German Cathodic Protection

Similar documents
Weilekes Elektronik GmbH Am Luftschacht Gelsenkirchen Germany Tel: Fax:

BAC GLOBAL SURVEYOR Mk

Gx TIME CHART RECORDER APPLICATION (Catalog # SFT133) USER S MANUAL

NaMobil 3.0. MoData2 - Software for Maintenance. Manual

Visit to download the software Digalox Manager. Package contents: Panel meter Digalox DPM72, 5 jumpers, 1 mounting bracket

DX4085 Z-Meter Tester

Data Acquisition & Signal Conditioning Units

Innovation in Magnetic Measuring Instruments. Data Acquisition & Conditioning Units

ECG MACHINES. Kizlon Medical. Website:

DIAGNOSTICS PN# / / FSP

User Manual INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

vlocdm2 Rx & Loc-150Tx Data Sheet V1.6

EL-USB-ACT AC and DC Millivolt Data Logger with Current Clamp Input

USB Temperature and Humidity Data Logger Instruction Manual

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

Millenium II +: general characteristics

DM650VI SENSOR/WALL MOUNTED VOLTAGE/mA DISPLAY

NHT-310. Broadband EM Field Meter: DC 40 GHz. HAVSCo LTD. Key Features:

BVR Series Battery Voltage Recorders

KS5 SYNCHRONIZATION METER

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

Operation Manual for Smart Logger II

Circuit Breaker Analyzer & Timer CAT66

Model R5005. Instruction Manual. True RMS Industrial Multimeter. reedinstruments. www. com

CORD-XL Dual-Channel Electronic Chart Recorder User s Manual

SCP for Plastics Processing

USB-500/600 Series Low-Cost Data Loggers and Accessories

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Kistler LabAmp. Electronics & Software. Charge Amplifier and Data Acquisition Unit for Dynamic Measurements. Type 5165A...

Circuit Breaker Analyzer & Timer CAT126

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

Circuit Breaker Analyzer & Timer CAT126

Precision Voltage Measurement. Instruments. Applications. Voltage Inputs. High-Stability, Low Drift Voltage References. Key Design Features

Data sheet CC 03, Commander Compact (603-1CC21)

EL-USB-ACT AC and DC Millivolt Data Logger with Current Clamp Input

P R O F E S S I O N A L T I M I N G. DOCKING GPS User Manual Version 01/2009

2 in 1 LAN Tester and Multimeter Model:

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

Stand-Alone, Low-Cost Data Loggers and Accessories. USB-500/600 Series Comparison Chart

mini CRD OMNIA _ MINI OMNIALOG READOUT UNITS AND DATALOGGERS

Circuit Breaker Analyzer & Timer CAT-P

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

testo 875 and testo 881 for professional building thermography

IP 20. Rated. with terminals

USER MANUAL MULTI COLOR TOUCH SCREEN PAPERLESS RECORDER TPLR-96 Series

Data sheet CPU 115 (115-6BL02)

Multi-Function Ground Resistance Tester Model 6471

IDS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

MULTICHANNEL DATA RECORDERS

CORI-GPS GPS CURRENT INTERRUPTER USER S MANUAL RCS PN MANUAL REV B

USER S MANUAL. Data Logger SOUND LEVEL METER.

Chart recorder. DS 400 mobile Affordable, mobile chart recorder. Flow Pressure / Vacuum Temperature Moisture / Dew point Optional third-party sensors

Specials. Fluke NEW. Multifunction Installation. Testers. Visual IR Thermometer Fluke VT04. Two Pole. Testers. Fluke 1650 series.

Products no longer available

HANDHELD CALIBRATOR-MULTIMETER OC502-t

is then retained absolutely without interruption.

