LPI SST Surge Filters

Similar documents
Technical Data Sheet Medium Current Power Surge Filters

LPI SG + SST Spark Gap Surge Filter

LPI SG + SS480 Spark Gap Surge Filters

CONNECT AND PROTECT. nvent ERICO Critec SRF N-Series. Surge Reduction Filters

TDS Transient Discriminating Surge Diverters

TECH NOTE #: CPS-1 SUMMARY OF APPLICABLE UL AND IEEE STANDARDS

Surge Protective Devices. STV100K Series. Instruction Manual

Surge Protective Devices. STV100K Series. Instruction Manual

LPI PRODUCT Summary Brochure

ENGR. MARITES R. PANGILINAN, P.E.E.

THE SURGE PROTECTION SOLUTION

Specifications, Installation, and Operating Instructions

TDX Series. Transient Discriminating TM TVSS

SURGE SUPPRESSOR INSTALLATION INSTRUCTIONS. Includes TDS-AR Alarm Relay and TDS-SC Surge Counter. ISSUE: 3 April

Data Sheet. Surge protection devices - A technical overview

Always "On" UPS Systems Inc. USER MANUAL

Surge Protective Devices. STV25K Series. Instruction Manual

PROTEC Z LV the universal solution for transient switching protection for LV motors, generators, transformer LV secundaries, VSD and UPS equipment

Surge Protection for Surveillance Systems

Liebert AccuVar (ACV Series) Surge Protective Device (SPD) (With Noise Filtering) GUIDE SPECIFICATIONS for a Parallel Surge Suppression System

Surge Protective Device

DANGER DANGER: is used in this manual to warn of high voltages capable of causing shock, burns, or death.

GENERAL UL th EDITION BID SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

Surgelogic Surge Protective Device I-Line Plug-On Unit Series

HEMP & IEMI PROTECTION FILTERS FOR MAINS POWER LINES

Lightning and Surge Protection for PV Systems

GENERAL UL th EDITION DESIGN-BUILD SPEC: SURGE PROTECTIVE DEVICES Prepared by THOR SYSTEMS, INC.

GE TR7000 Series Wall Mounted Surge Protective Device (SPD)

the data line series

ZoneMaster Series Surge Protection Devices

glossary GE Digital Energy Power Quality Surge Protective Devices (SPDs)

MDSP-Series 90kA, 150kA, 300kA Modular Distribution Surge Protector Type 2 Class II Surge Arrester

US Catalog March Surge protective devices (SPDs) UL range

Liebert TVSS: The First Line of Defense - Product Overview. Jim Tiesi

"Powering and Protecting Networks and Equipment Connected to It" Jim Pelegris ITW/LINX

Overvoltage Protection Devices

INTRODUCTION TO SPECIFYING SURGE PROTECTION SURGE PROTECTION NOTE 1 INTRODUCTION TERMS PROBABILITY OF SURGES APPEARING:

Tel: Web: Lightning and surge protection help pages

TRI-SERVICE ELECTRICAL WORKING GROUP (TSEWG) 07/16/08 TSEWG TP-3: SURGE PROTECTOR PERFORMANCE AND EVALUATION CRITERIA

GE Digital Energy. Power Quality

GLOSSARY OF TERMS. Surge and Lightning Protection ERICO Inc.

AC Surge Protection Devices

DIVISION 16 SECTION Surge Protective Device Submittal (SPD)

SPM Series Plug-in Surge Protector Type 2/3 (Test Class II/III) Single & Three Phase Surge Arresters

Session Two: Effective Surge Protection Installation

Ethernet Protection A Whole Solution Han Zou, ProTek Devices

L*W*H:120*65*35.5 L*W*H:152*133*48 L*W*H:220*143*48 L*W*H:360*280*132 for 1ph 5A~10A for 1ph 10A~16A for 1ph 20A~45A for 1ph 50A~120A/200kA

BS th Edition wiring regulations Furse overview

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

BSPD Surge Protective Devices

CPS block & CPS nano UL rd Ed. Surge protective devices (SPD)

Protect your facility from the destructive effects of power surges with a fully

Type of surge arrester

Isobar 12-Outlet Network Server Surge Protector, 15 ft. Cord, 3840 Joules, Diagnostic LEDs, 1U Rack-Mount, Metal Housing

AOZ8101. Ultra-Low Capacitance TVS Diode Array. General Description. Features. Applications. Typical Application

After the storm leaves the area, you pat yourself on the back for protecting your data and equipment. The worry is over. Or is it?

