CEILING SWIRL DIFFUSER MLD

Similar documents
Ceiling diffusers - visible

VIREO Ceiling with ALX

Slot diffusers, Round duct diffusers IMP Klima 04 Slot diffusers Round duct diffusers 176

GTH. Rectangular double deflection grille QUICK FACTS

Adjustable swirl diffuser PDZA TECHNICAL DATA

Ventilation grille. Dimensions

Grille. Min. - max. dimensions

BAR GRILLE TYPE: A-600

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Swirl diffusers, Variable swirl diffusers Swirl diffusers

Floormaster DVQA, quarter-cylindrical terminals

Jet nozzle, type DW-N2 Swivel jet nozzle, type DW-V2 Twist nozzle, type DW-V2-...-DR

Incorporating V2.2. Product spec >>> > Series CD - Ceiling diffusers

LOOK hidden linear diffusers

NORDgrille Internal grilles

IBISTM. Duct diffuser with discs for supply air

Filter Fan Unit LIGHT

DRI. VARIZON Displacement unit with adjustable spread pattern

Technical Concept. Filter Fan Unit LIGHT. Type LIGHT AC Type LIGHT EC

IBIS. Duct diffuser with discs for supply air QUICK FACTS

PERFORMANCE DATA SCD. SCD 12 in. x 12 in. Face Size. SCD 20 in. x 20 in. Face Size. Square Cone Diffuser

DKC. VARIZON Displacement unit with adjustable spread pattern

Circular and semi-circular displacement outlet Q-Z...

FALCON High Flow. Circular ceiling air diffuser for supply air QUICK FACTS

Grilles Type AR. AE for return air 1 / 1.3 / B / 1

Square swirl diffuser PZK(A,B), PWK(A,B)

Perforated diffuser PAKA, PBKA, PCKA, PDKA, PEKA

Catalogue. Swirl 5. Ceiling Swirl Diffuser Fixed Air Pattern.

Nozzle diffuser DYVZ / Supply air unit DYVB TECHNICAL DATA

MiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities

USER S MANUAL. DAS-G01 The Power of Tomorrow

Standard Frame Axial Fans

S u p p l y a i r h o o d J S I

PROLON INSTALLATION AND START UP GUIDE

Solid Bodies and Disjointed bodies

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS HV-STYLVENT. Wall or window extract fans. Elegant design harmonising with any environment

HV-STYLVENT Series WALL OR WINDOW EXTRACT FANS. Wall or window extract fans HV-STYLVENT. Elegant design harmonising with any environment

LOCAL EXTRACTORS. The ideal extractor for industrial environments. Pure advantage

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Type Differential pressure transducer

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

asense m III in industrial wall mounted housing / CO sensor with built-in general purpose controller

Modelling of a Wall Inlet in Numerical Simulation of Airflow in Livestock Buildings

lindab we simplify construction UltraLink Technical information

SERIES SS. Air Steel PUBLICATION GRILLES 16 JAN 2015

Technical Concept. Filter Fan Unit RETURN AIR. Type RA-AC Type RA-EC

Room controller STRA-17

DCV-SP DCV-SP. DCV-SP Pressure control SPL Version B03 with actuator DA4/8 SMART DAMPERS & MEASURING UNITS. Product description AIN DIN AOUT DCV-SP

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

SLOT DIFFUSERS ALS SERIES SLOT DIFFUSER ALS37. The Airvector exclusive UNIFLEX pattern and volume controller Deflector-damper

Installation VAV-Compact Retrofit Set

Type Differential pressure transducer

System Components Surge Arrester HAW 261 and HAW 262

Switches and Indicators 84

Solid Bodies and Disjointed Bodies

Nokeval. FD100 series. User Manual

Product Brochure Edition 1. t: f: e: doncastercables.com

Non-communicating room controllers

ATV310HU30N4E variable speed drive ATV310-3 kw - 4 hp V - 3 phase

Variable Flow Rate Control Unit

LED-Strip. Product Sheet

Cables. U.S. Registered Trademark EN0B-0341GE51 R0402 Copyright 2002 Honeywell Inc. All rights reserved

