Operating Instruction for Turbine-wheel Flow Meter. Model: DRB-...

Similar documents
Operating Instruction for Rotating Vane Flow Meter. Model: DRG-...

Operating Instruction for Turbine-wheel Flow Meter. Model: DRS

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Rotating Vane Flow Meter. Model: DRH-...

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DPL-1P... DPL-1V... DPL-1E...

Operating Instructions for Low Volume Rotating Vane Flow Meter. Model: DTK

Operating Instructions for Turbine Wheel Flow Meter. Model: TUR

Operating Instruction for rotating vane flow meter Model: DPM-...

DPE. Turbine Wheel Flowmeter. for liquids. Measuring ranges: l/min water. Measuring accuracy: ± 2.5 % of full scale

Operating Instructions for Level Switch for Liquids. Model: RFS

Operating Instructions for Digital Thermometers. Model: DTM

Operating Instructions for Vibrating Level Switches. Model: NVI

Operating Instructions for Differential Pressure Sensor. Model: PMP

Turbine Wheel Flow Meter/ Monitor for Liquids

Operating Instructions for Turbine Wheel Flow Meter Model: TUR

Operating Instructions for Evaluation Electronics. Model: ZED-K and DF- KLxxx

Operating Instructions. Power Supply & Isolation Relay for Switches Model: RL manual_rl-5900_0215

Level sensor Stainless steel version Model RLT-1000, for industrial applications

Operating Instructions. Power Supply & Latching Relay For Switches Model: RL manual_rl-6000_1016

DRH. Paddle Wheel Flow Sensor

Operating Instructions. Isolation Relay for Switches Model: RL manual_rl-6100_1116

Operating Instruction Supplement for Compact Electronics. Model:..C30R;..C30M..C34P;..C34N

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Compact Vortex Flow Meter for Low Viscosity Liquids

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

DVZ - Vortex Flowmeter and Switch

QVE3000.0xx QVE3100.0xx. Flow sensor. for liquids in DN10 25 pipes

Instruction Manual DR58 Brass Paddle Wheel Flow Meter

DRS. OEM Turbine Flow Sensor. for Liquids

Insertion Flowmeter for compressed air and gases DN50 - DN700 (2-28 )

PKP Prozessmesstechnik GmbH. Borsigstrasse 24. D Wiesbaden-Nordenstadt. Tel: / Fax: / Operating manual PSA06

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

DRH. Paddle Wheel Flow Sensor

THERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA

C-Flow Coriolis Mass Flow Meter

Operating Instructions VEGAMET 381

Immersion Temperature Sensors

Electro-Mechanical Counters

Viscosity-Compensated Flow Meters and Switches

Temperature Switches

Operating Instructions for Evaluation Electronics. Model: ZED-K and DF- KLxxx

Operating Instructions. For. Level Control Module. Model SSR 1000

Operating Instructions for Counter Electronic Model: ZED-Z. or DF- ZLxxx or Model- ExxR

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

InCos-P Pressure sensor 20 Pa Pa

DCT 531. Industrial Pressure Transmitter with RS485 Modbus RTU. Stainless Steel Sensor

JUMO PINOS L01. Calorimetric flow sensor. Brief description. Special features. Customer benefits. Data Sheet

Intrinsically safe batch controller Batching Master 110i

Flow sensors SFAM Key features

accurate measurement of compressed air consumption and leakage detection Calibration certificates and continous calibration, OEKD calibration service

Level and temperature switch Nivotemp NT-M, NT-MD

SonoMeter 30 Ultrasonic energy meter for heating and cooling applications

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

Operating Instructions for Hand-held Conductivity Measuring Units. Model: HND-C110

standard, short, preferential, top

Inductive sensor NI3-EG08K-Y1-H1341

Flow. Flow. N/en

Switch on / off. For switching off please press button for approx. 5 sec.

