MANUAL LML-P, LML-S, LML-Ex

Similar documents
PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

MANUAL Surge Protectors

MANUAL Functional Safety

PROCESS AUTOMATION INSTRUCTION MANUAL FIELDBUS SURGE PROTECTOR F*-LBF-I1.32 F*-LBF-D1.32

MANUAL Functional Safety

FACTORY AUTOMATION MANUAL ODZ-MAH-B15-M3

FACTORY AUTOMATION. MANUAL OHV-F230-B17 PROFINET Gateway for OHV Handheld

MANUAL Vibracon LVL-A7

MANUAL Functional Safety

MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

FACTORY AUTOMATION MANUAL PMI360DV-F130-IU2E2- V15

FACTORY AUTOMATION. MANUAL VAA-2E-G4-SE Original Instructions Version 1.1

PROCESS AUTOMATION MANUAL. Temperature Trip Amplifier. KFD2-GU-(Ex)1 ISO9001

PTB 01 ATEX Example / Beispiel / Exemple. Type Operating Instructions

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

MANUAL Installation and Configuration

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Control unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V

SMARTLINE RM76 Supplementary instructions

MANUAL Functional Safety

Operating manual. Series 450. Compact thermometer. BA01235O/09/en/

PI-EX-ME-2NAM/COC-24VDC

TECHNICAL INFORMATION Vibracon LVL-B1, LVL-B2

Float switch For industrial applications Model RLS-1000

PI-EX-ME-2NAM/COC-120VAC

Operating instructions. Switching amplifier DN0210 DN / / 2015

DR7100 SERIES Supplementary instructions

PHOENIX CONTACT - 12/2007

FACTORY AUTOMATION. MANUAL Absolute Rotary Encoder with PROFIBUS Interface

Vibration Sensor Type 640

PHOENIX CONTACT - 01/2008

Operating instructions Safety-monitoring module AES 1102 AES About this document. Content. 8 Appendix 8.1 Wiring examples...

MANUAL HART Multiplexer System

Operating instructions. Speed monitor D / / 2014

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

FACTORY AUTOMATION QUICK START GUIDE IC-KP-*

MANUAL MODULAR SEGMENT PROTECTOR

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

PROCESS AUTOMATION. MANUAL H-System. Isolated Barriers and Termination Boards ISO9001

FACTORY AUTOMATION INSTRUCTION MANUAL. AS-Interface Safety at Work VAA-2E-G4-SN. Version 1.2

Operating instructions. Standstill monitor A / / 2011

PTB 01 ATEX 2064 U, IECEx PTB U. Example / Beispiel / Exemple: Type Operating Instructions

PROCESS AUTOMATION MANUAL. Universal Temperature Converter KCD2-UT2-(Ex)1 ISO9001

PROCESS AUTOMATION MANUAL. Universal Transmitter Power Supply. KF**-CRG2-(Ex)1.D ISO9001

GRP Flameproof Visual Signal Xenon or Steady LED

PROCESS AUTOMATION MANUAL. HART Loop Converter KFD2-HLC-Ex1.D(.**) ISO9001

FACTORY AUTOMATION INSTRUCTION MANUAL INDUCTIVE POSITIONING SYSTEM -F90

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

QUICK START GUIDE IC-KP2-*

Control unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

SYSTEM DESCRIPTION H-System

Operating instructions Safety sensor BNS About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

SolConeX extra-low voltage flange socket

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Operating Instructions

BVS 17 ATEX E 117 X / IECEx BVS X Types 3320, 3321, 3323, 3360, 3361, 3363 AE3320, AE3321, AE3323, AE3360, AE3361, AE3363

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

MANUAL PCV Parameterization Tool

Pneumatic Control/Feedback

Operating instructions Safety-monitoring module AES 1235 AES About this document. Content

PHOENIX CONTACT - 05/2007

Operating Instructions Soliswitch FTE20

Operating instructions Hinge safety switch TV.S 335 TV.S About this document. Content

MANUAL FieldConnex Basic Segment Coupler

BVS 16 ATEX E 118 X / IECEx BVS X Types 8791, 8792, Additional Instructions. Zusatzanleitung Instruction supplémentaire

