LogicMachine5 Reactor GSM

Similar documents
LogicMachine5 Reactor IO V2

LogicMachine5 Power (LM5p-DW1)

LogicMachine5. LogicMachine (LM) is your easiest way to program complex logic in KNX/EIB, Modbus, BACnet, DALI, 1-wire LM will enable you to

CANx / LoRa 433 MHz 8 x Analog inputs / Digital ouputs

Amati.linea Streaming Player light

DALI RS485 gateway. ENG - Data sheet Issue date Application

DALI RS485 gateway. ENG - Data sheet Issue date Application

DALI RS485 gateway. ENG - Data sheet Issue date Application. Types of product. Standards and norms compliance.

DKG-210 UNIVERSAL INTERNET GATEWAY UNIT

Hardware manual. 1. Overview 2. Technical characteristics 3. Connections. ( Portal (../portal/portal.html)

See instructions to download and install the latest version of LinkBoxLON and the user's manual at

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

UR51 Industrial Cellular Router

EZmoto V4.1 Product description Rev. 2 30/07/2015

6 Port Unmanaged Industrial Gigabit Ethernet Switch w/ 4 PoE+ Ports and Voltage Regulation - DIN Rail / Wall-Mountable

3G/4G LTE Cellular to Ethernet and Serial Secure Modbus Gateway/Router. MB5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

INTRODUCTION - DISPLAYS, DATA LOGGERS AND SOFTWARE

mark150s mark150/485s DDC controllers Summary

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

Hardened Web-Smart PoE & High Power PoE Ethernet Switch

MODEL CIO-EN MODBUS/TCP, MODBUS/RTU I/O MODULE

Manual and application description 4 channel 0-10V dimmer V2.0

Quick Start Guide. Industrial Managed Gigabit Ethernet PoE+ Switch LPH2008A-4GSFP

UCM 94/1 3G/GPRS Modem for RTU32 Series

UR72 & UR75 Industrial Cellular Router

User Manual. cmt-svr Startup Guide

Setting Up Your Cisco Unified Videoconferencing 3515 MCU

QUICK-START EMU M-BUS CENTER ENGLISH

F Series Indoor Fixed IP Camera. Quick Start Guide

Environmental Conditions

MX-1 GSM/GPRS M-BUS DATA LOGGER USER MANUAL

Overview of the Cisco Wireless Gateway for LoRaWAN

Cradlepoint ARC CBA850 Specifications

USER MANUAL FOR GS100/GS1003G

Communication Interface

INSTALLATION MANUAL Z-UMTS

Quick Start Guide REX 100 3G LTE. Version. 2 en. as of FW

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

ROCKETLINX ES8508 ES8508 ES8508F ES8508-XT ES8508F-XT QUICK INSTALLATION GUIDE

USER MANUAL COMBOX.M - Modular energy management data concentrator

TECHNICAL SPECIFICATIONS EN

DIRIS Digiware D and C Communication and control power interfaces

Submittal Data Sheet WAGO Node for itm

IMIO100 IMIO105. DDC controllers. Summary

Quick Installation Guide

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Manual and application description KNX/EIB LED driver V2.0

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

with Backlight Graphic LCD Screen

CMi- box. M-Bus Metering Gateway for Mobile Network GSM/GPRS TCP/IP. CMi-Box

Connections, displays and operating elements C D

LogicMachine5 Reactor GSM (LM5p-GSMC, LM5p- GSM)

KAUGJUHTIMISSÜSTEEMID TELECONTROL SYSTEMS MODEM TELEM-GSM/GPRS 3G. User manual

LAUREL. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations ELECTRONICS, INC.