Technical specification Marine Master Clock

Minilog RDL10. Technical Information. Measured value collector with 2 input channels for storing analog and digital values

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

ATS Automatic transfer switches Advanced version

BATTERY TESTING SYSTEM

HCS-5300MA/ 80 Digital Infrared Wireless Conference Main Unit

C100 Portable Multifunction

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter

PQA823 PQA824 Rel /09/12

SBS-S SERIES DC LOAD BANK USER MANUAL Rev

BSL Hardware Guide for MP35 and MP30-1 -

USB DIGITAL SOUND LEVEL DATA LOGGER USER S MANUAL DSM20

GEARMOTORS AF MOTORS FOR INVERTER C-1

Sefram SEFRAM DAS 20/DAS 40. Sefram

Electronic Loads. Installation & Operation Manual EL101/300 EL1000

C-322. Model. Instruction Manual. Datalogging Sound Level Meter. reedinstruments. www. com. Tripod sold separately (Model BS-6)

GL200A midi Logger. Wide Sample Interval Selections Sample intervals can be programmed to be one of sixteen values ranging from 100 ms to one hour.

Service Manual and Repair Guide

Really Performs! Here is a Hand-Held Data Logger that Royalton Rd. Cleveland, OH USA Tel: (440) Fax: (440)

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

TANDO 700. High-precision measuring and analysis system for dissipation/power factor and capacitance

UltraTEV Plus 2 Make Partial Discharge discovery simple.

Data sheet VIPA CPU 115DP (115-6BL22)

MMT330 Series Moisture and Temperature Transmitters for Oil

BACnet Controller for General-purpose Building Applications

CRIBS Installation and User Guide

Mag-01H. Fluxgate Declinometer/Inclinometer. Mag-01H D/I. World leaders in high precision magnetic field measurements

MARTINDALE INSTRUCTIONS MM35 DIGITAL MULTIMETER ELECTRIC. Trusted by professionals

Handheld hydraulic readouts & dataloggers

IR Wireless Interpretation System


DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

Handheld Gaussmeter Gaussmeter

Circuit Breaker Analyzer & Timer CAT126

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

OWNER S MANUAL 9908-TE. HIGH PRECISION AUTO-RANGING DC/True RMS AC BENCH-TOP DIGITAL MULTIMETER

DMT345 and DMT346 Dewpoint Transmitters

TM221M16R controller M IO relay

IDEAL INDUSTRIES INC. TECHNICAL MANUAL MODEL:

MODEL 9250 Preliminary data sheet

Temperature/Rh Data logger. Users Manual. USB Datalogger IP 65 Water Proof

Neon pr. ph/ ORP measurement. Applications. Description

AV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range

Transcription:

Sheet: 1 of 5 Datalogger and GPS Time Switch for CP 2-Channels (DC + AC = 4 values) Microvolt AC Filter max. 1,000 measurements / sec. 1,300,000 Values (4 MByte) GPS Time Switch 15 A relay Li-Ion battery for 1 month cont. switching DCVG + CIPS with GPS Waterproof IP68 General The new is a waterproofed universal measuring instrument with LCD and keyboard designed for CP measurement tasks. Used in data logger mode, the samples for both channels DC and AC simultaneously. In interrupter mode, the built-in relay swiches fully GPS synchronized for interrupting not only rectifiers, but coupons for IR-free potentials. Finally with survey mode, the is able to make DCVG and CIPS surveys while storing the GPS position for every measuring point taken. Datalogger with Microvolt Measurement Two channel sampling, each with DC and AC measurement, resulting in 4 values simultaneous measured per sample. Both DC channels got microvolt resolution and have active filters built-in to prevent low AC frequency interference. The is able to sample up to 1 300 000 values. This results in up to 20 min. sampling even when measuring in High-Speed mode (= 1,000 measurements / second). The built-in USB connector allows galvanically isolated data transfer via a USB. Miniaturised GPS Interrupter with Rechargeable Battery The has a mechanical 15A/60V relay built-in for switching of rectifiers, flanges and coupons. Optionally a version with built-in electronic relay 30A/60V is available. Via the keyboard and the LCD a switching cycle resolution of 0.1s is configurable by the user. In addition, night and weekend savings are selectable. The rechargeable Li-Ion battery allows GPS synchronised switching for 30 days without recharging. For fixed installations in rectifier housings an USB mains supply and fix mount can be used. To increase the switching power even more, miniaturised external slave relays for are available with 50 A and 100 A. Coupon Measurement with MiniCoup For measuring IR-free potentials on a coupon, can sample and interrupt simultaneously. For accurate sampling of the complete off depolarisation curve, is able to measure 1000 samples/s for one channel for up to 20 min. time. Optionally with the MiniCoup adapter and its built-in 10 Ohm shunt, the samples every second for up to 24h. By just connecting pipe, electrode and coupon with the adapter sockets, On and Off potential and DC and AC current are collected simultaneously. GPS Synchronisation and GPS Position The optional Garmin GPS receiver allows synchronisation of the time and date. Using the as data logger in DCVG survey mode, the GPS positions are automatically stored beside each value. DCVG and CIPS survey with Google Maps presentation Like with an analogue multimeter, shows the DCVG voltage difference in a bar graph for quick recognition. With a simple press of the OK -button mounted on the electrode, the DCVG value and the related GPS position are stored and the survey continues. In the same way potential (CIPS) and/ or voltage gradient measurements can be done. The survey path and the defects can be directly presented with Google Maps and the WinLog 2.0 software.