Solenoid Valves PN16 for gas flow interception

Flow sensors SFAB Key features

Electronic Temperature Controller. Instruction Manual Version

EE771 Series. Flowmeter for compressed air and gases in Industrial Applications. EE771 Compact. EE771 remote probe

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Operating pressure (bar) kv factor (m 3 /h) *3)

LS 6600 Technical Datasheet

Electronic pressure switch with display Model PSD-4

MAXIMA+ Series Rotary Level Indicator

DMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial

Operating Instruction

Operating Instructions for Dosing Electronic. Model: ZED-D. or DF- DLxxx or Model- GxxR

Liquipoint T FTW 31, FTW 32 Level limit switch for multiple point detection in conductive liquids

Instruction Manual. EXDC Turbomolecular Pump Drive Modules. Item Number

Inductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933

D Issue A. Instruction Manual. Active Strain Gauge

Ei. nano Inox DATA SHEET. Part number: 9NI-01xx/01x 임펠러유량계 SWITZERLAND SWITZERLAND

FlowJam Plus. Superior with Solids. Material flow monitor with blockage detector. Operating instructions

Series 95000, 2/2 Direct solenoid actuated poppet valve

Flow Sensor SONOFLOW CO.55

Inductive sensor BI1.5-EG08-Y1-H1341

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Material Seat seal. N/en

Level switch NS 10/NS 25..-AM

Installation, Operation & Maintenance Instructions / Technical Document

Operation Manual SRZ Helical Flow Meters

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

RTT2 ROOM TEMPERATURE SWITCH. Mounting and operating instructions

CombiTemp TFRN/TFRH. Operating instructions. Temperature sensor. Operating Instructions: EN.

Assembly. 1 Compact version with valve plug 2 Short tube version with cable 3 Compact version with M12 plug 4 Short tube version with M12 plug

MAXIMA + Series ROTARY LEVEL CONTROL

RoHS. High shaft load capacity. Shock / vibration resistant

Miniaturised pressure sensor Model M-10, standard version Model M-11, version with flush diaphragm

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

Absolute Encoders Multiturn

Level measurement. Applications. Special features. Description

FHKU G1/2 100 Arnite Part number: /01

Inductive proximity switches with long operating distance, series 500

Tachometer Panel, PE3

Liquiphant T FTL20. Technical Information. Level limit switch for liquids

Pressure sensor For highest pressure applications to 15,000 bar Model HP-2

Transcription:

Operating Instruction for Turbine-wheel Flow Meter Model: -...

1. Contents 1. Contents... 2 2. Note... 3 3. Instrument Inspection... 3 4. Regulation Use... 3 5. Operating Principle... 4 6. Mechanical Connection... 4 7. Electrical connection... 7 8. Commissioning Evaluation Electronics... 10 9. Maintenance... 10 10. Technical Data... 11 11. Order Details... 14 12. Dimensions (mm)... 15 13. EU Declaration of Conformance... 18 Manufactured and sold by: Kobold Messring GmbH Nordring 22-24 D-65719 Hofheim Tel.: +49(0)6192-2990 Fax: +49(0)6192-23398 E-Mail: info.de@kobold.com Internet: www.kobold.com Page 2 K04/0318

2. Note Please read these operating instructions before unpacking and putting the unit into operation. Follow the instructions precisely as described herein. The devices are only to be used, maintained and serviced by persons familiar with these operating instructions and with the prevailing regulation applying to safety and the prevention of accidents. When used in machines, the measuring unit should be used only then when the machines fulfil the EC-machine guide lines. PED 2014/68/EU In acc. with Article 4 Paragraph (3), "Sound Engineering Practice", of the PED 2014/68/EU no CE mark. Table 8, Pipe, Group 2 dangerous fluids 3. Instrument Inspection These devices are checked before shipping and sent out in perfect condition. Should damage to a device be visible, we recommend a thorough inspection of the delivery packing. In case of damage, please inform your parcel service/ forwarding agent immediately, since they are responsible for damages during transit. Scope of delivery: Turbine-wheel Flow Meter, Model: Operating Instructions 4. Regulation Use The turbine-wheel flow meter, model, is to be installed only in specified applications. Any usage which exceeds the specifications is considered to be nospecified, and would also invalidate the warranty. Any damages resulting therefrom are not the responsibility of the manufacturer. The user assumes all risk for such usage. The application specifications include the installation, start-up and service requirements specified by the manufacturer. K04/0318 Page 3