ROL and ROL-S. climecon.fi

InReg Volume flow controller Pa

Room unit with PPS2 interface

FUME HOOD CONTROLLER (FHC)

Product Information Fan Powered Terminal Unit For under floor ventilation system Type FAT PI/FAT/M/1

IT COOLING EVAPORATIVE COOLING SYSTEM. 2 STAGE INDIRECT ADIABATIC COOLING SYSTEM FOR LARGE DATA CENTERS FROM 80 TO 320 kw

Fundamentals of CFD and Data Center Cooling Amir Radmehr, Ph.D. Innovative Research, Inc.

CONDUCTOR W4. Installation instruction for W4.1 and W To mount the controller. Controller. Mounting on a DIN rail

Non-communicating room controllers

NEW 74 PS RANGE. Push-buttons, selectors and indicators ø 22mm

Refraction and Polarization of Light

EcoTec SP tables and base cabinets

Gas-actuated thermometer Stainless steel version Model 73

Room Temperature Controller

Use. Functions. OpenAir TM. Linear version, modulating, AC 24 V

Product Catalog. Tracer Controls Tracer ZN517 Unitary Control BAS-PRC012-EN. August 2010

XXA18P1AM12 Ultrasonic sensor cyl. 90 deg M18 - Sn=1m - analog 4-20mA - SYNC - connector M12

Catalogue. electric-, cordless- and. pneumatic power tools. Products for sheet metal processing Edition 2008 / 2009

Small distributed I/O module

Pop-Up Number(s) : to 03, to 08, to 13,

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

C200 VALVE WITH UM ELECTRIC ACTUATOR

Chiller. CG 010 to 130. Remote Air Cooled Condensers Engineering Data Manual. 9.4 to 131 kw

Tracer Controls. Tracer ZN517 Unitary Controller BAS-PRC012-EN

McNair Scholars Research Journal

Installation manual CF8-W-Disp-AL

ATV310H075N4E variable speed drive ATV kw - 1 hp V - 3 phase

EC axial fan - HyBlade

Temperature and humidity regulator H3020 H3021 H3023 H3027. Instruction Manual

Heating Circuit Controller

GALVANIZED-COATED SHELFING SYSTEM SHELVING FOR FOOD

Millenium II +: general characteristics

Power and Cooling for Ultra-High Density Racks and Blade Servers

LED-Strip B12. Product Sheet

Hygrophil HP, type / -20

Air damper actuators

Rotary version, three-position control

Transcription:

CEILING SWIRL DIFFUSER MLD Proektasi Makriyianni Ano Ilioupoli P.O.BOX: 6 P.C.: 1 Thessaloniki GREECE Tel.: +0 687 FAX: +0 68047 WEB SITE: www.aerogrammi.gr E-MAIL: info@aerogrammi.gr