Reliable and Remote-Manageable for Large Scale M2M Deployment

BACnet/IP Web Interface

EZ864 UMTS Terminal Telit Cellular GSM Engine

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

LightRules Network Infrastructure

GSM-PRO2: the perfect communicator GSM-PRO2-GPS. Input and output. Expansion modules

Installing the Cisco Unified Videoconferencing 3545 MCU

Universal application platform for telecom operators. by Embedded Systems

SXPi Linux box version 1.0

TC Type Range Conformity Error. J -210 C to +760 C (-347 F to F) ±0.09 C (±0.16 F) K -244 C to C (-408 F to F) ±0.1 C (±0.

connecdim Gateway G1 Ethernet TCP/IP to DALI

Omega 4K/UHD Scaler for HDBaseT and HDMI with USB

Output Signal. Temperature 22DTH-56M BACnet DC V, DC V. Electrical Data Power Supply DC V, ±10%, 0.7 W

IG601 Intelligent Gateway Quick Guide

Multi-Point Gas Detection and Control System

Xcom-GSM / Xcom-LAN Remote communication sets for Xtender and VarioTrack systems

8~14-Port Managed Ethernet Switch

PACSystems* RSTi-EP EPSCPE100 Enhanced performance standalone controller for RSTi-EP Platform CPU Quick Start Guide

ELECTRONIC CONTROLS & SENSORS. AK-SC255 Fact Sheet Version R Software Software version 02_085

Technical Manual Nova: Cabinet Security Management System (CSMS)

User manual Compact Web PLC WP240 series IEC-line. update:

wienet VPN industrial router Telecontrol, remote maintenance and alarm - simply and safely Managing from a distance.

MODEL 9250 Preliminary data sheet

LAUREL. Laureate RTD Temperature Panel Meter / Controller ELECTRONICS, INC. Features. Description. Specifications

GenIP : Intelligent gateway dedicated to most critical industrial applications

See instructions to download and install the latest version of LinkBoxEIB and the user's manual at

584 5WG AB_1 DELTA

Lantech. IPES /100TX with 4 PoE Injectors 24~48VDC Industrial Switch. User Manual

550VA Audio/Video Backup Power Block - Exclusive UPS Protection for Structured Wiring Enclosure


Industrial Remote Access Solution

Technical Data. MDH800 - MDH859 (from HW 02) - V DE

LTE configuration tips and tricks

Aarlogic TER-GX910. Product description. Rev.9 17/03/2013

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

icex-cmtm General specs and Installation guide

INSTALLATION GUIDE. InBio Pro Series Access Control Panels. Date: June, 2016 Version: 1.3

LAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description

User Manual Entry Line Industrial Gigabit Ethernet High Power 60/95 W PoE Injector

8 10/100/1000T Industrial Switch. User Manual MS655208(X)

Communication over Modbus protocol Connection with multiple controllers Application upgrade by using an SD 1) card or a USB stick

Panoramic Power Installation and configuration guide

Industrial Slim Type Fast Ethernet Rail Switch

-SMS Alert Gateway. EzSMS-Lite USER S MANUAL

See instructions to download and install the latest version of LinkBoxMB and the user's manual at

Transcription:

Embedded Systems SIA, VAT No LV40003411103 47. Katolu str., Riga, LV 1003, LATVIA Phone: +371 67648888, fax: +371 67205036, e-mail: sales@openrb.com LogicMachine5 Reactor GSM LogicMachine (LM) is your easiest way to program complex logic in KNX/EIB, Modbus, BACnet, EnOcean and other networks. LM will enable you to efficiently customize building automation processes, easily delivering unlimited flexibility benefit to end users in a cost-effective way. LM5p-GSM is an embedded platform with integrated Ethernet, USB, GSM, Serial interfaces and I/O ports, CAN FT. LM allows using it as cross-standard gateway, logic engine, visualization platform, IP Router. Scripting templates provides user-friendly, flexible configuration interface and integration with cloud/web services, 3 rd party devices. Via applying custom scripts LM can simultaneously act as thermostat, security panel, lighting controller, etc. LogicMachine application store and external app development possibility allows to extend device functionality and adjust to a specific market segment. ENG - Data sheet Issue date 6.02.2018 1

Application 3G gateway for Internet access Logical functions WEB SCADA visualization for PC and touch-devices cross-standard gateway integration with third party devices over USB, RS485 serial port, Ethernet AV, IR, HVAC Data logger with trends Presence monitoring Lighting regulation Universal controller (lighting, shutter etc.) Health/activity monitoring Internet-of-Things Cloud server/client Energy metering 2