5. Operating Principle The KOBOLD flow meter model is used for measuring and monitoring liquids. The device works according the well-known paddle wheel principle. The four vane paddle wheel is retained radially in a high quality sapphire bearing. The sensor is supplied ready-to-install with pipe fittings or with weld-on sleeves. The paddle wheel is set in motion by the flowing medium. Magnets are embedded hermetically sealed in the ends of the blades. The magnets generate electrical pulses in a Hall-effect sensor mounted outside the flow area. Various electronics units can be used to display and monitor the volumetric flow. 6. Mechanical Connection 6.1. Examine operating conditions: Flow volume Max. operating pressure Max. operating temperature Ensure that they are all within the limits of the device Attention! Over-ranging may cause bearing damage and considerable measurement errors. 6.2. Installation Flow in the direction of the pointing arrow (position independent) Pressure and tensile loading should be avoided The inlet and outlet should be secured at a distance of 50 mm mechanically from the connection. Check the sealing of connections/joints Page 4 K04/0318

6.3. Inlet and outlet path straight piping requirements P 2 x 90 - elbow 3 - dimensional P Control valve 50 x D 5 x D 40 x D 5 x D P P 2 x 90 - elbow 90 - elbow or T - piece 25 x D 5 x D 20 x D 5 x D P P Extention Reduction 18 x D 5 x D 15 x D 5 x D K04/0318 Page 5

Version with weld-on mounting adapter Weld the mounting adapter in the piping according to the sketch given below. Nominal Size H DN 25 30 DN 40 44 DN 50 46 DN 80 63 Position and weld-in the mounting adapter according to the nominal diameter suitable marking. The marking on the adapter must be in line with the outer diameter of the pipe. Also pay attention to the later position of the rotating vane (shaft of the vane shifted by 90 to the direction of flow). for DN 40 for DN 80 for DN 50 51 Adapter Ø ± 0,3 H Nominal diameter Page 6 K04/0318

7. Electrical connection 7.1. General Attention! Make sure that the power supply voltage corresponds with the voltage requirement of the flow meter. Ensure that power supply is de-energized Connect the power supply and the output signal to the plug-pins, as shown below. We recommend a cross-section of 0.25 mm² for the power supply cable. Attention! Incorrect wiring may cause permanent damage to the sensor. K04/0318 Page 7

7.2. Output Electronics: Frequency output (..F300;..F320,..F340) n.c. 2 1 +Vs GND 3 4 Signal Out 7.3. Output Electronics: Analogue output (..L303,..L342,..L343,..L442) 3-wire (..L303,..L343) +Vs n.c. 2 1 +Vs GND GND 3 4 Signal Out 2-wire (..L342) +Vs n.c. 2 1 S+ GND n.c. 3 4 S- Page 8 K04/0318

2-wire, DIN-plug (..L442) +Vs GND S- PE 2 3 n.c. 1 S+ 7.4. Compact Electronics: (..C30R,..C30M,..C34P,..C34N) see Instruction Manual-Supplement for Compact Electronics 7.5. Evaluation electronics: Pointer indication (..Z300,..Z340) +Vs n.c. 2 1 +Vs GND GND 3 4 Signal Out Caution! If the current output is not needed, PIN 4 (signal out) shall be permanently connected to ground (GND) (short circuit). K04/0318 Page 9

7.6. ADI electronics see Instruction Manual-Supplement for ADI-electronics 8. Commissioning Evaluation Electronics 8.1. General The Measuring units factory are pre-set and are ready for use after electrical connections are made. 8.2. Adjustment Compact electronics see Instruction Manual-Supplement for Compact electronics with Frequency output 8.3. Adjustment ADI display/controller see Instruction Manual-Supplement for ADI-series display/controller 9. Maintenance The measuring unit is maintenance-free if the medium to be measured does not cause deposition of impurities. In order to avoid problems, we recommend installation of a filter, such as magnet filter, model MFR. Should cleaning of the sensor becomes inevitable, after opening the sensor the inner parts may be accessed. Note the direction that the turbine points during removal and re-install in the same direction. Please be careful to avoid any damage to the sensor and in particular, to the turbine blades. Repair work regarding electronics may only be carried out by the supplier. Any access or work on the electronics voids the warranty. Page 10 K04/0318

