CHEMISTRY DEPARTMENT Category Work Instruction

Similar documents
Delta V5 operation. Widetron Technologies Corp. Wu, Chung Ying. Progress through Synergy

NMR INSTRUMENT INSTRUCTIONS: Safety and Sample Preparation

JABATAN KIMIA Kategori Arahan Kerja

NMR Spectroscopy with VnmrJ. University of Toronto, Department of Chemistry

NMR Users Guide Organic Chemistry Laboratory

Bruker Avance 400 MHz Instructions

VNMRJ 4.2 INSTRUCTIONS: QANUC 500 FOR CHEMISTS

MNova Version Installation Instructions.

VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400

VNMRJ 4.2 INSTRUCTIONS: VARIAN MERCURY 400 AND VARIAN VNMRS 500

Vanderbilt Small Molecule NMR Center

Bruker AVANCE III HD 400 MHz Spectrometer Operation

CyAn ADP Guide. Starting Up

Seized Drugs Operational Guidelines for the Shimadzu UV/VIS Comparative and Analytical Division

Short instructions for the basic operation of the AVANCE II 400 MHz Bruker NMR Using ICON-NMR (PS751)

1D NMR Training Manual for Operating the Bruker 700 MHz Avance III HD NMR. Spectrometer without the Sample Changer and IconNMR

Using OPUS to Process Evolved Gas Data (8/12/15 edits highlighted)

Varian Solution NMR Procedure

PANalytical Epsilon 5 XRF spectral acquisition, processing and reporting

IMSERC NMR MANUAL 02: Basic Processing of Varian 1D NMR Data

Nicolet is50 FTIR User s Booklet

Import and preprocessing of raw spectrum data

NMR Training VNMRJ 4.2A/VNMRS 400

Varian Solution NMR Automation Procedure (VNMRS Machines running VNMRJ 4.2 under Red Hat Enterprise 5.1)

CH142 Spring Spectrophotometers with Vernier Data Acquisition Software

KeePass Password Safe: Password Manager

Autodesk Fusion 360 Training: The Future of Making Things Attendee Guide

Basic tasks in Excel 2013

IRIS Hosted Systems Apple Mac Installation Guide

Brief IconNMR and Topspin 3.5 User Guide for Bruker NMR Spectrometers Avance IIIHD 400MHz NMR with Autosampler in Chemistry room 93 DISCLAIMER

V-600 Operation. JASCO V-600 for Windows Software Manual

Hitachi U-2001 UV/Vis Spectrometer Updated November 14, 2017

CBCL Limited Tool Palettes Tutorial 2012 REV. 01. CBCL Design Management & Best CAD Practices. Our Vision

Client Setup Manual (Thunderbird) Version 1.0

Step 1: Open the CAD model

May 2015 Tips for Student 1 1 Laptop Use

Bruker Topspin NMR Training Manual

General Information for Automated Inova 500 MHz NMR (Indy)

Using the Subscriber Manager GUI Tool

GENERAL NAVIGATION REFERENCE GUIDE FOR BANNER 7.X

TopPoint User's Guide

Agilent VnmrJ 3.2. Quick Start Guide

TopSpin QuickStart. Default State TopSpin should be running at all times. If this is not the case, you may need to Log In and Start TopSpin.

ETT Olfactometer C. Direct Control Software Manual

Quick Start Guide. Introduction. Importing Raw Data. Method 1: Use Open Data Panel

Parallels Remote Application Server

VRABE Outlook Web Access (OWA)Basics

Using the Bruker Tracer III-SD Handheld X-Ray Fluorescence Spectrometer using PC Software for Data Collection

English. For Windows. WebAccess. User Manual. Buffalo Inc.

