BFM-II BFM-II BRANCH FEEDER MONITOR. Highlights

Similar documents
EM132 EM132. Main Features. Multi-functional 3-Phase Transducer. Energy Meter

EM133 EM133 TOU SMART ENERGY METER. Main Features. Multifunctional 3-Phase Smart Meter. Billing/TOU Energy Meter

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM130 PLUS PM130 PLUS POWER METER. Features. Models. Multifunctional 3-phase Power Meter

PMC 530 Series Advanced Multifunction Meter

PM180 INSTALLATION MANUAL. PM180 Series SUBSTATION AUTOMATION UNIT. BG0521 Rev. A4

PM180 INSTALLATION MANUAL. PM180 Series SUBSTATION AUTOMATION UNIT. BG0521 Rev. A7

AcuRev Multi-Circuit Power and Energy Meter. Shop for Accuenergy products online at:

Designed For Reliability Manufactured To Last

PMC-630 Series Advanced Multifunction Meter

EM-1000 /EM-2000/ EM-3000 Series Multifunction Power and Energy Meters

PowerLogic power-monitoring units. Power Meter PM500. Technical data sheet 2006

Electronic Submeter with Advanced WiFi Ethernet Capability

AcuRev 2000 Multi-Circuits Networked Multifunction Power and Energy Meter

EM920 HIGH PERFORMANCE REVENUE SOCKET METER CUTTING EDGE POWER QUALITY ANALYZER FAST TRANSIENT & FAULT RECORDER

APU 200 Automatic DATA SHEET Gen-set Controller DATA SHEET

AcquiSuite Ally 48 Advanced Branch Circuit Monitor

Digital Multifunction Meters. Digital Multifunction Meters

Data Sheet. Digital Multifunctional Power Meter with LCD Display and Optional Modules WPM D

PowerLogic power-monitoring units. EM1000 series power meter. Technical data sheet

Multifunction Transducer MT440

RT12-240V/2.4kW Rectifier Specification

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

RGM180 Display Series

PowerLogic power-monitoring units. PM1000 series power meter. Technical data sheet

USER MANUAL 2012 V1.1

RT4F-110V/25A RECTIFIER

RT4F-48V/50A-WAC RECTIFIER

Bus Bar Protection Relay B-PRO 4000

MID PRELIMINARY DATA SHEET. RI-D Series. Single Phase Multifunction Energy Meter (MID Certified) MID

Three-phase electricity meter with instantaneous reading of electrical variables. Input current measurement: 5 A, 90 A, 150 A, 250 A (span by model).

SEL-734B Data Sheet. Advanced Monitoring and Control System. Major Features and Benefits

HMI software. gems 3100 Multi-Channel Power Meter

FEATURES DESCRIPTION FEATURES

ACUREV 2000 Multi-Circuits Networked Multifunction Power Energy Meter

RT4F-120V/20A-WAC RECTIFIER

RT4B-110V/12A RECTIFIER

Voltage Transducer UMT516 / MT516

MIC-2 Multi-instrument DATA SHEET

AcquiSuite Ally 12 & 48 Advanced Multi-Circuit Meter

PowerLogic power-monitoring units. DM6000 series digital panel meters. Technical data sheet

UW Purchase Specification Section

DEIF A/S. MIC Multi-instrument G. Data sheet. Features. Accuracy. Measurements. Installation. Intelligent. Display. Communication DEIF A/S

RT7-48V/6kW Specification

IPD163C. Single-Phase Multifunction Meter User Manual Version: V1. August 20, 2017

ezpac TM SA300 POWER QUALITY ANALYZER FAULT RECORDER SEQUENCE OF EVENTS PROTECTION, CONTROL & ALARM FUNCTIONS REVENUE GRADE METER

FEATURES DESCRIPTION SPECIFICATIONS

Power Meter PowerMonitor 500

Relion 611 series. 611 series Type Test Certificate

MIC-2 MKII, Multi-instrument DATA SHEET

NEW MODERNSTE TECHNOLOGIE. Elektronische Messgeräte mit hoher WiFi Ethernet Leistungsfähigkeit. Führende Technologie in der Industrie

