Global VSAN. Creating VSANs. Global VSAN, on page 1 Fibre Channel Zoning, on page 6

Similar documents
Fibre Channel Zoning

You can monitor or use SPAN on port channels only for ingress traffic.

UCS Direct Attached Storage and FC Zoning Configuration Example

Traffic Monitoring. Traffic Monitoring

Cisco UCS Local Zoning

Configuring the Fabric Interconnects

Question: 1 You have a Cisco UCS cluster and you must recover a lost admin password. In which order must you power cycle the fabric interconnects?

Direct Attached Storage


UCS Uplink Ethernet Connection Configuration Example

LAN Ports and Port Channels

Cisco Prime Data Center Network Manager 6.2

Introducing Cisco UCS Central 1.3

Working with Cisco UCS Manager

Overview. Overview. Cisco UCS 6324 Fabric Interconnect with Cisco UCS B-Series Servers and C-Series Servers, which is. Overview 1

UCS Engineering Details for the SAN Administrator

Service Profiles and Templates

UCS-ABC. Cisco Unified Computing System Accelerated Boot Camp. Length: 5 Days. Format: Lecture/Lab. Course Version: 5.0. Product Version: 2.

VersaStack for Data Center Design & Implementation (VDCDI) 1.0

Configuring Service Profiles

N-Port Virtualization in the Data Center

Question No : 3 Which is the maximum number of active zone sets on Cisco MDS 9500 Series Fibre Channel Switches?

UCS Firmware Management Architecture

Cisco CCIE Data Center Written (Beta) Download Full Version :

vsphere 6.0 with HP ProLiant Gen9 Servers, OneView, 3PAR, Cisco Nexus 5600 and Brocade 6510 Deployment Guide

CCIE Data Center Written Exam ( ) version 1.0

Overview. About the Cisco UCS S3260 System

Real4Test. Real IT Certification Exam Study materials/braindumps

Setting the Management IP Address

On the Cisco Nexus 5548 Switch, Fibre Channel ports and VSAN ports cannot be configured as ingress source ports in a SPAN session.

Setting the Management IP Address

DCNX5K: Configuring Cisco Nexus 5000 Switches

"Charting the Course... Troubleshooting Cisco Data Center Infrastructure v6.0 (DCIT) Course Summary

Backing Up and Restoring the Configuration

Troubleshooting N-Port Virtualization

UCS Technical Deep Dive: Getting to the Heart of the Matter

Configuring SPAN. Configuring SPAN. SPAN Sources. This chapter includes the following sections: Configuring SPAN, page 1

UCS Management Architecture Deep Dive

Unify Virtual and Physical Networking with Cisco Virtual Interface Card

Evolution with End-to-End Data Center Virtualization

Overview. Overview. This chapter includes the following sections:

Vendor: Cisco. Exam Code: Exam Name: Designing Cisco Data Center Unified Fabric (DCUFD) Version: Demo

CISCO EXAM QUESTIONS & ANSWERS

Introducing Cisco UCS Central 1.4

Cisco MDS 9000 Family Blade Switch Solutions Guide

ATTACHMENT A SCOPE OF WORK IMPLEMENTATION SERVICES. Cisco Server and NetApp Storage Implementation

FCoE Configuration Between VIC Adapter on UCS Rack Server and Nexus 5500 Switch

Actual4Test. Actual4test - actual test exam dumps-pass for IT exams

UCS - the computing vision that boosts your business

Statistics Collection Policy Configuration

NetFlow Monitoring. NetFlow Monitoring

Cisco Exam Questions & Answers

UCS Manager Configuration Best Practices (and Quick Start)

Cisco. Exam Questions DCUCI Implementing Cisco Data Center Unified Computing (DCUCI)

Course Description. Boot Camp Date and Hours: The class starts on Saturday 2 nd of April, 2016 Saturdays Only 8:00 AM 4:00 PM Central Standard Time

Oracle Database Consolidation on FlashStack

Q&As. Troubleshooting Cisco Data Center Infrastructure. Pass Cisco Exam with 100% Guarantee