MLD CEILING ROUND SWIRL DIFFUSER GENERAL ΜLD is a round swirl diffuser with adjustable blades. Because of the shape of the main body and the way of the blade adjustment, the diffuser presents big adaptability, so it is possible to use MLD diffuser in small and big heights with small or big air volume supply, in heating or cooling. Consists of a cylindrical body made by aluminium and eight trapezoid blades, convergent to the center, made by steel. In the center there is the mechanism for the blade angle adjustment under a plastic cover. The diffuser is painted electrostatically in color RAL 90 but is possible to be painted and in other RAL color. In the case where we have relatively small installation height and big air volume supply we can use the MLD-DW version where the cylindrical body is double. See more details in the last page. ADJUSTMENT We can regulate the blades corner manually as standard (see instructions in last page). In alternative we can use for the blades corner adjustment: Mechanism which adjusts automatically the corner of the blades according to the supply air temperature (-AUTH). For supply air temperature below 0 o C the blades are in the cooling position, from the 0 o C to the 8 o C the blades corner changes slowly and reaches the heating position where remains for temperatures bigger than 8 o C. The advantages of this method are: a) The installation of the diffuser is exactly the same with the manual adjusted version, b) costs less than the same diffuser with electric actuator, c) we don t have the material and labor cost of the electric installation (wires, switches, potentiometers, fuses etc) and d) after the installation there is no need someone to do something about the adjustment of the diffuser. Details in page 11. Electric actuator on-off (4V or 0V) or analogue (4V or 0V, control signal 0- V). For details, wire connections and restrictions see page 11. WAY OF ORDER For the order of the diffusers MLD we use the following string of letters and numbers. MLD-.. -. - RAL. -. Blank or DW SIZE: 00, 0, 00, 0, 0,, 00, A: for fixing with screws in the front flange, Κ: for fixing with screws in the neck For example: MLD - 00 - A - RAL 900 - AUTH When you order MLD with electric actuator or automatic adjustment you must inform us for the installation height, the air volume supply and the ΔΤ in heating and cooling. This way we will make the proper adjustments in the diffuser. COLOR CODE: i.e.: 90 Blank for manual adjustment or the type of the electric actuator (on-off 0V, on-off 4V, analogue 4V, analogue 0V) or AUTH for automatic adjustment.

MLD CEILING ROUND SWIRL DIFFUSER DIMENSION TABLES MLD FIXING WITH VISIBLE SCREWS SECRET FIXING WITH SCREWS IN THE NECK OF THE DIFFUSER SIZE Ø A Ø B Ø C Ø D Ø E F G H 00 00 19 0 8 0 1 0 0 4 00 0 8 0 1 00 00 9 0 4 8 0 1 0 0 4 0 4 8 0 1 0 0 9 4 8 0 1 44 00 0 8 0 1 00 00 49 8 6 8 4 00 6 674 684 7 8 4 00 MLD-DW SIZE A B C D E F G H I 00 19 00 0 0 8 41 19 0 4 0 00 4 8 41 19 00 9 00 0 4 8 41 19 0 4 0 0 4 8 41 19 0 9 0 0 8 41 19 44 00 8 6 8 41 19 INSTALLATION The diffuser installation is possible a) in false ceiling using a plenum box (1,), b) in round sleeve after a round or rectangular visible air duct (,4) c) in false ceiling using flexible duct (). In the first case the diffuser is fixed with screws either from the external flange (visible fixing) either from the neck (secret fixing), in this case the plenum box is fixed by wire cords in the ceiling. In the second case the diffuser is fixed with screws from the external flange or the neck, depends on the sleeve diameter. INSTALLATION IN INSTALLATION IN INSTALLATION IN INSTALLATION IN INSTALLATION WITH PLENUM BOX (A) PLENUM BOX (B) ROUND SLEEVE (A) ROUND SLEEVE (B) FLEXIBLE DUCT 1 4

