This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy.

Similar documents
MIC-2 MKII Profibus module user s manual

Description of options. user s manual. DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: Fax:

MIC-2 MKII I/O module user s manual

DVPPF02-SL PROFIBUS DP Slave Communication Module

VersaMax IP Input Module

User s Manual DX1000/DX1000N/DX2000 PROFIBUS-DP (/CP1) Communication Interface

L5353 Profibus-DP Communications Interface

Universal Serial/PROFIBUS DP Gateway GT200-DP-RS User Manual V6.1 SST Automation

EM23-DIN COMMUNICATION PROTOCOL. Version 0 Revision 0

Manual Fiber Optic Interfaces

Installation and Setup

Gateway 1400 Reference Manual

Technical Manual. HA Issue 4. Copyright Parker SSD Drives, Inc 2008

MIC-2 MKII, Multi-instrument DATA SHEET

i-7550 PROFIBUS to RS-232/422/485 Converter User's Manual High Quality, Industrial Data Acquisition, and Control Products

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

Installation and Setup. In This Chapter... Installing the H0 PSCM The Profibus Network Configuring the Module

FOURSTAR PROFIBUS HUB. FS-PBHUB-4 FS-PBHUB-6 User Manual

MGate 4101-MB-PBS Series

MIC-2 Multi-instrument DATA SHEET

DIGITAL TRANSMITTER PROFIBUS Interface OPT-563B-70. Instruction Manual EN B

Serial PROFIBUS Interface

Modbus/ PROFIBUS DP Gateway PM-160

EM270 COMMUNICATION PROTOCOL. Version 1 Revision 0

Preface. Copyright 1997, Digital Electronics Corporation MS-DOS and Windows 95 are registered trademarks of the Microsoft Corporation.

Acuvim II Series Power Meter SNMP Protocol User's Manual

ABB Drives. User s Manual. Modbus Adapter Module RMBA-01

EM271 COMMUNICATION PROTOCOL. Version 0 Revision 0

PROFIBUS DP/CAN Gateway PCA-100. User Manual

SATEL I-LINK 100 MB I/O-converter User Guide, Version 1.1

GRAPHIC DIGITAL INDICATOR with PROFIBUS Interface CSD-912B-70. Instruction Manual EN

GNM3D Series COMMUNICATION PROTOCOL. Version 1 Revision 0

GRAPHIC DIGITAL INDICATOR

User Manual HMI Linkbox HL01 DP/MPI

RS485 MODBUS Module 6RO

The accessories described in this manual are of the highest quality, carefully designed and built in order to ensure excellent performance.

EM21 COMMUNICATION PROTOCOL. Version 1 Revision 0

DF PROFI II PCIe. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II PCIe KUNBUS

Anybus-CC CFW-11. User s Manual. Phone: Fax: Web: -

DF PROFI II CPCI. Installation Instructions V Project No.: 5302 Doc-ID.: DF PROFI II CPCI KUNBUS

PROFIBUS Products. ICP Electronics Australia Pty Ltd Overview P 5-1

RIK-5A Flexible Current Tranformer User's Manual

EM300 Series. ET300 Series

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Profibus DP slave. dual ported RAM 2Kbyte. Maximum length for I/O data. Maximum length for output data. Status display

EM24-DIN COMMUNICATION PROTOCOL. Version 3 Revision 1

EM24-DIN PFA, PFB & X models

Flexible Rogowski Coil Integrator Kit with 4-20mA and 0-20mA. User's Manual

USER S MANUAL. FX2N-32DP-IF Profibus-DP Interface Unit

VPGate Manual PROFIBUS to serial

EM210 COMMUNICATION PROTOCOL. Version 3 Revision 1

RS485 MODBUS Module 8AO

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

EM100 Series and ET100 Series

Protronic 100/500/550. Controllers for process engineering Controllers for industry. Digitric 500. PROFIBUS-DP interface and module

IFD9503. CANopen Slave Communication Module Application Manual

MU110-6U. Analog output module 6 channel. User guide

2. Terminal arrangement TEMPERATURE CONTROLLER KT2 COMMUNICATION INSTRUCTION MANUAL. (Fig. 2-1)

User Manual Gateway component for EtherNet/IP

The PROFIBUS and PROFINET Company. COMbricks Modules. Copyright 2013 PROCENTEC. All rights reserved.

