Mosaic TM Programme mechanisms multi-support single and multiple sockets: German standard

Similar documents
All two-way switches with indicator have a terminal for neutral connection and have to be equipped with an indicator

Valena Life TM - Valena TM Cat. 6A RJ45 sockets

All two-way switches with indicator have a terminal for neutral connection and have to be equipped with an indicator

Plexo IP 55/IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE. For reference only.

Desk Grommet Number(s) : to 52, to 58, to 63,

NiloéTM. Another timeless classic from Legrand now even easier to install. THE GLOBAL SPECIALIST IN ELECTRICAL AND DIGITAL BUILDING INFRASTRUCTURES

Plexo IP 55/IP 66 Makes your day, rain or shine

Suno TM switches, push-buttons, dimmers, roller blind controls

Niloé. Getting it just right

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding

BRITISH STANDARD WIRING ACCESSORIES NEW PRODUCTS Synergy. Sleek Design equipped mechanisms (p. 560 to 564)

P ROT EC TA S E RIE S. IP66 weatherproof control devices & sockets to safeguard home and family

PROTECTA Series IP66 weatherproof switches & sockets to safeguard home and family

Mureva Assembly surface mounted wiring devices

ECO 60 RANGE INTERNATIONAL DOMESTIC RANGE

resistance for high requirement

Pop-Up Number(s) : to 03, to 08, to 13,


alena switc es Switches 10 AX VA - IP 44 Mechanisms supplied with cover plates, to be equipped with plates (p ) Screw or claw mounting

Workstation Solutions

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

Solid as a rock Soliroc

Workstation Solutions

WIRING ACCESSORIES NEW PRODUCTS. Mallia TM complete white. Mallia TM customisable colours. Belanko TM. Plexo, Industrial sockets

ADJUSTABLE FLOOR BOXES

Pop-Up Floor Number(s) : à à à

Mosaic TM LCS2 Cat. 6 RJ 45 socket

Vimark. t: e: w: detaelectrical.co.uk

Mosaic TM LCS2 Cat. 6 RJ 45 socket

Product Manual ASL Document Ref.: U doc Issue: 04 complete, approved - Date: 16/08/10 Part Number: M0618_23

Installation Guide. Universal Camera Mount Bracket

Surface-Mounting Product Ranges

The right solution for every home

Niloé. Getting it just right. Traditional and wireless ZigBee solution

NATIONAL DEVICES. Modular Design Receptacles, Switches, Pilot Lights. (45 mm)... Page 46

Installation Guide Mounting Kit for Mounting Philips Avalon CTS Cordless Fetal Transducer System on Wall, 2'' Post, Rail, or Slide-on Mounting Plate

Chroma Plus 130 decorative High quality, lustrous finish with modern curved design Total safety

COMMERCIAL BUILDING SYSTEMS & DATA

WINSTA. Full Line Catalog 2008/2009

Weathersafe Vision. Installation & Operating Instructions

Product and functional description

Ergonomic Electrical Accessories

topter SERIES ACTIVE PROTECTION Leading Electrotechnology

T E C H N I C A L C A T A L O G U E

Plugs & sockets. Industrial plugs and sockets - Scame I-1 4. Industrial switched sockets - Scame I-4 5. Distribution assemblies - Scame I-6

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Mallia. Express Yourself Like Never Before

4.5 Components for TV/SAT, telephone installations and Category DATATEL Series - TEL DATATEL Series - CAT5 DATATEL Series - TV/SAT

Product and functional description

Installation Guide Philips MP20/30/40/50/60/70 IntelliVue M-Series Arm Rail Mount Kit

Alloy. technical hotline +44 (0) decorative wiring devices

SHALLOW FLOOR BOXES.

