TYPE APPROVAL CERTIFICATE

Similar documents
TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

PPM Protection and Power Management DATA SHEET

Generator Protection Unit, GPU Hydro Multi-line A SW version 2.4X.X

AGC 200 Advanced Gen-set Controller DATA SHEET

General introduction Part 2, chapter 11

DEIF A/S. Generator Paralleling Controller multi-line L. Type GPC / GS. Compact system in one unit

Engine & Genset Controls Z, page 1 of 12

MULTI-LINE 2 APPLICATION NOTES. Converting PPU-2 to PPU-3 Parameter conversion Wiring Options I/O list. Document no.: A SW version:

Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL.

Engines & Gen-sets N, page 1 of 6

Generator Protection Unit, GPU-3 DATA SHEET

Basic Gen-set Controller multi-line F SW version 2.31.X or later

Generator Protection Unit, GPU-3 DATA SHEET

Automatic Gen-set Controller Multi-line D

SPARE PART ONLY. Basic Gen-set Controller Multi-line H SW version 2.31.X or later. Data sheet. Standard functions

SIGMA. Advanced Generator Protection and Control. Short Form Catalogue

DATA SHEET Automatic Genset Controller, AGC-3

Generator Paralleling Controller, GPC-3 DATA SHEET

Option H3 Serial communication Profibus DP

GC2000 Generator Controller Power Management and Protection

DEIF A/S. Description of options. Option C1 Generator add-on protection package Multi-line 2 version 2. Description of options. Functional description

PPU Power Management (PPM)

DEIF A/S. Description of options. Option A and B, Loss of mains protection package Automatic Gen-set controller. Description of options

Compact Genset Controller, CGC 400 Generator control and protection Engine monitoring and protection Generator and mains breaker control RS485 Modbus

AGC 200 Automatic Advanced Gen-set Controller DATA SHEET

Delomatic 4, DM-4 Marine & Offshore DATA SHEET

Generator Protection Unit, GPU-3 Gas Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

DATA SHEET Paralleling and Protection Unit, PPU-3

MULTI-LINE 2 APPLICATION NOTES

MARINE & OFFSHORE SHIP ENERGY MONITORING SYSTEM

Delomatic 4, DM-4 Land DATA SHEET

EC-TYPE EXAMINATION CERTIFICATE (MODULE B)

Generator Paralleling Controller, GPC-3 Gas Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

OPERATOR'S MANUAL Generator Paralleling Controller, GPC-3 - Generator Protection Unit, GPU-3/GPU-3 Hydro - Paralleling and Protection Unit, PPU-3

AGC 200 Advanced Gen-set Controller What s in the delivery? Getting started The first steps Using the AGC 200

Generator Paralleling Controller, GPC-3 Regulation modes Generator protection (ANSI) M-Logic (Micro PLC) Busbar protection (ANSI) Display General

QUICK START GUIDE Generator Paralleling Controller, GPC-3 Generator Protection Unit, GPU-3/GPU-3 Hydro Paralleling and Protection Unit, PPU-3

APPLICATION NOTES H-coupling

Generator Protection Unit, GPU-3 Generator protection (ANSI) Busbar protection (ANSI) M-Logic (Micro PLC) Display General

Advanced Genset Controller, AGC 200 Operation modes Display and unit front General Engine control M-Logic Optional applications

DEIF A/S. Description of options. Option P1, Event and alarm printer Automatic Gen-set Controller. Description of option. Functional description

M-Logic Internal Logic Controller Description of M-Logic Functional description List of possible selections for logics

EC-TYPE EXAMINATION CERTIFICATE (MODULE B)

QUICK START GUIDE Paralleling and Protection Unit PPU 300

MULTI-LINE 2 APPLICATION NOTES. Converting PPM-2 to PPM-3 Parameter conversion Wiring Options I/O list Modbus. Document no.: A SW version:

Genset control and protection with safety system

DATA SHEET Compact Genset Controller, CGC 200

NOT RECOMMENDED FOR NEW DESIGNS

Option P1 Event and alarm printer Description of option Functional description Parameter list

HT-DST4602 Evolution. Genset Controller. AMF and PARALLEL genset controller. Parallel Applications HUEGLI TECH SWITZERLAND

QUICK START GUIDE Generator Protection Unit GPU 300

Generator Controller GC-1F

QUICK START GUIDE Paralleling and Protection Unit PPU 300

DEIF A/S. Description of options. Option C2, Generator add-on protection package Automatic Gen-set Controller. Description of option

