Grounding Monitoring Device Series 8485

Similar documents
Grounding Monitoring Device Series 8485

Ground Monitoring Device Series 8485

Grounding Systems / Ground Monitoring Device Series 8146/5075 and 8125/5071

Terminal Boxes Series 8118

Linear Luminaire with LED Series EXLUX 6002/1 Version IIB+H2

Linear Luminaire with LED Series 6012/5

Load Disconnect Switches and Motor Switches

Emergency Luminaire for Fluorescent Lamps Series EXLUX 6009

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Linear Luminaire with LED Series 6412/5

Tubular Light Fitting with LED Series 6036

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Position Switches Series 8070

Micro Limit Switch Series 8064

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Control Buttons / Switches for Panel Mounting Series 8003

Control Switches for Panel Mounting Series 8003

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Ethernet CPU Module & Power Module for Zone 1 / Div. 1 Series 9441/12 and 9444/12

Cable End Boxes Series 8146

Miniature Circuit-Breaker IEC Series 8562

5 Fieldbus Technology

Operating and monitoring systems Thin Client SERIES 500 Device platform EAGLE PM ET-556-TX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM ET-436-TX

Operating and monitoring systems Panel PC SERIES 400 Device platform EAGLE PM MT-436-TX

Reed sensor For bypass level indicators Model BLR

Threaded resistance thermometer Miniature design Model TR10-D

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

CPU module for zone 2 Series 9442/35

Resistance thermometer With spring-loaded tip Model TR55

GRP Flameproof Visual Signal Xenon or Steady LED

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE PM MT-336-FX

Operating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern

SolConeX Wall-Mounted Socket, 16 A

Engineering Guideline. pac-carriers Type for Honeywell system Experion Series C I/O

MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Threaded thermocouple Miniature design Model TC10-D

PI-EX-ME-2NAM/COC-24VDC

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

Gas-actuated thermometer Stainless steel version Model 73

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

ATX MRE Series 16 and 32 Amp Multiple Socket Outlets Stationary and Portable. Increased Safety

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

PI-EX-ME-2NAM/COC-120VAC

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS ET-306-FX

Operating and monitoring systems Operator Interface SERIES 300 Device platform EAGLE OS MT-316-TX

2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)

Technical Data. General specifications. Rated operating distance s n 3 mm

Technical Information Promonitor NRF560

Product Details. Contents. Features and Mounting Options for SUNNY STRING-MONITOR SSM24-11

Overfill Prevention Controller EUS-2

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-438-2FX

PHOENIX CONTACT - 12/2007

Loads and Motor Switchgears

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Safety instructions Overvoltage protection B81-35

Cradle relay AC. Electrical data Operating data (coil circuit) U N. Explosion protection Marking ATEX. II 2G Ex db e IIC Gb I M2 Ex db e I Mb I N

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK ET-498-2TX

Bayonet resistance thermometer Model TR53

SolConeX extra-low voltage flange socket

2.2. Ex-Linear LED light fittings. ellk/m 92 LED 400/800 / ellk/m 92 LED 400/800 V-CG-S / NE / NIB-HT / NIB-CSA (Zone 1, 2, 21, 22)

Technical Datasheet. Connectors, Plugs & Sockets. Table of Contents. Selection Guide 2. 16A Range (ELCX ) 3. 32A Range (ELCX

Dräger Polytron 8200 Stationary gas detector (CatEx)

Conveyor Belt Alignment Switches from IDEM

PC100 - Concept. Advantages in comparison

Series 3730 Type Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner

Minimum cross sectional area of Conductor mm²

Supplementary Components WirelessHART products

Junction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety

Capacitance level switches LS 210 LS 220

Operating and monitoring systems Panel PC SERIES 400 Device platform SHARK MT-438-1TX

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

Sales: Malux Finland Oy, P.O.Box 69, FI Porvoo, Phone , Fax ,

XLF. Ex d. - Zones 1, 2, 21, 22 - Obstruction warnings - Stroboscopic lights - Single or double fixtures - Low wind resistance

Inductive sensor with analog output BI15-M30-LI-EXI

KINAX WT720 absolute, programmable angular postion transmitter

EX-PROOF THERMAL ANALOGUE CAMERAS IN COMPACT DESIGN EC-840S-TIC-19A - Series

Junction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety

Resistance thermometer For additional thermowell Model TR10-B

Ex emergency pull-wire switches Ex ZS 71

Safety instructions. IECEx TUN Ex ia IIC T6 Gb

Level sensor with reed measuring chain Model FLR, for the process industry

INTRINSICALLY SAFE Ex ia PSU TYPE AC36W

EX-PROOF HD CAMERA IN A COMPACT DESIGN EC-910-AFZ-Full HD IP 10 x Zoom

Digital Explosion-proof Intercom Stations DX/DXE 0x5 Series

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline

Control Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety

21023, 21025, 2/2 Direct solenoid actuated poppet valves

Level limit switch Series RF 3000 Selection list. Overview 2

Level measurement. Applications. Special features. Description

Isolating repeater IRU 420

Standard enclosure for Remote I/O Series 8150

SMARTLINE RM76 Supplementary instructions

Cable Glands. Description Introduction to Cable Glands 399. EEXe Series EEXe Series. A2F, E1FX/E2FX, E1FW/E2FW and T3 Series

