PM2.5 and PM10 Monitors , & Instruction Manual

Similar documents
Dissolved Oxygen Meter Kit DOK. Instruction Manual

Thermal Imaging Camera 220 x Instruction Manual

Water Quality Meter. Water Quality Meter Kit. Instruction Manual

Sound Level Pen Instruction Manual

Light Meter (Foot Candles)

Visible Light SD Card Datalogger

Datalogging Conductivity/ TDS Meter. Instruction Manual

Torque Meter. Instruction Manual

SOUND LEVEL PEN INSTRUCTION MANUAL SPER SCIENTIFIC

Mini Environmental Quality Meter

Datalogging IAQ Meter Instruction Manual

Mini Environmental Quality Meter

AquaShock ph Meter K

Mini Environmental Quality Meter

DIGITAL SOUND LEVEL METER. Instruction Manual

Anemometer/Thermometer

I/R Thermometer Gun 8:1

Psychrometer/Anemometer. Instruction Manual

Light Meter with Bar Graph

4-Channel Thermometer

Datalogging RH / Temperature Pen Instruction Manual

Vacuum Meter Instruction Manual

Bluetooth IR Pen. Instruction Manual

Oxygen Pen Copyright 2015 by Sper Scientific ALL RIGHTS RESERVED. Printed in the USA

Manometers 2PSI, 5PSI, 15PSI, 30PSI, 100PSI , , ,

Wide Range Pressure Meter Instruction Manual

Torque Meter. Instruction Manual

PROGRAMMABLE DIGITAL REFRACTOMETER INSTRUCTION MANUAL

DO Meter Kit. Instruction Manual

Mini Environmental Quality Meter

4 Channel Datalogging Thermometer. Instruction Manual

RH/Temperature SD Card Datalogger. Instruction Manual

POCKET DIGITAL REFRACTOMETERS ~

Mini Sound Meter. Instruction Manual SPER SCIENTIFIC

Type K/J Thermometers

Anemometer SD Card Datalogger. Instruction Manual

Large Display Salinity & Conductivity Pens &

User Guide. Moisture Meter. Model MO250

4-Channel Datalogging Thermometer

Temperature Datalogger

DATALOGGER With DATA LAB GRAPHICAL SOFTWARE INSTRUCTION MANUAL SPER SCIENTIFIC

Datalogging Manometers 2PSI, 5PSI, 15PSI , ,

DIGITAL REFRACTOMETERS , , , INSTRUCTION MANUAL SPER SCIENTIFIC LTD.

Datalogging Manometer

Datalogging ph Meter

WBGT SD Card Datalogger. Instruction Manual

Video Borescope Inspection Camera

WBGT SD Card Datalogger. Instruction Manual

Datalogging Hot Wire CFM Anemometer

Advanced Datalogging Thermometer. Instruction Manual

Instruction Manual HI 9033 HI Waterproof Multi-Range EC and TDS Meters for Field Applications.

CO2 Controller Operating Instructions Models: RAD-0501, RAD-0501A, RAD-0501E 1. Product Description

TestLink Software for Software Instruction Manual

CO2 1% or 30%, Temperature & %RH, Diffusion Data Loggers

User Manual. Please read the Important Instructions for Use overleaf.

Dissolved Oxygen Meter

CA846 THERMO-HYGROMETER ENGLISH. User Manual. 99 Washington Street Melrose, MA Phone Toll Free

Digital Timer Outlet Model No.: EDT-1USA. Questions or Concerns? (855)

1-36V, 0-3A DC Power Supply

The Portable Air Pollution Monitor

User s Manual. Digital Baby Scales. Hopkins Featherweight Baby Scale # Hopkins Featherweight XL Baby Scale # # #688340

IAQ-CALC INDOOR AIR QUALITY METER MODEL 7525

PH SD Card Datalogger. Instruction Manual

SLA Battery Capacity Analyzer

Heavy Duty Datalogging Light Meter

QUICKLOOK. User Manual. Please read the Important Instructions for Use overleaf

SoniChek MC. 99 Washington Street Melrose, MA Phone Toll Free TRIPLETT. Mini Sound Level Meter C Weighted

Owner's Manual. For latest instructions please go to

USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USE.

Model Instruction Manual. Digital Pocket Psychrometer. reedinstruments. www. com

QUICKLOOK. User Manual. Please read the Important Instructions for Use overleaf

User s Guide HHPT-51. Particle Counter. Shop online at omega.com. For latest product manuals:

USB DIGITAL SOUND LEVEL DATA LOGGER USER S MANUAL DSM20

Advanced Datalogging Sound Meter Instruction Manual

IAQ-CALC TM Indoor Air Quality Meter

PILLBOX TIMER WITH PULSEMETER

User's Guide. Cup Thermo-Anemometer. Model AN400

3.5 TFT LCD CCTV Service Viewer with Wristband LCD35SV

INSTALLATION AND USER GUIDE 2800LBY SINGLE LINE HOTEL LOBBY TELEPHONE

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements

ARA FTS Flow Calibrator. Operation Manual August 1, 2016

IAQ-CALC TM Indoor Air Quality Meter

Raphael Monitoring Kit. Instruction Manual

Mini Photo Tachometer Model Mini Contact Tachometer Model

True RMS AC Voltage/Current Datalogger

4-20mA Display. Installation and Operation Manual. Rev 4/3/2019 Part #

Introduction. Package Contents. System Requirements

USER MANUAL. Hygro-Thermometer. Model RHT510. Additional User Manual Translations available at