USER MANUAL VIBRATION CONTROL RMA-POWER-BOX 107/230

Keystone OM3 - EPI-2 Local Interface Module Installation and Maintenance Instructions

Inductive sensor NI3-EG08K-Y1-H1341

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Technical Data. General specifications. Output type Rated operating distance s n 8 mm

FACTORY AUTOMATION MANUAL WCS-MBG110 WCS MODBUS RTU INTERFACE MODULE

Pneumatic Control/Feedback

Original operating instructions Fail-safe inductive sensor GI711S / / 2010

Operating instructions Safety sensor BNS About this document. Content

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor with analog output BI15-M30-LI-EXI

TECHNICAL INFORMATION Vibracon LVL-A7

Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

FACTORY AUTOMATION. MANUAL VBA-4E3A-G20- ZEL/M1L-P2 AS-Interface Motor Control Module

FACTORY AUTOMATION. MANUAL IQT1-*-R4-V1 RFID R/W systems, MHz

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

Float Switches with Permanent Magnet For Vertical Installation Model RSM

SAFETY MANUAL SIL Switch Amplifier

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Installation instructions Inclination sensor EC2019 EC / / 2013

Product manual plug, sockets and coupler 16 A.- Z0251

Operating Instructions

Operating instructions Safety sensor EX-BNS40S. 1. About this document. Content

Operating instructions Door handle switch BNS-B About this document. Content. 6 Disassembly and disposal 6.1 Disassembly Disposal...

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

FACTORY AUTOMATION MANUAL VBP-HH1-V3.0-V1

Interface and Supply module. IPC 3x0i / PSC 3x0i

Polymer Electric. Operating Instructions. Control Unit SG-RST 153. Version 0.3

Inductive sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

Operating Instructions for Level Switch for Liquids. Model: RFS

Transcription:

PROCESS AUTOMATION MANUAL LML-P, LML-S, LML-Ex Magnetic Immersion Probe for Limit Value Detection ISO9001

With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services of the Electrical Industry, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.v.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship"

Content 1 Introduction..................................... 2 1.1 Contents............................................ 2 1.2 Target Group, Personnel............................... 3 1.3 Symbols Used........................................ 3 2 Product Specifications............................ 5 2.1 Function............................................. 5 2.2 Assembly............................................ 6 3 Goods Acceptance............................... 7 4 Mounting and Installation......................... 8 4.1 Checking the Device Function before Mounting........... 8 4.2 Mounting............................................ 9 4.3 Connection......................................... 11 5 Operation...................................... 14 5.1 Checking the Device Function......................... 14 6 Troubleshooting................................ 15 7 Maintenance................................... 16 8 Repair, Return, and Disposal..................... 17 9 Technical Specifications......................... 18 9.1 Technical Specifications.............................. 18 9.2 Dimensions......................................... 21-1

Introduction 1 Introduction 1.1 Contents This document contains information that you need in order to use your product throughout the applicable stages of the product life cycle. These can include the following: Product identification Delivery, transport, and storage Mounting and installation Commissioning and operation Maintenance and repair Troubleshooting Dismounting Disposal Note! This document does not substitute the instruction manual. Note! For full information on the product, refer to the instruction manual and further documentation on the Internet at www.pepperl-fuchs.com. The documentation consists of the following parts: Present document Instruction manual Datasheet Additionally, the following parts may belong to the documentation, if applicable: EC-type of examination EU declaration of conformity Attestation of conformity Certificates Control drawings Additional documents 2 -

Introduction 1.2 Target Group, Personnel Responsibility for planning, assembly, commissioning, operation, maintenance, and dismounting lies with the plant operator. Only appropriately trained and qualified personnel may carry out mounting, installation, commissioning, operation, maintenance, and dismounting of the product. The personnel must have read and understood the instruction manual and the further documentation. Prior to using the product make yourself familiar with it. Read the document carefully. 1.3 Symbols Used This document contains symbols for the identification of warning messages and of informative messages. Warning Messages You will find warning messages, whenever dangers may arise from your actions. It is mandatory that you observe these warning messages for your personal safety and in order to avoid property damage. Depending on the risk level, the warning messages are displayed in descending order as follows: Danger! This symbol indicates an imminent danger. Non-observance will result in personal injury or death. Warning! This symbol indicates a possible fault or danger. Non-observance may cause personal injury or serious property damage. Caution! This symbol indicates a possible fault. Non-observance could interrupt the device and any connected systems and plants, or result in their complete failure. - 3