MLD CEILING ROUND SWIRL DIFFUSER In the third case the diffuser is fixed in the false ceiling with screws in the external flange and in the back is connected the flexible duct. In any case, like every diffuser, we must take care the supply air to reach equalized in the diffuser. If we have plenum box we must install perforated equalizing grid. If we have sleeve this must have length at least three diameters or equalizing grid. If we have flexible duct this must be vertical for length of three diameters. The equalizing grid must have big free area to avoid big pressure drop. If we have damper before the diffuser this must be at a distance of three diameters or before the equalizing grid. CALCULATION EXAMPLE For the calculation of the MLD diffuser we use the selection diagrams of the next pages. The first of the diagrams is an example of a full calculation. The sizes which appear in the diagrams are described in the following table. The sizes which their symbols are in grey background are the data where we must know to make the calculation. DESCRIPTION OF SIZES MENTIONED IN THE SELECTION DIAGRAMS SYMBOL SIZE MEAS. UNIT. Τ h : Supply air temperature in heating (in the diffuser) ο C Τ rh : Room air temperature in heating ο C Τ c : Supply air temperature in cooling (in the diffuser) ο C Τ rc : Room air temperature in cooling ο C ΔΤ h : Temperature deference of supply room air in heating Κ ΔΤ c : Temperature deference of room - supply air in cooling Κ V room : Total air volume supply in the room via MLD diffusers m /h V sup : Air volume supply per diffuser m /h n: Number of MLD diffusers pcs h: Installation height m a: Minimum distance between diffusers m v x : Air velocity, in cooling, in height 1,8m from the floor m/sec v o : Air velocity in the neck of the diffuser m/sec v x /v ο : Ratio of air velocity in height 1,8m to the air velocity in the diffuser, in cooling a h : Blade corner in heating ο a is : Blade corner in isothermal ο a c : Blade corner in cooling ο Δp h : Pressure drop in the diffuser in heating Pa Δp is : Pressure drop in the diffuser in isothermal Pa Δp c : Pressure drop in the diffuser in cooling Pa Lw h : Noise from the diffuser in heating dβ(a) Lw is : Noise from the diffuser in isothermal dβ(a) Lw c : Noise from the diffuser in cooling dβ(a) As we see in the example of the next page we start from the V sup line and we proceed according to the arrows vertical (upwards and downwards) changing direction in the known values of the h, ΔΤ h, ΔΤ c, v x. This way we take the results. For the pressure drop and the noise we have values for the blade corners 0 ο, 4 ο, ο. Usually from the calculations we take different corners from these. So based in the values we take for the corners 0 ο, 4 ο, ο we calculate with interference the values of the noise and the pressure drop for the case where we study. 4

Pressure drop Noise MLD- 0 ROUND CEILING SWIRL DIFFUSER Heating a [m] EXAMPLE 1,,, 4,7,8 7,0 8, 9, VALUES Τ h= [ ο C] Ι,7 7,0 ΔΤ h [Κ] Τ rh= [ ο C] Τ c= 1 [ ο C] 4, h [m] 0 Τ rc= [ ο C] ΔΤ h= [Κ] ΔΤ c= [Κ] V room= 00 [m /h] 1 4 6 7 8 v o 4 800 0 10 000 0 800 00 0 Vsup [m /h] 1 0 0 4 0 6 a h [ ο ] :Best operation area V sup= 0 [m /h] n= [pcs] h=,7 [m] a=,9 [m] Cooling/Isothermal v x= 0, 0, 0,1 v v x x 7,0,7 4, h [m] v o=, v x/v ο= 0,06 ι a h= 9 [ ο ] 0,0 vx/vo 0,01 BLADES CORNER [s 0, 0,0 0,1 0, 6 1 a is= 46 [ ο ] a c= 4 [ ο ] Δp h= 19 Δp is= 6 Δp c= Lw h= Lw is= 4 ac [ ο ] 0 4 ΔΤ C [Κ] Lw c= 4 USEFUL EQUATIONS ΔΤ h=τ h-τ rh [Κ] 0 0 4 0 a is [ ο ] ΔΤ c=τ rc-τ c[κ] n=v room/v sup [pcs] 0 ο 4 ο ο 80 0 0 0 00 0 00 00 000 V sup [m /h] 0 0 0 0 00 00 000 V sup [m /h] 0 0 0 0 00 00 000 V sup [m /h] 0 ο 4 ο ο 00 00 0 0 0 0 00 00 000 V sup [m /h] 0 00 00 000 V sup [m /h] 0 00 00 000 V sup [m /h]