USER MANUAL. Light Meter. Model LT510. Additional User Manual Translations available at

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

USERS GUIDE MCX-STH. 3G SDI to HDMI Converter. Manual Number:

Carbon Dioxide Monitor Instruction Manual

Owner's Manual. True RMS Multimeter. Model No Safety Operation Maintenance Español

INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE

Instruction Manual RS-1660

Model P4470 Save A Watt Operation Manual

LED-200P. Mobile LED Light Set. User Manual

SuperHeat Psychrometer Models RH350 and RH355 (kit)

AEROTRAK HANDHELD AIRBORNE PARTICLE COUNTER MODEL 9306 QUICK START GUIDE

PM-204A/B. Power Meter. Operation Guide

Transcription:

1 PM2.5 and PM10 Monitors 900014, 900015 & 900016 Instruction Manual Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117 Fax: 0-3844-6200 Email: info@ete.co.th www.ete.co.th

TABLE OF CONTENTS INTRODUCTION...3 BUTTON DESCRIPTION...4 SET UP & USE...5 CARE AND MAINTENANCE...6 SPECIFICATIONS...7 WARRANTY...8 2

INTRODUCTION 900014: PM2.5, PM10, Relative Humidity, and Temperature in C 900015: PM2.5, PM10, Relative Humidity, and Temperature in F 900016: PM2.5, CO 2, Relative Humidity, and Temperature in F Accurately measures particulate matter in the air <2.5 microns (PM 2.5), and <10 microns (PM10). These tiny air pollution particles travel into the respiratory system reaching the lungs and may cause respiratory and other health problems. All parameters are simultaneously displayed on a large backlit color TFT display along with a graph of historic data. The meter s simple two-button operation is quick and easy. For a complete analysis of indoor air quality, the 900016 meter displays both PM2.5 and CO 2. The unit can be used as a benchtop monitor using the fold-out stand or as a portable meter. It comes complete with a rechargeable Lithium ion Battery and micro USB power cord. www.eastern-energy.com 3

BUTTON DESCRIPTION All models have two buttons and a power port as shown below. POWER & SCROLL BUTTON SLIDE SWITCH FOR PORTRAIT OR LANDSCAPE ORIENTATION MICRO USB POWER PORT www.eastern-energy.com 4

SET UP AND USE First-time Set-up All models self-calibrate. However, there are steps that must be taken the first time the meter is turned on. 1. Find a time period in which no humans will be present in a well-ventilated room overnight (7-8 hours). 2. Remove the plastic face shield and protective plastic bag from the meter. This step is important because the shield blocks the internal sensors. 3. Plug the power cord into the micro USB port and turn the meter on. The meter can be powered by a computer s USB port or any cell phone power block during first-time set-up. 4. The screen displays Loading and a status bar will briefly display on the main screen. 5. When the meter powers on, both the humidity and the CO 2 (model 900016) readings will be inaccurate. This is normal due to the air trapped in the housing during storage. 6. Leave the meter in a well-ventilated room overnight to allow the humidity and CO 2 readings to stabilize overnight. www.eastern-energy.com 7. The meter is now ready for use and can be operated with or without the power cord. 5

General Use 1. For all models, the key readings will display on the main screen. The main screen is underway when the multicolored bar graph is seen in the upper right corner. 2. To scroll between individual screens, press the button in the center of the meter. 3. The final screen displays two QR barcodes. This screen is for manufacturing purposes and is not necessary for the operation of the 900014, 900015, and 900016 meters. CARE AND MAINTENANCE Do not drop the meter as it may damage the internal sensors or crack the TFT display. Occasionally, you will have to recalibrate the meter if readings become erratic or unexpected. Do this by following the steps for first-time setup. If the meter is repeatedly exposed to dirt, dust, or corrugate wipe both the meter and the surface with a damp cloth periodically. Do not use abrasives or solvents containing carbon to clean the meter. www.eastern-energy.com 6

SPECIFICATIONS Range Resolution Accuracy PM 2.5: 0 to 500 µg/m 3 1 µg/m 3 ±10% PM 10: (Models 900014/15) 0 to 500 µg/m 3 1 µg/m 3 ±10% Temperature C: (Model 900014) Temperature F: (Models 900015/16) -20 to 40 C 1 C ±2 C -4 to 105 F 1 F ±4 F RH: 0 to 95% 1 % ±8% CO2: (Model 900016) 0 to 5000 1 ppm ±(50 ppm + 5% rdg) 7

WARRANTY Sper Scientific warrants this product against defects in materials and workmanship for a period of one (1) years from the date of purchase, and agrees to repair or replace any defective unit without charge. If your model has since been discontinued, an equivalent Sper Scientific product will be substituted if available. This warranty does not cover batteries, battery leakage, or damage resulting from accident, tampering, misuse, or abuse of the product. Opening the meter to expose its electronics will void the warranty. To obtain warranty service, ship the unit postage prepaid to: Contact : EASTERN ENERGY CO.,LTD. (HEAD OFFICE) 40/4 Vitoondumri Rd., Banbueng, Banbueng, Chonburi 20170 Tel: 0-3844-6117 Fax: 0-3844-6200 Email: info@ete.co.th www.ete.co.th 8 5/10/2018