This document contains the firmware release notes for two models. The SDS1202X-E is a dual channel 200 MHz scope.

Similar documents
firmware scope. MHz options. 1 / 6

R&S RTB2000 Oscilloscope Release Notes Firmware Version

WaveAce Series Oscilloscopes

WaveAce Oscilloscopes 40 MHz 300 MHz. Debug With Confidence

WaveAce Oscilloscopes 40 MHz 200 MHz. Debug With Confidence

Worldwide First. Tablet Oscilloscope. New Generation Oscilloscope. tbook series. Tablet Oscilloscope Innovator. Memory. Sampling. Bandwidth.

Fluke 190-Series II Firmware Upgrade V11.46

DSO3062A Oscilloscope, 60 MHz

GFT6084 Quad 2 / 4GS Digitizer

USB Instruments EasyScope II for PS40M10 "Swordfish" Help

PCI Express Signal Quality Test Methodology

TBS2000 Oscilloscope Demo Guide 28 JULY 2016

Digital Storage Oscilloscope

Keysight U1602B and U1604B Handheld Digital Oscilloscopes

R&S RTO and R&S RTE Oscilloscopes Release Notes Firmware Version

The Next Generation of Portable Oscilloscope

1000 Series Portable Oscilloscopes

Digital Storage Oscilloscope

Step 1. Overview. Goal. System Requirements - 1 x WaveAce passive probe. Setup

Peregrine Technology CO.,LTD. DSO Oscilloscope. User Menu. V1.1 Date: 2014/07/11

Compact 8 in 1 Multi-Instruments SF Series

Agilent Technologies 6000L Series Low-Profile Oscilloscopes. The most space efficient LXI C compliant oscilloscopes. Four channels in only 1U space

EasyScopeIII for DS60M10. User Guide

DLM2000 Series. Mixed Signal Oscilloscope. IM E 3rd Edition

DS2200C User Manual Copyright (c) EasySync Ltd. 2003

GDS-2000 Series. Features

Manual imso-204x. RevOrig_

Digital Storage Oscilloscope

Digital Storage Oscilloscope

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Service Guide. Publication Number March Agilent Technologies, Inc Infiniium A-Series Oscilloscopes

Infiniium X / L- Series Oscilloscopes

Keysight M8070A System Software for M8000 Series of BER Test Solutions

Infiniium Q- Series Oscilloscopes

DSO1000A/B Series Portable Oscilloscopes

MicroBench MB-500A. Live Logic Logic source pattern generator Logic analyzer Arbitrary waveform generator Protocol interactive test

Parallel and Serial Bus Analysis Instructor s Guide

Keysight Infiniium 9000 Series Oscilloscopes

Copyright ANRITSU. All rights reserved.

JitKit. Operator's Manual

Quick Reference Guide WaveRunner Xi-A and MXi-A Oscilloscopes

DSO NANO v3 MANUAL.

Quick Reference Guide WaveRunner 6 Zi Oscilloscopes

LDR_Light_Switch1 -- Overview

DL7200 Digital Oscilloscope CAN Bus Signal Analysis Function

CellAdvisor TM JD720C Cable and Antenna Release Notes for Version

4 Introduction to the Controls

Release Notes. R&S FSC Spectrum Analyzer

PS40M10 SwordFish Multi-Function Instrument. Getting Started Guide

Digital Storage Oscilloscope

Software Release Notes

20 WAVEFORM STORE & RECALL

Agilent Technologies InfiniiVision 6000L Series Low-Profile Oscilloscopes

New Functions and Options in the current Release of SATlive

GDS-2000E Series DSO New Product Announcement

Exploring the Custom Analysis Interface for use with MATLAB on Tektronix Oscilloscopes

LDR_Light_Switch2 -- Overview

User s Guide DSO-5200 USB PC Based Digital Oscilloscope Operation Manual

The uscope Getting started

Devices currently supported are: Fluke 43x-I V02.10 Fluke 1735 V01.10 Fluke VR 1710 V1.31

Fluke 1750 Power Analyze

Keysight Infiniium Oscilloscopes Software

CAN, LIN and FlexRay Protocol Triggering and Decode for Infiniium Series Oscilloscopes

Reference. Menu Overview. Functions Common to Generator (TX) and Analyzer (RX) AC Power. Selecting 115 VAC or 230 VAC Operation