10. Technical Data 10.1. Sensor data Measuring range: 50-30...50-750 L/min Water Measuring accuracy: ±3% of. f.s. Process temperature: max. 80 C Ambient temperature: max. 80 C Max. operating pressure: PN 16 / 20 C Max. pressure loss: -...05: 0.05 bar -...10. -..15: 0.03 bar -...20: 0.04 bar -...25: 0.02 bar -...30: 0.01 bar Protection: IP65 Materials Housing: brass casting st. steel 1.4581 st. steel 1.3955 (...W) Sealings: brass casting version: NBR st. steel version: FPM Turbine-wheel: PVDF Axle: hard metal (-11... and -12...) ceramic (-1300...) Bearing: ceramic (-11... and -12...) ceramic/peek (-1300...) 10.2. Evaluation electronics Frequency output (F...300) Power supply: Power consumption: Pulse output: Electrical connection: 12 28 V DC 10 ma PNP, open collector, max. 25 ma plug connector M12x1 Frequency output with frequency divider Power supply: 24 V DC ±20 % Power consumption: 15 ma Pulse output: PNP, open collector, max. 25 ma Electrical connection: Plug M12x1 Division ratio: 1...1/128, factory set K04/0318 Page 11

Analogue output (plug-on display option) Power supply: 24 VDC ±20% Output: 0-20 ma or 4-20 ma, 2-wire or 3-wire Max. load: 500 Ω Electrical connection: plug connector M12x1 or DIN 43 650 Option: plug-on display (with plug connection DIN 43 650, 2-wire) Compact electronics Display: Analogue output: Switching outputs: Contact operation: Setting: Supply: Electrical connection: 3-segment LED (0)4-20 ma adjustable, max. 500 W 1 (2) semiconductor PNP or NPN, factory set N/C / N/O contact programmable with 2 buttons 24 VDC ±20%, 3-wire technology, approx. 100 ma plug connector M12x1 Pointer indication with analogue output Housing: Aluminium Display: moving-coil instrument, 240 display Power supply: 24 VDC ±20 % Output: 4-20 ma or 0-20 ma/0-10 V, 3-wire Max. load: Electrical connection: 250 Ω plug connector M12x1 ADI electronics Display: bar graph, 5-digit digital display; batching unit Analogue output: (0)4...20 ma, 0-10 V DC 2 switching outputs: relay/changeover contact max. 250 VAC/5 A resistive load, max. 30 VDC/5 A Setting: with 4 buttons Power supply: 100...240 VAC ±10% or 18...30 V AC /10...40 V DC Electrical connection: pluggable terminal block via cable gland Page 12 K04/0318

-...Exxx (Counter elektronic) Display: LCD, 2 x 8 digit, illuminated total, part and flow quantities units selectable Analogue output: 0(4)...20 ma adjustable Load: max. 500 Ω Switching output: 2 relays, max. 250 V / 5 A /1000 VA Settings: via 4 buttons Functions: reset, MIN/MAX memory, flow monitor, monitoring for part and total quantity, language Power supply: 24 VDC ± 20 %, 3-wire Power consumption: approx. 170 ma Electrical connection: pluggable terminal block via cable gland -...Gxxx (Dosing electronic) Display: LCD, 2 x 8 digit, illuminated total, part and flow quantities units selectable Analogue output: 0(4)...20 ma adjustable Load: max. 500 Ω Switching output: 2 relays, max. 250 V / 5 A / 1000 VA Settings: via 4 buttons Functions: dosing (relay S2), start, stop, reset, fine dosing, correction amount, flow switch, total quantity, language Power supply: 24 VDC ± 20 %, 3-wire Power consumption: approx. 170 ma Electrical connection: pluggable terminal block via cable gland K04/0318 Page 13