InForm Superstructures

TELEBLOCK CONTENTS: Descriptions Characteristics Applications Installation Product specifications Compatibilities

GCX Mounting Assembly Operation/Installation Manual Dräger Model Primus with Siemens 6002/7000/9000XL Patient Monitors

5 imple reasons to switch

SHALLOW FLOOR BOXES. Description Applications

Ergonomic Electrical Accessories

LOW VOLTAGE DEVICES PLUGS AND CONNECTORS

Product and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs

Installation Guide Philips MP60/70 IntelliVue VHM Arm Rail Mount Kit

isolating transformers of The new Generation

LCS² Cat. 6A RJ45 Socket

Lighting control for commercial buildings

Classification Enclosure rating Input voltage Type of

IT power distribution Power distribution units (PDU) Basic. Versions available:

Product and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005

Installing Sentor. Hardware Installation

Mobile sockets & plugs

2 Mesa Ethernet Dock User s Manual

Kalo Attraction in simplicity

DCS Infrared Transmitter. User Manual. Digital Conference System. Danish Interpretation Systems

to modern interiors. As trends in contemporary décor increasingly include the use of chrome

Electrical Actuators

Electromotoric actuators

FLUSH MOUNTING DEVICES

Electrical Actuators

Rivia Your Everyday Choice! Legrand Rivia.indd 1 25/06/12 10:34

PHOENIX CONTACT - 07/2006

Exiway One LED Technical specifications Activa and Dardo versions

ISDN 8510T Voice Terminal Instructions for Changing the EPROM

Charging Cabinet Owner s Manual

The purpose of this guide is to describe mounting of FMS, docking station, external alert device or Hotspot in channel.

Linear Luminaire with LED Series 6012/5

Indicator, round, raised, full face with plastic matt chrome bezel, 22.5 mm mounting, lamp block included. Yellow Green

Slimline. Technical Hotline

Tools required 1/8 hex wrench (provided) Phillips Screwdriver (not provided) Mounting the FMS in a Channel

Horizontal distribution busbar HX 3 80/125 A plug-in

LinkStation MINI QUICK REFERENCE GUIDE

ELECTRICAL WIRING ACCESSORIES

Product and functional description

Myrius TM mechanisms - white

Wiring diagrams for luminous 1P 1-way switches with 110 V~ or 250 V~ signalling units

Ripac VME/VME64x Systems. Applications. Design Features

Series Single and double-pole rocker switches

BLUETOOTH SPEAKER GSB 2000

MAGIXBOX TM. Quick Start Guide

To connect the AC adapter:

User Manual LKS-CD17DR LKS-CD19DR. 17 LCD Dual Rail Console Drawer with Modular KVM Switch. 19 LCD Dual Rail Console Drawer with Modular KVM Switch

Electrical Interconnection

Transcription:

Mosaic TM Programme mechanisms multi-support single and multiple sockets: German standard Automatic terminals 0 77 17 0 77 31 0 77 19 0 77 5 Sockets for snap-on trunking p. 798 Sockets for DP trunking p. 819 Selection chart for boxes, supports and plates p. 88-883 Pack Cat.os Multi-support single sockets - German standard For installation in flush-mounting box, surfacemounting box, floor box, column module, desktop multi-outlet extension, office module and trunking P+E with shutters for child protection 10 0 77 11 White - automatic terminals 10 0 77 13 White - with special tap-off screw and 4 mm screw terminals 10 0 77 18 Red - automatic terminals 10 0 79 13 Alu - screw terminals 10 0 787 0 White antimicrobial - screw terminals 10 0 77 16 Green antimicrobial - automatic terminals 10 0 77 17 Orange antimicrobial - automatic terminals 10 0 77 0 Red antimicrobial - screw terminals P+E without child protection 10 0 77 10 White - screw terminals P+E angled 45 10 0 77 45 White - automatic terminals P+E tamperproof 10 0 77 14 Red - screw terminals To be used with the tamperproof insert Cat.o 0 50 99 P+E "Access Design" Special for disabled persons Simple action on the lever allows easy plug-in or unplug 1 0 77 31 White antimicrobial Pack Cat.os Multi-support multiple sockets - German standard For installation in flush-mounting box, surfacemounting box, floor box, column module, desktop multi-outlet extension and office module Inclined 45 Connection by automatic terminals x P+E 10 0 77 5 White 10 0 77 90 White - with indicator 30 V -.4 ma (supplied) 10 0 79 8 Alu 10 0 77 7 Red 10 0 77 91 Red - with indicator 30 V -.4 ma (supplied) 10 0 77 81 Red - tamperproof. To be used with tamperproof insert Cat.o 0 50 99 10 0 77 9 Red - tamperproof, with indicator 30 V -.4 ma (supplied). To be used with tamperproof insert Cat.o 0 50 99 3 x P+E 10 0 77 53 White 10 0 79 83 Alu 10 0 77 8 Red 10 0 77 73 Red - tamperproof. To be used with tamperproof insert Cat.o 0 50 99 4 x P+E 10 0 77 54 White 10 0 77 83 Red 10 0 77 74 Red - tamperproof. To be used with tamperproof insert Cat.o 0 50 99 Tamperproof insert 10 0 50 99 Tamperproof insert for socket Fits directly into the plug P+E with cover 10 0 77 19 White antimicrobial - automatic terminals P+E with indicator 10 0 77 1 White antimicrobial - automatic terminals Indicator 30 V -.4 ma supplied 866 Red catalogue numbers: ew products

