X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection

Similar documents
HIGH RESOLUTION COMPUTED TOMOGRAPHY FOR METROLOGY

*Corresponding author:

Computed Tomography & 3D Metrology Application of the VDI/VDE Directive 2630 and Optimization of the CT system

Traceable 3D X-Ray Measurements ZEISS METROTOM

Coordinate Measuring Machines with Computed Tomography

Quality control phantoms and protocol for a tomography system

Optiv CT160 Accurate measurement for every detail. Computed Tomography System

Advanced Non-Destructive Testing by High Resolution Computed Tomography for 3D analysis of Automotive Components

Developments in Dimensional Metrology in X-ray Computed Tomography at NPL

Parameter Dependent Thresholding for Dimensional X-ray Computed Tomography

CT Reconstruction with Good-Orientation and Layer Separation for Multilayer Objects

Advanced Computed Tomography System for the Inspection of Large Aluminium Car Bodies

Comparision of contact and contactless measuring methods for form evaluation

Thickness Measurement of Metal Plate Using CT Projection Images and Nominal Shape

3D X-ray Laminography with CMOS Image Sensor Using a Projection Method for Reconstruction of Arbitrary Cross-sectional Images

CIVA Computed Tomography Modeling

Wieblinger Weg 92a, Heidelberg, Germany, Phone: , Fax: ;

A new concept for high-speed atline and inline CT for up to 100% mass production process control allowing both 3D metrology and failure analysis

Industrial Computed Tomography

Advanced automated High Speed Computed Tomography for production process control. DGZfP 2011, Bremen

Characterization of microshells experimented on Laser Megajoule using X-Ray tomography

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

A new Concept for High-Speed atline and inlinect for up to 100% Mass Production Process Control

Uncertainty Evaluation of Pore Analysis for Additively Manufactured Parts using Cross Sections

Industrial Computed Tomography Innovations

Japan Foundry Society, Inc. Application of Recent X-ray CT Technology to Investment Casting field. Kouichi Inagaki ICC / IHI Corporation

Simulation of Radiographic Testing for POD Assessment

CT in Dimensional Metrology, Engineering and Manufacture

Adapted acquisition trajectory and iterative reconstruction for few-views CT inspection

MULTI-PURPOSE 3D COMPUTED TOMOGRAPHY SYSTEM

The Electrochemical Innovation Lab X-ray Suite: from macro- to nano-ct

Evaluation strategies in CT scanning

räíê~_êáöüí Microfocus X-Ray Source Technical Data Sheet X-Ray Tube Unit Specifications

HIGH-SPEED THEE-DIMENSIONAL TOMOGRAPHIC IMAGING OF FRAGMENTS AND PRECISE STATISTICS FROM AN AUTOMATED ANALYSIS

Enhanced material contrast by dual-energy microct imaging

High-resolution X-ray CT Inspection of Honeycomb Composites Using Planar Computed Tomography Technology

Dr. Javier Santillan, San Carlos, CA

Micro-CT in geosciences: Getting the inside story. Wesley De Boever

Reducing the influence of environmental scattering in industrial computed tomography by system optimisation and correction algorithms

Comparison of Probing Error in Dimensional Measurement by Means of 3D Computed Tomography with Circular and Helical Sampling

Multi-spectral (W, Mo, Cu, and Ag) XCT measurements

MCT225 HA Metrology CT

Introduction to Biomedical Imaging

Using X-Ray Micro Tomography to assess the quality of Packaging Foil

The new generation of industrial computed tomography. The Desktop CT exact S

Improved Inspection of Miniaturized Interconnections by Digital X-ray Inspection and Computed Tomography

Case Studies in the Use of Computed Tomography for Non-Destructive Testing, Inspection and Measurement

X-ray Industrial Computed Laminography (ICL) Simulation Study of Planar Objects: Optimization of Laminographic Angle

AM INSPECTION / NDT: IS XCT THE SOLUTION?