11. Order Details example: -1105 G4 F300 Measuring range max. 3 m/s app. (L/min frequency water) (Hz) f. s. Flow rate max. 10 m/s (L/min water) With pipe fitting Mat. brass casting Model Material st. steel Standard fem. Thread Connection Special fem. thread 5-30 40 100-1105.. -1205....G4..= G 1/2..N4..= 1/2 NPT 10-50 40 180-1110.. -1210....G5..= G 3/4..N5..= 3/4 NPT 20-80 65 230-1115.. -1215....G6..= G 1..N6..= 1 NPT 25-250 85 600-1120.. -1220....G8..= G 1 1/2..N8..= 1 1/2 NPT 30-350 80 1000-1125.. -1225....G9..= G 2..N9..= 2 NPT 50-750 70 1600-1130.. -1230....GB..= G 3..NB..= 3 NPT Meas. range (m/s) 0.7-3 0.3-3 0.3-3 0.2-3 approx. frequency (Hz) at max. value Max. flow rate (m/s) With installation adapter not available with compact or ADI electronics Model Material 1.3955 axle hard metal Material 1.3955 axle ceramic 50 (at DN 25) 85 (at DN 40) 80 (at DN 50) 70 (at DN 80) 10-1200.. -1300.. *Please specify flow direction in writing Connection for nominal pipe size..w6.. = DN 25..W8.. = DN 40 / DN 50..WB.. = DN 80 Evaluating electronics Frequency output..f300= Frequency output, plug connector M12x1..F320= Frequency divider 1:2 plug connection M12x1..F340= Frequency divider 1:4, plug connector M12x1..F390= Frequency divider 1 1 /128 plug connector M12x1 Analogue output..l303= 0-20 ma output, 3-wire, M12x1 plug connector..l342= 4-20 ma output, 2-wire M12x1 plug connector..l343= 4-20 ma output, 3-wire, M12x1 plug connector..l442= 4-20 ma output, 2-wire, plug connection DIN EN 175301 Compact electronics*..c30r= LED display, 2xOpen Collector, PNP, plug connector M12x1..C30M= LED display, 2xOpen Collector, NPN, plug connection M12x1..C34P= LED display, 4-20 ma, 1x Open Collector PNP, plug connector M12x1..C34N= LED display, 4-20 ma, 1xOpen collector NPN, plug connector M12x1 Pointer indication, 240 *..Z300= 240 pointer indication, 0-20 ma, plug connector M12x1..Z340= 240 pointer indication, 4-20 ma, plug connector M12x1 Counter electronics..e34r = LCD, 0(4)-20 ma, 2 x relays Dosing electronics..g34r = LCD, 0(4)-20 ma, 2 x relays ADI electronics* Display Power supply Output Contacts K..= Bargraph/ Digital display 0=100-240 V AC/DC 3= 18-30 V AC, 10-40 V DC 0= without 4= 0(4)-20 ma, 0-10 V 2= 2 changeover contacts Plug-on display For model...l442 (with 2-wire, 4-20mA output and DIN plug connector) Description 4-digit LED, connector DIN 43650, 2-wire, supply through analogue output as above however with additional open collector output Order number AUF-1000 AUF-1001 Page 14 K04/0318

12. Dimensions (mm) Model: -...L3.. / - F.. (with analogue output) M 12x1 H 40 G SW B 51 Model: -..L4.. (with analogue output and optional plug-on display) G SW B H G 1/2, 1/2 NPT 27 78 40 G 3/4, 3/4 NPT 41 78 42 G 1, 1 NPT 41 78 42 G 1 1/2, 1 1/2 NPT 55 78 57 G 2, 2 NPT 70 81 58 G 3, 3 NPT 100 106 75 K04/0318 Page 15

Model: -..C.. (with Compact electronics) G SW B H G 1/2, 1/2 NPT 27 78 40 G 3/4, 3/4 NPT 41 78 42 G 1, 1 NPT 41 78 42 G 1 1/2, 1 1/2 NPT 55 78 57 G 2, 2 NPT 70 81 58 G 3, 3 NPT 100 106 75 Model: -..Z.. (with pointer indication) 6,6 73 OBOLD H 98 G SW 51 B Page 16 K04/0318

Model: -..K,..G..,..E.. (with ADI evaluating electronic, counter or dosing electronic) G SW B H G 1/2, 1/2 NPT 27 78 40 G 3/4, 3/4 NPT 41 78 42 G 1, 1 NPT 41 78 42 G 1 1/2, 1 1/2 NPT 55 78 57 G 2, 2 NPT 70 81 58 G 3, 3 NPT 100 106 75 K04/0318 Page 17

13. EU Declaration of Conformance We, KOBOLD-Messring GmbH, Hofheim-Ts, Germany, declare under our sole responsibility that the product: Turbine-wheel flow meter Model: -... to which this declaration relates is in conformity with the standards noted below: EN 61000-6-4:2011 Electromagnetic compatibility (EMC) - Part 6-4: Generic standards - Emission standard for industrial environments EN 61000-6-2:2005 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity for industrial environments EN 61010-1:2010 Safety requirements for electrical equipment for measurement, control and laboratory use - Part 1: General requirements EN 60529:2014 Degrees of protection provided by enclosures (IP Code) EN 50581:2012 Technical documentation for the assessment of electrical and electronic products with respect to the restriction of hazardous substances Also the following EC guidelines are fulfilled: 2014/30/EU 2011/65/EU EMC Directive RoHS Hofheim, 08 March 2018 H. Peters M. Wenzel General Manager Proxy Holder Page 18 K04/0318