ITBraindumps. Latest IT Braindumps study guide

Expert Reference Series of White Papers. Cisco UCS B Series Uplink Strategies

Configuring Fibre Channel Interfaces

Overview. Cisco UCS Manager User Documentation

CISCO EXAM QUESTIONS & ANSWERS

Working with Cisco UCS Manager

Exam Questions

Windows 2012 NPIV on UCS Configuration Example

Nexus 5000 NPIV FCoE with FCoE NPV Attached UCS Configuration Example

Cisco Actualtests Questions & Answers

CCIE Data Center Lab Exam Version 1.0

UCS deployment guide for Nimble Storage

Migrating Brownfield to Greenfield

Introducing Cisco UCS Central 2.0

A. Both Node A and Node B will remain on line and all disk shelves will remain online.

Implementing Cisco Data Center Unified Computing (DCUCI)

Cisco Traffic Analyzer

Configuring FC Connectivity Using the REST API, on page 12

Vblock Architecture. Andrew Smallridge DC Technology Solutions Architect

PracticeTorrent. Latest study torrent with verified answers will facilitate your actual test

Troubleshooting Distributed Device Alias Services

Cisco Nexus 4000 Series Switches for IBM BladeCenter

Q&As. Troubleshooting Cisco Data Center Unified Computing. Pass Cisco Exam with 100% Guarantee

Configuring Cisco Unified FEX Nexus 2348UPQ with Fiber Channel Interfaces

Question No : 1 Which three options are basic design principles of the Cisco Nexus 7000 Series for data center virtualization? (Choose three.

Questions & Answers

Obtain the hostname or IP address of Cisco UCS Central. Obtain the shared secret that was configured when Cisco UCS Central was deployed.

Vendor: Cisco. Exam Code: Exam Name: Introducing Cisco Data Center Technologies. Version: Demo

CCIE Data Center Storage Networking. Fibre Channel Switching Configuration. Nexus 5500UP FC Initialization Allocate interfaces as type FC

Cisco UCS Manager Storage Management Guide, Release 3.1

Designing and Deploying a Cisco Unified Computing System SAN Using Cisco MDS 9000 Family Switches


Registering Cisco UCS Domains with Cisco UCS Central

IBM eserver BladeCenter. Download Full Version :

Exam Questions

Troubleshooting Cisco Data Center Unified Fabric

Understanding and Troubleshooting UCS Licensing

UCS Fabric Fundamentals

Role-Based Access Controls

Cisco UCS Virtual Interface Card 1225

CCIE Data Center Storage Networking. Fibre Channel Switching

Cisco Director Class SAN Planning and Design Service

CCNP DataCenter. Cisco Certified Network Professional. Silver Learning

Transcription:

, on page 1 Fibre Channel Zoning, on page 6 Cisco UCS Central enables you to define global VSAN in the SAN cloud, at the domain group root, or at a domain group level. The global VSANs created in Cisco UCS Central are specific to the fabric interconnect where you create them. You can assign a VSAN to either Fabric A or Fabric B, or to both Fabric A and B. s are not common VSANs in Cisco UCS Central. Resolution of global VSANs takes place in Cisco UCS Central prior to deployment of global service profiles that reference them to Cisco UCS Manager. If a global service profile references a global VSAN, and that VSAN does not exist, deployment of the global service profile to Cisco UCS Manager will fail due to insufficient resources. All global VSANs created in Cisco UCS Central must be resolved before deploying that global service profile. Note Beginning with Cisco UCS Manager Release 1.3, you can push global VSANs to Cisco UCS Manager without deploying a service profile. For more information, see. Creating VSANs VSANs deployed with a global service profile are visible to Cisco UCS Manager only if a global service profile is deployed that references the VSANs. Once a VSAN deployed with a global service profile becomes available in Cisco UCS Manager, locally-defined service profiles and policies can reference it. A global VSAN is not deleted when a global service profile that references it is deleted. s that are referenced by a global service profile available to a Cisco UCS Manager instance remain available unless they are specifically deleted for use from the domain group. s can be localized in Cisco UCS Manager, in which case they act as local VSANs. Unless a global VSAN is localized, it cannot be deleted from Cisco UCS Manager. This procedure describes how to create VSANs in a domain group in Cisco UCS Central. 1