Roger Wende Acknowledgements: Lu McCarty, Johannes Fieres, Christof Reinhart. Volume Graphics Inc. Charlotte, NC USA Volume Graphics

Industrial Computer Tomography for Dimensional Metrology: Overview of Influence Factors and Improvement Strategies

THE CRITICAL ROLE OF HIGH RESOLUTION X-RAY MICRO- COMPUTED TOMOGRAPHY FOR ULTRA-THIN WALL SPACE COMPONENT CHARACTERIZATION

Investigation of the kinematic system of a 450 kv CT scanner and its influence on dimensional CT metrology applications

Digital Laminography and Computed Tomography with 600 kv for Aerospace Applications

Image Acquisition Systems

Frequency-based method to optimize the number of projections for industrial computed tomography

Fits you like no other

ASSESSMENT OF MEASUREMENT UNCERTAINTY CAUSED IN THE PREPARATION OF MEASUREMENTS USING COMPUTED TOMOGRAPHY

Digital Image Processing

PLANMECA PROMAX 3D MID CBCT UNIT

Digital Volume Correlation for Materials Characterization

A cone-beam CT geometry correction method based on intentional misalignments to render the projection images correctable

O-ARM IMAGING SYSTEM TECHNICAL SPECIFICATION GUIDE

Recognition and Measurement of Small Defects in ICT Testing

Introduction to XCT and its growth

DEVELOPMENT OF CONE BEAM TOMOGRAPHIC RECONSTRUCTION SOFTWARE MODULE

Background. Outline. Radiographic Tomosynthesis: Image Quality and Artifacts Reduction 1 / GE /

3D Computed Tomography (CT) Its Application to Aerospace Industry

Investigating the influence of workpiece placement on the uncertainty of measurements in industrial computed tomography

The new generation of industrial computed tomography. The CT workstation exact M

Porosity and Pore-Size Distribution of Geomaterials from X-Ray CT Scans

Applying Hounsfield unit density calibration in SkyScan CT-analyser

A Large Scale Multiple Source X-ray CT System for Aerospace Applications

Fits you like no other

Novel Magnetic Field Mapping Technology for Small and Closed Aperture Undulators

CT Systems and their standards

OptiCon X-Line 3D. Combined 3D X-ray and Optical Inspection at Production Line Pace

GLAST. Prototype Tracker Tower Construction Status

Investigation on the influence of image quality in X-ray CT metrology

Pipe Inspection with Digital Radiography

Characterization of Powder Injection Molded Components Using X-Ray CT. David P. Harding, Zhigang Zak Fang, C.L. Lin, Jan D. Miller

An initial experimental study on the influence of beam hardening in X-ray CT for dimensional metrology

Reconstruction Methods for Coplanar Translational Laminography Applications

Industrial Computed Tomography in Biomedical Engineering

STUDY ON PARAMETER VARIATION OF AN INDUSTRIAL COMPUTED TOMOGRAPHY SIMULATION TOOL CONCERNING DIMENSIONAL MEASUREMENT DEVIATIONS

Introduction to computed tomography

arxiv: v2 [cond-mat.mtrl-sci] 5 Jan 2010

Deep Scatter Estimation (DSE): Accurate Real-Time Scatter Estimation for X-Ray CT using a Deep Convolutional Neural Network

Methods for Quantitative Characterization of Large-Scale High Energy Computed Tomography Systems

LABORATORY SYSTEM FOR X-RAY NANOTOMOGRAPHY

Joint ICTP-TWAS Workshop on Portable X-ray Analytical Instruments for Cultural Heritage. 29 April - 3 May, 2013

SUPPLEMENTARY INFORMATION

On the impact of probing form error on form measurement in Computed Tomography

Continuation Format Page

Distance measurements on inaccessible wires in plastic parts with X-ray computed tomography

How beam hardening influences the dimensional geometry in X-ray computed tomography