Mosaic TM Programme mechanisms international standards socket outlets Mosaic TM Programme mechanisms USB sockets for charging EW 0 775 0 0 775 04 0 775 05 0 775 94 0 775 91 0 793 93 Selection chart for supports and plates p. 88-883 0 775 06 0 770 80 Average charging time for devices equipped with lithium-ion polymer batteries: - 80% charged < h - 100% charged < 4h o specific constraint: no need to wait for the battery to be flat before charging it, or to have it fully charged before use Selection chart for boxes, supports and plates p. 88-883 Pack Cat.os Other standard socket outlets Euro-US standard - white 10 0 775 01 10 0 775 0 US standard - white 10 0 775 03 10 0 775 04-15 A British standard - white 10 0 775 05-13 A Italian type - white 10 0 775 10-10 A - screw terminals 10 0 775 11-10/16 A - screw terminals 10 0 775 1-16 A - screw terminals Swiss type - white 10 0 775 06 - type 13 EW Danish standard - white 10 0 775 08 - with shutters for child protection 10 0 775 09 - for UPS - with shutters for child protection P EV socket outlet With shutters for child protection For installation in flush-mounting box, surfacemounting box, floor box, column module, desktop multi-outlet extension, office module and trunking 10 0 771 50 - white antimicrobial Pack Cat.os USB power supplies For recharging portable devices Conform to IEC 6684-011-01 Consumption in passive mode < 0.3 W P+E tap-off connection via.5 mm screw terminals Supplied cordless Double USB sockets - 5V- 1500 ma For telephones, smartphones, MP3/MP4 players and fast-charging tablet PC 5 0 775 94 White 1 0 793 94 Alu January 014 Single USB sockets - 5V - 750 ma For telephones and smartphones 10 0 775 91 White 1 0 793 91 Alu USB power supplies with retractable cord For recharging portable devices such as telephones and smartphones Single socket 5 V - 750 ma equipped with a retractable cord with micro USB connector Conform to IEC 6684-011-01 Consumption in passive mode < 0.3 W P+E tap-off connection via.5 mm screw terminals Cord length : 0.3 m 10 0 775 93 White 10 0 793 93 Alu January 014 Support for portable device on charge Prevents device from any fall risk and allows secure use of device while charging Wall-mounting Fixing tools supplied 1 0 803 99 For 1 portable device Supplied with a mobile retractable cord Anti-extraction module When used with a socket, avoids accidental unplugging of sensitive electrical equipment, by gripping the cord (Ø4 to 8 mm cords) Can withstand an extraction force of 350 (35 kgs) 1 0 770 80 - white antimicrobial Red catalogue numbers: ew products 867

