Contents 1. Introduction... 3 2. Packing List...3 3. Features...3 4. Specifications... 3 5. Panel Layout... 5 5.1 Ethernet, Power... 5 5.2 RS-232/485/422 Port... 6 5.3 LED indications...6 6. Installation... 6 7. Software installation and setting...7 7.1 Set the IP address of the device... 7 7.2 Create the Virtual COM port on the PC... 10 8. Application...11 9. FAQ... 12 Page 2 of 12
1. Introduction NP302 series can conveniently connect up to 2 serial devices to an Ethernet, allowing you to network your existing serial devices with only basic configuration. With NP302 series, you can both centralize the management of your serial devices, and distribute management hosts over the network. NP302 series can be used to connect different devices for remote management, each serial port operates independently to provide maximum versatility, each port can be operate in Driver, TCP Server, and TCP Client mode independently. 2. Packing List NP302 series are shipped with following items. 1. NP302 series server 1 2. User manual 1 3. Quick Installation Guide 1 4. Straight network cable 1 5. 5VDC power adapter 1 6. Software CD-ROM 1 7. Product Warranty booklet 1 Optional accessories: DIN-Rail Mounting Kit (35mm) 1 3. Features 1. Adopt 32 bit ARM processor, 125 DMIPS manage ability 2. 2 serial ports, with support for RS-232/RS-485/RS-422 3. Support 10/100M Ethernet 4. Support 300bps-460.8Kbps 5. Support TCP, UDP, ARP, ICMP, HTTP, TELNET and DHCP protocol 6. Support across gateway, router communication 7. Support standard TCP/IP SOCKET 8. Support Virtual serial driver access and auto connect after the network disconnect 9. Choice of configuration methods: Windows, TELNET and WEB 10. Support DIN-Rail or wall mounting installation 4. Specifications Ethernet Number of ports:1 Standard:10/100Base-T(X) Speed:10/100M auto-sensing Working mode: half /full duplex Working: TCP Server, TCP Client, UDP and Real COM driver Page 3 of 12
Memory: Most 32Kbyte Transmission: 100m Electromagnetism isolate: 1KV Connector: RJ45 Serial Standard: RS-232/RS-485/RS-422 Number of ports: 2 Signals: RS-232:DCD,RXD,TXD,DTR,GND,DSR,RTS,CTS RS-485:Data+,Data-,GND RS-422:TXD+,TXD-,RXD+,RXD-,GND Parity: None, Even, Odd, Space, Mark Data bits: 5bit, 6bit, 7bit, 8bit Stop bits: 1, 1.5, 2 Baud rate: 300bps ~ 460.8Kbps Flow control: RTS/CTS or XON/XOFF Direction control: RS485 side adopt ADDC technology, auto text and control data transfer direction Loading: RS-485/422 side support 32 nodes (customize 128 nodes) loopback Transmission: RS-485/422 side 1200M, RS-232 port 15M Interface protection:1500w surge protection, 15KV ESD protection Software Network protocols: Support TCP, UDP, ARP, ICMP, HTTP, TELNET and DHCP Driver support: Windows Real COM driver (Windows NT/2000, Windows XP/2003) Configuration options: Windows, TELNET and WEB Power Power input: 5VDC Consumption: <1W Environment Working temperature:-20 ~60 (-4F~140F) Storage temperature:-25 ~85 (-13F~185F) Humidity: Relative humidity 5% to 95% Appearance Color: Black L W H: 113.0mm 77.0mm 23.5mm Material: Iron (Shell) Weight: 240g Warranty: 5 years Approvals: FCC, CE, RoHS approvals Page 4 of 12
5. Panel Layout 5.1 Ethernet, Power Power: DC-IN 5V:5VDC power supply input 10/100 /100Base-T Base-T(X) Ethernet port: The 10/100BaseT(X) ports located on NP302 series front panel. The pin of RJ45 port display as below. Connect by UTP or STP. The connect distance is no more than 100m. 100Mbps is used 100Ωof UTP, 10Mbps is used 100Ωof UTP 3,4,5. RJ45 port support automatic MDI/MDI-X operation. can connect the PC, Server, Converter and HUB by straight though cable wiring. Pin 1, 2, 3, 6 Corresponding connection in MDI. 1 3, 2 6, 3 1, 6 2 are used as cross wiring in the MDI-X port of Converter and HUB. 10Base-T are used in MDI/MDI-X, the define of Pin in the table as below. MDI(Straight-through cable): pin MDI MDI-X 1 8 signal signal 1 TX+ RX+ 2 TX- RX- 3 RX+ TX+ 6 RX- TX- 4, 5, 7, 8 Note: TX TX± transmit data±, RX RX± receive data±, not use 8 R J 4 5 1 T X + T X - 3 6 3 6 R X + R X - R X + R X - 1 2 1 2 T X + T X - Page 5 of 12