EM210 COMMUNICATION PROTOCOL. Version 3 Revision 3

CAN485. Wall Mounting CAN to RS-485 Interface Converter. Support data conversion between 1 CAN port and 1 RS-485 serial port

RS485 MODBUS Module 8I8O

PB340 / PB306 / PB541

EL731 PROFIBUS INTERFACE

GW-7228 J1939/Modbus RTU Slave Gateway

PROFIBUS Interface WM : PD

SDM-8AO. Expansion Module 8 analog outputs. Manufactured for

INSTRUCTION MANUAL WCS-Interface Module, DeviceNet

MGate 5102-PBM-PN Series

Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160

COMMUNICATION CONVERTER FOR PROFIBUS

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

Serial Communications Accessories SITRANS RD200/300. Operating Instructions 05/2013 SITRANS

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

RS485 MODBUS Module 16I-M

VD SERIES CONTROLLERS (VERSION4.0) RS-485 COMMUNICATION INSTRUCTION MANUAL MODBUS Protocol Reference Guide

BCT SERIES CONTROLLERS (VERSION 3.0) RS-485 COMMUNICATION INSTRUCTION MANUAL MODBUS Protocol Reference Guide

EH-RIO IP67 Profibus-DP I/O modules

SDM-6RO. Expansion Module 6 relay outputs. Manufactured for

MXIO. Compact I/O module. Summary. Application Compact I/O module for data acquisition and HVAC control systems. Function

RMx621. Appendix to the operating manual

User Manual Revision English

User Manual Revision English

ProfiPro Distributed PROFIBUS I/O Modules User Manual

The following conventions are used to indicate precautions in this manual.

BNI PBS Z001 BNI PBS Z001 BNI PBS Z001. Quick start guide

EY-CM 721: Communication module with EIA-232 and EIA-485 interfaces, modu721

EM24-DIN COMMUNICATION PROTOCOL. Version 3 Revision 0

RMx621 /FML621. Appendix to the operating manual

ZLAN5443A. User Manual

RS 485 Mini Modbus 1AO

Table of Contents 1 ABOUT THIS DOCUMENT GENERAL COPYRIGHT INFORMATION TERMS ABOUT THE GATEWAY PRODUCT FUNCTIO

270 MHz Control Modules

MOVITRAC 31.. Frequency Inverter

GW-7553-CPM PROFIBUS/CANopen GATEWAY. User's Manual

Siemens Spares. Preface 1. Scope of Delivery 2 SIPLUS CMS4000. Product Characteristics 3 ION PROFIBUS DP SPY T001 Installation and Maintenance 4

DKM-407 DIN RAIL TYPE NETWORK ANALYZER

ADAM-4510 RS-422/RS-485 Repeater ADAM-4510S Isolated RS-422/485 Repeater ADAM-4520 Isolated RS-422/485 Converter Startup Manual

I-7550E PROFIBUS/Ethernet Converter. User's Manual

Transcription:

Copyright 2008 V1.10 This manual may not be reproduced in whole or in part by any means, without written permission of Accuenergy. The information contained in this document is believed to be accurate at the time of publication, however, Accuenergy assumes no responsibility for any errors which may appear here and reserves the right to make changes without notice. Please ask the local representative for latest product specifications before ordering.

Please read this manual carefully before dong installation, operation and maintenance of Acuvim II meter. Following symbols are used in this user s manual and on Acuvim II meter to alert the dangerous or to prompt in the operating or set process. Dangerous symbol, Failure to observe the information may result in injury or death. Alert symbol, Alert the potential dangerous. Observe the information after the symbol to avoid possible injury or death. Focus symbol, avoid inadvertent operations which may lead to abnormal working of instrument,even damage to the instrument or physical harm. This mark is on product for UL Listed product Installation and maintenance of the Acuvim II meter should only be performed by qualified, competent personnel that have appropriate training and experience with high voltage and current device. This document is not fit for any untrained people. Accuenergy is not responsible for any problem happens under proper operation. II