Sheet: 2 of 5 Technical data Measuring channels: 2 (DC+AC parallel = 4 values) Measuring range and resolution: ± 100 mv / 1 µv (only DC) ± 10 V / 0.1 mv (DC+AC) ± 100 V / 1 mv (DC+AC) Input impedance: 10 MΩ (for microvolt 250 KΩ) Maximum sampling rate: 1,000 samples / second 10 samples / second (with filter) Lowpass filters: 16.6 Hz > 60 db (factor 1,000) 50.0 Hz > 100 db (factor 10,000) Recording capacity: 1,300,000 sampling values and 10,000 DCVG/CIPS measurements Switching cycle: In 0.1s steps, user configurable Synchronization: GPS and manual or external (Master / Sleeve) Switching power: Mechanic relay 60 V / 15 A Electronic relay 60 V / 30 A Power supply: Lithium-ion battery 3.6 V / 1,900 mah charged with USB power supply Time accuracy: < 10 ms / 24h with GPS synchronisation Battery time: Dimension: Weight: Datalogger mode: 10 days with 0.5s sampling rate 20 weeks with 60s sampling rate Interrupter mode: 30 days with 4/2 and GPS DCVG / CIPS: 20 hours with GPS position 148 x 68 x 42 mm 350 g LS100 - Electronic Powerswitch 100 Ampere Powerswitch with electronic relay. Build for usage in combination with a switcher. (For example with ) The LS100 is intended for switching of CP rectifiers, flanges, soutirages and drainages. Easy to install with no need for checking the switching polarity, as the LS100 switches polarity independent. Technical data LS100 Housing: Metal with built-in heat distribution plates Switching Power: 100 A (100 V DC / 70 V AC) Operating Temperature: -20 C up to 60 C Dimensions: W 125 x H 75 x D 160 mm (incl. 30 mm pole clamps) Weight: 1.25 kg Item No.: 140211

Sheet: 3 of 5 WinLog 2.0 Data Logger Software The software WinLog 2.0 for the evaluation of data loggings is especially designed for the new. Beside the easy transfer of the samplings via USB to the PC, the WinLog 2.0 software supports 4 channel data evaluation with statistic (max, min and median building) and comprehensive printing features. For the DCVG and CIPS evaluation WinLog 2.0 with an internet connection allows the instant presentation of the survey path together with the location of the defects.. WinLog 2.0 works with Windows XP, Vista and Windows 7 (32/64 Bit) Stray current sampling during 24 hours Median values of the Off-Potential with a screen mouse zoom

Sheet: 4 of 5 Print: Coupon switching with 1 ms sampling rate Print: 24 hours coupon measurement with P ON + P OFF + I DC + I AC

Sheet: 5 of 5 Built-in export feature for Microsoft Excel DCVG measurement export to Google Maps for defect localization