NEW surge protective devices

White Paper Surge Protective Devices in Automatic Transfer Switches

INSTALLATION AND OPERATING INSTRUCTIONS

SPM Series. Plug-in Surge Protection

PRACTICAL EXAMPLES OF OVERVOLTAGE PROTECTION

2U Congestion Alert Rack Insert for UK

DAW 8/28/09. TITLE Specification I2R 120/240 RR 120V AC Split Phase Surge Protector PAGE 1 of 9 REVISIONS

Isobar 8-Outlet Surge Protector, 12 ft. Cord with Right-Angle Plug, 3840 Joules, Diagnostic LEDs, Metal Housing

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

How to Select the Best Value Transient Voltage Surge Supressor for Your Equipment

The following standards are the basis of design, manufacture, and test of SPD equipment: Guide for Surge Voltages in Low-Voltage AC Power Circuits

SPM Series Plug-in Surge Protection

DSP 600 SERIES Distribution Surge Protector

Grid to Chip Surge Protection Product Catalog

PDS8u POWER DISTRIBUTION SYSTEM USER'S MANUAL

Overvoltage Protection

Isobar 4-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3330 Joules, Diagnostic LEDs, Metal Housing

Surge Protector. Esma Khatun

In the simplest terms, surge protective devices (SPDs) prevent damaging transient voltage surge levels from reaching the devices they protect.

This is a preview - click here to buy the full publication TECHNICAL REPORT

Surge & Filter Protection Addressing your industrial power quality needs.

2.1. SPD, Power Conditioning, PF Capacitors and Harmonic Filters. Contents Description. Introduction. Surge Protection and Power Conditioning

Isobar 2-Outlet Surge Protector, Direct Plug-In, 1410 Joules, Diagnostic LEDs, Tel/Fax/Modem, Black Metal Housing

Wise HP33 THREE PHASE HIGH PRECISION AVR SURVO-MOTOR AUTOMATIC VOLTAGE STABILIZER

AN4275 Application note

Isobar 6-Outlet Surge Protector, 6 ft. Cord with Right-Angle Plug, 3300 Joules, Diagnostic LEDs, Metal Housing

Surge Protective Device

ITS Heartland: Overview of Transient Overvoltage Surge Protection in ITS/Traffic Systems

Commercial and Industrial LV Power Protection

YOU NEED A WHOLE- HOUSE PROTECTION SYSTEM

Application Note TAN MTL Surge Technologies. Lightning surge protection for electronic equipment - a practical guide.

TransGuard. Electrical Transient Suppression Filter Systems. Installation, Operation and Maintenance Manual PN ,

Designing with Thermally Protected TCMOV Varistors for Type 1 and Type 2 UL1449 3rd Edition Applications

AOZ8900. Ultra-Low Capacitance TVS Diode Array PRELIMINARY. Features. General Description. Applications. Typical Application

Coordinated Facility Protection Selecting Surge Protection

Panelmount (Facility-Wide) Surge Protection

Fundamentals of Thyristor Overvoltage Circuit Protection

INSTALLATION, OPERATION AND MAINTENANCE MANUAL GE TRANQUELL Series Wall Mounted Low and Medium Exposure Surge Protective Devices (SPDs)

Semiconductor Protection Devices

Surgelogic Surge Protective Devices LC, XR, and XW Series

Handling Transient Threats in RS-485 Systems

Surge Protection Devices Ex9UE2

MP7. Uninterruptible Power Supply

Lightning and Surge Protection of Photovoltaic Installations. Leutron GmbH 2013 Leinfelden-Echterdingen, Germany

Transcription:

LPI SST Surge Filters Features High performance surge protector for an operating voltage of 200-240Vac Designed to withstand fault and over-voltage conditions of up to 85Vac, as per IEC664 Impulse discharge current 00kA + 50kA 8/20µs Ph-N Three stage protection provides highest level of protection for sensitive electronic equipment Product Description Designed to suit TT, TN-C, TN-S, TN-C-S & IT distribution systems Non-saturating inductors dv/dt of the incoming surge reduced up to 000 times Primary (00kA 8/20µs) and secondary (50kA 8/20µs) surge protection High N - E protection rating 00kA 0/50µs or 50kA 8/20µs Status indication and optional surge counter Electronic equipment is highly susceptible to damage from lightning and other transient pulses (including man made switching transients), which arrive via the powerlines through direct strike, or inductive and capacitive coupling. Efficient filtering and clamping at the point of entry of power feeds to sensitive electronic equipment is essential to mitigate physical equipment damage, loss of operations and economic loss. The LPI Surge Filter provides multiple stage protection against incoming surges & transients and shall be installed in series with the incoming 200-240Vac single phase (Phase Neutral) mains power supply to the equipment or building. Shunt-only clamping alone is not sufficient, as it does not limit the excessive wavefront characteristic of the pre-clamped waveform. The LPI Surge Filter will reduce the rate of rise of voltage (dv/dt) to below 5V/µs as per AS768 Cat B ka (8/20µs) applied impulse and to below 0V/µs for AS 768 Cat C 20kA (8/20µs) applied impulse. The Surge Filter is designed for multistroke lightning events and comes with the SST (Smart Surge Technology) as the primary protection, rated at 00kA 8/20µs per phase, as the first stage to absorb the majority of the energy. The SST offers the ultimate level of safety and reliability whilst retaining optimum protection levels critical for electronic equipment. SST ensures that the protection device is virtually immune to the effects of 50/60 Hz sustained over voltages, allowing fault voltages up to 85Vac, in accordance with IEC664 requirements. The second stage consists of low pass non-saturating inductors and capacitors (L-C Filtering) which further attenuates the let-through voltage already clamped by the primary stage. The filter attenuates noise and any harmonics present on the power system and is designed to attenuate transverse and common mode noise. The third stage consists of further surge diverters rated at 50kA 8/20µS connected across the load side. These are designed to suppress surges generated by load side equipment. LPI Surge Filter limits the voltage differential due to a lightning induced impulse between phase and neutral as well as from neutral to ground. Thus providing both common mode and differential (transverse) mode protection. Neutral to earth protection rated at 00kA 0/50µs (50kA 8/20µs) is provided to limit feedback currents if the site earth goes high potential with respect to the sub-station or transformer earth. This is a common occurrence due to a near-by direct strike. Commercial in Confidence Document: 6 TD SST Surge Filters.pub Version: 2.0 06/08/2008 Copyright 2008 LPI

Description Rated voltage: Max continuous fault voltages @ 50/60Hz: Operating time: Power distribution systems: Primary surge protection rating Ph-N: Secondary surge protection rating Ph-N: N E protection: Protection Modes: Inductor: Capacitor type: Surge counter (Optional**): LPI SST Surge Filters ac Ph - N @ 50/60Hz 85Vac, as per IEC 664 requirements < ns TT, TN-S, TN-C, TN-C-S (MEN) 00kA 8/20µs single shot surge capacity 50kA 8/20µs single shot surge capacity 00kA 0/50µs or 50kA 8/20µs Transverse and common mode Non-saturating, low pass, power and noise filtering Self healing polypropylene 7 Digit electro-mechanical display Current crest factor: > : Voltage drop: < 2V at full load Efficiency: 99% Overload / short circuit protection: Performance: Filter db point: Standards (Primary and secondary): In-line circuit breaker Typical let-through voltage < 600V Approx 6000Hz. IEC 664-, Meets UL449 Ed requirements Standards (N - E): IEC 664- Surge withstand: Cat. A,B and C surge tests ANSI/IEEE C62.4 and AS 768 Protection status indication: Status indication, and remote alarm contact Environmental rating: IP 65 Enclosure: Colour: Mounting: Metal enclosure with durable polyester powder coat finish Oyster grey Wall mount Operating temperatures: 0 to +50 C, 0 95% humidity Conductor size: Warranty: Accepts up to 5mm² 5 Years manufacturer s warranty SF6A operating temperature 0 to +45 C at maximum load Commercial in Confidence Document: 6 TD SST Surge Filters.pub Version: 2.0 06/08/2008 Copyright 2008 LPI 2