Library ebooks and Your B&N Nook

3 AXIS STANDARD CAD. BobCAD-CAM Version 28 Training Workbook 3 Axis Standard CAD

Expedient User Manual Getting Started

Creating a Wireflow Diagram

Spectrometer Visible Light Spectrometer V4.4

Bruker NMR Topspin Manual

Adobe Creative Cloud Installation for MacOS

NMR Spectrometer Crib-Sheet

Exercise 4a: Creating and Editing XY Plots

Using Blackboard Drive to upload/manage content in Blackboard Learn

Tech Note. ConnectWise PSA Integration

Ground Game Management

Welcome to InSite: A GUIDE TO PROOFING ONLINE. Getting Started Viewing Job Information Uploading Files Viewing Pages Requesting Corrections

Immotec Systems, Inc. SQL Server 2008 Installation Document

Fairfield University Using Xythos for File Storage

Banner eprint Instructions

Installing VPN client by Jupiter Networks:

5 Setting Preferences 15 Preferences 15 Configure Chart Colors 16

Citrix Desktop for Home Computers Mac OS Instructions

Aqueous GPC Instructions - Detailed

Objective New User Guide

Windows 10 - Starter Guide

Alternate Submission Methods

User s Guide The SimSphere Biosphere/Atmosphere Modeling Tool

Perkin-Elmer Lambda 3B Spectrophotometer

Banner 9. Navigation Guide Revised for Ithaca College Fall The URL for Banner 9 is

67 Series Spectrophotometer PC Software

Fitting NMR peaks for N,N DMA

Acquiring Data in VnmrJ 4.2A

Remote Workspace. Nubo End User Guide. Version: 1.3 Date: June, Copyright 2017 by Nubo Inc. All rights reserved. Page 1

Sema Foundation ICT Department. Lesson - 18

Trace Bitmap. Chapter 7. A. Page Size. Step 1. Click File Menu > New (Ctrl-N).

Impero Learning Series Teacher Tips English

2015 Optima Healthcare Solutions Page 2

The Veritext Vault. User Guide. Veritext s Secure Online Depository. THE VAULT USER GUIDE Updated 8/24/16 1

TRAINING GUIDE WCS - VIEW MANAGER - PART-2

Unscrew and remove the cap from the waste tank

Galaxie Photodiode Array Software

GLOBUS FILE TRANSFER TUTORIAL

BROWSER-BASED SUPPORT CONSOLE USER S GUIDE. 31 January 2017

PaperClip32. Revision 2.0

Immotec Systems, Inc. SQL Server 2008 Installation Document

SSL VPN Web Portal User Guide

Modeling a CPU case. Lesson 5. This tutorial illustrates how to create the external case of a Central Processing Unit using the following commands.

IBM NetBAY Virtual Console Software. Installer and User Guide

Chapter 1: Introduction

Quick Start Guide Getting started with NSN Connect

Jasco 4700 FTIR. Laser Spectroscopy Labs. Jasco 4700 FTIR. Operation instructions. Laser Spectroscopy Labs, UCI

PDS OnDemand. Getting Started Guide for Windows

Printing and Scanning

Appserv Internal Desktop Access Mac OS Device with Safari Browser. Enter your Appserv username and password to sign in to the Website

Transcription:

No. of pages: 1 of 10 1. PURPOSE The purpose of this procedure established is to provide clear instructions for steps or orders on how to run sample analysis using JEOL NMR ECX 400MHz SYSTEM JOEL equipment. 2. SCOPE Applied for user from Chemistry Department. 3. INSTRUCTIONS PROCEDURE 3.1 Delta STARTUP AND CONNECTION a) Air Compressor ON mode. b) Type Ctrl + Alt + Delete at a time. Username: delta Password: delta (displayed as asterisks (*****) ). c) Double-click the Delta icon on the desktop. d) The Delta console window opens. Delta console window e) Click the circled button indicated in the figure below. f) The Spectrometer control window opens. SPECTROMETER CONTROL WINDOW

No. of pages: 2 of 10 g) Select a spectrometer displayed in the Spectrometer Control window. h) Clicking the connection button switches to the User Authentication window. User authentication window i) Type the user name and the password. - Name delta - Password: delta ( displayed as asterisks ( ***** ) Kata kunci: **** (karakter yang dimasukkan berada dalam paparan asterisks ) j) Click the button. k) The window view changes as shown below. After completion of user authentication

No. of pages: 3 of 10 3.2 SAMPLE PREPARATION a) Mount the sample tube on the sample rotor and the holder. Sample mounting b) Set the sample tube set in the sample rotor and holder so that it floats in the SCM. #When using the auto-sample changer, place the tube in the slot. Setting the sample tube unit on the SCM IMPORTANT NOTICE : Before making the sample float in the SCM,check that floating air emerges. Check that no sample is inside the SCM. Do not insert a bare glass tube or the empty rotor and holder.