Content Chapter 1 Introduction------------------------------------------------------------------1 1.1 Introduction of PROFIBUS Technology---------------------------------2 2.2 Application points of PROFIBUS module--------------------------3 Chapter 2 Wiring and hardware configuration--------------------------------------5 2.1 Appearance and Dimensions-----------------------------------------6 2.2 Installation Method------------------------------------------------------7 2.3 Definition of DP Interface-----------------------------------------------8 2.4 Cable-----------------------------------------------------------------------9 2.5 Bus Terminal--------------------------------------------------------------9 Chapter 3 Application of PROFIBUS DP Protocol----------------------------------11 3.1 Address Setting----------------------------------------------------------12 3.2Baud Rate-----------------------------------------------------------------13 3.3 GSD Files-----------------------------------------------------------------13 3.4 Information Exchange--------------------------------------------------14 3.5 Format of function code 01H -----------------------------------------15 3.6 Format of function code 05H -----------------------------------------16 3.7 Format of function code 02H------------------------------------------17 3.8 Format of function code 03H------------------------------------------19 3.9 Format of function code 10H------------------------------------------21 Appendix ---------------------------------------------------------------------------------25 Appendix A Technical Data and Specifications---------------------------------------26 Appendix B Ordering Information------------------------------------------------------27 Appendix C Revision history------------------------------------------------------------28 III

Starting! This manual is about PROFIBUS module of Acuvim II meter. With PROFIBUS module, Acuvim II meter can be linked to PROFIBUS network easily, and it can realize distribution automation based on field bus. Please read this manual carefully before operating and setting the Acuvim II meter to avoid unnecessary trouble. Chapter 1 helps you to understand the fundamental concept of PROFIBUS, and application points of PROFIBUS module. Chapter 2 describes in detail hardware features of PROFIBUS module. Chapter 3 describes in detail software application of PROFIBUS module. Appendix lists technical data and specifications and ordering information of PROFIBUS module. IV

Chapter 1 Introduction Introduction of PROFIBUS Technology Application points of PROFIBUS module 1

PROFIBUS module is an extended communication module of Acuvim II meter. With PROFIBUS module, Acuvim II meter can be linked to PROFIBUS network easily. 1.1 Introduction of PROFIBUS Technology PROFIBUS(Process Field bus)is an international field bus standard which is widely used in automation technology of manufactures and flow industry. It is a widely used, open digital communication system, which is suitable for high-speed, time-critical, and high reliability communications. PROFIBUS is one kind of open style field bus standard which promotes by SIEMENS Corporation, in 1989 became German standard DIN19245, in 1996 became European standard EN50170, in 1999 is December accepted for an international standard IEC61158 part, in 2001 became China national standard JB/T 10308.3-2001 for field bus of machinery industry controlling system. PROFIBUS has provided 3 kinds of agreements types: PROFIBUS-DP (Decentralized Periphery), PROFIBUS-PA (Process Automation) and PROFIBUS-FMS (Field bus Message Specification). ALL of types are follow the same protocol. With optimized, high-speed, low-cost communications links, PROFIBUS- DP is specially used in automatic controlling systems and equipment level decentralized I / O communication, it can meet real-time response, stability and reliability of equipment level and distributed controlling system. The PROFIBUS module uses PROFIBUS-DP(V0)protocol.

1.2 Application points of PROFIBUS module Please read appendix of technical data and specifications of PROFIBUS module before using it. In addition, please read Acuvim II manual too, especially the communication addresses of MODBUS protocol, which are the communication addresses for PROFIBUS module too. * The PROFIBUS module can only be used as slave in PROFIBUS network. Its slave address is ranged from 0 to 126, which can only be set by the panel. If the address is changed, it will take effect immediately. * The PROFIBUS module s baud rate can be adaptive between 9.6Kbps to 12Mbps in PROFIBUS network. * The PROFIBUS module s hardware connection method should be accurately known, otherwise there will be troubles in debugging and using. * Please read GSD file of the PROFIBUS module carefully before using it, which contains much technology information such as device name, ID number and so on. * Please read and understand the communication data format, which is the key point of PROFIBUS module. * The simple example of PLC as a master will be useful to understand application characteristics of PROFIBUS module.