RT2Y Compact temperature switch intrinsic safety

Metal Position Switch

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Transcription:

www.stahl.de > Controlled electrostatic grounding of road tankers and rail cars during loading > Continuous monitoring of correct grounding > The object recognition prevents potential operator errors (with road tankers) > Water jet protected aluminium enclosure IP65 > Two potential-free change-over contacts per channel for signalling > Insulated point of suspension for clamps > Ambient temperature - 55... + 60 C 17198E00 The ground monitoring device ensures the electrostatic grounding of road tankers and rail cars while loading flammable liquids and powder. The device provides a conductive connection to the ground and monitors in parallel the quality of the electrostatic grounding. This guarantees that the electrostatic charge remains at a safe level and that no explosion hazard is generated by uncontrolled energy discharge. The following recommendation requires grounding during loading and recommends interrupting loading in case of incorrect grounding: > CLC/TR 60079-32-1 Electrostatic hazards - guideline > TRBS 727 rules for avoiding ignition hazards as a result of electrostatic charges ATEX / IECEx Zone 0 1 2 20 21 22 Ex i interface x x x x For use in x x x x WebCode 8485A Grounding Systems and s /1

Selection Table Version Description Order number Weight Monitored electrostatic grounding of tank containers and rail cars during loading Ambient temperature: - 55... + 60 C kg 8485/111-42 12.100 Single-channel grounding system 12635E00 Monitored electrostatic grounding of tank containers and rail cars during loading Ambient temperature: - 55... + 60 C 8485/112-42 13.100 Dual-channel grounding system 12633E00 10 m ÖLFLEX with cable gland *) Clamp is made of stainless steel Ambient temperature: -40... +60 C 240197 2.900 Clamp with cable 17200E00 10 m SIHF-J with cable gland *); Clamp is made of stainless steel; Ambient temperature: - 55... + 60 C 238969 2.900 Clamp with cable 17130E00 10 m ÖLFLEX with cable gland *); Clamp is made of stainless steel; Ambient temperature : - 30... + 60 C 238970 4.000 17199E00 Clamp with spiral cable Grounding clamp 17132E00 Robust ergonomic grounding clamp, stainless steel, and fast-action plug. Ambient temperature : - 40... + 60 C Automatic winder with 9 m of oil and petrol resistant cable with robust ergonomic grounding clamp of stainless steel, and fast-action plug, Plastic enclosure 238971 2.000 247660 7.300 17637E00 Grounding clamp with automatic cable winder Automatic winder with 20 m of oil and petrol resistant cable with robust ergonomic grounding clamp of stainless steel, and fast-action plug, Aluminium enclosure, protected cable duct with stopper 247671 14.500 17636E00 Grounding clamp with automatic cable winder /2 Grounding Systems and s

Selection Table Version Description Order number Weight Robust ergonomic grounding clamp with 150 mm of cable and fast-action plug kg 247675 0.600 Grounding clamp 17638E00 Configuration set consisting of infrared adapter with USB port and CD-ROM with configuration software 202511 0.500 Configuration set 12643E00 *) Special cable length possible on request (max. 20 m). Price and date of delivery differ from the standard. Explosion Protection Global (IECEx) Gas and dust IECEx FTZU 15.0031X Ex d ib [ib] IIB T4 Gb Ex ib [ib] tb IIIC T130 C Db Europe (ATEX) Gas and dust FTZÚ 09 ATEX 0059X E II 2 G Ex d ib [ib] IIB T4 Gb E II 2 D Ex ib [ib] tb IIIC T130 C Db Certifications and certificates Certificates IECEx, ATEX, Kazakhstan (TR), Russia (TR), Belarus (TR) Further parameters Installation in Zones 1, 2, 21, 22 Safety data For signalling contact Max. connectable voltage 50 V DC U i Max. permissible current I i 200 ma Electrical data Power supply Nominal voltage Nominal current Frequency range Power consumption Output Signalling contact Minimum load Maximum load DC Maximum load AC Operating mode selection per channel Nominal voltage range AC: Nominal voltage range DC: 50 ma 47... 63 Hz 10 VA 20... 230 V 20... 300 V Ex i or Ex e - two potential-free change-over contacts per channel 10 V DC / 100 ma 230 V DC / 0.25 A 40 V DC / 3 A 230 V AC / 3 A Road tanker and rail car recognition by means of DIP switch Selection via DIP switch Grounding Systems and s /3