Pressure drop Noise MLD- 00 ROUND CEILING SWIRL DIFFUSER Ι Heating a [m] 0,7 1,1 1, 1,8,,6,0,,7 4,1 4,4 VALUES Τ h= [ ο C] 4,0 ΔΤ h [K] Τ rh= [ ο C] Τ c= [ ο C],4 h [m] Τ rc= [ ο C] ΔΤ h= [Κ],7 ΔΤ c= V room= [Κ] [m /h] 1 1,,, 4 4,, 6 v o 1 1 0 90 0 00 680 V sup [m /h] 1 0 0 4 0 6 a h [ ο ] : Best operation area V sup= [m /h] n= [pcs] h= [m] a= [m] Cooling/Isothermal v x= 0, 4,0,4,7 v o= 0, 0,1 v x h [m] v x/v ο= a h= [ ο ] ι 0,0 vx/vo v x 0, 0,0 0,1 0, a is= [ ο ] a c= [ ο ] Δp h= 0,01 BLADES CORNER 7 6 1 Δp is= Δp c= Lw h= Lw is= ac [ ο ] 0 4 ΔΤ c[κ] Lw c= USEFUL EQUATIONS 0 0 4 0 a is [ ο ] ΔΤ h=τ h-τ rh [Κ] ΔΤ c=τ rc-τ c [Κ] n=v room/v sup [pcs] 0 ο 4 ο ο 80 0 0 0 0 00 00 000 V sup [m /h] 00 0 0 0 0 00 00 000 V sup [m /h] 0 0 0 0 00 00 000 V sup [m /h] 0 ο 4 ο ο 00 00 0 0 0 0 00 00 000 V sup [m /h] 0 00 00 000 V sup [m /h] 0 00 00 000 V sup [m /h]

MLD- 0 ROUND CEILING SWIRL DIFFUSER Ι Heating 4,0 Pressure drop Noise 4,8,1 a [m] 0,8 1,7,6,4 4,,1 6,0 6,8 h [m] 1 ΔΤ h [Κ] VALUES Τ h= [ ο C] Τ rh= [ ο C] Τ c= [ ο C] Τ rc= [ ο C] ΔΤ h= ΔΤ c= V room= [Κ] [Κ] [m /h] 1 4 6 7 8 v o 00 0 0 800 00 0 10 Vsup [m /h] 1 0 0 4 0 6 a h [ ο ] : Best operation area V sup= [m /h] n= [pcs] h= [m] a= [m] Cooling/Isothermal v x= 4,8 4,0,1 v o= 0, v x/v ο= ι 0,1 v x h[m] α h= [ ο ] vx/vo 0,01 BLADES CORNER [s 0, 0,0 0,1 0,1 6 1 α is= [ ο ] α c= [ ο ] Δp h= Δp is= Δp c= Lw h= Lw is= ac [ ο ] 0 4 ΔΤ c [Κ] Lw c= USEFUL EQUATIONS ΔΤ h=τ h-τ rh [Κ] 0 0 4 0 a is [ ο ] ΔΤ c=τ rc-τ c [Κ] n=v room/v sup [pcs] 0 ο 4 ο ο 80 0 0 0 00 0 00 00 000 V sup [m /h] 0 0 0 0 00 00 000 V sup [m /h] 0 0 0 0 00 00 000 V sup [m /h] 0 ο 4 ο ο 00 00 0 0 0 0 00 00 000 V sup [m /h] 0 00 00 000 V sup [m /h] 0 00 00 000 V sup [m /h]

Pressure drop Noise MLD- 00 ROUND CEILING SWIRL DIFFUSER Ι Heating, a [m] 1 4 6 7 8 ΔΤ h [Κ] VALUES Τ h= [ ο C] Τ rh= [ ο C] Τ c= [ ο C] 4,6 Τ rc= [ ο C] ΔΤ h= [Κ], h [m] 1 ΔΤ c= V room= [Κ] [m /h] 1 4 6 7 8 v o 00 0 800 00 0 10 1800 000 00 V sup [m /h] 1 0 0 4 0 6 a h [ ο ] : Best operation area V sup= [m /h] n= [pcs] h= [m] a= [m] Cooling/Isothermal v x= 0, 0,1 v x, 4,6, h[m] v o= v x/v ο= ι α h= [ ο ] 0,0 vx/vo 0,01 BLADES CORNER [s 0, 0,0 0,1 0,1 6 1 α is= [ ο ] α c= [ ο ] Δp h= Δp is= Δp c= Lw h= Lw is= ac [ ο ] 0 4 ΔΤ c [Κ] Lw c= USEFUL EQUATIONS ΔΤ h=τ h-τ rh [Κ] 0 0 4 0 a is [ ο ] ΔΤ c=τ rc-τ c [Κ] n=v room/v sup [pcs] 0 ο 4 ο ο 80 0 0 0 00 0 00 00 000 V sup [m /h] 0 0 0 0 00 00 000 V sup [m /h] 0 0 0 0 00 00 000 V sup [m /h] 0 ο 4 ο ο 00 00 0 0 0 0 00 00 000 V sup [m /h] 0 00 00 000 V sup [m /h] 0 00 00 000 V sup [m /h]