Chapter 2 Wiring and hardware configuration Appearance and Dimensions Installation Method Definition of DP Interface Cable Bus Terminal 5

PROFIBUS module must be linked to Acuvim II meter when it is to be used. In addition, PROFIBUS module must be the first extended module linked to Acuvim II meter. Note The environment temperature and humidity should fulfill the requirement of AcuvimII meter. Otherwise it may cause the meter damage. 2.1 Appearance and Dimensions 90mm 55.6mm (Top View)

(Bottom View) 22mm 2.2 Installation Method (Side View) PROFIBUS is linked to Acuvim II meter by communication plug. It can also

be linked to other extended modules such as IO modules. 1. Insert the installation clips to the counterpart of Acuvim II meter, and then press the PROFIBUS module lightly, so linking is established. 2. Tighten the installation screw. Note: 1. lightly in installation or it may cause damage to the PROFIBUS modules; 2. Installation with power is forbidden. 2.3 Definition of DP Interface The PROFIBUS module uses standard 9-pin D-type connector to access PROFIBUS network. The mechanical and electrical characteristics of connector are consistent with the requirements of IEC 807-3. The connector of PROFIBUS is a socket, and the counterpart connector of cable is a plug. Connector pins are distributed as follows: Pins RS-485 ID Content Dose PROFIBUS use or not 1 SHIELD Power GND NO 2 N24V -24V Output NO 3 B RXD/TXD-P Data P(Receive /Send) YES 4 CNTR-P Controlling P YES 5 C DGND Digital Ground YES 6 Vp Positive Voltage YES 7 P24V +24V output NO 8 A RXD/TXD-N Data N(Receive /Send) YES 9 CNTR-N Controlling N NO Note: 4 pin is used for RTS controlling, TTL, it is not necessary.

2.4 Cable Shielded twisted pair cable is usually recommended as reference to the EIA RS-485 standard. In addition, if the interference is not serious, nonshielded twisted pair cable can also be used. 2.5 Bus Terminal Based on DP standard, the first station and the last station in PROFIBUS- DP network should connect bus terminal (resistor), and it is not necessary for other stations, as shown in below figure. STATION 3 STATION 4 P N P N Vp Vp 390Ω 390Ω P P STATION 1 220Ω 220Ω STATION 2 N N 390Ω 390Ω DGND DGND Connection of many DP stations The bus terminal is composed of three resistors and connection wire, where Vp is the supply positive voltage and DGND is the Digital Ground. When the bus is idle, the bus terminal makes the data P level higher than data N, so the bus s idle signal is always 1.

10

Chapter 3 Application of PROFIBUS DP Protocol Address Setting Baud Rate GSD Files Information Exchange Format of function code 01H Format of function code 05H Format of function code 02H Format of function code 03H Format of function code 10H 11

3.1 Address Setting The PROFIBUS module can only be used as slave in PROFIBUS network. Its slave address is ranged from 0 to 126, which can only be set by the panel (in SYS sub menu of Acuvim II Setting menu). If the address is changed, it will take effect immediately. Figure bellow shows the address setting of PROFIBUS module. Address setting of PROFIBUS module 12

3.2 Baud Rate The PROFIBUS module s baud rate can be adaptive between 9.6Kbps to 12Mbps in PROFIBUS network. 3.3 GSD Files PROFIBUS-DP master can exchange data with various slave stations. In order to identify various slave stations safely and conveniently, it is necessary to obtain the technical data of slave stations. The file where the technical data are described is called Device Description Data File (GSD). Because of the importance of GSD file, please read it carefully before using the PROFIBUS module. The GSD file is provided in pure text format with detailed comments. * As a DP slave station, the PROFIBUS module support protocol of V0 revision. * The PROFIBUS module s data interface is a 16 words input/output interface. It is a rule requirement higher than specific protocol. * The slave address of PROFIBUS module can be set by the panel. If the address is changed, it will take effect immediately, and there is no need to be powered on again. 3.4 Information Exchange There are a lot of information of Acuvim II meter can be transmitted by the PROFIBUS module, such as electrical quantities and other parameters. There are various protocols to counterpart with various types of information. The basic communication method of Acuvim II meter is 13

RS-485, which uses protocol of MODBUS-RTU. In order to use the same address lists as MODBUS-RTU, the communication formats of PROFIBUS- DP is categorized in the same way as MODBUS-RTU. It is recommended to read communication part of Acuvim II meter s manual at the same time of reading this part. If you have read communication address lists of MODBUS-RTU, you can find something as follows: 1. There are various function codes, such as 01H, 02H,03H, 05H,10H, for the various categorized parameters. Different function codes have different formats of query and response frames. 2. There is a specific relationship between numerical value in register of Acuvim II meter and the real physical value. 3. Different parameters may have different data length and data type. These three points are also suitable for the PROFIBUS-DP protocol in PROFIBUS module. Note: the following communication formats is suitable for the application data, but not for the PROFIBUS-DP s frame characteristic data. Function codes, such as 01H, 02H and 03H, are inquiry commands. For users to quickly switch the inquiry contents, we define 8 channels named 1 to 8, in order to update data more quickly. 3.5 Format of function code 01H Function code 01H is used to read relay status in MODBUS-RTU. In PROFIBUS-DP, the format of function code 01H is defined as follows: 14