GPM500 Generator Protection Module

DATA SHEET Automatic Genset Controller, AGC-4

DATA SHEET Genset Controller, GC-1F

Installation Manual. Multi Power Controller MPC-1 multi-line D

Automatic Genset Controller, AGC-3 What's in the delivery Getting started The first steps Using the AGC

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

(1986; Rev. 1989) Molded Case Circuit Breakers and Molded Case Switches. (1985; Rev. 1988) Enclosures for Electrical Equipment (1000 Volts Maximum)

Multiple Generator Automatic Synchronising System

Generator Controller GC-1

MIC-2 Multi-instrument DATA SHEET

Option M2 Configurable engine control cards Multi-line 2 version B SW version 2.4X.X

Automatic Genset Controller, AGC-4 What s in the delivery? Getting started The first steps Using the AGC

Option H8.x and H12.x External I/O modules Description of option Functional description

TYPE APPROVAL CERTIFICATE

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

No longer for sale. Generator Controller GC-1. Data sheet. Standard functions

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

Engine Controller EC-1

MIC-2 MKII, Multi-instrument DATA SHEET

1510 MOTOR CONTROLLERS

DATA SHEET. AGC PM Automatic Genset Controller, Plant Management

Data Network Guidelines for Ships

INSTALLATION INSTRUCTIONS

paralleling SOLUTIONS

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

SECTION TRANSIENT VOLTAGE SUPPRESSION FOR LOW-VOLTAGE ELECTRICAL POWER CIRCUITS

Substation Automation Products. Bay control REC670/650 Relion 670 and 650 series

An Urgent Bulletin from CSA Group

Compact Genset Controller, CGC 400 What's in the delivery? The first steps Push-buttons and LEDs

Basic Gen-set Controller G (UK) SW version 2.1X.X. Terminal strip overview

e 2 TANGO -400 Overcurrent Relay K Catalogue EN

Power Meter PowerMonitor 500

Power Control Systems

INSTALLATION INSTRUCTIONS

DELOMATIC - MULTI-FUNCTION SYSTEM PART 2 INSTALLATION INSTRUCTION

1. Project Description

SECTION ENCLOSED SWITCHES AND CIRCUIT BREAKERS

SECTION ( ) LIGHTING CONTROL PANELBOARD

Transcription:

TYPE APPROVAL CERTIFICATE Certificate No: TAA00000KD Revision No: 1 This is to certify: That the Electrical Measuring and Protection Relay with type designation(s) PPU-3, GPU-3 - Generator Controllers and Protection, PPM-3 - Power Management System Issued to DEIF A/S Skive, Midtjylland, Denmark is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft Application : Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL. Location classes: Temperature B Humidity B Vibration A EMC A/B** Enclosure B* * for display and operation panels only, for the main modules required protection according to the Rules to be provided upon installation on board **EMC Class B for Displays DU-2, AOP1, AOP2 Issued at Høvik on 2018-11-05 This Certificate is valid until 2020-11-13. DNV GL local station: Aalborg Approval Engineer: Bartosz Kabak for DNV GL Jan Tore Grimsrud Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 1 of 6 DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.

Product description The unit is based on a compact all-in-one design which includes an LCD HMI panel that can be mounted directly on top of the base unit or in the front of e.g. a switchboard door. Two additional such displays can be installed within 200m distance of the main display unit. Additional operator panels (AOP) with 16 LEDs and 8 pushbuttons can be installed, one locally within 0.5m (AOP-1) and five within 200m (AOP-2). The units are designed for the following applications: Generator Protection Unit (GPU-3) combines the following functions: Generator and busbar protection Engine control and protection Synchronisation AC metering Paralleling and Protection Unit (PPU-3) has the following additional functions (Regulation modes): Loadsharing (via analogue or CANbus link) Fixed Power Fixed Frequency Frequency droop Protection and Power Management system (PPM-3) may include control and monitoring of: Multiple gen-sets Shaft generators and shore connection Busbars and bustie breakers Emergency generators A PPM-3 system includes the following basic functions: All breakers can be synchronised by choice Load-dependent start/stop operation Priority selection of gen-sets Redundant communication between the controllers Plant divided into sections for individual functionality Load transfer Heavy consumer management Multi-master system for the following applications: Diesel generator operation Shaft generator operation Shore connection operation Split busbar(s) operation Emergency/harbour generator operation There are several additional functions available as options. Reference is made to the manufacturer's documentation. The following alarm and protection functions as defined by ANSI are available: ANSI no. Function / description PPM-3 PPU-3, GPU-3 27 Undervoltage X X 27 Positive sequence (mains voltage low) X 27Q Reactive power dependent undervoltage X 27T Time dependent undervoltage X 32 Overload/Reverse Power X X 40 Loss of excitation/overexcitation X X 40 Power dependent reactive power import/export X Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 2 of 6