Creating VSANs Step 5 Step 6 #scope domain-group domain-group /domain-group #scope fc-uplink /domain-group/fc-uplink #scope fabric {a b}. /domain-group/fc-uplink/fabric # create vsan vsan-name vsan-id fcoe-id /domain-group/fc-uplink/fabric/vsan #commit-buffer Enters the UCS domain group configuration mode. Enters fabric configuration command mode. Enters the configuration mode for the chosen fabric interconnect. Enters the VSAN configuration command mode, and creates a VSAN with the VSAN name, VSAN ID, and FCoE VLAN ID that you enter. Commits the transaction to the system. The following example shows how to create two VSANs each for both fabric interconnect A and B in domain group 12: UCSC#connect resource-mgr #scope domain-group 12 /domain-group #scope fc-uplink /domain-group/fc-uplink #scope fabric a /domain-group/fc-uplink/fabric # create vsan VSANA 21 21 /domain-group/fc-uplink/fabric/vsan* #commit-buffer /domain-group/fc-uplink/fabric/vsan # up /domain-group/fc-uplink/fabric # up /domain-group/fc-uplink/fabric # create vsan VSANA2 23 23 /domain-group/fc-uplink/fabric/vsan* #commit-buffer /domain-group/fc-uplink/fabric/vsan # up /domain-group/fc-uplink/fabric # up /domain-group/fc-uplink/up /domain-group/fc-uplink #scope fabric b /domain-group/fc-uplink/fabric # create vsan VSANB 22 22 /domain-group/fc-uplink/fabric/vsan* #commit-buffer /domain-group/fc-uplink/fabric/vsan # up /domain-group/fc-uplink/fabric # up /domain-group/fc-uplink/fabric # create vsan VSANB2 24 24 /domain-group/fc-uplink/fabric/vsan* #commit-buffer /domain-group/fc-uplink/fabric/vsan # up /domain-group/fc-uplink/fabric # up /domain-group/fc-uplink/up 2

Modifying VSAN Settings Modifying VSAN Settings This procedure describes how to modify VSAN settings for either fabric interconnect A or B in a domain group incisco UCS Central. Before you begin Step 5 #scope domain-group domain-group /domain-group #scope fc-uplink /domain-group/fc-uplink #scope fabric{a b} #/domain-group/fc-uplink #/fc-uplink/fabric # scope vsanvsan-name Enters the UCS domain group configuration mode. Enters fabric configuration command mode. Enters configuration mode for the chosen fabric interconnect. Enters VSAN configuration mode for the chosen VSAN. Step 6 Step 7 Step 8 /domain-group/fc-uplink/fabric/vsan # set idvsan-id /domain-group/fc-uplink/fabric/vsan* # set fcoevlanfcoe-vlan-id /domain-group/fc-uplink/fabric/vsan* #set zoningstate {enabled disabled} disabled The upstream switch configures and controls the Fibre Channel zoning, or Fibre Channel zoning is not implemented on this VSAN. enabled Cisco UCS Manager will configure and control Fibre Channel zoning when the VSAN is deployed. Sets the VSAN ID to the value you enter. Sets the FCoE VLAN ID to the value you enter. Sets the Fibre Channel zoning for the VSAN, as follows: Step 9 /domain-group/fc-uplink/fabric/vsan* # commit-buffer Commits the transaction to the system. The following example shows how to modify the settings for a VSAN associated with fabric interconnect A in domain group 12: 3

Enabling s in a Cisco UCS Manager Instance UCSC#connect resource-mgr # scope domain-group 12 #/domain-group #scope fc-uplink #/domain-group/fc-uplink #scope fabric a #/domain-group/fc-uplink #/fc-uplink/fabric # scope vsanvsanc /domain-group/fc-uplink/fabric/vsan # set id2021 /domain-group/fc-uplink/fabric/vsan* # set fcoevlan2021 /domain-group/fc-uplink/fabric/vsan* # set zoningstatedisabled /domain-group/fc-uplink/fabric/vsan* # commit-buffer /domain-group/fc-uplink/fabric/vsan # Enabling s in a Cisco UCS Manager Instance The publish vsan command allows you to use global VSANs that were created in Cisco UCS Central in a Cisco UCS Manager instance without deploying a service profile. #scope domain-mgmt /domain-mgmt #scope ucs-domain domain-id Enters the UCS domain management configuration mode. Enters the UCS domain configuration mode for the specified domain ID. Note If you do not know the UCS domain ID, use the show ucs-domain command. /domain-mgmt/ucs-domain #publish vsan vsan_name [a \ b]. Pushes the selected global VSAN to the Cisco UCS Manager instance in the specified fabric interconnect. The following example shows how to enable global VSAN globvsan for fabric interconnect A in the local domain 1008: # scope domain-mgmt UCSC(resrouce-mgr) /domain-mgmt # scope ucs-domain 1008 UCSC(resrouce-mgr) /domain-mgmt/ucs-domain # publish vsan globvsan a Publish Vsan is a standalone operation. You may lose any uncommitted changes in this CLI session. Do you want to continue? (yes/no): yes /domain-mgmt/ucs-domain # 4