Query: Frame Bytes Caption Byte1 Channels can be chosen from 1 to 8 Byte2 01H Byte3 starting address high byte Byte4 starting address low byte Byte5 quantity of coils high byte Byte6 quantity of coils low byte Byte7~32 0 Because 16 words are required for IO data in GSD file, all other bytes after Byte7 are set to 0. Response It is the information that slave stations response to master. Frame Bytes Caption Byte1 The channel of inquiry frame Byte2 01H Byte3 byte count Byte4 coil status Byte5~32 0 The coils in the response message are packed as one coli per bit of the data field. Status is indicated as 1=ON and 0=OFF. The LSB of the first data byte contains the output addressed in the query. The other coils follow toward the high order end of this byte, and form low order to high order in subsequent bytes. Example: reading Relay1 and Relay2 states (start register address is 0000H). Use 4 channels. Query 15

Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7~32 04H 01H 00H 00H 00H 02H 00H Response Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7~32 04H 01H 01H 02H 00H 00H 00H Coil Status 7 6 5 4 3 2 1 0 0 0 0 0 0 0 1 0 MSB ( Relay 1 = OFF,Relay 2=ON ) LSB 3.6 Format of function code 05H The message with function code (05H) in MODBUS-RTU forces a single relay either on or off. The data value FFOOH will set the relay on and the value 0000H will turn it off. All other values are illegal and will not affect that relay. In PROFIBUS-DP, the format of function code 05H is defined as follows: Query 16 Frame Bytes Caption Byte1 FAH Byte2 05H Byte3 outputs address high byte Byte4 outputs address low byte Byte5 outputs value high byte Byte6 outputs value low byte Byte7~32 0 Note: Because PROFIBUS-DP V0 exchanges information data periodically,

so controlling information such as function code 05H should be used carefully. Response The normal response to the command request is to retransmit the message as received after the relay states has been altered. Frame Bytes Caption Byte1 FAH Byte2 05H Byte3 outputs address high byte Byte4 outputs address low byte Byte5 outputs value high byte Byte6 outputs value low byte Byte7~32 0 Example: setting Relay2 on. Query Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7~32 FAH 05H 00H 01H FFH 00H 00H Response Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7~32 FAH 05H 00H 01H FFH 00H 00H 3.7 Format of function code 02H Function code 02H is used to read DI status in MODBUS-RTU. In PROFIBUS- DP, the format of function code 02H is defined as follows: Query Frame Bytes Caption 17

Response Byte1 Channels can be chosen from 1 to 8 Byte2 02H Byte3 starting address high byte Byte4 starting address low byte Byte5 quantity of digital inputs high byte Byte6 quantity of digital inputs low byte Byte7~32 0 Frame Bytes Caption Byte1 The channel of inquiry frame Byte2 02H Byte3 byte count Byte4 inputs status1 Byte5 inputs status2(or 0) Byte6 inputs status3(or 0) Byte7 inputs status4(or 0) Byte8~32 0 The digital inputs in the response message are packed as one input per bit of the data field. Status is indicated as 1=ON; 0=OFF. The LSB of the first data byte contains the input addressed in the query. The other inputs follow toward the high order end of this byte, and from low order to high order in subsequent bytes. Example: reading 4 DI statuses (starting address is 0000H). Use 6 channels. Query Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7~32 06H 02H 00H 00H 00H 04H 00H Response Byte1 Byte2 Byte3 Byte4 Byte5~32 06H 02H 01H 06H 00H 18

DI status 7 6 5 4 3 2 1 0 0 0 0 0 0 1 1 0 MSB ( DI1 = OFF,DI2=ON,DI3 = ON, DI4 = OFF ) LSB 3.8 Format of function code 03H This function code is used in MODBUS-RTU to read the contents of a contiguous block of holding registers in Acuvim II meter. In PROFIBUS-DP, the format of function code 03H is defined as follows: Query Frame Bytes Caption Byte1 Channels can be chosen from 1 to 8 Byte2 03H Byte3 starting address high byte Byte4 starting address low byte Byte5 quantity of registers high byte Byte6 quantity of registers low byte Byte7~32 0 Quantity of registers tells that how many words will be read. Response Frame Bytes Byte1 Byte2 Byte3 Byte4 Byte5 Caption The channel of inquiry frame 03H byte count Register value1 high byte Register value1 low byte 19