Energy Management Energy Transducer Type ET112

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MODULAR CIRCUIT MONITORING SYSTEM

PM800 series. Applications

RTU560. CT/VT Interface 560CVT10. Meter Operation. Application. Characteristics. Data Sheet CT/VT Interface 560CVT10. Instantaneous Meter Values

PowerSmart Socket POWER QUALITY METER

INTEGRA DIGITAL METERING SYSTEMS

B+G E-Tech User Manual for SDM630 SDM630. Din Rail Smart Energy Meter for Single and Three Phase Electrical Systems USER MANUAL 2013 V1.

Transformer Protection Relay

Protection Relays PHASE & RESIDUAL OVERCURRENT

Metering Devices IQ 300

Acuvim L Series. Multifunction Power Meters FEATURES

Hot pluggable communication modules

Output Voltage* (nom.)(adjustable)

RT9-48V/1.4kW Rectifier Specification

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

DATA SHEET. Advanced Power Meter, APM 380 & APM 305

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ETC One Plus Network Communicator Installation and Operation Manual

Communication Gateway COM 610. Product Guide

PowerLogic power-monitoring units ION8800. Technical data sheet 2009

SAMSUNG ELECTRO-MECHANICS CO., LTD

PSL. Power Quality & Energy Monitoring. PQube power quality & energy analyzer. Low-Cost, High-Precision

Millenium 3. General Characteristics. General environment characteristics for CB, CD, XD, XR and XE product types

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

Autodaptive Capacitor Control M 2501B

SDM120C. Single-Phase Energy Meters. RS485 Modbus RTU. User Manual V1.0

PQube 3. Power Quality, Energy & Environment Monitoring. New Low-Cost, High-Precision

For Transmission, Distribution and Machinery protection.

TU531, TU532 Terminal Unit

EM6400 series Multi-Function meters

SUBJECT TO CHANGE WITHOUT NOTICE

Programmable Power Supply with DALI

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

TF501, TF521 Terminal Bases

Output Voltage* (nom.)(adjustable)

Type VRLTC tap changer

DIN Rail Smart Meter for Single and Three Phase Electrical Systems

TM258LF42DT compact base M I/O - 24 V DC - CANopen

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

Bulletin 290/291 ArmorStart LT Distributed Motor Controllers Specifications

PM180. expertmeter TM MULTI-PURPOSE DEVICE FOR MANY APPLICATIONS, INCLUDING: INDUSTRIAL & SUBSTATION AUTOMATION CONTROLLER

UMG 511. Class A EN UMG 511 Class A power quality analyzer. according to EN50160, IEEE 519, ITIC, IEC Areas of application

MW/MVAR Transducer Specifications

DIRIS A-30 Multifunction power metering & monitoring device - PMD

SMART MULTIFUNCTION METER

MINER-S Station Controller. Substation Automation

EngyVolt RV12 and RV15

AP25-1DO METER (MID CERTIFIED) User Manual - Issue 1.0

Transcription:

BRANCH FEEDER MONITOR SATEC s is the second generation of Branch Feeder Monitor, providing energy management for multi-point power solutions. Ideal for both new and retrofit projects, the automatically provides metering, demand and energy readings, logging and multi-tariff (TOU) data. The monitors up to 18 three-phase circuits, 54 single-phase circuits, or any combination of single or three phase circuits. This flexibility makes the perfect for multi-tenant facilities such as residential projects, office buildings and shopping malls. Its modular design offers a selection of 18, 24, 30, 36, 42 or 54 channels to fit any requirement and to easily fit into existing panel boards or be flush mounted nearby, thus eliminating the need for expensive retrofit projects or for allocating extra space for the device. The supports power quality monitoring to identify existing and potential operation problems, such as overloading or malfunctioning due to voltage or current harmonics, or voltage sags and swell. The utilizes High Accuracy Current Sensors (HACS), which measure and report the current consumed by each of the branch circuits at the panel board. For billing purposes, single or multiple circuits can be defined for each customer. This flexibility allows for a simple reassignment of circuit groups without wiring changes, and enables easy changes when tenants move in and out. Main panel board or load center installation makes for a valuable saving of both time and money. The BFM s user-defined and easily configured alarm system enables users to take predictive maintenance action in order to avoid unnecessary outages. Highlights Multi-channel sub-metering up to 54 single-phase, 18 two-phase or 18 three-phase meters in a single device. Any combination of single-, two-, and three-phase consumers can be chosen up to a total of 54 current inputs. Automatic totalization energy from different sub-consumers Modular design allows selection of 18, 24, 30, 36, 42 or 54 submeters

