SIRIUS 200 U1X200A SRS U1X200A SRS USER S MANUAL

Similar documents
Rhino Buffer Module PSM24-BFM600S. Operating Instructions

CUS150M1 Instruction Manual

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

2260B-RMK-Series Rack Mount Kit

Power Supply HARTING pcon

ELV12 Series. Instruction Manual

Power Supply HARTING pcon

HV-CS kv Edge Mount Triaxial Jack

Safety Standards. Model Number:

Safety Standards. Model Number:

High Power Electronic Gear Installation and operation Guide

Model 7705 Control Module

INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1

PSU. User s manual. Rev. 0

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

POWERSOLVE ELECTRONICS LTD PSL400-XX series Conduction Cooled Power Supply Engineering Specification

PHOENIX CONTACT - 07/2006

Safety Standards. Model Number:

Safety Standards. Model Number: Unit Weight:

DC561, digital input/output module,

DX561 Digital Input/Output Module

RT12-240V/2.4kW Rectifier Specification

RT4F-110V/25A RECTIFIER

RT4F-120V/20A-WAC RECTIFIER

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

Safety Standards. Model Number:

Original operating instructions Fail-safe inductive sensor GG711S

300 WATT, PFC, OPEN FRAME POWER SUPPLIES TABLE 1. OUTPUT RATINGS AND SPECIFICATIONS, RMW 300W SERIES

MV SERIES MACHINE VISION STROBOSCOPE. Operating Manual

DC562, digital input/output module,

Original operating instructions Fail-safe inductive sensor GI712S

400AUS24 B MDS AUS. MDS Medical AC-DC Open Frame 24Volt, 400Watt / MDS-400AUS24 B. General Description. Model Information. Model Numbering ```

Safety Standards. Model Number:

CliQ II Buffer Module 24V 20A / DRB-24V020AB

Chrome DC-UPS Module 24V 10A / DRU-24V10ACZ

TU531, TU532 Terminal Unit

RT4F-48V/50A-WAC RECTIFIER

Model 8020-KHV. Kelvin Keithley Triaxial Connector Card. Description / October 2014 *P * 1

Safety Standards. Model Number:

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODELS:

Safety Standards. Model Number:

Original operating instructions Fail-safe inductive sensor GF711S / / 2013

PSU User s manual Rev. 0 January

Multifunctional time delay relay MFT U31S, MFT U41SE

Chrome DIN Rail Power Supply 5V 7.5W 1 Phase (Class II & NEC Class 2) / DRC-5V10W1AZ

Content. Time delay relays mounting position. Multifunctional time delay relay Clock-pulse generator time delay relay... 3.

RT4B-110V/12A RECTIFIER

AX521 Analog Input/Output Module

Power supply CP-C 24/5.0

RTU500 series Data Sheet Power Supply CP-E 24/2.5

Ferrous metal (The sensing distance decreases with non-ferrous metal.) Power supply voltage (operating voltage range)

Model Number Structure

CliQ II Buffer Module 24V 20A / DRB-24V020AB

H-series (Rectifier Module)

MAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS

G3PC. Model Number Structure. Solid State Relays with Failure Detection Function. Model Number Legend

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

SPECIFICATION. For SWITCHING POWER SUPPLY M/N: MPD-F113-V

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

TF501, TF521 Terminal Bases

040APS12 B MDS. MDS Medical AC-DC Open Frame 12Volt, 40Watt / MDS-040APS12 B ``` Highlights & Features. Safety Standards.