MLD- 0 ROUND CEILING SWIRL DIFFUSER Ι Heating Pressure drop Noise a [m] 1,,, 4,7,8 7,0 8, 9, VALUES Τ h= [ ο C],7 7,0 ΔΤ h [Κ] Τ rh= [ ο C] Τ c= [ ο C] 4, h[m] 0 Τ rc= [ ο C] ΔΤ h= [Κ] ΔΤ c= [Κ] V room= [m /h] 1 4 6 7 8 v o 4 800 0 10 000 0 800 00 0 V sup [m /h] 1 0 0 4 0 6 a h [ ο ] : Best operation area V sup= [m /h] n= [pcs] h= [m] a= [m] Cooling/Isothermal v x= 0, 0,1 v x 7,0,7 4, h[m] v o= v x/v ο= ι α h= [ ο ] 0,0 vx/vo 0,01 BLADES CORNER [s 0, 0,0 0,1 0, 6 1 α is= [ ο ] α c= [ ο ] Δp h= Δp is= Δp c= Lw h= Lw is= ac [ ο ] 0 4 0 ΔΤ c [Κ] Lw c= USEFUL EQUATIONS ΔΤ h=τ h-τ rh [Κ] ΔΤ c=τ rc-τ c [Κ] 0 4 0 a is [ ο ] n=v room/v sup [pcs] 0 ο 4 ο ο 80 0 0 0 00 0 00 00 000 V sup [m /h] 0 0 0 0 00 00 000 V sup [m /h] 0 0 0 0 00 00 000 V sup [m /h] 0 ο 4 ο ο 00 00 0 0 0 0 00 00 000 V sup [m /h] 0 00 00 000 V sup [m /h] 0 00 00 000 V sup [m /h]

Pressure drop Noise MLD- 00 ROUND CEILING SWIRL DIFFUSER Ι Heating 11,0 a [m],7,4 8,1,8 1, 16, 18,9 0, 14,0 h (m) ΔΤ h [ ο Κ] VALUES Τ h= [ ο C] Τ rh= [ ο C] 8,0,0 0 Τ c= [ ο C] Τ rc= [ ο C] ΔΤ h= [Κ] ΔΤ c= [ ο Κ] V room= [m /h] 4 6 7 8 9 11 1 1 14 1 v o 10 00 0 4800 00 800 900 0 V sup [m /h] 1 0 0 4 0 6 a h [ ο ] : Best operation area V sup= [m /h] n= [pcs] h= [m] a= [m] Cooling/Isothermal v x= 0,1 v x 11 14 8 h(m) v o= v x/v ο= ι 0,0 0,01 0,00 vx/vo [s 0, 0,0 0,1 0,1 a h= [ ο ] a is= [ ο ] a c= [ ο ] Δp h= Δp is= ΓΩΝΙΕΣ ΠΤΕΡΥΓΙΩΝ BLADES CORNER 6 1 Δp c= Lw h= Lw is= αc [ ο ] 0 4 ΔΤ c [Κ] Lw c= USEFUL EQUATIONS ΔΤ h=τ h-τ rh [ ο Κ] 0 0 4 0 α is [ ο ] ΔΤ c=τ rc-τ c [ ο Κ] n=v room/v sup [pcs] 0 ο 4 ο ο 80 0 0 0 00 0 00 00 000 V sup [m /h] 0 0 0 0 00 00 000 V sup [m /h] 0 0 0 0 00 00 000 V sup [m /h] 0 ο 4 ο ο 00 00 0 0 0 0 00 00 000 V sup [m /h] 0 00 00 000 V sup [m /h] 0 00 00 000 V sup [m /h]

