Setpoint Isolators. Technical Manual. HA Issue Parker SSD Drives, a division of Parker Hannifin Ltd. WARRANTY

Similar documents
HTTL Speed Feedback Communications Option

8902/E1 Sin/Cos Speed Feedback Option

8902/RE Resolver Speed Feedback Option

8902/E1 Sin/Cos Speed Feedback Option

8903/AI High Resolution Analogue Input Option. 8903/EP Encoder Option

AC10 series NEW FEATURES FRAME 1-5. HA502319U100 Issue 5 Product Manual ENGINEERING YOUR SUCCESS.

8903/PB Profibus Communications Interface

8903/PB Profibus Communications Option

8903/FA FireWire IEEE 1394a Communications Interface

890 Quickstart Manual

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

Operating instructions. Standstill monitor A / / 2011

Line reactors SINAMICS. SINAMICS G130 Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation

Operating instructions. Speed monitor D / / 2014

Zener Barriers Bulletin 937Z

MDM 011-Z1 Regen Resistor

Operating instructions. Switching amplifier DN0210 DN / / 2015

P216. Condenser fan speed controller. Product bulletin. Features

Model P4017 Single Channel USB Oscilloscope. Quick Start Guide

IO-DI8-TO8, IO-DI8-TO8-L I/O Expansion Modules 8 Inputs, 8 Outputs

EX-RC1 Remote I/O Adapter

SINAMICS G130. Terminal Module 150 (TM150) Operating Instructions 03/2013 SINAMICS

IO-AO6X I/O Expansion Module 6 Isolated Analog Outputs

DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies

V E1B Snap-in I/O Module

5521 Potentiometer Analog Input Module

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

High Performance Output Filter Instruction Manual

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

5504 Thermocouple Analog Input Module

V E2B Snap-in I/O Module

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating Instructions 05/2010 SINAMICS

Protection against electric shock

P216 Series Condenser Fan Speed Controller

DriveGuard. Safe-Off Option for PowerFlex 70 AC Drives. User Manual.

This manual was downloaded on (0) TS8000. Firewire Option 8000/FA/00 HA Issue 1

Siemens APOGEE P1 Communications Option

890 Quickstart Manual

USER MANUAL. WBV412U01 AC voltage transducer

High Speed Remote I/O Module

Line reactors SINAMICS. SINAMICS G120P Line reactors. Safety information 1. General. Mechanical installation 3. Electrical installation 4

Operating instructions Evaluation system for flow sensors VS / / 2013

SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS

Two Module Development Kit Installation and User Instructions For Model No. ED-GV15/30

V E2B Snap-in I/O Module

Siemens Industrial s

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. Control Cabinet Inverter MOVITRAC B Functional Safety

Resolver to Digital Expansion Board

SINAMICS. SINAMICS G120P dv/dt filter plus Voltage Peak Limiter. Safety information 1. General. Mechanical installation. Electrical installation 4

Operating Instructions

V E1B Snap-in I/O Module

Line filter SINAMICS. SINAMICS G130 Line filter. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

User Guide. Cloning interface small option module for Unidrive and Commander GP. Part Number: Issue Number: 3

Primary Injection Test Procedure

USER MANUAL. WBI412F41 AC current transducer

Operating Instructions

USER MANUAL. WBI414F21 AC current transducer

When any of the following symbols appear, read the associated information carefully. Symbol Meaning Description

700 Series 200 Amp Clamp Meters

User s Guide. 600A AC Clamp Meter. Model 38387

5401 and 5402 Digital I/O Modules

MTP INSTRUCTION MANUAL

Installation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE

Model 7705 Control Module

PRO-1250D CT MID DIN rail three phase four wire energy meter.

POCKET MULTIMETER Model No: MM18

DM-918 OPERATIONS MANUAL AUTORANGING MULTIMETER

Solar Combiner Enclosure

CVU-200-KIT. 200 V Bias Tee Kit. Description. Parts list / October 2014 *P A* 1

Table of Contents. Safety. Attention. Warnings

8903/CN ControlNet Communications Interface

Multifunctional time delay relay MFT U31S, MFT U41SE

PS/IO Circuit Board Retrofit

MAXIMA+ Series Rotary Level Indicator

CVU-3K-KIT. 3 kv Bias Tee Kit. Description. Parts list / October 2014 *P * 1

Input Frequency: 650 range 50/60Hz 675 range Hz Input Ranges in Amps: Measurement Maximum Inrush

SINAMICS G130. Voltage Sensing Module 10 (VSM10) Operating instructions 03/2011 SINAMICS

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

SMVector Additional I/O Module Installation and Operation Manual

OPERATING AND SERVICE MANUAL. Universal Interface Device 47

Source-Transfer Application Guide

User's Guide. Extech AM A AC Analog Clamp Meter

Kinetix 6000 Axis Module and Shunt Module

Installation Instructions for Eaton Surge Protective Device XXCFXXX10-DIN and XXCFXXX10-DIN2