MDI-X (Cross-over cable): R J 4 5 8 1 (R X + ) T X + (R X -) T X - (T X + ) R X + (T X -) R X - 3 6 1 2 1 2 3 6 R X + (T X + ) R X - (T X -) T X + (R X + ) T X - (R X -) 5.2 RS-232/485/422 Port NP302 2-port RS232 to Ethernet NP302-M (1 port RS232+1 port RS485/422) to Ethernet NP302-2M 2-port RS485/422 to Ethernet RS-485/422 (RJ45 RJ45) 1 TXD+/Data+ 2 TXD-/Data- 3 RXD+ 4 RXD- 6 GND RS-232 (RJ45 RJ45) 1 TXD 2 RXD 3 RTS 4 CTS 5 DSR 6 GND 7 DTR 8 DCD 1 8 5.3 LED indications Power supply input: ATC bright all along Serial 1 connected: Port1 on bright all along Serial 2 connected: Port2 on bright all along Connected network: LINK and TX/RX indicator bright all along 6. Installation NP302 series provide DIN-rail and wall mounting two types of installation. Wall mounting installation Page 6 of 12
DIN-Rail Installation Pay attention to the questions as below: (1) Make sure the power supply input is 5VDC; (2) Use the cross-over cable if the devices connect to the PC. (3) Use the straight-through cable if the devices connect to the HUB. Note: Cable (blue) with the product is a straight-through cable. 7. Software installation and setting 7.1 Set the IP address of the device The IP address of the device and the PC must in the same subnet (the default IP of the device is in the subnet of 192.168.1.233). First, must make the IP address of the device in the same subnet network(192.168.1.x) of PC. If they are not in the same subnet network or the IP address have been used by another device, Use Telnet change the IP address of the device. Page 7 of 12
I. Start Start all programs Running Running II. Input default IP address of the device Telnet: 192.168.1.233. Click OK OK, setting the IP of device by telnet. Choose the menu by,,, of the keyboard and quit by ESC ESC key. III. Knock OK OK. Set the IP of device by telnet. Choose the menu by,,, of the keyboard and quit by ESC ESC key. Choose the Server Server menu and Knock Enter Enter key, Change the IP of the device. IV. Change the IP (the changed IP must be in the subnet of the PC). then Knock Esc Esc key, quit the network Page 8 of 12
setting. V. Choose COMMON COMMON, knock Enter Enter, VI. Choose Save Configuration, knock Enter, due to save the setting. Page 9 of 12
7.2 Create the Virtual COM port on the PC I. Setup the setup_nt_2k.exe setup_nt_2k.exe software, you will find the com port over tcp/ip.exe application in the control panel of windows OS. II. Double knock COM port over tcp/ip.exe application and create virtual the serial port to communicate with the device on the PC. III. Choose the name of the virtual serial port and Knock Map Map button. Set the parameter of the virtual serial port. Page 10 of 12
1. Input the IP address of the device 2. Input the NO. of the port of the device(input 1~8) 3. Input 300 4. Default the parameter IV. Knock OK OK, Knock Save Save. Then you can use the created the COM5. V. The virtual serial port COM5 can communicate with the terminal on the NO.1 port of the device. 8. Application Working mode: 1. Based on Virtual COM port 2. Based on WinSock access NOTE: Please note that if PC in Client (Server), the NP302 must in Server (Client) Page 11 of 12
9. FAQ 1. Power adapter is incorrect and connection is incorrect Solution: Please make sure that the power supply is 5VDC 2. Vircom connection is failure, LED indicator is OFF Solution: at first, delete the virtual COM port that do not connect successful. Create a new virtual COM port and connect it, detect LED indicator is ON of OFF 3. Parameter setting is incorrect. Solution: Enter into the management IP address of device through IE browser, check Parity Parity,If it is Mark/space, Parity Check must set space space, then you can adjust Force Packet Transmit Time and Force Packet Transmit Length. Note: If you also have some problem about the NP301B, please contact your customer service representative for support. Page 12 of 12