MLD - CEILING ROUND SWIRL DIFFUSER BLADES CORNER ADJUSTEMENT WITH ELECTRIC ACTUATOR AC 0V ON-OFF: AC/DC 4V ON-OFF: There are two types of electric actuators, which are used to adjust the blades corner (for diameter Ø0 and up): On-off ( point) or analogue. The on-off actuators allow us through a switch who gives or interrupts the electric power in the contact No, to put the blades in two different corners (cooling-heating) calculated by the diagrams of the previous pages. The analogue actuators allow us, through a 0-V potentiometer connected in the contact No, to adjust the blades corner in any position between corners limits (cooling-heating) calculated by diagrams of the previous pages. In the analogue actuators the signal of the contact No is used to read the actuator position (position feedback). For the electric actuators: Max. Temperature: 0 o C, Max. Relative Humidity: 9% AC/DC 4V ANALOGUE AC 0V ANALOGUE In diffusers Ø00 and bigger AUTOMATIC BLADES ADJUSTMENT WITH THERMAL ACTUATOR The automatic blades adjustment is achieved through a mechanism, which moves an axis, according to the supply air temperature. This movement is intense in the temperature area of 0-8 C, and very small outside this area. Considering that the supply air temperature is usually less than 0 C in cooling and more than 8 C in heating we can use this phenomenon with a proper motion transmission mechanism to adjust automatically the blades corner in the values calculated by the diagrams of the previous pages. 11

MLD CEILING SWIRL DIFFUSER MLD-DW In the MLD type swirl diffuser while the blades are being closed the pressure drop and the noise increase, because the free surface of the diffuser decreases. So, the pressure drop and the noise in cooling are higher than heating. This takes place too little in the MLD-DW type, because of its double wall design, while at the same time the vertical throw in heating is not affected (so long as the blades are in a little more vertical position than the blades of simple MLD). In heating the blades are near to the vertical position, so the air flow doesn t meet too much resistance during exiting the diffuser. A little amount of air leaks from the side of the diffuser through the double wall. In cooling, when the blades are being closed the air flow meets much resistance, so an important part of its amount leaks from the side of the diffuser through the double wall, therefore the air exiting velocity is lower in the cooling (in comparison with the simple MLD). So the pressure drop, the noise and the air velocity in the occupied zone are lower. GUIDELINES FOR THE MANUAL DIFFUSER ADJUSTMENT We unscrew and remove the hemispherical cup (A) in the centre of the diffuser. We unscrew a little the screw (B) which Β is into the C shaped slot. D We rotate an opposite positioned blades pair (C) to adjust the corner of all the blades in the desired value (We see the corner with the arrow (D)). We tight the screw (Β) to fix the blades in the desired position. We screw again the cup (Α). MLD(-DW) IN PLATE SPR When we want to install the diffusers MLD, MLD-DW in false ceiling with dimensions 0X0 mm we can use the plate SPR. SPR is a steel plate with thickness 1mm and outside dimensions 9X9mm with round hole in the center for diffuser installation. The plate and the diffuser are electrostatically painted in RAL color. Possible nominal diffuser dimensions for installation in SPR: -For MLD: 00, 0, 00, 0, 0,. -For MLD-DW: 00, 0, 00, 0, 0. A C C Proektasi Makriyianni Ano Ilioupoli P.O. BOX: 6 P.C.: 1 Thessaloniki GREECE TEL.: +0 687 FAX: +0 68047 WEB SITE: www.aerogrammi.gr E-MAIL: info@aerogrammi.gr