Latest developments in 3D analysis of geomaterials by Morpho+

Planmeca ProMax 3D s CBCT unit

Advanced Reconstruction Techniques Applied to an On-Site CT System

Medical Image Processing: Image Reconstruction and 3D Renderings

Transcription:

X-rays see all X-ray computed microtomography (µct) a novel technique available at CERN for material and metrological inspection Mariusz Jedrychowski EN/MME-MM

Introduction of new technique at CERN 12/12/2017 Shipment of Zeiss Metrotom CT 1500 to Bdg. 100. The lead-shielded closed-cabinet system came assembled in a 8100 kg truck pallet. 16/05/2018 Article on CERN Bulletin 08.10.2018 X rays see all 2

Open Day 6 th June 2018 08.10.2018 X rays see all 3

What we can see with X-rays? An x-ray radiograph of A Misereuse Accroupie Photography by Craig Boyko/Art Gallery of Ontario Wilhelm Roentgen 08.10.2018 X rays see all 4

What we can see with X-rays? Voids / filling imperfections Brazing inspection Molibden-Graphite prototype collimation material for HL-LHC (WP5-Collimation ARIES) High X-ray absorption inclusions Electric circuit 08.10.2018 X rays see all 5

µct outstanding possibility to see and analyse in 3D Inclusion analysis for Mo-Gr samples 08.10.2018 X rays see all 6

µct outstanding possibility to see in 3D Superconducting cable for ITER project Voltage: 225 kv, Distance: 160 mm Voxel size: 50 µm, Projections: 2000, Integration time: 2 s, Measurement time: 2.5 h Top View Front View 08.10.2018 X rays see all 7

µct outstanding possibility to see in 3D Superconducting cable for ITER project 08.10.2018 X rays see all 8

µct outstanding possibility to see in 3D Superconducting cable for ITER project 08.10.2018 X rays see all 9

µct outstanding possibility to see in 3D CLIC Spiral Load 3D printed titanium object Voltage: 220 kv, Distance: 750 mm, Voxel size: 111 µm, Projections: 2050, Integration time: 1000 ms, Measurement time: 1.5 h 08.10.2018 X rays see all 10

Overview 1. X-ray computed tomography Short introduction Possibilities: NDT, metrology 2. Zeiss Metrotom CT specification 3. Software 4. Applications gallery 5. X-rays see all. How far we can see with µct in practice? 6. Image processing techniques developed at CERN 08.10.2018 X rays see all 11

X-ray computed (micro)tomography - µct Tube/detector distance determines the available measuring range: Flat image detector high-resolution: 2048 x 2048 pixels Projections 2D radiography Piece Regions with different X-ray absorption X-ray tube determines the range of applications: a smaller focal spot is used for high resolution, a higher voltage is used for more absorbent (denser/thicker) pieces Rotary table Precision axes The workpiece can be moved on four axes with extreme precision provided by coordinate measuring technology which, in result, allows metrology measurements. 08.10.2018 X rays see all 12

X-ray computed (micro)tomography - µct 30 cm 08.10.2018 X rays see all 13

X-ray computed (micro)tomography - µct 22.5º 3D reconstruction 3D set of grey level voxels Projections 2D radiography 08.10.2018 X rays see all 14

Zeiss Metrotom CT X-ray generator Detector Sample holder Rotary table 15 08.10.2018 X rays see all 15

Zeiss Metrotom CT Specification Microfocus X-ray tube: Max. voltage 225 kv Max. current 3000 µa Max power 500 W Min. focal spot size 7 µm High resolution flat panel imager: 40 x 40 cm 2048 x 2048 pixels, 16 bit Material Polymer > 300 Aluminium 300 Titanium 200 Steel 50 Copper 20-30 Max. through thickness [mm] Tube-detector distance: 1375 mm Max. spatial resolution: 4 μm Inoptimum conditions: small piece and contrasting materials. Typically voxel size is 10 to 100 μm Max through thickness Length measurement error [µm]: 9 μm + L/50 08.10.2018 X rays see all 16