Deleting VSANs Deleting VSANs This procedure describes how to delete one or more VSANs from a Cisco UCS Central domain group. Before you begin Step 5 Step 6 Step 7 #scope domain-group domain-group-name /domain-group #scope fc-uplink /domain-group/fc-uplink #scope fabric{a b} #/domain-group/fc-uplink #/fc-uplink/fabric # scope vsanvsan-name #/domain-group/fc-uplink #/fc-uplink/fabric/vsan # delete vsan #/domain-group/fc-uplink #/fc-uplink/fabric/vsan* # commit-buffer Enters the UCS domain group configuration mode. Enters fabric configuration command mode. Enters configuration mode for the selected fabric interconnect. Enters VSAN configuration mode for the selected VSAN. Deletes the VSAN. Commits the transaction to the system. The following example shows how to delete one VSAN from fabric interconnect A and one from fabric interconnect B for domain group 12: UCSC#connect resource-mgr #scope domain-group 12 UCSC(resrouce-mgr) /domain-group #scope fc-uplink UCSC(resrouce-mgr) /domain-group/fc-uplink #scope fabric a UCSC(resrouce-mgr) /domain-group/fc-uplink/fabric # scope vsan VSANA /domain-group/fc-uplink/fabric/vsan* #commit-buffer /domain-group/fc-uplink/fabric/vsan # up /domain-group/fc-uplink/fabric # up /domain-group/fc-uplink/up UCSC(resrouce-mgr) /domain-group/fc-uplink #scope fabric b UCSC(resrouce-mgr) /domain-group/fc-uplink/fabric # delete vsan VSANB /domain-group/fc-uplink/fabric/vsan* #commit-buffer /domain-group/fc-uplink/fabric/vsan # 5

Fibre Channel Zoning Fibre Channel Zoning Fibre Channel (FC) zoning allows you to partition the Fibre Channel fabric into one or more zones. Each zone defines the set of FC initiators and FC targets that can communicate with each other in a VSAN. The access and data traffic control provided by zoning does the following: Enhances SAN network security Helps prevent data loss or corruption Reduces performance issues Cisco UCS Central FC zoning combines direct attach storage with local zoning. Fibre Channel or FCoE storage is directly connected to the fabric interconnects, and zoning is performed in Cisco UCS Central, using Cisco UCS local zoning. Configuring FC Zoning on a VSAN This procedure describes how to create Fibre Channel zoning on an existing VSAN. #scope domain-group domain-group /domain-group #scope fc-uplink /domain-group/fc-uplink #scope fabric {a b}. Enters the UCS domain group configuration mode. Enters fabric configuration command mode. Enters the configuration mode for the chosen fabric interconnect. Step 5 Step 6 /domain-group/fc-uplink/fabric # enter vsan vsan-name vsan-id fcoe-id /domain-group/fc-uplink/fabric/vsan* #set zoningstate {enabled disabled} disabled The upstream switch configures and controls the Fibre Channel zoning, or Fibre Channel zoning is not implemented on this VSAN. enabled Cisco UCS Manager will configure and control Fibre Channel zoning when the VSAN is deployed. Enters the VSAN configuration command mode for the specified VSAN. Configures Fibre Channel zoning for the VSAN, as follows: 6

Configuring FC Zoning on a VSAN Step 7 /domain-group/fc-uplink/fabric/vsan #commit-buffer Commits the transaction to the system. The following example shows how to set the Fibre Channel zoning state on VSAN VSAN1A on fabric interconnect A in domain group 12: # scope domain-group 12 /domain-group # scope fc-uplink /domain-group/fc-uplink # scope fabric a /domain-group/fc-uplink/fabric # enter vsan VSAN1A 25 25 ForDoc(resource-mgr) /domain-group/fc-uplink/fabric/vsan* # set zoningstate enabled /domain-group/fc-uplink/fabric/vsan* # commit-buffer /domain-group/fc-uplink/fabric/vsan # 7

Configuring FC Zoning on a VSAN 8