Mosaic TM Programme mechanisms switches pull-cord switches and ventilation control 0 79 01 0 79 11 0 770 0 0 79 1 0 770 14 Selection chart for boxes, supports and plates p. 88-883 All es with indicator have a terminal for neutral connection and have to be equipped with an indicator Pack Cat.os One-way switches - 50 V± Fast connection via automatic terminals, no tool required 10 0 770 00 White 10 0 770 10 White Two-way switches - 50 V± Fast connection via automatic terminals, no tool required 10 0 770 01 White 10 0 79 01 Alu 10 0 787 10 White antimicrobial 10 0 770 11 White 10 0 79 11 Alu 10 0 787 11 White antimicrobial with ED indicator 10 0 770 0 White 10 0 79 0 Alu with ED indicator 10 0 770 1 White 10 0 79 1 Alu 10 0 787 1 White antimicrobial intermediate switch 10 0 770 1 White 10 0 79 1 Alu Pack Cat.os Two-way switches 0 AX - 50 V± Screw terminals 10 0 770 60 White with ED indicator 10 0 770 6 White EW - -pole 10 0 770 63 White EW - -pole with ED indicator 10 0 770 64 White -pole one-way switches 10 0 770 50 White with ED indicator 10 0 770 5 White Pull-cord switches Fast connection via automatic terminals, no tool required Two-way switch, - For controlling 30 V± incandescent and halogen lamps up to 300 W 1 0 770 14 White Two-way switches 16 AX - 50 V± Screw terminals 10 0 770 91 White finish 10 0 770 93 White finish with ED indicator 10 0 770 9 White finish 10 0 770 94 White finish with ED indicator Two-way pushbutton - 6 A, with pull cord 1 0 770 44 White Cord for pull mechanism 10 0 898 05 ength 1.5 m Ventilation control Fast connection via automatic terminals, no tool required Two-way switch For direct control of controlled mechanical ventilation - 50 V± 1 0 770 7 White antimicrobial 856

for Mosaic example TM Programme xxxxxxx socket outlets xxxxxxxx Mosaic socket outlet Cat.o 0 774 0 with 4 modules support Mosaic RJ 45 socket outlet with support Cat.o 0 109 54 Mosaic socket outlet Cat.o 0 774 03 with 6 modules support Mosaic socket outlet Cat.o 0 774 3 with 4 modules support Mosaic x 4 modules support Cat.o 0 109 54 for cover width 65 mm Pack Cat.os Sockets for installation on DP trunking Mosaic sockets with shutters with connection at both sides for mounting on 65 and 85 mm cover DP trunking in conjunction with supports and plates for trunking (see p. 804-805) Direct connection requiring no tools, intuitive disconnection without dismantling T the support Standard Tamperproof Automatic terminals - German standard 10 0 774 01 0 774 1 P+E 10 0 774 0 0 774 x P+E 10 0 774 03 0 774 3 3 x P+E 5 0 774 04 0 774 4 4 x P+E Red 10 0 774 11 P+E Pack Cat.os Sockets for installation on DP trunking (continued) T Standard Tamperproof Screw terminals - German standard 10 0 776 01 0 776 1 P+E 10 0 776 0 0 776 x P+E 10 0 776 03 0 776 3 3 x P+E 5 0 776 04 0 776 4 4 x P+E Red 10 0 776 11 P+E 10 0 776 1 x P+E 10 0 776 13 3 x P+E 5 0 776 14 4 x P+E 10 0 774 1 x P+E 10 0 774 13 3 x P+E 5 0 774 14 4 x P+E Tamperproof insert 10 0 50 99 Tamperproof insert for socket Fits directly into the plug Red catalogue numbers: ew products 819