Model 8020-STC. Kelvin Standard Triaxial Connector Card. Description / October 2014 *P * 1

Line Impedance Stabilization Network (LISN)

Redundancy unit CP-A RU

Safety Standards. Model Number:

CliQ II DC-UPS Module 24V 40A / DRU-24V40ABN


PHASED OUT. LED control gear Linear / area dimming. Uconverter LCAI 70 W 300 ma I010 one4all V ECO series

DI572 Digital Input Module

ENGINEERING SPECIFICATION SHEET SPEC. Revision History

Model 2657A-LIM-3 LO Interconnect Module

Model Number Structure

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Safety Standards. Model Number:

Chrome Class II DIN Rail Power Supply 24V 10W 1 Phase (NEC Class 2 & Household) / DRC-24V10W1HZ

AO523 Analog Input Module

AI561 Analog Input Module

Safety Standards. Model Number:

Control Panel CP600 CP651, CP651-WEB

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

P216. Condenser fan speed controller. Product bulletin. Features

DC541 Digital Input/Output Module

Chrome DIN Rail Power Supply 12V 9.96W 1 Phase (Class II & NEC Class 2) / DRC-12V10W1A

CI542 PROFIBUS Communication Interface Module

ekorrps MULTIFUNCTIONAL PROTECTION UNIT CONFIGURATION AND GENERAL CHARACTERISTICS LIB

CD522 Encoder, Counter and PWM Module

Model 2600B-PM V Protection Module with 1 A Clamp. Description / April 2015 *PPA * 1

Model 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1

SPECIFICATION 全漢企業股份有限公司 R&D CHECK APPROVED REV. JOGE 01. FSP Technology Co.,Ltd. 台灣桃園市建國東路 22 號 TEL: FAX:

Control Panel CP600-eCo CP604, CP604-B

DC522 Digital Input/Output Module

DC532-XC, digital input/output module,

TEP 100WIR Series, 100 Watt

Model 2380 Rack-Mount Kit

Siemens Industrial s

Models 2601B, 2602B, and 2604B System SourceMeter Instruments Quick Start Guide

CliQ II Buffer Module 24V 40A / DRB-24V040ABN

COMPACT LED DRIVERS. EasyLine Simple Fix. EasyLine SIMPLE FIX , , , , ,

VS-P Series. TDK-Lambda INSTRUCTION MANUAL

Transcription:

SIRIUS 200 U1X200A12-310-SRS U1X200A24-310-SRS USER S MANUAL Belgrade, March 2005

CONTENTS 1 GENERAL 1.1. IMPORTANT NOTICES 2 TECHNICAL SPECIFICATIONS 2.1. INPUT (MAINS) 2.2. OUTPUT 2.3. ENVIROMENTAL CONDITIONS 2.4. MECHANICAL CHARACTERISTICS 3 CONNECTIONS 3.1. TOP VIEW 3.2. BLOCK DIAGRAM CONNECTING IN SINGLE MODE 3.3. BLOCK DIAGRAM CONNECTING IN PARALLEL MODE 3.4. MOUNTING PRECAUTIONS 4 MANAGING 4.1. GENERAL 5 APPENDIXES 5.1. APPENDIX 1 5.2. APPENDIX 2 5.3. APPENDIX 3 6 LATEST MODIFICATIONS AND UPGRADES Page 2 of 12

1 GENERAL 1.1. IMPORTANT NOTICES Sirius 200 is delivered as an open-frame module, intended for installation in lighting equipment of official vehicles. Only trained personnel is permitted to manage this device. Only authorized personnel is permitted to perform servicing of the device, including lamp replacement. To avoid the risk of lethal electric shock, all warnings and recommendations in this document must be observed and strictly adhered to. Connector KON1 is considered disconnect device. This means that it must be always be disconnected before service actions. After disconnection, allow 4 minutes for capacitors to discharge before handling the device. WARNING: Voltage on flash lamp contacts may exceed 10kV during the ignition cycle. WARNING: If the main switch is turned on and supply voltage is present on input contacts of the device, voltage on flash lamp contacts is extremely dangerous 400V dc. WARNING: If the main switch is turned on and supply voltage is present on input contacts of the device, voltage on certain points of the device exceeds 1200V. WARNING: Flash lamp light radiation may seriously damage the eye of the observer. Never look directly into the light source during installation procedure. Sirius 200 is not an insulated device. Lethal electric shock may occur between the device and the chassis of the vehicle. Measuring equipment (oscilloscope, PC, scope cards, etc) must be disconnected from earth during operation. Connecting some points to the earth potential via probe contacts may form inductive loop with large area. This action may cause very strong high frequency radiation which will produce the illegal operation code situations on the digital logic of the connected equipment. Page 3 of 12