Sample size vs voxel size extended field of view Carbon piece for ALICE detector Horizontal and vertical extensions used, 5 scans merged, Voltage: 190 kv, Distance: 437 mm, Voxel size: 65 µm, time: 6.5 h CT data size: 112 GB 70 cm Projection: 80 Surface mesh 08.10.2018 X rays see all 17

Analysis possibilities provided by CT data Obtained CT data are stored in form of 3D lattice of voxels that allows a wide range of analyses to be performed: 1. 2D Cross-sections 2. 3D Qualitative visualization 3. Separation of different parts in a sample - grey level value segmentation 4. Particle analysis (size, position and shape descriptors) 5. Weld assessment 6. Surface mesh extraction 7. Wall thickness 8. Advanced applications: classification, quality control, corrections for additive manufacturing settings, metrology measurements, FEM simulations based on CT data 08.10.2018 X rays see all 18

Software 08.10.2018 X rays see all 19

NDT Applications qualitative observations Copper micro Nozzle Beam hardening 3 cm 3D volume with clipping plane Voltage: 220 kv, Distance: 165 mm, Voxel size: 26 µm, Projections: 1750 Image avg.: 3 images Measurement time: 3 h 08.10.2018 X rays see all 20

NDT Applications qualitative observations 11 T magnet coil 80 cm 3D volume side view Voltage: 225 kv, Distance: 470 mm, Voxel size: 70 µm, Projections: 3000, Measurement time: 2 h 08.10.2018 X rays see all 21

NDT Applications qualitative observations 1.5 cm Connector in cryogenic instrumentation for LHC Voltage: 220 kv, Distance: 90 mm, Voxel size: 15 µm, Projections: 2050, Measurement time: 2.5h 08.10.2018 X rays see all 22

NDT Applications electronics Electronic component for ATLAS Forward Proton Detector Shorts ground-high voltage cable due to air bubbles found inside ATLAS Chip Aim: to understand issues related with IC packaging problem 1 cm 2.5 cm Voltage: 220 kv, Scan time: 1 h 10 min, Voxel size: 23 µm 3D volume and Top View cross-section Voltage: 215 kv, Distance: 55 mm, Voxel size: 9.64 µm, Projections: 2050, Integration time: 2 s, Measurement time: 2.5 h 08.10.2018 X rays see all 23

NDT Applications Porosity/Inclusion analysis Inclusion analysis for Mo-Gr samples Porosity in brazed layers of NA62 connector 1.5 cm 08.10.2018 X rays see all 24

NDT Applications Porosity analysis Test piece Filling Conformity with Unrolled brazing surface identification % EN ISO 18279 quality level C 1 >90% YES 2 >95% YES 3 >90% YES Copper brazed with steel 4 >90% YES 5 >85% YES 6 90% YES 2.5 cm brazed connections for R2E-LHC 08.10.2018 X rays see all 25

NDT Applications Wall thickness analysis Analysis of wall thickness of ALICE aluminium tubular segments 90 cm 08.10.2018 X rays see all 26

NDT Applications quantitative observations PCB with socket Aim: to understand issues related with loosen connection between socket and plug Voltage: 220 kv, Distance: 150 mm, Voxel size: 23 µm, Projections: 2050, Integration time: 2000 ms, Measurement time: 2.5 h Comparison: bad vs good socket 08.10.2018 X rays see all 27

NDT Applications quantitative observations CLIC Spiral Load Voltage: 220 kv, Distance: 750 mm, Voxel size: 111 µm, Projections: 2050, Integration time: 1000 ms, Measurement time: 1.5 h Surface rendering 08.10.2018 X rays see all 28

Metrology Applications 1 Importation of tomographic data on Calypso 2 Preparation measurement program 3 Use of specific Calypso algorithms such as Curve, Freeform for surface measurements of Freeform shapes (impossible on VG Studio) 4 Same program than CMM: possibility to pass from CT to CMM for the same part 08.10.2018 X rays see all 29