VIRTUAL PANEL, FUNCTION GENERATOR, OUTPUT DATA LOGGER USER MANUAL FOR Z+ SERIES POWER SUPPLIES

Prisma Public Manifest


2019 RIGOL (SUZHOU) TECHNOLOGIES INC.

QPHY-PCIE (Gen1 and Gen2) Operator s Manual

S2 Family Reversing 2-port VNAs of Planar, S, and Cobalt Series

UNIVERSITY OF CALIFORNIA BERKELEY Department of Electrical Engineering and Computer Sciences. B. E. BOSER Oscilloscopes EECS 100

GL900 USER S MANUAL MANUAL NO. APS(GL900-4/8)-UM-151

New Features in Firmware V2.02 (Compared to V2.01) New Features in Firmware V2.01 (Compared to V2.00)

Manual imso-204 imso-204l

Agilent Technologies 1000 Series Portable Oscilloscopes

MotionDAS. MotionPro DAS User Manual (For Windows ) User Manual 1

Agilent Technologies 1680/90-Series Logic Analyzer. Service Guide. Publication number October 2005

SR3_Analog_32. User s Manual

99 Washington Street Melrose, MA Phone Toll Free Visit us at

Help Volume Hewlett Packard Company. All rights reserved. Toolsets: IA Format Utility

PCI Express (Rev1.1) Test Methodologies Data Signal Quality; Reference Clock Jitter

Fluke Energy Analyze Release Information

GL500A Application Manual

Keysight U1610/20A Handheld Digital Oscilloscope. Quick Start Guide

TDSPTD Protocol Trigger and Decode Application Online Help

Digitakt OS 1.07 Release Information

USB Instruments EasyLogger for PS40M10 "Swordfish" Help

HP Series Oscilloscopes Analog feel and digital power for precise, accurate troubleshooting at an affordable price

Cal-Bay Systems XY Plotter, Time-Base Recorder, Automated Tester. Users Guide. Rev 3.1

PCI Express Protocol Triggering and Decode for Infiniium 9000 Series Oscilloscopes

D02 Release... 4 Overview... 4 Critical fixes... 4 Enhancements... 4 Non-critical fixes... 4 D01 Release... 4

PCI-express data acquisition card DAQ0504M User Guide

How to Operate the DDA Remotely

User Manual. HEDS-8949 & HEDS-8969 Alignment Kit for AEAT-9000 Encoders. 1. Introduction. Overview. Features. Ordering Information

I 2 C and SPI Protocol Triggering and Decode for Infiniium 8000 and Series Oscilloscopes

I 2 C and SPI Protocol Triggering and Decode for Infiniium 9000 Series Oscilloscopes

MIZ-21C Software Product Bulletin

MAXSANTAFEEVSYS User Manual

Agilent 53210A 350 MHz RF Counter Agilent 53220A 350 MHz Universal Frequency Counter/Timer Agilent 53230A 350 MHz Universal Frequency Counter/Timer

CATALOGUE. SmartDS Series. MSO Series. Xiamen Lilliput Technology Co.,Ltd. NEW! 10M Deep Memory. Main Features:

Transcription:

This document contains the firmware release notes for two models of SIGLENT SDS1000X-E oscilloscopes. The SDS1202X-E is a dual channel 200 MHz scope. The SDS1004X-E is a four channel scope available in 100 and 200 MHz options. The firmware is specific for a particular model. The 2 channel firmware will not work with the 4 channel scope and vice versa. The release notes document is for reference only. The official release notes are located in the zipped folder that contains the actual firmware download. Release Notes of the SDS1002X-E Follow 1 / 8