ANSI no. Function / description PPM-3 PPU-3, GPU-3 46 Negative sequence current high X 47 Negative sequence voltage high X 50/51 Overcurrent X X 50 Zero sequence current high X 51 Inverse timer overcurrent X 51V Voltage-dependent overcurrent X X 59 Overvoltage X X 59 Zero sequence voltage high X 60 Current/Voltage unbalance X X 67 Directional overcurrent X 78 Vector jump X 81 Over/Underfrequency X X 81R df/dt (ROCOF) X The same software is installed in all units. Project specific functions are achieved by setting limits for alarms and parameters. The software are identified by the following versions: PPM-3 PPU-3, GPU-3 Appl. SW 3.0x.x 3.1x.x M4 board SW 2.0x.x 2.0x.x Further details about the system may be found at DEIF s homepage on the Internet: http://www.deif.com Approval conditions The Type Approval covers hardware and software listed under Product description. When the type approved software is revised (affecting all future deliveries) DNV GL is to be informed by forwarding updated software version documentation. If the changes are judged to affect functionality for which rule requirements apply a new functional type test may be required and the certificate may have to be renewed to identify the new software version. Case-by-case: For each delivery where the product is included (typically a switchboard) the following information related to the application system is to be submitted for approval: - Reference to this Type Approval Certificate - System block diagram - Power supply arrangement (may be part of the System block diagram) - List of hardware and software modules as identified in this Type Approval Certificate - Functional description including functions provided through AOP(s) if applicable - List of implemented alarm and protection functions (ref. the ANSI list above) with proposed limits and time delays - Test program for the certification test (non-standard PPM-3) or commissioning tests (PPU-3/GPU- 3/standard PPM-3) Product certificate For a PPU-3, GPU-3 or a standard PPM-3 system (DNV GL approved) delivery: as long as the delivered system is covered by this Type Approval, a product certificate according to Pt.4 Ch.9 Sec.1 [1.2.3] is not required. Correct configuration and set up for the delivery to be tested during commissioning after installation onboard. Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 3 of 6

For non-standard PPM-3 systems: each system to be certified according to Pt.4 Ch.9 Sec.1. The certification test is to be performed before the system is installed onboard at the company defined as responsible for the system, typically at the switchboard manufacturer. The product certificate must identify this Type Approval Certificate and the parameter settings for the specific project. After the certification the clause for application software control will be in force: Clause for application software control All changes in software and parameter settings are to be recorded as long as the system is in use on board. The records of all changes are to be forwarded to DNV GL for evaluation and approval. Major changes in the software are to be approved before being installed in the controller(s). Application/Limitation Rule requirements for separate prime mover safety functions are to be observed. In case the optional M4 board is fitted to perform these functions the safety stop circuit is to be independent of the normal stop circuit, e.g. separate stop coils are to be arranged. For high speed vessels category B (ref. Pt.4 Ch.8 Sec.2 [6.1]) the PPM-3 system must be configured so as to ensure that the power management functions are active for each busbar section when the bustie breaker is open. Also, the communication network between DGUs for one busbar section must not be affected by a defective communication network for the other busbar section. Type Approval documentation Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 4 of 6

Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 5 of 6

Tests carried out Applicable tests according to Standard for Certification No. 2.4, April 2006. Functional Type Tests on a representative system (4 diesel generators, one shaft generator, one emergency generator/bus, one bustie breaker, one shore connection) at DEIF s test bench during 2007.05.19-20. Functional Type Tests for two of four standard PPM-3 systems, 2xDG-BTB-SG/SC and 4xDG-BTB at DEIF s test bench on 2010-10-07 Periodical assessment The scope of the periodical assessment is to verify that the conditions stipulated for the type are complied with, and that no alterations are made to the product design or choice of systems, software versions, components and/or materials. The main elements of the assessment are: Ensure that type approved documentation is available Inspection of factory samples, selected at random from the production line (where practicable) Review of production and inspection routines, including test records from product sample tests and control routines Ensuring that systems, software versions, components and/or materials used comply with type approved documents and/or referenced system, software, component and material specifications Review of possible changes in design of systems, software versions, components, materials and/or performance, and make sure that such changes do not affect the type approval given Ensuring traceability between manufacturer s product type marking and the type approval certificate A renewal assessment will be performed at renewal of the certificate. END OF CERTIFICATE Form code: TA 251 Revision: 2016-12 www.dnvgl.com Page 6 of 6