87045 IMOGES Cedex Telephone: (+33) 05 55 06 87 87 - Fax: (+33) 05 55 06 88 88 Mosaic TM switches Cat. os.: 770 00/01/0/10/11/1/14/1/7 79 01/0/11/1/1 COTETS Page 770 11 770 1-79 1 770 7 1. Use....1. Range....1 3. Preparation.... 1-4. Overall dimensions.... 5. Connection... -3 6. Operation...3 7. Technical characteristics...3 8. Cleaning...3 9. Accessories...3 10. Conformity - Approvals....3 1. USE General lighting control mechanisms with or without signalling components (indicator light).. RAGE Designation Cat. o. o. of modules Connection method Weight (g) Characteristics 3. PREPARATIO Modular mounting of the mechanisms using adapter Cat. o. 80 99 (). The mechanisms are mounted on thin walls using adapters Cat. o. 80 90 (), Cat. o. 80 91 (), Cat. o. 80 9 ( x 1 vertical module). The mechanisms can be flush-mounted or surface-mounted. 3.1 General preparation Switch 770 00* 17.00 1 automatic 770 01 17.60 50 VA, with indicator light 770 0 1 automatic. 18.79 50 VA Switch 770 10* 0.00 automatic 770 11 1.81 50 VA CICK CICK with indicator light with aluminium with indicator light and aluminium with aluminium with indicator light and aluminium with CMV contrrol with pull cord 770 1 automatic 3.00 50 VA 79 01 1 automatic 17.60 50 VA 79 0 1 automatic 18.79 50 VA 79 11 automatic 1.81 50 VA 79 1 automatic 3.00 50 VA 770 7 automatic 1.81 50 VA 770 14 automatic 6.74 50 VA 3. Preparation of indicator light for Cat. o. 770 14 1 - Break the tabs - Insert the mechanism on the indicator light 3 - Clip the whole into the support 4 - Position the cover. intermediate switch 770 1 with screws 4.00 50 VA intermediate switch with aluminium 79 1 with screws 4.00 50 VA *Only terminals Technical data sheet: F00414E/04 Updated: 14/10/011 Created: 5/09/007 COTETS 1/3

Mosaic TM switches 3. PREPARATIO (continued) 3.3 Precaution for use for Cat. o. 770 14 Cat. os.: 770 00/01/0/10/11/1/14/1/7 79 01/0/11/1/1 5. COECTIO Terminals Capacity Stripping Screwdriver 770 00 770 01 770 0 770 10 770 11 770 1 79 01 79 0 79 11 79 1 770 7 770 14 automatic x.5 mm Stripping guide 13 mm 0 maxi 0 maxi 0 maxi 770 1 79 1 with screws x.5 mm Stripping guide 10 mm Philips 1 Posidrive 1 Flat-blade 4 mm 4. OVERA DIMESIOS 5.1 Wiring Cat. os.: 770 0/1 79 0/1 Illuminated function: Illuminates the switch in the dark..5 45.5.6 18 770 00/01/0 79 01/0 45 18 770 10/11/1/7 79 11/1 1 - Unclip the rocker - Insert the indicator light Cat. o. 676 66 or the indicator light Cat 676 67 1 34,9 switch 1 1 45.1 45.1 43.7 31.5 Indicator function: The lamp is switched on when the lighting is on. 40.3 770 1-79 1 45 45 3 1 - Unclip the rocker - Insert the indicator light Cat. o. 676 68.6 4 18 770 14 Technical data sheet: F00414E/04 Updated: 14/10/011 Created: 5/09/007 COTETS /3