Byte6 Byte32 Byte count tells that how many bytes will be read. The register data in the response message are packed as two bytes per register, with the binary contents right justified with each byte. For each register, the first byte contains the high order bits and the second contains the low order bits. There is one important thing should be noted. The response frame has 16-word, so the maximum quantity of registers should less than 15. Otherwise, it will return error result. Example: reading 3 measured data (F,V1,V2) from Acuvim II meter. The data address of F includes 4000H and 4001H. The data address of V1 includes 4002H and 4003H. The data address of V2 includes 4004H and 4005H. (Use 7 channels) Query Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7~32 07H 03H 40H 00H 00H 06H 00H Response Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Byte8 07H 03H 0CH 42H 48H 00H 00H 42H Byte9 Byte10 Byte11 Byte12 Byte13 Byte14 Byte15 Byten16~32 C7H CCH CDH 42H C8H 33H 33H 00H (F=42480000H(50.00Hz), V1=42C7CCCDH(99.9v), V2=42C83333H(100.1v)). 20

Note: the relationship between numerical value in register of Acuvim II meter and the real physical value is described in detail in communication part of Acuvim II manual, so it will not be described here. 3.9 Format of function code 10H This function code is used in MODBUS-RTU to write a block of contiguous registers in Acuvim II meter, such as system parameters setting and so on. In PROFIBUS-DP, the format of function code 10H is defined as follows: Query Frame Bytes Caption Byte1 FAH Byte2 10H Byte3 starting address high byte Byte4 starting address low byte Byte5 quantity of registers high byte Byte6 quantity of registers low byte Byte7 byte count Byte8 register value 1 high byte Byte9 register value 1 low byte Byte10 register value 2 high byte Byte11 register value 2 low byte Byte32 0 Quantity of registers tells that how many words will be written. Byte count tells that how many bytes will be written. If quantity of register is N, then byte count is (Nⅹ2). 21

There is one important thing should be noted. The response frame has 16-word, so the maximum quantity of registers should less than 13. Otherwise, it will return error result. Response The normal response returns the function code, starting address, and quantity of registers written. Frame Bytes Caption Byte1 FAH Byte2 10H Byte3 starting address high byte Byte4 starting address low byte Byte5 quantity of registers high byte Byte6 quantity of registers low byte Byte7~32 0 Example: presetting import active enengy (EP_imp) to 17807783.3Kwh. Based on the relationship between the register value and the physical value, we can get that the register value in hex is 0A9D4089H. The data address of EP_imp includes 4048H and 4049H. Query 22 Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7 Byte8 FAH 10H 40H 48H 00H 02H 04H 0AH Byte9 Byte10 Byte11 yte12~32 9DH 40H 89H 00H Response Byte1 Byte2 Byte3 Byte4 Byte5 Byte6 Byte7~32 FAH 10H 40H 48H 00H 02H 00H

Example Projects To facilitate your understanding of the use of PROFIBUS module, we purposely develop a PLC-based DEMO engineering application program. Please read DEMO procedure documentation for the specific information. 23

24

Appendix Appendix A Technical Data and Specifications Appendix B Ordering Information Appendix C Revision History 25

Appendix A Technical data and specification Standards Protocol Standard JB/T 10308.3-2001 EN50170 Environmental IEC 60068-2-30 Safety IEC 61010-1 Communication Port Physical Layer Protocol Baud Rate standard DB9 socket with optical isolation PROFIBUS-DP V0 9.6k~12M bps Suitable Condition Dimensions Weight Operating Temperature Storage Temperature Humidity Power Supply Power Consumption 90X55.6X22 (mm) 65g -25ºC~70ºC -40ºC~85ºC 5%~95% non-condensing DC 5V(supplied by Acuvim II meter) 1W 26

Appendix B Ordering Information Type: AXM-PROFI 27

Appendix C Revision History Revision Date Description 1.0 20070915 First version 1.10 20080915 We enhance the channel management of the inquiry commands, so it will cause the incompatiblility of the formal version. 28