Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous area: SiC plug, 0-pin Function s are made to carry isolated barriers and provide terminal connection for wiring. The termination board and the isolated barriers build the connection between field and system level. System connectors are syntonized to the requirements of the I/O cards used in the particular automation system. They ensure fast and fail-safe connection. Information about missing supply voltage of the interface modules is available for the system as potential free relay contact. Wiring errors from field will be reported if the interface module supports this function. The s are supplied with a robust glass fibre reinforced plastic housing as standard. This design permits the fast and reliable installation in the switch cabinet. Connection 3 Zone 0,, Div., 3 3 TB TB 4 5 6 7 8 9 0 3 4 5 6 X X5 TB3 TB4 SAI-60m 4 V DC (I), 4 V DC (II) Fault HART USA: + 330 486 000 Germany: +49 6 776 Singapore: +65 6779 909
Connection terminal block TB3 (-, +; 3-, 4+) Nominal voltage 4 V DC, in consideration of rated voltage of used isolators Voltage drop 0.9 V, voltage drop across the series diode on the termination board must be considered Ripple 0 % Fusing 4 A Power dissipation 500 mw, without modules Reverse polarity protection yes Redundancy Redundancy available. The supply for the isolators is decoupled, monitored and fused. Fault indication output Output type Contact loading Indicators/settings Display elements volt-free contact 30 V DC, A LEDs PWR ON (power supply) - LED power supply I, green LED - LED power supply II, green LED LED Fault (fault indication), green LED Directive conformity Electromagnetic compatibility Directive 04/30/EU EN 636-:03 (industrial locations) Conformity Electromagnetic compatibility NE :07 For further information see system description. Degree of protection IEC 6059:00 Ambient conditions Ambient temperature -0... 60 C (-4... 40 F) Storage temperature -40... 70 C (-40... 58 F) Mechanical specifications Degree of protection IP0 Connection Field side explosion hazardous area: pluggable screw terminals, blue Control side non-explosion hazardous area: SiC plug, 0-pin pluggable screw terminals, black Fault output pluggable screw terminals, black Core cross-section screw terminals: 0.5....5 mm (4... AWG) Material housing: polycarbonate Mass approx. 85 g Dimensions 73 x 55 x 53 mm (L x W x H), height including module assembly Mounting on 35 mm DIN mounting rail acc. to EN 6075:00 Data for application in connection with hazardous areas EU-Type Examination Certificate CESI 06 ATEX 0 Marking II ()G [Ex ia Ga] IIC II ()D [Ex ia Da] IIIC I (M) [Ex ia Ma] I Non-hazardous area Maximum safe voltage 50 V (Attention! U m is no rated voltage.) Galvanic isolation Field circuit/control circuit safe electrical isolation acc. to IEC/EN 60079-, voltage peak value 375 V Directive conformity Directive 04/34/EU EN 60079-0:0+A:03, EN 60079-:0, EN 50303:000 International approvals UL approval Control drawing 6-037 IECEx approval IECEx certificate IECEx CES 06.0003 IECEx marking [Ex ia Ga] IIC [Ex ia Da] IIIC [Ex ia Ma] I General information Supplementary information Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. Accessories USA: + 330 486 000 Germany: +49 6 776 Singapore: +65 6779 909
Designation provided accessory: Label Carrier HiALC-HI*TF-SET-** optional accessories: - HART communication board HiATB0-HART-X6 - HART multiplexer master HiDMux700 - HART connection cable HiACA-UNI-FLK34-*M* USA: + 330 486 000 Germany: +49 6 776 Singapore: +65 6779 909 3
Pin-out Table Module Channel IS Terminal TB IS terminals SL 3 3 4 4 5 5 6 6 7 7 8 8 5a 5b 3 a 4 b 5 5a 6 5b 7 a 8 b 9 5a 0 5b a b 3 5a 4 5b 5 a 6 b 7 5a 8 5b 9 a 0 b 5a 5b 3 a 4 b 5 5a 6 5b 7 a 8 b 9 5a 30 5b 3 a 3 b Modules Non-IS terminals SL System connector X A9 B9 A8 B8 A7 B7 A6 B6 USA: + 330 486 000 Germany: +49 6 776 Singapore: +65 6779 909 4
Pin-out Table Module Channel IS Terminal TB IS terminals SL 9 9 0 0 3 3 4 4 5 5 6 6 5a 5b 3 a 4 b 5 5a 6 5b 7 a 8 b 9 5a 0 5b a b 3 5a 4 5b 5 a 6 b 7 5a 8 5b 9 a 0 b 5a 5b 3 a 4 b 5 5a 6 5b 7 a 8 b 9 5a 30 5b 3 a 3 b Modules Non-IS terminals SL System connector X A5 B5 A4 B4 A3 B3 A B pin out Power supply Volt-free fault indication output TB3 TB4 Module pin-out (SL): module... 6 a V cc b FAULT a b 6b I - I + 3 II - 4 II + Fault USA: + 330 486 000 Germany: +49 6 776 Singapore: +65 6779 909 5