Types of product LogicMachine5 Reactor GSM Power CANx LogicMachine5 Reactor GSM Power KNX LM5p-GMSC LM5p-GMS Standards and norms compliance EMC: PCT EN61000-6-1 EN61000-6-3 Certificate Technical data: Power supply: 2 x 24V DC on terminal connectors (1 for LM powering, 1 for external relay powering) or 24V DC Passive Power-over-Ethernet Power consummation: 1.3W Interface: GSM modem GSM module with Antenna 1 Push-push micro-sim connector 1 10BaseT/100BaseTX 1 RS-485 1 RS-485/RS-232 1 (switchable in software full-duplex=rs232, half-duplex=rs485) USB2.0 1 Analog input/digital output 16 Analog input 0-10V 1 Analog inputs for current Measurement clamps 3 (sensor specification) 1-Wire 1 CAN FT 1 (protocol features) GSM module type Quectel UG95 Frequencies 900/2100MHz @UMTS 900/1800MHz @GSM Worldwide UMTS/HSPA and GSM/GPRS/EDGE coverage Maximum data rate 7.2Mbps downlink 5.76Mbps uplink 3

Connections: CAN bus: Bus Connection Terminal 0.8mm2 Power supply: Screw, 5 mm2 Serial: Screw, 3.5 mm2 I/O: Screw, 3.5 mm2 1-wire Screw, 3.5 mm2 Operating elements LED 1 CPU load 1 - Activity Enclosure: Material: Polyamide Color: Gray Dimensions: 61(W)x90(H)x108(L) mm Usage temperature: 0C... +45C Storage temperature: -15C... +55C Weight: 150g Warranty: 2 years Relative Humidity: 10...95 % without condensation Caution Security advice The installation and assembly of electrical equipment may only be performed by skilled electrician. The devices must not be used in any relation with equipment that supports, directly or indirectly, human health or life or with application that can result danger of people, animals or real value Electrical connection The devices are constructed for the operation of protective low voltage (SELV). Grounding of device is not needed. When switching the power supply on or off, power surges must be avoided. 4

Insert SIM card 1) Open front cover of the enclosure with help of screwdriver (by pushing to yourself the side edge of base cover) 2) Open MicroSIM holder by moving down the top part and lifting up 5

3) Insert SIM card and close the holder. Close the front cover 6

4) Connect 3G antenna Quick startup guide 1) Mounting the device on DIN rail 2) Connect 24V power supply to the device (either through separate 24V crew terminals or through Passive 24V DC Power-Over-Ethernet) 3) Connect Ethernet/LAN cable coming from the PC/switch 7

Setting up 3G modem In System configuration go to Network 3G/PPP connection. Fill required fields depending on your 3G operator settings, apply settings. Default IP configuration of the LM5 Login name admin Password admin IP address 192.168.0.10 Network mask 255.255.255.0 Reset device You can either reboot the device by pressing RESET button or reset the configuration to factory defaults: Press and hold for <10 sec reboot the device Press and hold for >10 sec reset networking with IP to factory default Press and hold for >10 sec and again press and hold for >10 sec full reset of configuration to factory defaults 8

Terminal connection schemes Model 9

Powering over Ethernet LM5 supports two powering modes: - regular powering over screw terminals (Jumpers up or down) - passive PoE powering over 24V DC (Jumpers down) Please note that there are two PoE types of PoE switches/adapters passive and active (802.3af). In passive mode 4 Ethernet cable wires are used for data and 4 are used for power. In active PoE mode data and power goes together. Passive PoE switch Passive PoE adapters 10

canx connection / Powering over 24V terminals 11

RS-485 connection There can be used max two RS-485 on LM5 Lite. First one is definitive, second one is software switchable either it works as RS-485 or as RS-232 : - If it is set up as full-duplex it will operate as RS-232 and respective TX/RX/GND screw terminals should be used - If it is set up as half-duplex (*) it will operate as RS-485 and respective A/B/GND screw terminals should be used *RS-485 is chosen in this case, RS-232 is not activated 12

RS-485/RS-232 connection If second serial port is set as full-duplex in LogicMachine configuration, it will operate as RS-232 and respective TX/RX/GND screw terminals should be used. *RS-232 is chosen in this case, RS-485 is not activated 13

Digital output (e.g. relay/contactor) 14

Digital or Analog input (e.g. pushbutton or 0-5V current measurement sensor) 15

Digital input (e.g. pushbutton) 16

1-wire connection 17