Features Includes high accuracy current transformers with Class 0.5S accuracy 3-phase/2-phase/single-phase meters (true RMS, volts, amps, power, power factor, neutral current) Ampere/Volt demand meter Time-of-Use, 8 energy/demand registers x 8 tariffs, 4 seasons x 4 types of days, 8 tariff changes per day, easy programmable tariff schedule Automatic 120 day daily profile for energy and maximum demand readings (total and tariff registers) separate for each submeter Power quality monitoring including voltage and current harmonics (up to the 25 th ), voltage sags, voltage swells and interruptions (future) Event recorder for logging internal diagnostic events and setpoint operations Data recorders; programmable periodical data logs separate for each submeter Embedded programmable controller (4 control setpoints, programmable thresholds and delays) separate for each submeter Detachable optional 3.5 inch 320 240 pixels touch screen display with backlight Internal clock, keeping the clock running over years without external power Standard RS-485, Ethernet and USB ports Optional cellular communication port plug-in module Optional 9/18 digital inputs plug-in module Modbus RTU, Modbus TCP and DNP3-DNP/TCP communication protocols Easy field upgrading device firmware Technical Specifications Environmental Conditions Operating temp. Storage temperature Humidity Altitude Construction OVERALL DIMENSIONS Width Height Depth Weight MATERIALS Enclosure & Panels PCB -30 C to +70 C (-22 F to 158 F) -40 C to +85 C (-40 F to 185 F) 0 to 95% non-condensing 2000m 278 mm/10.94" (18 channels) 554 mm/21.81" (54 channels) 128 mm/5.04" 72.5 mm/2.85" 1.6kg (36 channels) Polycarbonate FR4 (UL94-V0) Terminals Plug-in connectors Packaging case Labels Power Supply PBT (UL94-V0) Polyamide PA6.6 (UL94-V0) Carton and Stratocell (Polyethylene Foam) Brackets Polyester film (UL94-V0) Withstanding Insulation: 4kV AC @ 1min 3 PHASE POWER SUPPLY (1, 2 OR 3 PHASE OPERATION) 3 X120/208 277/480 VAC Input range Max. Power Burden for 277V 70-561VAC 50/60 Hz 10W < 17 VA Wire Size up to 10 AWG (up to 6 mm 2 ) 10 mm, 4 pins and Signal Ground stud