Mosaic TM switches 5. COECTIO (continued) Indicator function or illuminated function, use the indicator light Cat. o. 676 69 1-4 V, indicator light Cat. o. 667 61, d.c.: 0. ma; a.c.: 0.4 ma. 4-48 V, indicator light Cat. o. 667 6, d.c.: 0.9 ma; a.c.: 1. ma. 30 V, indicator light Cat. o. 667 69 a.c.: 0.15 to 3 ma. switch 1 1 1 Cat. os. 770 14 Indicator function or illuminated function, use the indicator light Cat. o. 676 69 1-4 V, indicator light Cat. o. 667 61, d.c.: 0. ma; a.c.: 0.4 ma. 4-48 V, indicator light Cat. o. 667 6, d.c.: 0.9 ma; a.c.: 1. ma. 30 V, indicator light Cat. o. 667 69 a.c.: 0.15 to 3 ma. 676 69 AAWSS 30V Position Position Indicator Illuminated 3mA 0,15mA Cat. os.: 770 00/01/0/10/11/1/14/1/7 79 01/0/11/1/1 6. OPERATIO Switching mechanism (handling force.6 to 3.5 ): Cat. os 770 00/01/0/10/11/1/1 79 0/11/1 Pull-cord mechanism (handling force 3 to 5 ) : Cat. o. 770 14 7. TECHICA CHARACTERISTICS 7.1 Mechanical characteristics Impact tests: IK04 Protection against liquids: IP31 (C15100) 7. Material characteristics Rocker: ABS (RA 9003) Base: Polycarbonate Rocker support: Polycarbonate 7.3 Electrical characteristics Self-extinguishing: 650 C / 30 s Voltage: 50 V Current: 7.4 Climatic characteristics Storage temperatures: - 10 C to + 70 C Operating temperatures: - 5 C to + 50 C 8. CEAIG Surface cleaning with a cloth. Do not use: acetone, tar remover, trichloroethylene. 8.1 Resistance to cleaning agents Resistance to the following agents: Hexane (E 60669-1), methylated spirits, soapy water, diluted ammonia, pure bleach diluted 10%, glass cleaning substance, pre-impregnated wipes. 8. Resistance to hospital-type cleaning agents Resistance to the following agents : Anios, Surfanios, Bactilysine, Diluted hydrogen peroxide (35%). Caution: A preliminary test should be carried out if other specific cleaning products are to be used. Cat. os. 770 1-79 1 connection via automatic terminals without release keys 9. ACCESSORIES ights for switches with indicator light Switches Illuminated Indicator 4 770 0 770 1 79 0 79 1 676 66 (30 V) 676 67 (1-4-48 V) 676 68 (30 V) 676 69 (30 V / 0,15mA) 676 69 (30 V / 0.3 ma) 1 3 770 14 676 61 (1/4 V) 676 6 (4/48 V) Cord for two-way pull-cord switch 770 14 898 05 Cordon 1.5 m 10. COFORMITY - APPROVAS Approvals in process: F - CEBEC - BBJ - EZU - VDE - OVE - AEOR - KEMA - MEEI - GOST - TSE. Technical data sheet: F00414E/04 Updated: 14/10/011 Created: 5/09/007 COTETS 3/3

18, av. du Maréchal-de-attre-de-Tassigny - 87045 IMOGES Cedex Tel : 0 (+33) 5 55 06 87 87 Fax : 0 (+33) 5 55 06 88 88 www.legrand.com Mosaic tm Socket outlets to Schuko standard Cat. o(s): 0 77 13/14/18/45-0 79 13 0 77 13 0 77 14 1. USE Socket outlet 16 A - 50 V~ to Schuko standard.. RAGE Designation Cat. o. Finishes Socket P+E special 4 mm and tapping 4.OVERA DIMESIOS 0 77 13 White 0 79 13 Aluminium br of modules Connection method with screws Socket P+E 0 77 14 with screws Tamperproof Red Socket P+E 0 77 18 automatic Prise P+T 45 inclined 0 77 45 White automatic D E 6. TECHICA CHARACTERISTICS 6.1 Mechanical characteristics Impact tests: IK 04 Protection against solid bodies / liquids: IP 0 6. Material characteristics Base: Polycarbonate Cover plate: Polycarbonate 6.3 Climatic characteristics Self-extinguishing: 650 C / 30 s Storage temperatures: - 10 C to + 70 C Operating temperatures: - 5 C to + 50 C 7. CEAIG Surface cleaning with a cloth. Do not use: acetone, tar remover, trichloroethylene. 7.1 Resistance to cleaning agents Resistance to the following agents: Hexane (E 60669-1), Methylated spirits, Soapy water, Diluted ammonia, Diluted pure bleach 10%, Glass cleaning substance, Pre-impregnated wipes. 7. Resistance to hospital-type cleaning agents Resistance to the following agents: Anios, Surfanios, Bactilysine, Diluted hydrogen peroxide (35%). C B F Caution: A preliminary test should be carried out if other specific cleaning products are to be used. A A B C D E F 40.3 31.5 40 8.5 45 45 8. ACCESSORIES Tamperproof insert Cat. o. 0 50 99 for tamperproof socket outlet Cat. o. 0 77 14. 5. COECTIO Connection method with screws automatic Capacity x 4 mm x.5 mm Stripping length 10 mm 13 mm Type of screwdriver to use: Flat-blade 4 mm Technical data sheet: F0043E/03 Updated: 6/10/01 Created: 01/1/006 1/1