No. of pages: 4 of 10 3.3 PREPARATION FOR MEASUREMENT (a) Creating Sample Definitions A sample definition is: Conditions of a sample to be measured. 1. Click the button to create a new sample definition ( see the figure below ). Creating sample definitions Details of the parameters displayed in the sample definitions: Item Description Add a sample definition Delete a sample definiton Sample name Arbitrary ( used as a part of a saved name ) Solvent Select a solvent. Select a sample slot ( if an auto sample changer is integrated ). Slot Select a sample slot ( if an auto sample changer is integrated ).

No. of pages: 5 of 10 (b) Creating a Job A job is: A process of configuring conditions for performing an NMR measurement. 1. Click the button displayed in the Spectrometer Control Window. SPECTROMETER CONTROL WINDOW 2. The window automatically switches to the Job tab. Jobs tab

No. of pages: 6 of 10 3.4 1H MEASUREMENT a) Click the button to select a pulse sequence. (q) Selecting a pulse sequence b) Select basic / proton.jxp. ( If not found, search by double clicking ). c) Select the pulse sequence to use, and then click the button. d) The measurement is started by clicking the button. Note: The sample preparation, sample definition creation, job creation and measurement have been

No. of pages: 7 of 10 described. These are basic procedures for performing measurements using Delta V5. This procedure should be practiced in order to achieve a smooth measurement process. 3.5 1H DATA PROCESSING When the NMR measurement is completed, the measurement result is displayed on the screen. a) Peak Picking 1. Select the button in the toolbar to determine the threshold. i) Automatic detection Peak picking is performed by clicking the button. After peak picking 2. Integration i. Automatic detection 1. An integral curve can be automatically detected by clicking the button. ii. Adding and deleting a selected integral curve 1. To draw an integral curve separately, select the button in the toolbar.

No. of pages: 8 of 10 2. An integral curve can be created by dragging a selected part on the X axis. Dragging right and left iii. Saving processed data 1. Select File from the pull-down in the 1D Processor window. 2. The data can be saved by using Save as. 3.6 PRINTING DATA a) Clicking the button opens the printing option window. 3.7 13C MEASUREMENT a) Measurement i. Create a new job or add parameters to an existing job. a. Click the button to select basic / carbon.jxp. b. ( If not found, search by double clicking ). ii. Change the parameters as needed. iii. The measurements is started by clicking the button. b) Data processing Perform the processing for the acquired spectrum. Follow the same procedure as 1H.

No. of pages: 9 of 10 Phase Correction Reference setting Peak picking 3.8 DEPT MEASUREMENT a) Measurement i. Create a new job or add parameters to an existing job. a. Click the button to select basic / dept.jxp. b. ( If not found, search by double clicking ). ii. Change the parameters as needed. [Pulse] tab: selection_angle=135[deg] The parameter above can be changed to 45[deg], 90[deg], or 135[deg]. iii. The measurement is started by clicking the button. 3.9 DATA SAVE LOCATION a) Opening Past Data i. Click the button in the [delta] console window. Delta console window and file browser window

No. of pages: 10 of 10 ii. The File Browser window appears. iii. Click the button. iv. The selected data is opened by clicking the button. When the saving location for a certain data is changed, specify the location separately. The data once displayed on the screen is saved in the folder. 4. RELATED PROCEDURES Instrument Usage/Service Application Procedure GP-I-001 5. REFERENCE CHECKING REVISION PREPARED BY CHECKED BY DATE REMARK 1 Sugakumar A/L Varuthan Dara Fiona Mohamad Fateh Ngaliman 31.07.2018 1 st issue