Metrology Applications CLIC Spiral Load Nominal-Actual Comparison 08.10.2018 X rays see all 30

Applications - metrology Titanium printed spring with Zirconia sphere Aim: Metrology measurements in order to quantify sphericity and roundness of the interface between sphere and spring 0.5 cm Projection: 90 2D cross-section Voltage: 215 kv, Distance: 55 mm, Voxel size: 9.64 µm, Projections: 1600 Image avg.: off, Integration time: 2000 ms, Measurement time: 1 h 3D volume with clipping plane 08.10.2018 X rays see all 31

Applications - metrology Titanium printed serpentine Aim: Metrology measurements for machining purpose estimation of thickness to be removed 3 scans merged Voltage: 215 kv, Distance: 186 mm, Voxel size: 28.64 µm, Measurement time: 4 h 12 cm 3D volume with clipping plane 08.10.2018 X rays see all 32

Voxel size (Resolution) What is the voxel size for my sample? It depends on: 1. magnification (x position) / sample size 2. beam intensity / Image Contrast / Image Quality focal spot size (micro focus nano focus X-ray tube) beam filtration 3. sample orientation acquisition time and data size resolution vs detectability 08.10.2018 X rays see all 33

1. Magnification / voxel size Tube/piece/detector distances magnification M = D/x Object A cube defined by W x W x W is considered 410 Top View X - ray tube x W Detector D = 1375 mm W = 2048 * voxel_size (assuming that detector area is fully filled in by object projection) W / x = 410 mm / D (from Thales relation) voxel_size [µm] = 410/1375 * x [µm] /2048 = 0.145 * x [mm] 08.10.2018 X rays see all 34

1. Magnification voxel size vs sample size Distance [mm] 50 70 140 280 550 700 Voxel size [µm] 7 10 20 40 80 100 W [mm] ( Sample size ) 14 20 40 80 160 200 Magnification 28 20 10 5 2.5 2 But this is the best case. In practice sample is not perfectly aligned with detector center/plane. Also, because of maximum thickness to be passed through by X-rays (tilted orientation). Hence, it has to be placed further away from the X-ray tube in order to decrease magnification (fit inside projection frame) 08.10.2018 X rays see all 35

2. Influence of focal spot size Point Source Small Focal Spot Large Focal Spot Object Image Detector penumbra Focal spot size has to be adjusted in respect to object size in order to avoid blurred projections 08.10.2018 X rays see all 36

2. Effect of focal spot size blurred projections 08.10.2018 X rays see all 37

2. Spot size blurred projections Spot size = 90 µm Current = 500 µa Voltage = 180 kv Magnification = 65 08.10.2018 X rays see all 38

2. Spot size blurred projections Spot size = 36 µm Current = 200 µa Voltage = 180 kv Magnification = 65 08.10.2018 X rays see all 39

2. Spot size sharp projections Spot size = 7 µm Current = 50 µa Voltage = 180 kv Magnification = 65 08.10.2018 X rays see all 40

2. Spot size reconstructed thin tungsten wire voxel size 9.3 µm Spot size = 7 µm Spot size = 46 µm 08.10.2018 X rays see all 41

3. Beam intensity why beam has to be filtered? Beam hardening (BH) artefact Main reason of BH Uncorrected BH Corrected BH 08.10.2018 X-rays see all 42

3. Beam intensity why beam has to be filtered? Theoretical energy spectra for 420-kV X-ray source with tungsten target, calculated combining 5-keV intervals. Spectra consist of continuous Bremsstrahlung and characteristic K-series peaks at 57 59 and 67 69 kev. R.A. Ketcham, W.D. Carlson / Computers & Geosciences 27 (2001) 381 400 08.10.2018 X-rays see all 43