Revision History 2018/9/20 1.3.23 1. Changed the displayed system information screen. From ADS version of 1.3.23, the info screen now shows 5 sections of software versions, including the OS version ID. 2. Added SCPI commands for Math waveforms (except FFT). 3. Optimized accuracy of horizontal measurement, especially when there are only a few samples in very small timebase. 4. Added ability to disable one direction of the full duplex encoders. 5. Any arbitrary probe factor from 1e-6 to 1e6 can be set by universal knob. 6. Attenuation and invert indicator were added into the channel tab. 7. There are some times of quick calibration during warming up the SDS XE. Added a menu below Utility to disable the quick calibration so that the sampling can t be interrupted. 8. Added SCPI to set up gated measurements on an SDS XE scope and return the data. 9. Supported exiting the on-screen keyboard by OK button. 10. Fixed the bug related to displaying long IC2 decoded packets. 11. Fixed the channel inversion bug when changing timebase from 1ms to 2ms 12. Fixed the bug: The setting of Educational mode can t be saved after power off. 13. Fixed the bug: I2C address to 0x3F and the fist byte to 0x8C - trigger does not work 14. Fixed the bug: The I2C trigger condition "7 bit Address&Data" does not work when the payload contains only a single byte. 15. Fixed the bug: Looks like SDS1202X-E does not discard incomplete bytes in the payload although they are easily detectable. 16. Optimized decoded data of I2C and got rid of suffix H and A. 17. Fixed the bug: There is offset with Channel coupling of GND. 18. Fixed the bug of failing to save Pass/Fail mask to U disk. 19. Fixed the bug: Save data as CSV, but the data does not account for the vertical offset of the data. 20. Fixed the bug: The binary block returned by the WAVEFORM command contains the length of the block in the #9 header. This length is incorrect when the NP option of the WFSU command is used; the header then gives the memory depth instead of the actual size of the block. 2 / 8

21. Fixed the bug of response from the WAVEFORM command prefixes the binary block with the string "ALL," even when "CHDR OFF" is used. 22. Optimize self-calibration for channels. 2018/1/27 5.1.3.17R1 1. Fixed bug: Sometimes Auto setup fails on probe compensation output. 2017/11/20 5.1.3.17 1. Fixed bug: Corrected under-compensation from probe compensation waveform on 100 mv/div ranges. 2. Fixed bug: FFT horizontal frequency div is incorrect. The wrong sequence is shown: 5 Hz, 2 Hz, 1 Hz, 2 Hz, 5 Hz, 100 mhz, 200 mhz. 3. Optimized translation for German and English menus and pop-up messages. 4. Fixed bug: The scope does not save the limit range of slope trigger while powered off. 5. Fixed bug: The waveform disappears from the Zoom window at the edge of screen with the timebase set to 500ns/div. 6. Fixed bug: There is an issue with the Y cursor offset/scaling, probe with x10 setting. The Y1/Y2 cursor values do not match the Y voltage division/offset of the selected input channel. 7. Fixed bug: Track cursor source set to track the waveform in the zoom window, but it tracks main window. 2017/7/06 5.1.3.13 1. Cursor values not correct if probe attenuation was not set to 1X. 2. Removed channel input impedance of 50Ω. 3. Added extern load setting to FFT menu. If using an external load, amplitudes can be shown in dbm. 4. Repaired intermittent lock up after enabling decoding function. 5. Optimized translation for German and English menus and pop messages. 6. Removed Option label from UI. 7. Corrected cursor measurements for active Zoom with FFT. 8. Added telnet(port 5024) and open socket(port 5025) for LAN communication. 9. Fixed blank zoom bug. With both channels at 2 ms/div, 7 Mpts, and a zoom of 500 ns/div, the zoom window would blank. 10. Fixed decode threshold levels for 10X probe attenuation selection. 11. Fixed average mode. After pressing [Run/Stop] to halt acquisition, the display changed to the last waveform, rather 3 / 8

than maintaining the averaged waveform. 12. Remain the final message for firmware update until rebooted. 13. Fixed the issue with Chinese language setting after selfcalibration. 14. Fixed the CAN source bug. If the source selected was CANH or CANL, decode would not work correctly. 15. Decreased waveform jitter with active measurements or math with horizontal delay out of the screen. 16. Added progress information while saving CSV files. 17. Fixed the Cycle RMS measurement does not update when the input signal changes. 18. Keep Print picture type in accordance with the type selected from Save/Recall. 19. Fixed user file renaming of a previously saved file. 20. Enabled decoding for time bases above 20ms/div. 21. Disable menu if cursors, measurement and math is disabled. 22. Finished updates to support EasyScopeX and Labview driver. 23. Optimized channel self-calibration. 2017/3/22 5.1.3.8 1. Initial formal release. Compatibility between Versions Source Version Object Version Compatibility 4 / 8

This document contains the firmware release notes for two models of SIGLENT SDS1000X-E oscilloscopes. The SDS1202X-E is a dual channel 200 MHz scope. The SDS1004X-E is a four channel scope available in 100 and 200 MHz options. The firmware is specific for a particular model. The 2 channel firmware will not work with the 4 channel scope and vice versa. The release notes document is for reference only. The official release notes are located in the zipped folder that contains the actual firmware download. Release Notes of the SDS1004X-E Follow 5 / 8