Digital ac/dc (24V) Input Module

Part No. Z , IA Nov OPERATION MANUAL. High Voltage Digitalmeter A

CM-220 True RMS AC CLAMP METER INSTRUCTION MANUAL

QUINT-BUFFER/24DC/24DC/40

OPERATOR S MANUAL 9000U ISOLATOR

Overview. Applications. Benefits. Ordering Information. Sensors OHD Thermal Guard

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Drive Technology \ Drive Automation \ System Integration \ Services. Manual. MOVITRAC MC07B Functional Safety

Vision OPLC V TR6/V350-J-TR6

Installation Instructions

Instruction manual. Output chokes 690V. Safety information 1. General 2. Mechanical installation 3. Electrical installation 4

METREL test and measurement accessories: 3-phase AktivGT / Machine adapter A1322 Instruction manual Version 1.0, Code no.

Contents. HP E1586A Rack Mount Terminal Panel User s Manual

Installation Instructions

GENERAL PRECAUTIONS GENERAL DESCRIPTION... 6

Transcription:

Technical Manual HA09 Issue 008 Parker SSD Drives, a division of Parker Hannifin Ltd. All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any form or by any means to persons not employed by a Parker SSD Drives company without written permission from Parker SSD Drives, a division of Parker Hannifin Ltd. Although every effort has been taken to ensure the accuracy of this document it may be necessary, without notice, to make amendments or correct omissions. Parker SSD Drives cannot accept responsibility for damage, injury, or expenses resulting therefrom. WARRANTY Parker SSD Drives warrants the goods against defects in design, materials and workmanship for the period of months from the date of manufacture, or months from the date of delivery (whichever is the longer period), on the terms detailed in Parker SSD Drives Standard Conditions of Sale IA000. Parker SSD Drives reserves the right to change the content and product specification without notice. Cont.

FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH, PERSONAL INJURY AND PROPERTY DAMAGE. This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation by users having technical expertise. The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance, maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors. To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems. Cont.

Safety Information! Requirements IMPORTANT: Please read this information BEFORE installing the equipment. Intended Users This manual is to be made available to all persons who are required to install, configure or service equipment described herein, or any other associated operation. The information given is intended to highlight safety issues, EMC considerations, and to enable the user to obtain maximum benefit from the equipment. Complete the following table for future reference detailing how the unit is to be installed and used. Model Number (see product label) INSTALLATION DETAILS Where installed (for your own information) Unit used as a: (refer to Certification for the Inverter) Component Relevant Apparatus Unit fitted: Wall-mounted Enclosure Application Area The equipment described is intended for industrial motor speed control utilising DC motors, AC induction or AC synchronous machines Personnel Installation, operation and maintenance of the equipment should be carried out by qualified personnel. A qualified person is someone who is technically competent and familiar with all safety information and established safety practices; with the installation process, operation and maintenance of this equipment; and with all the hazards involved. Product Warnings Caution Risk of electric shock Caution Refer to documentation Earth/Ground Protective Conductor Terminal Cont.

Hazards DANGER! - Ignoring the following may result in injury. This equipment can endanger life by exposure to rotating machinery and high voltages.. The equipment must be permanently earthed due to the high earth leakage current, and the drive motor must be connected to an appropriate safety earth.. Ensure all incoming supplies are isolated before working on the equipment. Be aware that there may be more than one supply connection to the drive.. There may still be dangerous voltages present at power terminals (motor output, supply input phases, DC bus and the brake, where fitted) when the motor is at standstill or is stopped. Cont. Safety Information!. For measurements use only a meter to IEC 00 (CAT III or higher). Always begin using the highest range. CAT I and CAT II meters must not be used on this product.. Allow at least minutes for the drive's capacitors to discharge to safe voltage levels (<0V). Use the specified meter capable of measuring up to 000V dc & ac rms to confirm that less than 0V is present between all power terminals and earth. 7. Unless otherwise stated, this product must NOT be dismantled. In the event of a fault the drive must be returned. Refer to "Routine Maintenance and Repair". WARNING! - Ignoring the following may result in injury or damage to equipment SAFETY Where there is conflict between EMC and Safety requirements, personnel safety shall always take precedence. Never perform high voltage resistance checks on the wiring without first disconnecting the drive from the circuit being tested. Whilst ensuring ventilation is sufficient, provide guarding and /or additional safety systems to prevent injury or damage to equipment. When replacing a drive in an application and before returning to use, it is essential that all user defined parameters for the product s operation are correctly installed. All control and signal terminals are SELV, i.e. protected by double insulation. Ensure all external wiring is rated for the highest system voltage. Thermal sensors contained within the motor must have at least basic insulation. All exposed metalwork in the Inverter is protected by basic insulation and bonded to a safety earth. RCDs are not recommended for use with this product but, where their use is mandatory, only Type B RCDs should be used. EMC In a domestic environment this product may cause radio This is a product of the restricted sales distribution interference in which case supplementary mitigation class according to IEC 800-. It is designated as measures may be required. professional equipment as defined in This equipment contains electrostatic discharge (ESD) EN000--. Permission of the supply authority sensitive parts. Observe static control precautions shall be obtained before connection to the low when handling, installing and servicing this product. voltage supply. CAUTION! APPLICATION RISK The specifications, processes and circuitry described herein are for guidance only and may need to be adapted to the user s specific application. We can not guarantee the suitability of the equipment described in this Manual for individual applications. RISK ASSESSMENT Under fault conditions, power loss or unintended operating conditions, the drive may not operate as intended. In particular: Stored energy might not discharge to safe levels as The motor's direction of rotation might not be controlled quickly as suggested, and can still be present even The motor speed might not be controlled though the drive appears to be switched off The motor might be energised A drive is a component within a drive system that may influence its operation or effects under a fault condition. Consideration must be given to: Stored energy Supply disconnects Sequencing logic Unintended operation