3. Beam intensity Filtering of Energy distribution No filter, 220 kv, 400 µa, spot size = 88 µm Cu = 2 mm, 220 kv, 400 µa, spot size = 88 µm No filter, 180 kv, 490 µa, spot size = 88 µm Cu = 2 mm, 180 kv, 490 µa, spot size = 88 µm 08.10.2018 X rays see all 44

3. Beam intensity how it can be increased We take advantage of detector capabilities in order to increase signal registered Solution Consequence Longer integration time => Longer acquisition Higher gain (signal amplification) => increased noise Binning 2 x 2 => reduced CT voxel size (increased detector pixel size, 1024 x 1024 px instead of 2048 x 2048 px) 08.10.2018 X rays see all 45

3. Beam intensity [Gain = 16, Integration time = 2 s] Cu = 2.5 mm, 220 kv, 488 µa, spot size = 70 µa Cu = 2.5 mm, 220 kv, 45 µa, spot size = 7 µa Contrast = Max Intensity Min Intensity 08.10.2018 X rays see all 46

4. Sample orientation Feldkamp reconstruction artefact electronic components in power amplifiers for LIU-SPS project 08.10.2018 X rays see all 47

Sample orientation Feldkamp reconstruction artefact 08.10.2018 X rays see all 48

Sample orientation Feldkamp reconstruction artefact 08.10.2018 X rays see all 49

4. Sample orientation Feldkamp reconstruction artefact 08.10.2018 X rays see all 50

Developed Applications Pore segmentation algorithms Several image processing methods were developed in order to estimate porosity of brazing Final result Standard approach Developed algorithm 08.10.2018 X rays see all 51

Developed Applications CT vs Ultrasound inspection A method was developed in order to compare porosity estimation obtained from µct measurements and ultrasound inspection Voltage: 215 kv, Distance: 90 mm, Voxel size: 15 µm, Projections: 1600, Measurement time: 2 h Defects found by UT (red areas on the left) and CT (dark areas on the right) 08.10.2018 X rays see all 52

Developed Applications X-ray radioscopy Sphere diameter < 20 µm! Chip0FF - 1840 Chip1FF - 1840 Chip2FF - 1840 Chip3FF - 1840 Chip4FF - 1840 Chip5FF - 1840 Chip6FF - 1840 Chip7FF - 1840 Chip8FF - 1840 Chip9FF - 1840 08.10.2018 X rays see all 53

Developed Applications X-ray radioscopy A Flat Field algorithm was developed at CERN in order to perform manual X-ray radioscopy using Zeiss Metrotom CT standard scan mode imposes sample rotation which limits resolution in the case of a flat sample. Corrected Image = (Raw_Projection Dark_Frame)/(Bright_Frame Dark_Frame) RAW projection Bright Frame (Gain) Dark Frame (no beam) Corrected projection 08.10.2018 X rays see all 54

Developed Applications X-ray radioscopy Width = 15 cm 08.10.2018 X rays see all 55

Summary 1. NDT New possibilities to analyse quantitatively and qualitatively internal structure of materials 2. METROLOGY Complementary to CMM and other measurement means Good accuracy for many parts 3. Custom Algorithms and image processing methods were developed. One of them will be presented at the ict Conference 2019 in Padova 08.10.2018 X rays see all 56

Thank you for your attention!

Developed Applications Pore segmentation algorithms Several image processing methods were developed in order to estimate porosity of brazing Standard threshold CLAHE Noise reduction Auto local threshold Binary cleaning Final result 08.10.2018 X rays see all 58

Applications - metrology Titanium sample 3D printed and polished (designed for crab cavity) Aim: 1. Comparison of 3D printed sample with CAD model used for printing. Voltage: 220 kv 2. Estimation of surface thickness removed during following polishing Distance: 755 mm Voxel size: 112 µm Projections: 2200 Image avg.: 3 images Integration time: 1 s Measurement time: 2 h Projection: 90 3D volume with clipping plane Nominal/actual comparison with CAD model 08.10.2018 X rays see all 59