Input Ratings AC VOLTAGE INPUTS: V1, V2, V3, VN Measuring range Impedance Input Burden for 277V Burden for 120V Galvanic Isolation, withstanding insulation Wire Size AC CURRENT INPUTS 3 x 120/208 277/480 VAC 10MΩ 0.08 VA 0.02 VA 4kV AC @ 1min Removable, 4 terminals Up to 10 AWG (up to 6 mm2) 10 mm Standard: I1 I54 HACS Input via SATEC HACS 100A to 3000A Operating range Nominal measured Current Burden Overload Withstand Maximum continuous 120% I max, i.e 120A for HACS 100A 50A RMS (HACS 100A) < 0.15 VA 100A RMS continuous Removable, 6 terminals for 3 current inputs Wire Size 10 AWG (2.5 to 6 mm 2 ) 5 mm Optional: I1 I54 RS5 Input via SATEC HACS CS05S Operating range Nominal measured Current Burden Overload Withstand Maximum continuous: 20A (Primary current) 5A RMS (Primary current) < 0.15 VA 12A RMS continuous Removable, 6 terminals for 3 current inputs Wire Size 10 AWG (2.5 to 6 mm 2 ) 5 mm Plug-In I/O Modules 18 DIGITAL INPUTS - 9/18 DI (UP TO 4 MODULES) Optically isolated input, dry contact sensing (voltage-free) Internal power supply 5 VDC Sensitivity Scan time Open @ input resistance > 16kΩ, closed @ input resistance < 10kΩ ½ cycle Wire Size 12 AWG (up to 2.5 mm 2 ) 3.81 mm Communication Ports COM1 STANDARD (MCM) Serial EIA RS-485 optically isolated port Withstanding Insulation 4kV AC @ 1 min Removable, 3 terminals 5 mm Wire Size up to 12 AWG (up to 2.5 mm 2 ). Baud Rate up to 115,200 bps Supported Protocols MODBUS RTU/ASCII, DNP 3.0 COM3 standard (MCM Display Communication port) Serial TTL RS-232 non-isolated port for the GDM Baud Rate Supported Protocols USB Port standard (MCM) Isolated USB 1.1 port Withstanding Insulation Supported protocols up to 460,800 bps MODBUS RTU 4kV AC @ 1 min A male, standard USB cable, max. Length 2 meters MODBUS RTU ETHERNET PORT STANDARD (MCM) Transformer-isolated Withstanding Insulation Supported Protocols 10/100Base-T port 4kV AC @ 1 min RJ45 modular MODBUS TCP (Port 502), DNP3/TCP (port 20000) Number of simultaneous connections (sockets): 5 SNTP time synchronization

Real-time Clock Accuracy: better than 5 sec/month @ 25 C Memory Log Standard onboard memory: 256 Mbytes Graphical Display Module GDM (option) 3.5 Inch Touch-Panel LCD graphic TFT display Resolution 320 x 240 Operating temperature -20 C - +70 C Communication Serial TTL RS-232 non-isolated port Standards Specifications EMC per IEC 62052-11, IEC 62053-22, ANSI C12.1 and ANSI C12.20 IEC61000-4-2: Electrostatic discharge, 15/ air/contact IEC61000-4-3: Electromagnetic RF Fields, 10V/m @ 80MHz 1000MHz IEC61000-4-4: Fast Transients burst, 4KV on current and voltage circuits and 2 KV for auxiliary circuits IEC61000-4-5: Surge 6KV on current and voltage circuits and 1 KV for auxiliary circuits IEC61000-4-6: Conducted Radio-frequency, 10V @ 0.15MHz 80MHz IEC61000-4-8: Power Frequency Magnetic Field IEC61000-4-12: Damped oscillatory waves, 2.5kV CM and 1kV DM ANSI C12.1 4.7.3.3.1: 100kHz Ring Wave surge, 6kV @ 0.5kA (per IEEE C62.41.2-2002) ANSI C12.1 4.7.3.3.2: line surge, 1.2/50μs 8/20μs, 6kV @ 3kA (per IEEE C62.41.2-2002) ANSI C12.1 4.7.3.11: SWC 2.5kV (per IEEE 37.90.1) CISPR 22 class B Insulation IEC 62052-11 (per NMI M6-1): Insulation impulse 12 kv/50ω @ 1.2/50 μs IEC 62053-22: AC voltage tests related to ground, 4 kv AC @ 1mn, for power and signal ports (above 40V), or according to UL 61010-1/916 for basic and/or double insulation and Installation Category III Safety UL 916 NMI M6-1 Accuracy IEC/AZ 62053-22, class 0.5S ANSI C12.20-2010, Class 100, 400, accuracy 0.5% Atmospheric Environment Accuracy Operational ambient temperature range: 25 C to +60 C Operational ambient temperature range: 40 C to +70 C Long-term damp heat withstand according to IEC 68-2-3 <95% (non-condensing), +40 C Transport and storage temperature range: 40 C to +85 C IEC 62052-11 (ref. IEC 60068-2-6): Vibration - Frequency range: 10Hz to 150Hz - Transition frequency: 60Hz - Constant movement amplitude 0.075mm, f < 60Hz - Constant acceleration 9.8 m/s 2 (1g), f > 60Hz IEC 62052-11(ref. IEC 60068-2-27): Shock - Half sine pulse - Peak acceleration: 30g n (300 m/s 2 ) - Additional Transport vibration and shocks: - Longitudinal acceleration: 2.0 g - Vertical acceleration: 1.2 g - Transversal acceleration: 1.2 g IEC 60529: IP50