Introduction Informative Symbols Note! This symbol brings important information to your attention. Action This symbol indicates a paragraph with instructions. You are prompted to perform an action or a sequence of actions. 4 -

Product Specifications 2 Product Specifications 2.1 Function The device is a sensor for limit detection in liquids. An integrated ring magnet in the float actuates the contacts on the inside of the probe tube via its magnetic field. If the float leaves the range of the switch contact, the switch contact reassumes its initial status. Using the set collars clipped onto the probe tube, switch points can be prevented from being skipped during rapid changes in fill level. A permanent contact is established in the same way. Magnetic immersion probe LML-P The device can have up to three floats. The maximum sliding tube length is 1000 mm. The sliding tube and process connection are made from plastic. Magnetic immersion probe LML-S The device can have up to three floats. The maximum sliding tube length is 3000 mm. The sliding tube and process connection are made from stainless steel. Magnetic immersion probe LML-Ex The device is intended for use in explosion-hazardous areas. The device can have up to three floats. The maximum sliding tube length is 3000 mm. The sliding tube and process connection are made from stainless steel. Note! For more information see the corresponding datasheets. - 5

Product Specifications 2.2 Assembly 1 2 3 4 5 6 7 Figure 2.1 1 Terminal box 2 Process connection, e. g. thread 3 Sliding tube 4 Float cylinder 5 Float ball 6 Drop protection ring of Teflon 7 Set collar 6 -

Goods Acceptance 3 Goods Acceptance Removing the Device from the Transport Packaging and Checking the Device 1. Remove the transport restraints. 2. Carefully remove the device from the shipping packaging. 3. Remove the packaging parts from the device. 4. Check that the order designations on the delivery note and nameplate are identical. 5. Check to ensure the device is not damaged. 6. Check that the float can be easily moved along the sliding tube. Note! If any of these conditions are not met, contact your Pepperl+Fuchs distribution center. - 7

Mounting and Installation 4 Mounting and Installation 4.1 Checking the Device Function before Mounting You have the option of testing the device before it is mounted in the container. To do this, use an ohmmeter. Checking the Device Function 1. Connect the conductors of the switch point to be tested to the ohmmeter. 2. Lift the float and move it towards the switch point. Depending on the switching function, continuity or no continuity is signaled. 3. Move the float back to its starting position. The switching function must be reversed. 4. Repeat steps 1 to 3 for each switch point. Figure 4.1 Example: functional test of the device with two switching points L2 L1 Note! The switching point dimensions L1 and L2 refer to the respective measurements from the sealing surface to the center of the float. 8 -

Mounting and Installation 4.2 Mounting Danger! Danger to life from working in containers In containers, hazardous substances may be present that can result in poisoning or suffocation. Eliminate or reduce hazardous substances. Protect persons that come in contact with hazardous substances by means of suitable protective measures, e. g., by respiratory devices or protective clothing. Danger! Explosion hazard from sparking when using the device Improper use of the device in a potentially explosive atmosphere can cause sparks that can ignite the surrounding atmosphere. Do not remove the drop protection rings. Drop protection rings of teflon prevent sparking on impact of the float on the set collar. Operating the device without drop protection rings is prohibited. If you are using floats of titanium: Keep the maximum permissible ambient temperature by ensuring a sufficient distance between the process connection and the medium. Mounting the Device 1. Observe the safety information given in the instruction manual. 2. Prior to installation, ensure that the installation opening on the container and the securing device on the float match in terms of size and dimensioning. 3. Install the device in the container from the outside. The device is installed in a vertical position. The angle of installation must not deviate from the vertical position by more than 30, see Figure 4.2. 4. Screw in the device using the full length of the thread (1). Use suitable seals. For variants with floats fitted that are larger in diameter than the core diameter of the installation opening, proceed as follows. - 9