2018/09/20 6.1.26 1. Added SCPI command to set up gated measurements and return the data. 2. Customers can save the result of decode list table to a CSV file. 3. Modified the color of FFT to match the trace selected. 4. There are some times of quick calibration during warming up the SDS XE. Added a menu below Utility to disable the quick calibration so that the sampling isn t interrupted. 5. Created software that converts binary waveform data to CSV. It can be downloaded from the embedded web server on the scope. 6. Fixed the bug: Screen Save button on web page does not work with some browsers. 7. Fixed the bug: The setting of Educational mode can t be saved after power off. 8. Fixed a bug with MSO decoding. and the SLA1016 firmware also needs to be updated to 8.1.11. 9. Fixed the bug: The binary block returned by the WAVEFORM command contains the length of the block in the #9 header. This length is incorrect when the NP option of the WFSU command is used; the header then gives the memory depth instead of the actual size of the block. 10. Fixed the bug of the scope response from the WAVEFORM command prefixes the binary block with the string "ALL," even when "CHDR OFF" is used. 11. Added exiting the on-screen keyboard by OK button. 2018/05/31 6.1.25R2 1. Fixed the bug: Once the acquisition is stopped, the scope often can't find search events in other channels. 2. Fixed the bug: In certain situations, the scope freezes when the Auto Setup button is pressed. 3. Fixed the bug: The Pass/Fail mask is not correct at edge of screen left and right. 4. Attenuation and invert indicator were added into the channel tab. 5. Any arbitrary probe factor from 1e-6 to 1e6 can be set by universal knob. 6. Got rid of suffix 'A' that stands for 'Acknowledge' from I2C decode. 7. Fixed the bug: The dedicated window for long I2C data sometime lose data at right edge. 8. Fixed the bug: The decoder sometimes does not show any 6 / 8

info. 9. Fixed the bug: After updating to the last firmware and OS version, the remote panel/control interface can no longer be connected. 2018/05/02 6.1.25R1 1. Increased XY mode wave fresh speed. 2. Changed the displayed system information screen. From ADS version of 6.1.25R1, the info screen now shows 5 sections of software versions, including the OS version ID. 3. Optimized remote webpage screen update rate. Requires both OS and ADS update which are located on the SIGLENT product webpage. 4. Add virtual control panel for PC and mobile terminals. 5. Added SCPI commands for Math waveforms (except FFT) and digital channel waveforms (ADS version of SLA1016 should be > 8.1.9). 6. See the SIGLENT product webpage for software updates. 7. Added Digital Channel cursor support. 8. Optimized accuracy of horizontal measurement, especially when there are only a few samples in very small timebase. 9. The Link to Trigger menu modified to Copy setting. 10. Added ability to disable one direction of the full duplex encoders. 11. Fixed the bug related to displaying long IC2 decoded packets. 12. Fixed the bug: SDS1004X-E webpage update would sometimes fail. 13. Fixed the channel inversion bug when changing timebase from 1ms to 2ms. 14. Fixed the bug: Unreadable digital system information. 2018/02/27 6.1.20R1 1. Added Bode Plot support for all of Siglent s SDG instruments. 2. Fixed a bug in 6.1.20 which maybe cause signal disappear after self-calibration for Channel. 2018/02/01 6.1.20 1. Add MSO/Logic functionality. 2. Added automatic vertical scale (volts/div) in Bode Plot mode. 3. Added USB WiFi support. 4. Optimized the WiFi GUI. 5. Automatic Roll mode selection will be disabled if manually disabled once. 6. Renamed Runt-Trigger in German. 7. Fixed a bug in the I2C triggering system of 7 bit Address& Data. 8. Improved Auto Setup function with1k compensation output. 9. Improved waveform update when using sequence mode on 7 / 8

long timebases. 10. Optimize self-calibration for channels. 2017/12/18 6.1.12R1 1. Modified Pass/Fail output pulse to 5us. 2017/11/16 6.1.12 1. Initial formal release of SDS1004X-E. Compatibility between Versions Source Version Object Compatibility Version 6.1.25R1 6.1.25R2 Yes 6.1.20R1 6.1.25R2 Yes 6.1.20 6.1.25R2 Yes 6.1.12R1 6.1.25R2 Yes 6.1.12 6.1.25R2 Yes Update instructions Very important! Because 6.1.20R1 fixed a bug with self- calibration for the each channel, the oscilloscope will need to perform a self-calibration once if the machine is updated to 6.1.20R1(or higher). 8 / 8