Measurement Specifications Parameter Full Scale @ Input Range Accuracy Range Voltage Line current V L = 120V V L = 230V Instrument current transformer CTs I L = 100A % Reading % FS Conditions 0.3 0.05 100 to 300 V 0 to Vmax = 600 V 0.5 0.05 1 to 100% FS 0 to HACS primary current Starting current: 0.1% FS Active power 2 Vmax I L/1000, kw 1 0.02 PF 0.5 1-120.000 to 120.000 kw Reactive power 2 Vmax I L/1000, kvar 1 0.02 PF 0.9 1-120.000 to 120.000 kvar Apparent power 2 Vmax I L/1000, kva 1 0.02 PF 0.5 1 0 to 120.000 kva Power factor 1.0-1.0 PF 0.5, I 2% FSI -0.999 to +1.000 Frequency 0.02-50 Hz: 39.00 to 65.00 Hz 60 Hz: 45.00 to 70.00 Hz Active energy import 4 Reactive energy import/export Class 0.5S under conditions as per IEC/AZ 62053-22 Class 0.5 under conditions as per ANSI C12.20:2010 Class 1.0 under conditions as per IEC/AZ 62053-21:2003, PF 0.9 39 Hz up to 70 Hz 0 to 99,999,999.9 kwh 0 to 99,999,999.9 kvarh Apparent energy Class 1.0 under conditions as per IEC/AZ 62053-21:2003 0 to 99,999,999.9 kvah 1 @ 80% to 115% of voltage FS and 1% to 100% of current FS FSV - voltage full scale FSI - current full scale Notes 1. Accuracy is expressed as ± (percentage of reading + percentage of full scale) ± 1 digit. This does not include inaccuracies introduced by the user's potential and current transformers. Accuracy calculated at 1-second average. 2. Specifications assume: voltage and current waveforms with THD 5% for kvar, kva and PF; reference operating temperature: 20 C - 26 C. 3. Measurement error is typically less than the maximum error indicated here. 4. Accuracy of the device with HACS 100A (solid core type) complies with IEC 62053-22 class 0.5S standard

Order String OPTIONS Current (for standard 18 channels) 100A to 3000A High Accuracy Current Sensors (HACS). HACS Requires ordering of up to 18 HACS. 5A split core remote high accuracy current sensor RS5 (HACS). Requires ordering of up to 18 CS05S. Calibration at Frequency 50 Hz 50HZ 60 Hz 60HZ Display Options Detachable Graphic Display Module Blank Panel G X BFM II OPTIONAL MODULES (ordered separately) Current Input Module (CIM) - up to 2 CIM's per instrument (OK to mix HACS and RS5 version in single ) 6 current input module (CIM 6) - HACS version C6H-BFM II 6 current input module (CIM 6) - RS5 version C6R-BFM II 18 current input module (CIM 18) - HACS version C18H-BFM II 18 current input module (CIM 18) - RS5 version C18R-BFM II Calibration at Frequency 50 Hz 50HZ 60 Hz 60HZ Communication Options 2G/3G GSM Modem plus 2nd RS-422/485 communication port T3G-BFM II 2G/3G CDMA Modem plus 2nd RS-422/485 communication port T3C-BFM II I/O Options 9 digital inputs module DI9-BFM II 18 digital inputs module DI18-BFM II Max. 4 modules per BFM II Auxiliary Power Supply (Max. 1 module per BFM II) Auxiliary Power Supply AC/DC 90-290V AC / 90-290 VDC 90-290 V AC/DC @ -30 C to +70 C 40-290 V AC/DC @ -20 C to +60 C AUX-ACDC-BFM II