering the required information. Once you have entered the information, the resulting giserver.lic file will be locked to that e.g. MAC address, Port and Maximum Concurrent Connection count. You will not be able to re-generate a new giserver.lic file with different settings without contacting fp Technologies sales. You will be able to re-generate another copy with the current settings at any time. 5. Place the downloaded giserver.lic into the ~/fp/giserver/lib directory. IMPORTANT: GIserver on OSR5.0.5 REQUIRES the UDK Compatibility Software Version 7.11

(OSRcompat711) and java2.jre2 in order to run. Un-install any previous version of UDK Compatibility Software before installing OSRcompat711. To install OSRcompat711: Download DL27510P000.tar Move DL27510P000.tar file into a directory called osrcompat Change to the./osrcompat directory Extract the file with: tar -xvf DL27510P000.tar Uncompress the resulting file with: uncompress OSRcompat.711.pkg.Z Install OSRcompat.711.pkg with: pkgadd -d /OSRcompat.711.pkg YOU ALSO NEED java2.jre2. If you already have a previous version of java installed it does not have to be uninstalled; however, you do need to put /usr/jre2/bin into the PATH prior to the existing java address. On LINUX servers: The distribution CD contains all files needed to install GIserver on Linux platforms. The java2 installation varies depending on the platform you are running. There is a separate Readme_java file for each platform supported. The first step is to extract the GIserver files (into /appl/fp recommended) and run giserver/finish. See Readme_giserver (Readme_fpserver) for instructions. If you don't have a proper version of java2 installed you will be informed and told which java package to install. The java2 installation varies depending on the platform you are running. There are separate Readme_javaPLATFORM and java2jre2_platform.tar files for each platform supported. ---------------------------------------------------------------------------- Installing java2: --- GIserver requires java2 version 1.2 or better.

If you are using the GIserver CD then mount the CD using the instructions that you received with the CD. If you downloaded giserver.gz off of the web site then the files you will need to install java2 are in rpm format in java2jre2_rpm.tar and selfextracting binary format in java2jre2_linux.tar. They are located under Utilities - linux. Download the appropriate file to the /mnt directory. java2jre2_linux.tar contains j2re_1_3_0-linux.bin and java2jre2_rpm.tar contains j2re-1_3_0-linux.rpm.bin. ---------------------------------------------------------------------------- To install j2re_1_3_0-linux.tar: If not already root enter: su Move to /usr/java directory Extract j2re-1_3_0-linux.bin Install j2re-1_3_0-linux.bin cd /usr/java tar xvf java2jre2_linux.tar./j2re-1_3_0-linux.bin java2 is installed. ---------------------------------------------------------------------------- To install j2re_1_3_0-linux-rpm.tar: If not already root enter: su Move to /usr/java directory Extract j2re-1_3_0-linux-rpm.bin Extract j2re-1_3_0-linux.rpm Install j2re-1_3_0-linux.rpm cd /usr/java tar xvf java2jre2_rpm.tar./j2re-1_3_0-linux-rpm.bin rpm -iv j2re-1_3_0-linux.rpm Note: It can happen that your installation may fail with a message such as "glibc >= 2.1.2-11 is needed by jre-1.3" even though glibc2.1.29 (or greater) is on your system. This can happen when your glibc was not installed as part of an rpm package and is therefore not on the rpm file list. In that case, this JRE 1.3 rpm installation package won't recognize that glibc is installed. To force the JRE 1.3 installation to proceed, use the --force option: rpm -iv --force j2re-1_3_0-linux.rpm

---------------------------------------------------------------------------- To install the Java Plug-in follow these steps: Uninstall previous installation of the Java Plug-in, if applicable. rm -fr $HOME/.netscape/java rm $HOME/.netscape/plugins/javapulugin.so Set the NPX_PLUGIN_PATH environment variable: export NPX_PLUGIN_PATH=/usr/java/jre1.3/plugin/i386 Start your Netscape browser. If your browser is already running, close it and restart it. Close and restart your Netscape browser again. This is necessary because of bug 4358142. --------------------------------------------------------------------------- GIserver Installation Notes: 12/26/00 If you are using the GIserver CD then mount the CD using the instructions that you received with the CD. giserver.gz is a gzipped tar file. If you don't have 'gzip' see the Readme_java for your operating system. In this Readme the /mnt directory will be used to download/install all packages. -------------------------------------------------------------------------------- Installing GIserver Linux--- GIserver will normally be installed in an giserver directory under the fp directory. If the fp directory is /appl/fp, then when the install is complete, there will be an /appl/fp/giserver directory and giserver.jar will be in it. To install GIserver: 1. Change to the directory where you have decided to install GIserver. In this example we will use /appl/fp for the install directory and /mnt/giserver.gz for the location of the GIserver tarball. cd /appl/fp 2. Extract giserver with:

tar xvf /tmp/giserver 3. To finish the install: giserver.finish 4. Obtain file giserver.lic from our website: Before going to the website, make sure you have the following information. * Serial Number of the 5.0 software you are running with GIserver. Port# Giserver will listen to. (4350 is default) * Number Concurrent Connections that you purchased. * Email address that is registered with fp Technologies, Inc. * MAC_Address for the computer that GIserver will be running on. Note: The MAC_Address is entered as 12 characters with no whitespace or punctuation you can find the MAC address of the primary ethernet adapter on your SCO system by using "ifconfig". look for a line containing "HWaddr" for your primary Ethernet adapter. You will see one or more devices listed similar to the following. eth0 Link encap:ethernet HWaddr 00:50:DA:0D:1B:C0 inet addr:64.220.102.180 Bcast:64.220.102.191 Mask:255.255.255.224 UP BROADCAST RUNNING MULTICAST MTU:1500 Metric:1 RX packets:77134 errors:0 dropped:0 overruns:0 frame:0 TX packets:24540 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:100 RX bytes:46417456 (44.2 Mb) TX bytes:4504332 (4.2 Mb) Interrupt:11 Base address:0x1000 lo Link encap:local Loopback inet addr:127.0.0.1 Mask:255.0.0.0 UP LOOPBACK RUNNING MTU:16436 Metric:1 RX packets:692 errors:0 dropped:0 overruns:0 frame:0 TX packets:692 errors:0 dropped:0 overruns:0 carrier:0 collisions:0 txqueuelen:0 RX bytes:48363 (47.2 Kb) TX bytes:48363 (47.2 Kb) Note that there are two Ethernet adapters identified in the above example, one for the modem (PPP Adapter) and another (NDIS 5.0 driver) for the primary ethernet adapter. The MAC address (Physical Address) of the primary ethernet adapter is displayed as 00:50:DA:0D:1B:C0 This value would be entered as 0050DA0D1BC0 when submitting your request

for the giserver.lic Point your browser to: Then click on: http://www.fptech.net filepro - Downloads - giserver License File Download - Be careful entering the required information. Once you have entered the information, the resulting giserver.lic file will be locked to that e.g. MAC address, Port and Maximum Concurrent Connection count. You will not be able to re-generate a new giserver.lic file with different settings Without contacting fp Technologies sales. You will be able to re-generate another copy with the current settings at any time. 5. Place giserver.lic into the /appl/fp/giserver/lib directory. 6. Giserver is now ready to run. GIserver can be started from either a term window or a character screen by typing:./startgi& from within the ~/appl/fp/giserver directory. -------------------------------------------------------------------------------- Configuring GIserver --- To start GIserver type: GIserver The first time you run GIserver you will need to 'Setup Users'. To do this Click on 'Edits' then select 'User Configuration'. Double-click on 'username.cfg' and change the 'password:' field to the password for the first user. Make sure to press when leaving the field or the field value will NOT be changed. Click on 'file' then 'save-as' and enter an appropriate filename. If the user's Unix login name is 'fred' - then use 'fred.cfg'. Repeat this process for all users. If you need to review these instructions they are in./fp/readme.giserver. Change History for GIserver

* 1.13 added GracePeriodWarning * 1.14 modified Producer.doRawMode to use BufferedOutputStream * 1.15 bug fix for change in 1.14 * 1.16 internally buffer raw mode input until newline or end_of_raw_mode sequence received * 1.17 back out 1.16 changes * 1.18 flush raw mode output stream before 'sleep' if anything in buffer * 1.19 now accept (and log) version number of filepro programs in PROCESS_INIT message * 1.20 set FPCLIENT_FEATURE=7 for GIclient connections - tmp workaround for filepro purposes * 1.21 use FileInputStream and byte[] for reading license * instead of FileReader and char[] to avoid encoding problems * 1.22 FEATURES_FLAG changes to CONNECTION_INFO message for Ken * 1.23 Changed server response to too many connections * now the server sends a message and closes the socket * 1.24 numerous changes for admin module * 1.25 fix for raw mode timing bug - moved mode switch to before buffer flush * 1.26 changed secondary license file updating to remove requirement for * Java 1.3 or beyond * 1.261 fixed potential "NullPointerException" in logging in Producer.doRawMode * 1.262 added debug code to show when messages are actually sent * 1.263 made raw mode sleep code conditional on Windows platform * 1.264 additional debugging code * 1.265 additional debugging code * 1.266 additional debugging code - Message Types as text * 1.267 added sending log files to admin module for remote viewing * 1.268a added 1.4 conditional code to force disk updates * 1.269 only call 1268a conditional code when logs are requested by GIadmin module * 1.270 added debugging info for forced updates * 1.271 removed additional debugging info for forced updates * 1.272 added logging (in server.err) of failed admin logins * 1.300 modified license file format to accommodate disconnected windows laptops * 1.301 only do check for primary drive serial number on Windows * 1.302 closed hole where 000000000000 was considered a valid MAC address for licensing * fixed bug introduced in 1.300 where only the first of multiple MAC addresses was checked * 1.303 added logging of default user properties to logging of environment (if logenvironment=true is set for user * 1.304 modified loading of gethost library to show java.library.path if load fails * 1.305 modified login routines to allow for empty password * if expires (in giserver.cfg) is set to anything other than 0 empty password are disallowed Copyright 2000-2017, fp Technologies, Inc. All Rights Reserved These documents are covered under the terms and conditions of the fp Technologies, Inc. Program License Agreement rev. 02/28/2003