Mounting and Installation Mounting the Device 1. Mark the top of the float (4) (e. g. with "top"). 2. Mark the position of the set collars to be removed (6). 3. Remove the set collars (6) and drop protection rings (5). 4. Remove the float (4). 5. Install the device. 6. Install the float (4), set collars (6) and drop protection rings (5) from inside the container. Pay attention to the markings. 1 2 3 4 5 6 max. 30 Figure 4.2 Principal device mounting 1 Process connection 2 Container 3 Sliding tube 4 Float 5 Drop protection ring 6 Set collar Note! Further information can be found in the chapter "Dimensions", see chapter 9.2. 10 -

Mounting and Installation 4.3 Connection Danger! Danger to life from electric shock Working on live parts at voltages higher than 50 V AC or 120 V DC can result in electric shock. 1. De-energize the device. 2. Secure the circuit against reconnection. 3. Verify that the device is de-energized at all poles. 4. Provide protection from adjacent live parts, if present. Danger! Danger to life from incorrect installation Incorrect installation of cables and connection lines can compromise the function and the electrical safety of the device. Observe the permissible core cross-section of the conductor. When using stranded conductors, crimp wire end ferrules on the conductor ends. Use only one conductor per terminal. When installing the conductors the insulation must reach up to the terminal. Observe the tightening torque of the terminal screws. Connecting the Device 1. Observe the safety information given in the instruction manual. 2. Remove the cover on the terminal box. 3. Route the cable through the cable gland into the terminal box. 4. Connect the conductors in the terminals as required for the relevant application, see following figures. 5. Refit the cover of the terminal box. - 11

Mounting and Installation Change-over contact 1 contact 3 contacts M BU M BN L1 BK 2 contacts M YE GN L1 BN BU PK L2 GY BU/RD RD L1 WH YE GN L2 BN BU PK L3 GY Figure 4.3 Connection of magnetic immersion probe LML-P, LML-S NO contact NC contact Change-over contact 1 contact 3 contacts 1 contact 3 contacts 1 contact 3 contacts M 2 contacts M BN L1 BU BU BK L1 BW L2 BG M BN L1 WH YE L2 GN BU L3 RD M 2 contacts M BN L1 BU BU L1 BK BW L2 BG M BN L1 WH YE L2 GN BU L3 RD M 2 contacts M BU BN BK YE GN BN BU PK GY L1 L1 L2 M BU/RD RD L1 WH YE GN L2 BN BU PK L3 GY Figure 4.4 Connection of magnetic immersion probe LML-Ex BG BK BN BU BW GN GY PK RD YE WH Blue-Gray Black Brown Blue Brown-White Green Gray Pink Red Yellow White 12 -

Mounting and Installation Establishing Equipotential Bonding A PE terminal is available in the terminal box for the device. 1. For devices without grounding terminal: Establish an electrical connection to the container via the process connection. 2. For devices with grounding terminal: Establish equipotential bonding via the grounding terminal. - 13

Operation 5 Operation 5.1 Checking the Device Function Danger! Danger to life from electric shock Working on live parts at voltages higher than 50 V AC or 120 V DC can result in electric shock. 1. De-energize the device. 2. Secure the circuit against reconnection. 3. Verify that the device is de-energized at all poles. 4. Provide protection from adjacent live parts, if present. Checking the Device Function When the device is installed, a functional inspection can only be performed from inside the container. We recommend removing the device and checking the function while the device is removed. 1. Disconnect the circuit. 2. Remove the device from the container. 3. Perform a functional inspection on the device as described in the chapter "Checking the Device Function before Mounting", see chapter 4.1. 4. Place the device in the container. 5. Connect the device. 14 -