Ordering Code Description Phase Rated Voltage Ph - N Dimensions (mm) Weight (Kg) SF2A-NE Surge Filter, Ph, 2A, 00+50kA 8/20µs Ph - N, SST, 00kA 0/50µs NE, Status 00x200x50 6 SF2A-NEC Surge Filter, Ph, 2A, 00+50kA 8/20µs Ph - N, SST, 00kA 0/50µs NE, Status + Counter 00x200x50 6 SF40A-NE Surge Filter, Ph, 40A, 00+50kA 8/20µs Ph - N, SST, 00kA 0/50µs NE, Status 00x200x50 6 SF40A-NEC Surge Filter, Ph, 40A, 00+50kA 8/20µs Ph - N, SST, 00kA 0/50µs NE, Status + Counter 00x200x50 6 SF6A-NE Surge Filter, Ph, 6A, 00+50kA 8/20µs Ph - N, SST, 00kA 0/50µs NE, Status 00x200x50 6 SF6A-NEC Surge Filter, Ph, 6A, 00+50kA 8/20µs Ph - N, SST, 00kA 0/50µs NE, Status + Counter 00x200x50 6 SF2A-NE Surge Filter, Ph, 2A, 00+50kA 8/20µs Ph - N, SST, 00kA 0/50µs NE, Status 400x00x50 2 SF2A-NEC Surge Filter, Ph, 2A, 00+50kA 8/20µs Ph - N, SST, 00kA 0/50µs NE, Status + Counter 400x00x50 2 SF40A-NE Surge Filter, Ph, 40A, 00+50kA 8/20µs Ph - N, SST, 00kA 0/50µs NE, Status 400x00x50 2 SF40A-NEC Surge Filter, Ph, 40A, 00+50kA 8/20µs Ph - N, SST, 00kA 0/50µs NE, Status + Counter 400x00x50 2 SF6A-NE Surge Filter, Ph, 6A, 00+50kA 8/20µs Ph - N, SST, 00kA 0/50µs NE, Status 400x00x50 2 SF6A-NEC Surge Filter, Ph, 6A, 00+50kA 8/20µs Ph - N, SST, 00kA 0/50µs NE, Status + Counter 400x00x50 2 Add BP to part number for Backplane version. BP version have the same footprint as shown for the enclosure version Commercial in Confidence Document: 6 TD SST Surge Filters.pub Version: 2.0 06/08/2008 Copyright 2008 LPI

Installation All installation work must be carried out by licensed electrical personnel. The power must be disconnected. Ensure no dangerous neutral to earth voltages exist prior to commencing installation work.. The SF unit should be installed as close as practical to the Power Distribution Panel. 2. Affix the SF unit firmly to the wall.. The input and output power cables that connect to the SF unit must have a current rating at least equal to that of the unit being installed. If operating 6A rated filters at loads in excess of 5A or in ambient temperatures in excess of 40ºC, the use of input/output cables rated for temperatures of up to 0ºC is required. 4. Route power cables to the correct side of the unit (input cables to input side of the SF unit, and output cables to output side). Suitable IP65 rated cable glands, with a flammability rating of at least V should be employed at the point of entry to the filter enclosure. 5. Connect the input and output power lines as illustrated in Figure (for single phase units) and Figure 2 (for three phase units). 6. The earthing impedance of the electrical system should be less than 0Ω, with 5Ω recommended. 7. Connect the Earth terminal on the SF unit to the nearest electrical main earth using the shortest possible route. Earthing conductor should be a minimum of 6mm 2, with 6mm 2 recommended. 8. All connections must be rechecked to confirm that they are securely connected. 9. Connect power to the surge filter and confirm that power is being delivered to the load and that all status indicators are green. The surge filter is in series with the load and turning off the filter s internal circuit protection will disconnect power to the load. Figure. Schematic of Ø Surge Filter Figure 2. Schematic of Ø Surge Filter Commercial in Confidence Document: 6 TD SST Surge Filters.pub Version: 2.0 06/08/2008 Copyright 2008 LPI 4

Maintenance. The status indicators on all SST protection modules should always be green. 2. Replace any surge diverter when the corresponding indicator has changed to red or the remote status monitoring is indicating failure of the diverter.. Do not perform maintenance work until power to the surge filter has been disconnected. 4. All surge protection devices will degrade and must be replaced at the end of their life cycle. The frequency of replacement is subject to the magnitude and number of incident surges applied to the device therefore status indication is very important. Remote Status Indication A set of voltage-free contacts integral to each of the SST protection modules (primary and secondary) provides the facility to monitor the protection status of the SF Filter remotely. With the protection module fully operational, the status indicator will be green and terminals & 2 on the remote monitoring terminals will be connected. When the SST protection module MOV material degrades to a point where replacement is necessary, the status indicator will change to red and the voltage free contacts will change state so that terminals 2 & are Figure. Remote Status Monitoring voltage free contacts on protection module Commercial in Confidence Document: 6 TD SST Surge Filters.pub Version: 2.0 06/08/2008 Copyright 2008 LPI 5

Note and Remarks Commercial in Confidence Document: 6 TD SST Surge Filters.pub Version: 2.0 06/08/2008 Copyright 2008 LPI 6