2 TECHNICAL SPECIFICATIONS SIRIUS 200 2.1. Input Input voltage 12Vdc nominal Input voltage range 10.0 to 15 Vdc Input power 22W max. Input current - typ. 1.8A max. Input current - max 2.2A max. Inrush current 30A (peak) Energy reserve 10 ms Efficiency (20 110% of nominal load) >90% 2.2. Output Max. power repetitive mode 20W Single flash energy 12J/6J *(1) Flash duration 2ms Flash frequency 3Hz*(2) Flash lamp voltage range 200 to 400Vdc Igniter voltage (HF) 10kV Switching frequency 200 khz 2.3. Environmental conditions Operating temperature range 0 to +55 C Storage and transport temperature range -45 to +85 C Operating humidity (no condensation) 30 to 95% Storage and transport humidity (no condensation) 10 to 95% 2.4. Mechanical characteristics Weight Height without flash lamp Diameter 0.25 kg 50 mm 92 mm See appendix 1. *(1) Flash sequence: First flash 12J Second flash 6J *(2) Two flash sequences during 1.5 sec. Table 1. Min. value Max. value Nominal Flash current 1A 250A 200A Flash duration 100us 5ms 1ms Lamp voltage 50V 400V 310V Flash Energy 2J 35J 12J Flash power 50W 120kW 60kW Page 4 of 12

3 CONNECTIONS 3.1. TOP VIEW Picture 1. 3.2. BLOCK DIAGRAM CONNECTING IN SINGLE MODE Picture 2. Page 5 of 12

3.3. BLOCK DIAGRAM CONNECTING IN PARALLEL MODE Picture3. Page 6 of 12

3.4. MOUNTING PRECAUTIONS Always make sure that plastic insulation is present between the printed circuit board and the mounting distancers. The helical flash lamp should be mounted so that the red dot designating its positive end (or any other reference marking positive) should match the red dot on the module. Page 7 of 12

4 MANAGING 4.1. GENERAL 1) Before beginning the connection steps, the user must make sure there is no DC voltage present. 2) If the module s serial number is marked A, all reverse polarity connection will cause internal damages, and the necessity to repair the module. For connection polarities follow indications mentioned in Picture 1. Picture 2 shows the appropriate connections of modules SIRIUS 200 working in parallel. The 12V dc power supply must be common for all modules. Electrolytic capacitors C18, C19 should not be mounted directly onto the circuit board of the module. They should be connected to the module through insulated cable, which is at least 2.5mm in diameter, and is shorter than 20cm. 3) Turn on the 12V power supply and check if the device is working properly. In case of malfunction, turn off the power supply, wait for 4 minutes, disconnect the device and call authorized service personnel. Page 8 of 12

5 APPENDIXES 5.1. APPENDIX 1 Voltage diagrams on characteristic points of SIRIUS 200 CH1 -> FLASH LAMP VOLTAGE LAMP 1 0-310V Page 9 of 12

5.2. APPENDIX 2 Voltage diagrams on characteristic points of SIRIUS 200 CH1 -> FLASH LAMP VOLTAGE LAMP 1 0-310V CH2 -> FLASH LAMP VOLTAGE LAMP 2 0-310V Page 10 of 12

5.3. APPENDIX 3 Voltage diagrams on characteristic points of SIRIUS 200 CH1 -> DRAIN VOLTAGE Q1 Page 11 of 12

6 LATEST MODIFICATIONS AND UPGRADES SIRIUS 200 series marked with B and C will have built-in protection from accidental reversing of polarity. Also, all series ( A, B and C ) marked 12/24 will capable of working with input voltages from 9 to 33 Volts. The software and hardware enabling such operation is under testing, and will be available in April 2005. Page 12 of 12