Troubleshooting 6 Troubleshooting The following table lists the most frequent causes of malfunctions and the necessary countermeasures. Malfunction Possible cause Corrective action No switching function or undefined switching function False switching point dimensions Device cannot be attached at the intended position on the container Table 6.1 False terminal connection Insulation Set collars out of position or replaced incorrectly after the sliding tube is removed. Reed contact defective due to mechanical vibrations. Float installed incorrectly. False ordering information Thread or flange dimensions of the device do not agree. Thread of mounting plug on container defective. Bolt threading on the device defective. Compare with connection diagram, see chapter 4.3 Check terminals Control position of set collar Return to the manufacturer, see chapter 8 Turn float around. Please contact the manufacturer. Reworking of the container Replacement of the mounting plug Return to the manufacturer, see chapter 8 Note! Please contact Pepperl+Fuchs for more information. - 15

Maintenance 7 Maintenance Danger! Danger to life from working in containers In containers, hazardous substances may be present that can result in poisoning or suffocation. Eliminate or reduce hazardous substances. Protect persons that come in contact with hazardous substances by means of suitable protective measures, e. g., by respiratory devices or protective clothing. The device is maintenance free. Checking the Condition of the Device 1. Visually check the condition of the device as part of regular inspection work. 2. Include the device when pressure testing the container. Note! For more information see the corresponding datasheets. Cleaning the Device 1. Clean the device as necessary. 2. Take care not to damage the device. 16 -

Repair, Return, and Disposal 8 Repair, Return, and Disposal Repair Danger! Danger to life from using damaged or repaired devices. Using a defective or repaired device can compromise its function and its electrical safety. Do not use a damaged or polluted device. The device must not be repaired, changed or manipulated. If there is a defect, always replace the device with an original device from Pepperl+Fuchs. Return If there is a defect, always send back the device to Pepperl+Fuchs. Take the following precautions before you return the device to Pepperl+Fuchs. Remove all adhering residues from the device. These residues can be hazardous to health. Fill in the form "Declaration of Contamination". You can find this form on the product detail page at www.pepperl-fuchs.com. Enclose the filled in "Declaration of Contamination" form with the device. Pepperl+Fuchs can examine and repair a returned device, only if a completed form is included in the return. If needed, include special handling instructions with the device. Specify the following information: Chemical and physical characteristics of the product Description of the application Description of the error that occurred (specify error code if possible) Operating time of the device Disposal Observe the following notes during disposal: Observe valid federal/national regulations. Ensure proper separation and reuse of the device components. - 17

Technical Specifications 9 Technical Specifications 9.1 Technical Specifications Magnetic Immersion Probe LML-P General specifications Function principle Supply Rated voltage U n Current consumption Power consumption Directive conformity Low voltage change-over contact, up to 3 contacts 250 V AC/DC 1 A 40 VA Directive 2014/35/EU 61010-1:2010 Conformity Degree of protection IEC 60529:2000 Operating conditions Process conditions Process temperature version PP: -10... 80 C (14... 176 F) version PVDF: -10... 100 C (14... 212 F) Process pressure (static pressure) 3 bar (43.5 psi) Density 0.8 g/cm 3 Ambient conditions Ambient temperature Table 9.1-20... 70 C (-4... 158 F) 18 -

Technical Specifications Magnetic Immersion Probe LML-S General specifications Function principle Supply Rated voltage U n Current consumption Power consumption Directive conformity Low voltage change-over contact, up to 3 contacts 250 V AC/DC 1 A 40 VA Directive 2014/35/EU 61010-1:2010 Conformity Degree of protection IEC 60529:2000 Operating conditions Process conditions Process temperature version LML: -30... 150 C (-22... 302 F) version LML-PVC1: -10... 80 C (14... 176 F) Process pressure (static pressure) 25 bar (362.6 psi) Density version S2: 0.8 g/cm 3 Ambient conditions Ambient temperature version S3: 0.7 g/cm 3-20... 70 C (-4... 158 F) Table 9.2-19