LED indication road tankers Operating principle: LED indication Grounding condition with road tanker Clamp is not connected, grounding equipment not in use Reaction of the grounding monitoring device Grounding incorrect Red indicating lamp ON Green indicating lamp OFF Contacts OPEN 10736E00 Clamp is directly grounded, e.g. via the loading platform Grounding incorrect Red indicating lamp ON Green indicating lamp OFF Contacts OPEN 10737E00 Clamps connected to tank vehicle. Grounding ok Red indicating lamp OFF Green indicating lamp ON Contacts CLOSED 10738E00 Clamps connected to tank vehicle. Tank vehicle is grounded subsequently (e.g. via the loading arm). Grounding ok Red indicating lamp OFF Green indicating lamp ON Contacts CLOSED 10739E00 Mechanical data Enclosure version Flameproof enclosure (Ex d) Degree of protection IP65 Material Enclosure Aluminium Grounding clamp Stainless steel Ambient conditions Ambient temperature -55... +60 C Storage temperature -55... +60 C Mounting / Installation Cable glands Cable diameter range 6 12 mm Connection Maximum diameter, single-wire - rigid 2.5 mm 2 - flexible 2.5 mm 2 - flexible, cable end sleeves with plastic cover 1.5 mm 2 - flexible, cable end sleeves without plastic cover 2.5 mm 2 /4 Grounding Systems and s

Version Clamp with cable (art. no. 240197) Clamp with spiral cable (art. no. 238970) Mechanical data Material Clamp with SIHF-J cable (art. no. 238969) Grounding clamp Stainless steel Stainless steel Stainless steel Cable type 10 m ÖLFLEX 540 P 3 GX 2,5 blue with cable gland 10 m ÖLFLEX 540 P 3 GX 2,5 blue with cable gland 10 m self-extinguishing and flame retardant SIHF-J 3 GX 2,5 red-brown with cable gland Ambient conditions Ambient temperature -40... +60 C -30... +60 C -55... +60 C Mounting / Installation Cable entries Clamping range 6... 12 mm 6... 12 mm 6... 12 mm Design Automatic cable winder with 20 m of cable (art. no. 247671) Automatic cable winder with 9 m of cable (art. no. 247660) Ambient conditions Ambient temperature -40 to +70 C -40 to +70 C Mechanical data Degree of protection IP43 IP42 Material Enclosure Aluminium ribbed and reinforced, protected cable duct Plastic, cable duct with rollers with stopper Return mechanism automatic, stopping device can be switched on and off Grounding cable 20 m oil and petrol resistant grounding cable, 3 x 1.5 mm Temperature range: -20... +90 C Connected 4-pole plug receptacle, IP67 9 m oil and petrol resistant grounding cable, 3 x 1.5 mm Temperature range: -20... +90 C Connected 4-pole plug receptacle, IP67 Weight approx. 14 kg with 20 m grounding cable approx 7.0 kg with 9 m grounding cable Fire resistance (UL 94) HB Mounting / Installation Mounting Wall mounting with mounting plate Wall mounting with mounting plate Connection 2.5 m, connection cable 3 x 1.5 mm 2 2.5 m, connection cable 3 x 1.5 mm 2 Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 124 [4,88] 98 [ 3, 86 ] 6 [ 0, 24 ] 225 [ 8, 86] ø 12 [ø 0,47] 124 [4,88] 98 [ 3, 86 ] 6 [ 0, 24 ] 225 [ 8, 86] ø1 2 [ø 0,47] 334 [13,15] 326 [12,83] 180 [ 7, 09 ] 334 [13,15] 326 [12,83] 180 [ 7, 09 ] 272 [ 10, 71] 325 [12, 79] 272 [ 10, 71] 325 [12, 79] 12758E00 12759E00 Single-channel grounding monitoring device 8485/111 Dual-channel grounding monitoring device 8485/112 Grounding Systems and s /5

Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 270,50 [10,65] 158 [6,22] 112,50 [4,43] 71 [2,80] 212 [8,35] Z Z 110 [4,33] 80 [3,15] 41,50 [1,63] 90 [3,54] ø 7 ø 7 [ ø 0,28] [ ø 0,28] Cable drum with automatic cable winder (Art. no. 247660) Clamp for order no. 240197, 238969, 238970, 238971) 17658E00 19119E00 Clamp for oder no. 247660, 247671, 247675 19141E00 /6 Grounding Systems and s

Dimensional Drawings (All Dimensions in mm [inches]) - Subject to Alterations 30 520 [20,47] 164 [6,46] 160 185 [7,28] 110 [4,33] 78 [3,07] 60 360 [14,17] Y 182 [7,17] ø10 [ ø 0,39] 75 [2,95] 150 [5,91] Y 20 [0,79] 40 [1,57] ø10,50 ø10,50 [ ø 0,41] [ ø 0,41] 40 [1,57] ø6,50 ø6,50 125,50125,50 54,50 [2,15] [4,94] [4,94] 160 Cable drum with automatic cable winder (order no. 247671) We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. 12053E00 Grounding Systems and s /7