Contents Contents Page SETPOINT ISOLATORS Functional Diagrams... Mechanical Arrangement... Electrical Installation... Connection Diagrams using 0/07/08 (Cube)... Input Connections... Output Connections (twisted or screened wire recommended)... Speed Cascade or Master/Slave Connection... Cont.

Contents Contents Page Cont.

SETPOINT ISOLATORS Functional Diagrams The Setpoint Isolator has been designed to provide galvanic isolation of input signals from either a voltage or current source. Two isolation channels are provided one digital and one analogue, both rely upon opto isolators to provide galvanic isolation. The digital channel comprises of an opto isolator with a floating output transistor. The analogue channel converts the dc signal level to a frequency proportional to the input level, the variable frequency signal is transmitted via the optoisolator to a amplified decoding circuit. The amplified circuit restores the signal to a variable dc voltage. Due to the limited supply voltage level applied to the output amplifier, the output signal mannot exceed 8V DC. If this proves to be insufficient then a supplementary + to volt supply may be applied to the setpoint isolator to increase the amplifier supply and provide the full +0V output. sw + 7 +0V Current 0V Speed NON-ISOLATED PRODUCT 0V Isolated sw - 8 Run Input Figure DC Channel Isolation Barrier +0V Isolated Setpoint Input V to F Resistor for Current Conversion* V 0V 0 9 Setpoint Output * Current Input Isolator Only Isolation Barrier Figure Analogue Channel

Mechanical Arrangement 99 mm 89 mm 7 mm 7 mm mm 7 8 9 0 8 mm 0 mm mm Figure Mechanical Fixing

Electrical Installation Connection Diagrams using 0/07/08 (Cube) AC Supply FS Voltage Setpoint Isolator 0 9 8 7 ILimit +0V Setpoint Run 0V Tacho 0/07/08 (CUBE) Figure Speed Control AC Supply FS Voltage Setpoint Isolator 0 9 8 7 ILimit +0V Setpoint Run 0V Tacho 0/07/08 (CUBE) Figure Current Control

Input Connections a) 0 to +0V remote signal Terminal - Line 0-0V 0/0Hz AC. Terminal - Neutral. Terminal - Remote isolated signal 0V. Terminal - +0V isolated signal, to enable pot to be used in isolated function (see Figure ). Terminal - Remote isolated signal +0V (maximum). Terminal - Digital run input. b) to 0mA signal Terminal - Terminal Terminal Terminal - } Line 0 to 0V 0/0Hz AC. Terminals - Digital run input. Neutral. Remote isolated signal - 0mA. Isolated Switch/Reset (if required). Output Connections (twisted or screened wire recommended) Output reference signal Terminal 9 Terminal Terminal - - - 0V, connected to follower drive 0V. + 0V, connected to follower drive + 0V. Auxiliary + to V supply signal, adjustable to provide higher output signal Volts. Terminal - Auxiliary supply input + to V dc supply. Control signal reference Terminal 0 - To follower drive speed or current input as required. Switch Output Terminal 7 & 8 - Run switch.

Speed Cascade or Master/Slave Connection By using the isolators, motors may be slaved together either with or without trim pots. Generally one isolator will be sufficient to control two CUBES. AC Supply FS Voltage Setpoint Isolator 0 9 8 7 ILimit +0V Setpoint Run 0V Tacho 0/07/08 (CUBE) ILimit +0V Setpoint Run 0V Tacho 0/07/08 (CUBE) Figure Speed Cascade or Master/Slave Connection Note: A 0%, 0K trim potentiometer may be connected as shown to trim speed on the slaved drive.

ISS. MODIFICATION ECN No. DATE DRAWN CHK'D Initial Issue of HA09 8..9 FEP GDR Manual re-written in Microsoft Word VI Company name change. New Safety information. 080 /0/08 CM GDR FIRST USED ON MODIFICATION RECORD DRAWING NUMBER SHT. ZZ09 OF