Technical Specifications Magnetic Immersion Probe LML-Ex General specifications Function principle Directive conformity Electromagnetic compatibility NC contact, NO contact, change-over contact, up to 3 contacts Directive 2014/30/EU 61000-6-2:2006, 61000-6-4:2011 Conformity Degree of protection IEC 60529:2000 Operating conditions Process conditions Process temperature Process pressure (static pressure) -30... 150 C (-22... 302 F) 25 bar (362.6 psi) Density version S2: 0.8 g/cm 3 Ambient conditions Ambient temperature Data for application in connection with Ex-areas EC-Type Examination Certificate Group, category, type of protection, temperature class Voltage U i Current I i Internal capacitance C i Internal inductance L i Directive conformity version S3: 0.7 g/cm 3 terminal box: -50... 60 C (-58... 140 F) KEMA 03 ATEX 1496 X II 1/2G EEx ia IIC T3...T6 36 V 100 ma 0 nf 0 H Directive 2014/34/EU 60079-0:2012, 60079-11:2012, 60079-26:2007 Table 9.3 Note! For more information see the corresponding datasheets. 20 -

Technical Specifications 9.2 Dimensions 9.2.1 Magnetic Immersion Probe LML-P 80 x 82 80 x 82 M20 x 1.5 M20 x 1.5 L (min. 95) ~ 75 ~40 L1 (min. 55) 16 30 Ø 55 G1-1/2A Ø 12 L (min. 130) ~ 80 ~60 L1 (min. 70) 20 LML*P7-G5P-DW LML*D5-G6D-DW LML3P7-G1P-DW-**** Figure 9.1 L Specified length, max. 1000 mm Specify the location of the contacts when placing your order. The tube length L will be defined corresponding to the lowest contact location. Minimum distance between L1 and L2: 20 mm If you are using 3 contacts, observe the following distances: minimum distance between L1 and L2: 80 mm (for PVDF: 100 mm) minimum distance between L2 and L3: 20 mm Ø 16 36 Ø 68 G2A L ~40 L3 L2 L1 (min. 55) 20 G3/8A 22 Ø 12 Ø 44 Ø 55 Ø 44-21

Technical Specifications 9.2.2 Magnetic Immersion Probe LML-S M20 x 1.5 80 x 75 M20 x 1.5 80 x 75 L ~75 L1 (min. 55) 16 Ø 55 30 G1-1/2A ~80 LML*S2-G5S-DW LML*S3-G6S-DW LML3S2-G1S-DW-**** LML3S3-G1S-DW-**** Figure 9.2 L Specified length, max. 3000 mm Specify the location of the contacts when placing your order. The tube length L will be defined corresponding to the lowest contact location. Minimum distance between L1 and L2: 20 mm If you are using 3 contacts, observe the following distances: Minimum distance between L1 and L2: 80 mm Minimum distance between L2 and L3: 20 mm ~45 L L1 (min. 55) 20 36 Ø 68 G2A ~45 Ø 12 Ø 12 Ø 44 Ø 52 20 G3/8A L ~45 L3 L2 L1 (min. 55) L ~45 L3 L2 20 G3/8A 22 L1 (min. 55) 22 Ø 12 Ø 44 Ø 12 Ø 52 22 -

Technical Specifications 9.2.3 Magnetic Immersion Probe LML-Ex M20 x 1.5 80 x 75 M20 x 1.5 80 x 75 ~ 75 LML*S2-G5S-**-EX LML3S3-G6S-**-EX Figure 9.3 L Specified length, max. 3000 mm Specify the location of the contacts when placing your order. The tube length L will be defined corresponding to the lowest contact location. Minimum distance between L1 and L2: 20 mm If you are using 3 contacts, observe the following distances: Minimum distance between L1 and L2: 80 mm Minimum distance between L2 and L3: 20 mm ~45 L L L1 (min. 55) ~45 L1 (min. 55) 20 L3 16 L2 30 Ø 55 G1-1/2A ~ 80 36 Ø 68 G2A Ø 12 Ø 44 Ø 12 Ø 52-23

PROCESS AUTOMATION PROTECTING YOUR PROCESS Worldwide Headquarters Pepperl+Fuchs GmbH 68307 Mannheim Germany Tel. +49 621 776-0 E-mail: info@de.pepperl-fuchs.com For the Pepperl+Fuchs representative closest to you check www.pepperl-fuchs.com/contact www.pepperl-fuchs.com Subject to modifications Copyright PEPPERL+FUCHS Printed in Germany 289816 DOCT-5035A 04/2016